| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹8.4 L (6.75%)Admitted-Finance | ₹1.3 Cr+₹8.4 L (6.75%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical NOT ELIGIBLE |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT ELIGIBLE |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT ELIGIBLE |
| Sl No | Description | Qty | Unit | sagar electricals L1 | Calcutta Power Construction Co. L2 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box/PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group A)
Cable make:-Havells/Finolex/RR Kabel/Equivalent approved by EIC. Pvc pipe make:-Precision/Presto plast/Finolex/ Equivalent approved by EIC. Switch/Socket Make:-Crabtree (Athena) /Legrand (Myrus)/MK (Wrap round plus)/Equivalent approved by EIC. | 8 | Each | 810 ₹6,480 | 750 ₹6,000 Lowest |
| 2.00 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single
phase AC Supply, earthing etc. complete as required.
Colour-White, Make: Atomberg/Orient/Crompton/Usha/ Havells/Polar/Bajaj/Equivalent approved by EIC.
Note:1.Successful bidder has to provide 5 years on site replacement guarantee of the ceiling fan after commissioning during Defect Liability Period of 5 Years from OEM ( Authority /official must be signed not lower the rank of GM or equivalent in corporate structure). Replacement gurantee should be in the name of IIT Kharagpur. Defective Ceiling fan must be replaced with New BLDC Ceiling fan within 2 days time, other wise two times cost of ceiling fan will be deducted from their Security Deposit.
2. Agency has to provide Labeling on each fan with paint/permanent markers mentioning - Name of the Hall of Residences, Date of installation is mandatory. | 4,083 | Each | 2,575 ₹1,05,13,725 Lowest | 2,995 ₹1,22,28,585 |
| 3.00Extra for providing and fixing of fixed type electronic regulator compatiable to above BLDC Fan including S&F of PVC modular/non-modular box with cover plate /sheet as per site condition. | |||||
| 3.01 | Non modular type | 3,346 | Each | 210 ₹7,02,660 | 125 ₹4,18,250 Lowest |
| 3.02 | Modular type | 737 | Each | 310 ₹2,28,470 Lowest | 360 ₹2,65,320 |
| 4.00 | Buyback price of exsisting old ceiling fan of any sizes ( 36/48/56 inches) on as-is-where-is basis including dismantling and taking way (Rate shall be considered negative for this item) | 3,583 | Each | 275 ₹9,85,325 | 100 ₹3,58,300 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹2.3 L
Closing Date
20 Feb 2020, 3:30 pmClosed
Chief Engineer
Office of the Chief Engineer, ESTATE ( EM), Head Office, 1st Floor, Old Buildin,
Supply and fixing of BLDC ceiling fans in different Hall of Residences at IIT Kharagpur
2020_IITKG_539500_1
IIT/E/EM/T/77/2019-20
Open Tender
Electrical Works
Item Rate
60 days
IIT Kharagpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹2.3 L
Yes
ESTATE ( EaM), Head Office, 1st Floor, Old Buildin
10 Aug 2020
27 Jan 2020
21 Feb 2020
27 Jan 2020
20 Feb 2020
27 Jan 2020
14 Feb 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box/PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group A) Cable make:-Havells/Finolex/RR Kabel/Equivalent approved by EIC. Pvc pipe make:-Precision/Presto plast/Finolex/ Equivalent approved by EIC. Switch/Socket Make:-Crabtree (Athena) /Legrand (Myrus)/MK (Wrap round plus)/Equivalent approved by EIC.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Colour-White, Make: Atomberg/Orient/Crompton/Usha/ Havells/Polar/Bajaj/Equivalent approved by EIC. Note:1.Successful bidder has to provide 5 years on site replacement guarantee of the ceiling fan after commissioning during Defect Liability Period of 5 Years from OEM ( Authority /official must be signed not lower the rank of GM or equivalent in corporate structure). Replacement gurantee should be in the name of IIT Kharagpur. Defective Ceiling fan must be replaced with New BLDC Ceiling fan within 2 days time, other wise two times cost of ceiling fan will be deducted from their Security Deposit. 2. Agency has to provide Labeling on each fan with paint/permanent markers mentioning - Name of the Hall of Residences, Date of installation is mandatory.
Extra for providing and fixing of fixed type electronic regulator compatiable to above BLDC Fan including S&F of PVC modular/non-modular box with cover plate /sheet as per site condition.
Non modular type
Modular type
Buyback price of exsisting old ceiling fan of any sizes ( 36/48/56 inches) on as-is-where-is basis including dismantling and taking way (Rate shall be considered negative for this item)
Calcutta Power Construction Co.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_565230.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .