Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-Finance | ₹2.9 Cr | L1 | Accepted-Finance Accepted |
| 2 | L2₹2.9 Cr+₹3.1 L (1.08%)Accepted-Finance | ₹2.9 Cr+₹3.1 L (1.08%) | L2 | Accepted-Finance Accepted |
| 3 | L3₹2.9 Cr+₹4.1 L (1.44%)Accepted-Finance | ₹2.9 Cr+₹4.1 L (1.44%) | L3 | Accepted-Finance Accepted |
| 4 | L4₹2.9 Cr+₹7.6 L (2.65%)Accepted-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹2.9 Cr+₹7.6 L (2.65%) | L4 | Accepted-Finance Accepted |
| 5 | L5₹3.0 Cr+₹17.3 L (6.01%)Accepted-Finance | ₹3.0 Cr+₹17.3 L (6.01%) | L5 | Accepted-Finance Accepted |
Tender Value
₹3.9 Cr
EMD Value
₹7.8 L
Closing Date
18 Nov 2024, 4:00 pmClosed
Executive Engineer, STD-II, JPDCL, Jammu
Office of Executive Engineer, STD-II, JPDCL, Panama Chowk, Jammu
Construction of new 33 KV line for MES Ratnuchak and installation of RMU
2024_PDD_261537_1
STD-II/2024-25/Ratnuchak/07
Open Tender
Electrical Works
Turn-key
60 days
Ratnuchak
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,000
Executive Engineer, STD-II, JPDCL, jammu
₹7.8 L
12 Dec 2024
21 Oct 2024
20 Nov 2024
21 Oct 2024
18 Nov 2024
21 Oct 2024
Amount
Substation Main Equipment, Line-In bay at R/Stn MES Kaluchak
33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) alongwith clamps for Panther conductor
33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) alongwith clamps for Panther conductor
33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) alongwith clamps for Panther conductor
30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less, alongwith clamps for Panther conductor
33kV C&R Panel along with O/C, E/F, Differential relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port (SCADA Compatible)
33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) alongwith clamps for Panther conductor
33 kV Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m
GI Structures
Galvanised steel structures
Galvanized nuts and bolts
Control Cables
12 Core 2.5 mm2 Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
4 Core 2.5 mm2 Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
2 Core 2.5 mm2 Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
Lugs & Ferrules etc.
Conductor & Hardware
200mm² ACSR Conductor Panther
T-Clamp for ACSR Panther Conductor
Single Tension Fittings for ACSR Panther Conductor
Earth Wire 7/4.00 mm sq.
Earthing of all new equipments and structures with G.I Flat 50 x 6 mm
ST 13 Mtr. Long Poles (ST-410, SP-69)
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm alongwith tension fittings 4U bolt for ACSR 200mm2
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing of Poles Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .7cum /pole
33 kV all Equipment Foundation & Gantry foundation, as per standards (including extending & shifting of wire mesh fencing 27m long alongwith all required civil works)
33 kV yard concreting 1:4:8 with 20 mm nominal stone aggregate 4" thick/ Metalling and laying of gravels 20 mm (140sqm approx)
11KV Indoor Switchgear for dedicated 11KV MES feeder from JPDCL R/Stn Ratnuchak including re-alignment of incoming 33KV line at Receiving Station Ratnuchak, JPDCL
11 kV VCB Panel Board (12 kV, 1250A, 25 kA) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Trivector meter -5 Amps, DLMS Compliant with RS-485 port (1+2) set, SCADA Compatible
11 kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type
11 kV 400 mm2 Single Core XLPE Cable armoured, FRLS from Transformer to Incomer
11KV 3-Core XLPE 300mm² Armoured, FRLS (2 no. cables)
11KV Cable Termination kit 400mm2 Indoor
11KV Cable Termination kit 400mm2 Outdoor
11KV Cable Termination kit 300mm2 Indoor
11KV Cable Termination kit 300mm2 Outdoor
11 KV isolator, double break, 3 pole, 800 Amp. Horizontal mounting type with earth switch.
11KV Polymeric composite Disc Insulator with fitting 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fittings
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
9 Mtr. Long Pole (ST-410 SP33)
Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole (for 9 m Pole)
ST 13 Mtr. Long Poles (ST-410, SP-69)
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator with fittings, 36kV, min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with tension fittings
Cement bottoming 1:2:4 mix as per REC standards 0.7cum per pole (for 13m long Pole)
Red Oxide
Aluminium Paint
Earthing complete by GI Pipe 40mm, 2.5m long through GI Strip 25x5mm (for LAs, Isolator, Iron structures, VCB Bank, etc)
Galvanised iron of sorts
Galvanized Nuts and Bolts.
COMMON MISCELLANEOUS EQUIPMENTS & WORKS AT R/STN RATNUCHAK, JPDCL
a) VRLA type Battery Bank 30 V,100 AH , of 18 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container, flame retardant. (Three no. standby cells) with all types of control & power cables b) 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply including indication lamps, input & output ammeters, input & output voltmeters, all types of control & power cables and other accessories complete.
Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm, Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps input & output ammeters, input & output voltmeters, all types of control & power cables and other accessories complete
Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps, input & output ammeters, input & output voltmeters, all types of control & power cables and other accessories complete
120 mm2 PVC LT Cable 4 Core, armoured, FRLS
Construction of cable trench (900mmx 920mm) size in cement concrete with RCC covers from Power Transformer to Control Room (15m with separate levels for control and power cables) and Control room to outgoing structures (40m length)
Supply, erection, laying, stringing, testing & commissioning of 8 Km (approx.) new 33KV line including re-orientation/ re-erection/ dismantling (incl. transport of dismantled material to store) of any existing network (if required) and erection of Isolation points
11 Mtr. Long Pole (ST-410 SP56)
13 Mtr. Long Poles (ST-410, SP-69)
16 Mtr. Long Pole (ST-410 SP80)
Gl V cross-arm with top Bracket including clamp
Gl Channel X-arm including clamps and braces
200 mm2 ACSR Conductor
PG Clamps for 200 mm2 ACSR Panther Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator with fittings, 36kV, min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm tension fittings 4U bolt for ACSR 200mm2
33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA), for isolation point
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by Gl Pipe 40 mm or Gl Rod 20mm 2.5 mtr long through Gl Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .6cum /pole
Aluminium Jointing Sleeves
Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator (2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia Gl stranded wire complete
Guard Netting (with GI wire 8 SWG, GI Channel X-arm including clamps and braces, Eye Bolts)
33kV, Single core 400 mm2 Aluminium round wire Armoured XLPE(E) Cable, FRLS (one spare cable) along with HDPE pipes of suitable size for laying cable at Railway crossing
33 KV Cable Termination kit 400mm2 Outdoor
Installation of RMU at receiving station MES Ratnuchak
33KV, Three core 300 mm2 Aluminium, flat wire Armoured XLPE Cable , FRLS i. From Line-in to RMU (2 no.) ii. RMU to Receiving Substation Transformer bay (1 no.) iii. RMU to outgoing Line towards Kaluchak Rec. Stn. (1no.)
HDPE Pipe Outer Dia 180 mm Inner Dia 152 mm for laying of 33kV XLPE Cable from RMU to tapping point of 33kV Kaluchak tapline
33kV RING MAIN UNIT: 4 way (2+2) Out-put type RMU, SF6 Insulated, extensible type, at 33kV system voltage and breaking capacity 25kA for one second, with SF6 circuit breaker / VCB self powered with O/C + E/F Relay system comprising of: a) Two (2) Nos. 33kV, 630 Amp. motorized Isolators including earthing switches with making capacity 62.5kA, having mechanical ON/OFF b) Two (2) No. 33kV, 200Amp motorized, spring operated, Circuit Breakers (CB) with earthing switches c) Cu Bus - Bar of 630 Amp. rating d) Two (2) No. Numerical Aux. self powered relay having non-directional O/C and E/F protection (for each Circuit Breaker feeder). Relay should have minimum 7-DI & 8- DO. The relay shall also interface via an RS 232/485 port in order to send, as a minimum, real-time readings using the MODBUS protocol. e) Incoming Isolators shall have FPI with electrical reset contact / facility. f) All necessary potential-free contacts for indications relevant to RMU monitoring and control, and also extending indications in the control room. g) Capacitor Voltage Dividers serving live-line cable indicators in each Breaker & Isolator. h) All required extensions so that required auxilliary and DC supply for operation of RMU is available.
33 kV 3-core cable terminating kit outdoor to be used with XLPE cables - 300 sq.mm.
Touch Proof Switchgear Plug-in Termination cable kits (screened, separable elbow connector with built-in trifurcation kit for three core version) for RMU Cable Termination
Cable route Markers.
Excavation in any type of soil including hard laterite soil.
Refilling of excavated soil
Sand for cushioning of the cables in the trench.
Cement Tiles of size 300mm length x250mm width x 37mm thick as a protective cover for underground cables.
Earthing of RMU -- Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 75mm x 10mm & 50mm x 6mm for connection of RMU body as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations)
Centering and shuttering including struttings, propping etc and removal of formwork.
15 mm cement plaster 1:4 (1 - cement: 4 -fine sand) for foundations.
Wire mesh boundary fencing around the RMU
33 kV Isolator with Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) complete
33 kV Lightening Arrestors (30 kV, 10KA, Station class, ZnO, Porcelain/Polymer) gap less
M/S COMBINE GROUP OF ENGINEERS (BID ID -2224683)
CROSSBOW POWER PVT LTD (BID ID -2239525)
SATISH & CO (BID ID -2238147)
Gee Sab Electricals (BID ID -2237966)
power control system (BID ID -2239514)
AJAY CONSTRUCTION (BID ID -2224530)
The Trikuta Engineer (BID ID -2223963)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .