Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.0 LAccepted-AOC 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹27.8 L+₹1.1 L (3.95%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹31.4 L+₹4.6 L (17.1%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-3 | Rejected-AOC L-3 |
Tender Value
Refer Docs
EMD Value
₹93,500
Closing Date
23 Jan 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
DAY TO DAY REPAIR/MAINTENANCE COMPLAINTS FOR WATER SUPPLY LINES IN KWC AREA AND REPAIR/MAINTENANCE OF FIRE FIGHTING, RO SYSTEM AND CENTRIFUGAL, MONOBLOCK/SUBMERSIBLE PUMP AT METCALFE HOUSE UNDER GE I RND DELHI
2022_MES_571361_1
GE/RND-89/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat-a(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹93,500
Yes
8 Apr 2023
26 Dec 2022
25 Jan 2023
26 Dec 2022
23 Jan 2023
10 Jan 2023
Amount
M&L for opening of the Filter media tank and remove the existing media and Sand from the tank and clean the tank properly and last wash with Hypo/ bleaching solution complete all as specified and directed.
Supply and pouring in repair natural gravels of various sizes (5mm-40mm) (25 Kg each pack) as per requirement complete all as specified and directed.
All as per item Ser No. 2.00 above but selex media (25 Kg each pack).
All as per item Ser No. 2.00 above but coarse sand media sizes as directed.
All as per item Ser No. 2.00 above but carbon media (25 Kg each pack).
S&F in repair stainless steel tubing (SS-304) 80mm dia heavy duty with all accessories/joints complete all as specified and directed.
All as per item Ser No. 6.00 above but 50 mm dia.
All as per item Ser No. 6.00 above but 40 mm dia.
S&F in repair CI 50mm bore hand operated butterfly valve including gasket & flange complete all as specified and directed.
All as per item Ser No 9.00 above but 80mm.
All as per item Ser No 9.00 above but 100mm.
All as per item Ser No 9.00 above but 150mm.
S&F in repair CPVC ball valve of 25mm dia with all fitting and fixtures complete all as specified and directed.
All as per item Ser No. 13.00 above but 40mm.
All as per item Ser No. 13.00 above but 50mm.
S&F in repair Stainless steel long ball valve (SS-304) 50mm bore dia heavy duty with all accessories/joints complete all as specified and directed.
All as per item Ser No. 16.00 above but 80mm bore dia.
S&F in repair CPVC long length ball valve 50mm bore dia with all fittings & fixtures complete all as specified and directed.
All as per item Ser No. 18.00 above but 80mm bore dia.
All as per item Ser No. 18.00 above but 100mm bore dia.
S&F in repair SS NRV 50mm bore dia with all acessories complete all as specified and directed.
All as per item Ser No. 21.00 above but 80mm bore dia.
All as per item Ser No. 21.00 above but 100mm bore dia.
S&F in repair membrane of size 80mmx40mm complete all as specified and directed.
S&F in repair cartridge 20"X 4.5 " dia for PP filter water treatment plant complete all as specified and directed.
All as per item Ser No. 25.00 above but 20"X 4.5 " dia for wound cartridge water treatment plant.
All as per ser item No. 25.00 above but 30"X 4.5 " dia for PP filter water treatment plant
All as per item Ser No. 25.00 above but 30"X 4.5 " dia for wound cartriage water treatment plant.
S&F in repair CPVC pipe 25mm dia with all fitting and fixtures and joints complete all as specified and directed.
All as per item Ser No. 29.00 above but 40 mm dia.
All as per item Ser No. 29.00 above but 50 mm dia.
All as per item Ser No. 29.00 above but 80 mm dia.
All as per item Ser No. 29.00 above but 100 mm dia.
Opening of Softner tank and remove all the raisen & gravel, mud and wash with the Hypo/ bleaching solution and fill the new gravels not less than 200 kg and raisen not less than 100 cubic feet after washing/cleaning complete all as specified and directed.
Supply only industrial salt (50 kg each pack) for water softner tank complete all as specified and directed.
S&F in repair foot valve CPVC 100mm bore complete all as specified and directed.
S&F in repair foot valve CPVC 80mm bore complete all as specified and directed.
M&L for servicing automatic panel with replacement of existing wiring as per existing material and upload of software for working of all RO system in automode complete all as specified and directed.
S&F in repair chemical Dozing pump for RO plant complete all as specified and directed.
S&F in repair water meter of size 80 mm for RO plant complete all as specified and directed.
M&L in repair chemical Dozer pipe for RO plant complete all as specified and directed.
S&F in repair of MS chanel medium weight of size 100mm x 50mm including cutting to required size complete all as specified and directed.
Supply only sodium hypochloride (liquid bleach) 10 % (20 ltr each pack) complete all as specified and directed.
Supply only sodium meta bi-sulphite (25 Kg each pack) complete all as specified and directed.
Supply only citric acid monohydrate (25 Kg each pack) complete all as specified and directed.
Supply only light soda ash (25 Kg each pack) complete all as specified and directed.
Supply only CX-002 RO Antiscalant Solution (25 kg each pack) complete all as specified and directed.
M&L for painting with two coat of synthetic enamelled paint over a coat of red oxide primer on new steel surface including preparation of surface complete all as specified and directed.
S&F in repair PVC copper conductor unsheathed 6 Sqmm single core cable three Nos including flexible PVC conduit medium grade of size 25 mm dia complete all as specified and directed.
S&F in repair of PVC copper conductor unsheathed 10 Sqmm single core cable three Nos including flexible PVC conduit medium grade of size 40 mm dia complete all as specified and directed. Note for item No 49 & 50 :- Three run of cables & one run of PVC conduit shall be measured as one unit (RM)
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 32mmx6mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 32mm x 6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel shall be properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
S&F in repair GI Socket medium Grade, ISI marked of Size 15 mm complete all as specified and directed.
S&F in repair GI Socket medium Grade, ISI marked of Size 20 mm complete all as specified and directed.
S&F in repair GI Socket medium Grade, ISI marked of Size 25 mm complete all as specified and directed.
S&F in repair GI Socket medium Grade, ISI marked of Size 40 mm complete all as specified and directed.
S&F in repair GI Socket medium Grade, ISI marked of Size 50 mm complete all as specified and directed.
S&F in repair GI Elbow medium Grade, ISI marked of Size 15 mm complete all as specified and directed.
S&F in repair GI Elbow medium Grade, ISI marked of Size 20 mm complete all as specified and directed.
S&F in repair GI Elbow medium Grade, ISI marked of Size 25 mm complete all as specified and directed.
S&F in repair GI Elbow medium Grade, ISI marked of Size 40 mm complete all as specified and directed.
S&F in repair GI Elbow medium Grade, ISI marked of Size 50 mm complete all as specified and directed.
S&F in repair GI Union medium Grade, ISI marked of Size 15 mm complete all as specified and directed.
S&F in repair GI Union medium Grade, ISI marked of Size 20 mm complete all as specified and directed.
S&F in repair GI Union medium Grade, ISI marked of Size 25 mm complete all as specified and directed.
S&F in repair GI Union medium Grade, ISI marked of Size 40 mm complete all as specified and directed.
S&F in repair GI Union medium Grade, ISI marked of Size 50 mm complete all as specified and directed.
S&F in repair GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of size 15 mm complete all as specified and directed.
S&F in repair GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of Size 20 mm complete all as specified and directed.
S&F in repair GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of Size 25 mm complete all as specified and directed.
S&F in repair GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of Size 40 mm complete all as specified and directed.
S&F in repair GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of Size 50 mm complete all as specified and directed.
S&F in repair PVC 'L' type Holder, Aluminium rod,Float Ball etc all as required at site and complete all as specified and directed of Size 15 mm.
S&F in repair PVC 'L' type Holder, Aluminium rod,Float Ball etc all as required at site and complete all as specified and directed of Size 20 mm.
S&F in repair PVC 'L' type Holder, Aluminium rod,Float Ball etc all as required at site and complete all as specified and directed of Size 25 mm.
S&F in repair PVC 'L' type Holder, Aluminium rod,Float Ball etc all as required at site and complete all as specified and directed of Size 40 mm.
S&F in repair PVC 'L' type Holder, Aluminium rod,Float Ball etc all as required at site and complete all as specified and directed of Size 50 mm.
S&F in repair GI Reducing socket medium grade ISI marked of Size 25 mmx15mm complete all as specified and directed.
S&F in repair GI Reducing socket medium grade ISI marked of Size 20mmx15mm complete all as specified and directed.
S&F in repair GI Reducing socket medium grade ISI marked of Size 25 mmx20 mm complete all as specified and directed.
S&F in repair GI Reducing socket medium grade ISI marked of Size 50 mmx 40mm complete all as specified and directed.
S&F in repair GI solid plug heavy duty ISI marked of Size 15 mm complete all as specified and directed.
S&F in repair GI solid plug heavy duty ISI marked of Size 20 mm complete all as specified and directed.
S&F in repair GI solid plug heavy duty ISI marked of Size 25 mm complete all as specified and directed.
S&F in repair GI solid plug heavy duty ISI marked of Size 40 mm complete all as specified and directed.
S&F in repair GI solid plug heavy duty ISI marked of Size 50 mm complete all as specified and directed.
Supply only Lead wool complete all as specified and directed.
M&L in repair mild steel Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and directed.
M&L in repair Gland dori as per requirement complete all as specified and directed.
S&F in repair Digital ammeter of existing size 100mm (Square type) and connecting up & testing complete all as specified and directed.
S&F in repair Digital Voltmeter of existing size 100mm (Square type) and connecting up & testing complete all as specified and directed.
S&F in repair Electronic timer type ET-100, 9 to 30 sec, 415V suitable for star-delta/DOL starter upto 20 HP capacity complete all as specified and directed.
S&F in repair Relay of current range 10 to 16 amps, 415 volts suitable for mounted on ML-1.5 and ML-3 Contactors complete all as specified and directed.
S&F in repair Relay of current range 28 to 42 amps, 415 volts suitable for mounted on ML-2 and ML-3 Contactors complete all as specified and directed.
S&F in repair Pressure gauge of capacity 0 to 6 kg/cm² complete all as specified and directed
S&F in repair PVC float valve with epoxy coated aluminium rod and high density ball of sizes 15 mm bore dia complete all as specified and directed.
S&F in repair PVC float valve with epoxy coated aluminium rod and high density ball of sizes 20 mm bore dia complete all as specified and directed.
S&F in repair PVC float valve with epoxy coated aluminium rod and high density ball of sizes 25 mm bore dia complete all as specified and directed.
S&F in repair PVC float valve with epoxy coated aluminium rod and high density ball of sizes 40 mm bore dia complete all as specified and directed.
S&F in repair PVC float valve with epoxy coated aluminium rod and high density ball of sizes 50 mm bore dia complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked, as per IS : 778 of size 15 mm bore dia complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked, as per IS : 778 of size 20 mm bore dia complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked, as per IS : 778 of size 25 mm bore dia complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked, as per IS : 778 of size 40 mm bore dia complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked, as per IS : 778 of size 50 mm bore dia complete all as specified and directed.
Testing of drinking water being collected from local source (bore wells/sump /shallow wells) of KWC Area & Metcalfe House Area under GE(I) R&D Delhi and submission of detailed test report to the office of Engr-in-Charge. (a) Collection of water from different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in GOVT Approved laboratory as mentioned in specification. (b ) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, PH valve TDS total hardness iron, chloride, fluride and residual free chlorine and Bacteriological total coil from organisms per 100 ml (MPN) and E coli in 100 ml) and to this office with specific recommendation regarding suitabiulity of water for drinking purpose. Note:- Rate Quoated shall deemed to be included for :- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) (iii) Testing should be carried out from Govt approved lab.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep and getting out complete all as specified and directed.
All as per item Ser No. 106.00 above but in hard/dense soil.
Returning, filling in and including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance exceeding 1.5Km but not exc 5km and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L in replacement for burning out lead joint in any position including removing old lead joint and making new lead joint by using retrived lead and new lead approx 700gms for CI pipe of 150mm bore complete all as specified and directed.
M&L in replacement for burning out lead joint in any position including removing old lead joint and making new lead joint by using retrived lead andnew lead minimum 450 gms for CI pipe of 100mm bore complete all as specified and directed.
M&L in replacement for burning out lead joint in any position including removing old lead joint and making new lead joint by using retrived lead and new lead minimum 350 gms for CI pipe of 80mm bore complete all as specified and directed.
Taking out old unserviceable sluice valves, & supply and Fix new cast iron Sluice valve IS 14846 PN 1.0 SS spindle flanged type of size 150mm bore complete all as specified and directed.
All as per item Ser No.113.00 above but of size 100mm bore.
All as per item Ser No 113.00 above but of size 80mm bore.
Isolate the water supply by operating the sluice valve at main pump house and empty the underground water sump by using pumps of suitable capacity, after emptying the sump cutting /opening the existing rusted/damaged foot valve. S&F new foot valve of size 150mm bore, Flanged/ threaded type, IS: 4038, PN 0.2 with strainer of cast iron IS 210 Gr FG 200 and joining with the existing suction pipe line including all connected items like nuts, bolts, washers, flanges etc complete all as specified and directed.
All as per item Ser No. 116.00 above but of size 100mm bore
All as per item Ser No. 116.00 above but of size 80mm bore
Isolate the water supply from Main pump house or by operating sluice valve /gate valve.T&P for opening old unserviceable non return valve by unsrewing the nut bolts, washer, flanges and S&F CIDF swing type non return valve of size 150mm bore as per IS-5312 (part 1&2) PN 1:6 CI body, door/bronze to rubber ring /SS 410 hinge pin alongwith neccessary hardware, packing material like nuts, bolts, washers, flanges etc complete for the following sizes complete all as specified and directed.
All as per item Ser No. 119.00 above but of size 100mm bore.
All as per item Ser No. 119.00 above but of size 80mm bore.
S&F in repair automatic star-delta motor starter in sheet metal enclosure type ML suitable for 3 phase electric motor of capacity upto 30 HP, 3 phase 415V with relay range 16-25 Amps complete all as specified and directed.
S&F in repair power contactor of current rating upto 60 amps and standard coil voltage 240v, 50Hz type ML-3 of aux contact (2 NO + 2 NC) including reconnection of cable complete all as specified and directed.
All as per item Ser No 123.00 above but of current rating upto 125 Amps and standard coil voltage 240v, 50Hz type ML-6 of aux contact (2 NO + 2 NC) including reconnection of cable.
S&F in repair General Purpose Load Changeover Switch Confirms to IS:13947 (Part I & III) Onload Changeover Switch - AC 23 (side handle) in sheet enclosure, 415V 4 pole of capacity 400 Amps complete all as specified and directed.
S&F in repair 6 Sqmm PVC cable unsheathed multistandarded copper conductor in & testing 25mm dia metallic conduit complete all as specified and directed.
All as per item Ser No 126.00 above but of cable size 10 sqmm.
All as per item Ser No 126.00 above but of cable size 16 sqmm. Note for item No 126 to 128 :- One RM of cable & one RM of conduit shall be measured as one unit (RM)
M&L for brick work in cement mortar 1:6 using sub class 'B' brick straight or curved on plain not exceeding 6M mean radius including demolition of old unserviceable brick work complete all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:4 on brick/concrete surface etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) in roof kerbs/coping or mud stops, rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for PCC 1:4:8 Type D2 (using 40 mm graded crushed stone aggregate) foundations, filling and mass concrete complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
S&F in repair mild steel work MS sheet, angle iron, flat iron etc including cutting welding etc complete all as specified and directed.
S&F 15mm bore GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor etc including taking out /down old unserviceable GI pipe complete all as specified and directed.
S&F 20mm bore GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor etc including takingout /down old unserviceable GI pipe complete all as specified and directed.
S&F 25mm bore GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor etc including takingout/down old unserviceable GI pipe complete all as specified and directed.
S&F 40mm bore GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor etc including takingout/down old unserviceable GI pipe complete all as specified and directed.
S&F 50mm bore GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor etc including takingout/down old unserviceable GI pipe complete all as specified and directed.
S&F 80mm bore GI pipe medium grade ISI marked including all fittings in old position in trenches/ wall/ floor etc including takingout/down old unserviceable GI pipe complete all as specified and directed.
Taking up existing CI/DI water mains line of 80 mm dia bore size including all fittings complete all as specified and directed.
Taking up existing CI/DI water mains line of 100 mm dia bore size including all fittings complete all as specified and directed.
Taking up existing CI/DI water mains line of 150 mm dia bore size including all fittings complete all as specified and directed.
Relaying, jointing, testing and commissioning of Pipe CI 80 mm bore in trenches in position complete as specified and directed. Note : Old pipe retrived from item No 141 shall be reused.
Relaying, jointing, testing and commissioning of Pipe CI 100 mm bore in trenches in position complete as specified and directed. Note : Old pipe retrived from item No 142 shall be reused.
Relaying, jointing, testing and commissioning of Pipe CI 150 mm bore in trenches in position complete as specified and directed. Note : Old pipe retrived from item No 143 shall be reused.
S&F Cast iron pipes of bore 80 mm with spigot and socket ends centrifugally cast, Class LA, in any length, laid in trenches complete all as specified and directed.
S&F Cast iron pipes of bore 100 mm with spigot and socket ends centrifugally cast, Class LA, in any length, laid in trenches complete all as specified and directed.
S&F Cast iron pipes of bore 150 mm with spigot and socket ends centrifugally cast, Class LA, in any length, laid in trenches as specified complete all as specified and directed.
S&F in repair CI fittings for spigot/socket pipes such as bends of any radius and angle, collars, tapers, tail pieces, Tee pieces, Caps and plugs suitable upto 150 mm bore dia all socketed or socket and spigot or side flanged complete all as specified and directed.
S&F in repair Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of size 80 mm bore dia complete all as specified and directed.
S&F in repair Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of size 100 mm bore dia complete all as specified and directed.
S&F in repair Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of size 150 mm bore dia complete all as specified and directed.
Labour only for cutting of existing CI/DI pipe for insertion of CI specials /valves etc. all as required including dewatering of leakage water of the size 80 mm dia complete all as specified and directed.
Labour only for cutting of existing CI/DI pipe for insertion of CI specials /valves etc. all as required including dewatering of leakage water of the size 100 mm dia complete all as specified and directed.
Labour only for cutting of existing CI/DI pipe for insertion of CI specials /valves etc. all as required including dewatering of leakage water of the size 150 mm dia complete all as specified and directed.
Taking down/out MS pipe water mains including all fittings of the size 100mm bore complete all as specified and directed.
Taking down/out MS pipe water mains including all fittings of the size 150mm bore complete all as specified and directed.
S&F MS ERW pipe of bore 100mm conforming to IS-1239, medium grade complete all as specified and directed.
S&F MS ERW pipe of bore 150 mm conforming to IS-1239, medium grade complete all as specified and directed.
S&F in repair membrane of size 40mmx40mm complete all as specified and directed.
Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of capacity 5-15 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and directed.
All as per item ser No 162.00 above but of capacity 20-30 HP
All as per item ser No 162.00 above but of capacity 40-50 HP
All as per item ser No 162.00 above but of capacity 60-100 HP
Opening the electric induction motor of capacity 5-15 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamelled copper winding wire of existing gauge ,weight etc. including all other insulating material to make it functional complete all as specified and directed. Note:- Copper winding wire of approprioate gauge will be measured as supply only
All as per item ser No 166.00 above but of capacity 20-30 HP
All as per item ser No 166.00 above but of capacity 40-50 HP
All as per item ser No 166.00 above but of capacity 60-100 HP
Disconnecting and De-coupling the Centrifugal pump of capacity 5-15 HP from foundation after opening /cutting the rusted nuts, bolts etc including transporting the pump to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and directed.
All as per item ser No 170.00 above but of capacity 20-30 HP
All as per item ser No 170.00 above but of capacity 40-50 HP
All as per item ser No 170.00 above but of capacity 60-100 HP
Opening the centrifugal pump of capacity, 5-15 HP repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and directed. Note:- Spare Parts required shall be measured & paid separately.
All as per item ser No 174.00 above but of capacity 20-30 HP
All as per item ser No 174.00 above but of capacity 40-50 HP
All as per item ser No 174.00 above but of capacity 60-100 HP
Supply only CI Impeller for Centrifugal pump of 5-15 HP Capacity complete all as specified and directed. Note :- If the contractor fails to repair the motor and pump within the seven days given to him a penality of Rs 100/- per day will be recovered from the contractor.
All as per item ser No 178.00 above but pump shaft.
All as per item ser No 178.00 above but CI Casing wear ring
All as per item ser No 178.00 above but CI interstage ring
All as per item ser No 178.00 above but CI stuffing box bush
All as per item ser No 178.00 above but CI Gland Plate
All as per item ser No 178.00 above but lentern ring
All as per item ser No 178.00 above but eye bolt with nut
All as per item ser No 178.00 above but CI Shaft sleeve
All as per item ser No 178.00 above but Gasket Packing Sheet
All as per item ser No 178.00 above but Impeller Nut
All as per item ser No 178.00 above but Gland packing champion
All as per item ser No 178.00 above but impeller key
All as per item ser No 178.00 above but coupling key
All as per item ser No 178.00 above but water liquid deflector
All as per item ser No 178.00 above but CI bearing cartridge
All as per item ser No 178.00 above but CI bearing plate
All as per item ser No 178.00 above but coupling nut
All as per item ser No 178.00 above but MS Stud with nut
Supply only CI Impeller for Centrifugal pump of 20-30 HP Capacity complete all as specified and directed. Note :- If the contractor fails to repair the motor and pump within the seven days given to him a penality of Rs 100/- per day will be recovered from the contractor.
All as per item ser No 197.00 above but pump shaft SS (AISI-410)
All as per item ser No 197.00 above but Remetling of pump shaft, turning and balancing
All as per item ser No 197.00 above but CI Shaft sleeve
All as per item ser No 197.00 above but CI Casing wear ring
All as per item ser No 197.00 above but CI interstage ring
All as per item ser No 197.00 above but CI stuffing box bush
All as per item ser No 197.00 above but CI Gland Plate
All as per item ser No 197.00 above but lentern ring
All as per item ser No 197.00 above but eye bolt with nut
All as per item ser No 197.00 above but Gasket Packing Sheet
All as per item ser No 197.00 above but GM Impeller Nut
All as per item ser No 197.00 above but Gland packing champion
All as per item ser No 197.00 a above but impeller key
All as per item ser No 197.00 above but coupling key
All as per item ser No 197.00 above but Mechanical Seal
All as per item ser No 197.00 above but water liquid deflector
All as per item ser No 197.00 above but CI bearing cartridge
All as per item ser No 197.00 above but CI bearing plate
All as per item ser No 197.00 above but coupling nut
All as per item ser No 197.00 above but MS Stud with nut
Supply only CI Impeller for Centrifugal pump of 40-50 HP Capacity complete all as specified and directed. Note :- If the contractor fails to repair the motor and pump within the seven days given to him a penality of Rs 100/- per day will be recovered from the contractor.
All as per item ser No 218.00 above but pump shaft SS (AISI-410)
All as per item ser No 218.00 above but Remetling of pump shaft, turning and balancing
All as per item ser No 218.00 above but CI Shaft sleeve
All as per item ser No 218.00 above but CI Casing wear ring
All as per item ser No 218.00 above but CI interstage ring
All as per item ser No 218.00 above but CI stuffing box bush
All as per item ser No 218.00 above but CI Gland Plate
All as per item ser No 218.00 above but lentern ring
All as per item ser No 218.00 above but eye bolt with nut
All as per item ser No 218.00 above but Gasket Packing Sheet
All as per item ser No 218.00 above but GM Impeller Nut
All as per item ser No 218.00 above but Gland packing champion
All as per item ser No 218.00 above but impeller key
All as per item ser No 218.00 above but coupling key
All as per item ser No 218.00 above but Mechanical Seal
All as per item ser No 218.00 above but water liquid deflector
All as per item ser No 218.00 above but CI bearing cartridge
All as per item ser No 218.00 above but CI bearing plate
All as per item ser No 218.00 above but coupling nut
All as per item ser No 218.00 above but MS Stud with nut
Supply only CI Impeller for Centrifugal pump of 60-100 HP Capacity complete all as specified and directed. Note :- If the contractor fails to repair the motor and pump within the seven days given to him a penality of Rs 100/- per day will be recovered from the contractor.
All as per item ser No 239.00 above but pump shaft SS (AISI-410)
All as per item ser No 239.00 above but Remetling of pump shaft, turning and balancing
All as per item ser No 239.00 above but CI Shaft sleeve
All as per item ser No 239.00 above but CI Casing wear ring
All as per item ser No 239.00 above but CI interstage ring
All as per item ser No 239.00 above but CI stuffing box bush
All as per item ser No 239.00 above but CI Gland Plate
All as per item ser No 239.00 above but lentern ring
All as per item ser No 239.00 above but eye bolt with nut
All as per item ser No 239.00 above but Gasket Packing Sheet
All as per item ser No 239.00 above but GM Impeller Nut
All as per item ser No 239.00 above but Gland packing champion
All as per item ser No 239.00 above but impeller key
All as per item ser No 239.00 above but coupling key
All as per item ser No 239.00 above but water liquid deflector
All as per item ser No 239.00 above but CI bearing cartridge
All as per item ser No 239.00 above but CI bearing plate
All as per item ser No 239.00 above but coupling nut
All as per item ser No 239.00 above but MS Stud with nut
S&F in repair Terminal Connection Plate of capacity 5-15 HP complete all as specified and directed.
S&F in repair Terminal Connection Plate of capacity 20-30 HP complete all as specified and directed.
S&F repair Terminal Connection Plate of capacity 40-50 HP complete all as specified and directed.
S&F in repair Terminal Connection Plate of capacity 60-100 HP complete all as specified and directed.
S&F in repair spare tyre for coupling type TC/P/011 complete all as specified and directed.
S&F in repair spare tyre for coupling type TC/P/013 complete all as specified and directed.
S&F in repair spare tyre for coupling type TC/P/014 complete all as specified and directed.
S&F in repair spare tyre for coupling type TC/P/015 complete all as specified and directed.
S&F in repair spare tyre for coupling type TC/P/019 complete all as specified and directed.
Supply only super enamelled copper winding wire of appropriate gauge suitable for above 7.5 HP to 100 HP capacity centrifugal pump sets etc complete all as specified and directed.
Opening the monoblock pump and taking out the burnt winding wire cleaning the slots, rewinding the monoblock pump with super enamalled copper winding wire and assembling complete upto 10 HP complete all as specified and directed. Note:- Spare Parts and copper winding wire shall be measured & paid separately
Supply only CI Impeller for Monoblock pump of upto 10HP Capacity complete all as specified and directed. Note :- If the contractor fails to repair the motor and pump within the seven days given to him a penality of Rs 100/- per day will be recovered from the contractor.
All as per item ser No 270.00 above but GM Shaft sleeve
All as per item ser No 270.00 above but Mechanical Seal
All as per item ser No 270.00 above but water Seal
All as per item ser No 270.00 above but water liquid deflector
All as per item ser No 270.00 above but Gland packing champion
All as per item ser No 270.00 above but gland packing sheet
All as per item ser No 270.00 above but impeller Nut
All as per item ser No 270.00 above but MS Stud with nut
S&F in repair Ball Bearing 6205 complete all as specified and directed.
S&F in repair Ball Bearing 6305 complete all as specified and directed.
S&F in repair Ball Bearing 6306 complete all as specified and directed.
S&F in repair Ball Bearing 6307 complete all as specified and directed.
S&F in repair Ball Bearing 6308 complete all as specified and directed.
S&F in repair Ball Bearing 6309 complete all as specified and directed.
S&F in repair Ball Bearing 6310 complete all as specified and directed.
S&F in repair Ball Bearing 6311complete all as specified and directed.
S&F in repair Ball Bearing 6312 complete all as specified and directed.
S&F in repair Ball Bearing 6313 complete all as specified and directed.
S&F in repair Ball Bearing 6314 complete all as specified and directed.
S&F in repair Roller Bearing NU-314 complete all as specified and directed.
S&F in repair Roller Bearing NU-316 complete all as specified and directed.
S&F in repair Double Ball Bearing 3307 complete all as specified and directed.
S&F in repair Double Ball Bearing 3309 complete all as specified and directed.
S&F in repair Roller Bearing 21309 complete all as specified and directed.
S&F in repair 3 pole power contactor type ML-1.5, 415 Volts, 50 HZ range 25 Amps complete all as specified and directed.
S&F in repair 3 pole power contactor type ML-2, 32 Amps, 415 Volts, 50 HZ complete all as specified and directed.
S&F in repair 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and directed.
S&F in repair Bimetal over load relay type ML 1.5, starter type MNX, relay range 14-23 Amp complete all as specified and directed.
S&F in repair Bimetal over load relay type ML 2, starter type MNX, relay range 20-32 Amps complete all as specified and directed.
S&F in repair Bimetal over load relay type ML 3, starter type MNX, relay range 28-42 Amps complete all as specified and directed.
S&F in repair Bimetal over load relay type ML 4/6, starter type MNX, relay range 45-75 Amps complete all as specified and directed.
S&F in repair Bimetal over load relay type ML 5, starter type MN, relay range 66-110 Amps CT operated complete all as specified and directed.
S&F in repair automatic star - delta starter with sheet enclosure pump controller with type MUG ML 1.5 , 415 volt complete all as specified and directed.
S&F in repair automatic star - delta starter with sheet enclosure pump controller with type MUG ML 2 ,415 volt complete all as specified and directed.
S&F in repair automatic star - delta starter with sheet enclosure pump controller with type MUG ML 3, 415 volt complete all as specified and directed.
S&F in repair automatic star - delta starter with sheet enclosure pump controller with type MUG ML 4, 415 volt complete all as specified and directed.
S&F in repair PVC insulated multistranded copper conductor wire of size 2.5 sqmm, single core, 1100 volts complete all as specified and directed.
All as per item ser No 307.00 above but size 4 sqmm
All as per item ser No 307.00 above but size 6 sqmm
All as per item ser No 307.00 above but size 10 sqmm
All as per item ser No 307.00 above but size 16 sqmm
All as per item ser No 307.00 above but size 25 sqmm
S&F in repair Indicating light RYG LED type complete all as specified and directed.
S&F in repair current transformer ratio 100/5 complete all as specified and directed.
S&F in repair current transformer ratio 200/5 complete all as specified and directed.
S&F in repair current transformer ratio 400/5 complete all as specified and directed.
S&F in repair MS foundation bolts with nuts and washers, size 20mm dia , 450 mm long including demolition of PCC/hard standing foundation complete all as specified and directed
S&F in repair Vibration Pad with nuts, bolts and washers for existing capacity of 20-30 HP complete all as specified and directed.
S&F in repair Vibration Pad with nuts, bolts and washers for existing capacity of 40-60 HP complete all as specified and directed.
S&F in repair Vibration Pad with nuts, bolts and washers for existing capacity of 60-100 HP complete all as specified and directed.
Disconnecting water pipe line , electric connection and taking out submersible pump set of any capacity alongwith column pipe and submersible cable and re-lowering the same after developing the bore well including replacement of rubber gasket , nuts,bolts and washer where ever required complete all as specified and directed. Note:- Development of borewells, rubber gasket , nuts,bolts and washers will be measured and paid under respective items of BOQ.
M&L for development of bore well of any capacity and size at the pressure 10 kgs/Sqcm to 15 kgs/Sqcm by diesel engine driven air compressor of capacity 620 cfm including air pipe and connected items to improve the yeild of tube well complete all as specified and directed. Note :- 1. Development of bore well shall be carried out by lowering 100 mm dia GI pipe and air pressure pipe shall be lowered in 100 mm GI pipe to protect the casing pipe of bore well from excess air pressure and it shall be arranged in such a way that discharge of water and mud flows through 100 mm dia GI pipe and not through bore well casing pipe. 2. The necessary T&P like air compressor with tools and accessories including transportation etc at different locations are deemed to be included in quoted rates.
Supply only in repair of mild steel nuts, bolts & washers etc of any size complete all as specified and directed.
Supply only in repair of rubber packing suitable for flange 50 mm dia complete all as specified and directed.
S&F in repair GI nipple with flange welded, heavy duty 50 x 300 mm size complete all as specified and directed.
Supplying , fixing & testing in replacement water proof submersible copper conductor cable of size, 4 sqmm, 3 core ,1100 Volts, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints after taking down/out old unserviceable submersible cable complete all as specified and directed.
S&F in repair MS tubing heavy duty,Class -C, column pipe, size 50 mm bore, 3 meter long, Conforming to IS-1239, coupled with heavy duty suitable size MS flanges 12mm thick duly welded on both sides with and including necessary nuts, bolts , washers , rubber packing etc and lowered into the bore well after taking down/out old unserviceable column pipe complete all as specified and directed. Notes: - (i) Length of each column pipe shall be 3 Mtrs. (ii) Taking down/out and Lowering of Submersible pump set shall be measured and paid separately.
S&F in repair CI Non return Valve of dia 50 mm with GM seat, PN-1.0 including flange joints such as packing, nut and bolts ISI Marked, as per IS:5312 complete all as specified and directed.
S&F in repair CI Non return Valve of dia 80 mm with GM seat, PN-1.0 including flange joints such as packing, nut and bolts ISI Marked, as per IS:5312 complete all as specified and directed.
S&F in repair cast iron Sluice Valve of dia 50 mm ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and directed.
Opening the submersible pump set of capacity upto 7.5 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. ,repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the pump set in original position with required insulating material to make it functional complete all as specified and directed. Note:- Winding wire required shall be measured & paid separately.
Supplying and assembling in repair super enamelled copper winding wire of appropriate gauge suitable upto 7.5 HP capacity submersible pump sets complete all as specified and directed.
S&F in repair mild steel casing cover, heavy duty made out of Mild Steel sheet not less than 6mm thick suitable for upto 200 mm bore pipe after taking down/out cap as existing at site complete all as specified and directed.
S&F in repair DOL starter for 7.5 HP complete all as specified and directed.
S&F in repair dial type 2400 hours timer, 16 Amps, SP, after taking down/out starter as existing at site complete all as specified and directed .
S&F in repair GM bearing bush upto 7.5 HP submersible pump set including taking down/out existing bush at site complete all as specified and directed.
All as per serial item No 338.00 above but cable seal
All as per serial item No 338.00 above but Motor base
All as per serial item No 338.00 above but Thrust bearing Housing
All as per serial item No 338.00 above but CI upper housing
All as per serial item No 338.00 above but CI lower housing
All as per serial item No 338.00 above but Adapter Piece
All as per serial item No 338.00 above but Rocker
All as per serial item No 338.00 above but revolving disc
All as per serial item No 338.00 above but Thrust bearing Axial
All as per serial item No 338.00 above but Water Seal
All as per serial item No 338.00 above but Set O ring
All as per serial item No 338.00 above but Nyloc Nut
All as per serial item No 338.00 above but Drain plug
All as per serial item No 338.00 above but Flange upper with stud and nut
All as per serial item No 338.00 above but Flange lower with stud and nut
All as per serial item No 338.00 above but pump sand guard
All as per serial item No 338.00 above but Rotor Sleeve
All as per serial item No 338.00 above but Circlip
All as per serial item No 338.00 above but sealing ring
All as per serial item No 338.00 above but Rotor sleeve turning and grinding
All as per serial item No 338.00 above but Remetling of rotor end turning including making key way
All as per serial item No 338.00 above but thrust plate
All as per serial item No 338.00 above but repairing of stamping of motor
All as per serial item No 338.00 above but T bolt with nut
All as per serial item No 338.00 above but Stud and nuts for connection piece
All as per serial item No 338.00 above but balancing of rotor
All as per serial item No 338.00 above but LNK bolts stainless steel
All as per serial item No 338.00 above but Submersible cable joint
All as per serial item No 338.00 above but EPV/SS diffuser
All as per serial item No 338.00 above but CI suction chamber
All as per serial item No 338.00 above but CI stage bowl
All as per serial item No 338.00 above but CI NRV
All as per serial item No 338.00 above but Pump coupling
All as per serial item No 338.00 above but Key for coupling
All as per serial item No 338.00 above but GM neck ring
All as per serial item No 338.00 above but Strainer SS wire mesh
All as per serial item No 338.00 above but EPV/SS Impeller
All as per serial item No 338.00 above but guide bush
All as per serial item No 338.00 above but DOL GM bush
All as per serial item No 338.00 above but stainless steel DOL sleeve
All as per serial item No 338.00 above but sand guard
All as per serial item No 338.00 above but CI DOL piece
All as per serial item No 338.00 above but Impeller key
All as per serial item No 338.00 above but stainless steel pump shaft single stage
All as per serial item No 338.00 above but stainless steel distance sleeve
All as per serial item No 338.00 above but hook bolt with nut
M&L for Sub class'B' brick, old size as in cable protection cover, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to the length of the brick, complete all as specified and directed.
Supply and spread clean dry river sand in trenches (8mm below & 15cm above the cable) including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
S&F in repair Submersible pump, 5 HP electric driven 415 V, TP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) including cable 4 Sqmm 3 core 40 metre long submersible cable and starter complete all as specified and directed.
Bocky system under path/road to pass the GI/CI/DI Pipes upto 100 mm dia manually complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron 4mm dia wire by means of GI nuts, bolts and washers. GI wire shall be laid in 25 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire 4mm dia (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
S&F in replacement earth continuity conductor or main earthing lead fixed to wall or batten or recess or chases or burried in ground or drawn in conduit/ pipe or any other indicated situation for loop earthing etc. as required 4 mm dia gavanised iron or steel wire complete all as specified and directed.
M&L dewatering, cleaning of 20000 gallons capacity reservoirs with high pressure jet incl lime wash on internal surfaces complete incl writing the date of cleaning of water tank in DD/MM/YYYY format using synthetic enamel paint with black border complete all as specified and directed with the following process:- (i) Dewatering the tank with portable submersible pump set. (ii) Removal of left over dirty water and sludge with special sludge removal pump set . (iii) Cleaning of wall ceiling and floor by high pressure rotary water jet . (iv) Removing of remaining sludge from the floor with the help of industrial vacuum cleaner. (v) Spraying of non toxic biodegraded eco friendly anti bacterial agent certified by a Govt approved lab to disinfect the tank from harmful bacteria. (vi) Weather proof exterior emulsion paint two coats on external surfaces after removing/ scraping old painted surfaces complete.
All as per item ser No. 391.00 above but 50,000 gallons capacity.
All as per item ser No. 391.00 above but service tank of capacity 20,000 Ltrs (RCC).
All as per item ser No. 391.00 above but service tank of capacity 10,000 Ltrs (RCC).
M&L for dewatering, cleaning of Service tank capacity 10000 ltrs (PVC) with high pressure jet incl lime wash internally complete including writing of the date of cleaning of the water tank with synthetic enamel paint complete all as specified and directed.
All as per item ser No . 395.00 above but Service tank of 5000 Ltrs (PVC).
All as per item ser No . 395.00 above but Service tank of 2000 Ltrs(PVC).
All as per item ser No 395.00 above but Service tank of 1000 Ltrs (PVC).
All as per item ser No . 395.00 above but Service tank of 500 Ltrs(PVC).
M&L in replacement of MS ERW pipe of bore 150 mm confirming to IS-1239 (Part I) 2004 (sixth version) & (Part II) 1992 (fourth version) medium grade complete all as specified and directed.
M&L in replacement of MS ERW pipe of bore 100 mm confirming to IS-1239 (Part I) 2004 (sixth version) & (Part II) 1992 (fourth version) medium grade complete all as specified and directed.
S&F in replacement SS (Stainless Steel) Single head landing valve with 80 mm N.B. flanged inlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290. Including fixing with anchor fastener and flanged tapping from wet riser complete all as specified and directed.
S&F in replacement of motor of domestic RO of capacity 100 GPD complete all as specified and directed.
S&F in replacement of SV-SLX- of domestic RO complete all as specified and directed.
S&F in replacement of Membrane ECO of domestic RO complete all as specified and directed.
S&F in replacement of Inline of domestic RO complete all as specified and directed.
S&F in replacement of UV LED of domestic RO complete all as specified and directed.
S&F in replacement of UV barrel of domestic RO complete all as specified and directed.
S&F in replacement of SMPS 24 of domestic RO complete all as specified and directed.
S&F in replacement of Membrane Houseing of domestic RO complete all as specified and directed.
S&F in replacement of Motor 150 GDP Industrial RO of capacity 25 ltr complete all as specified and directed.
S&F in replacement of HPS Industrial RO of capacity 25 ltr complete all as specified and directed.
S&F in replacement of NRV Industrial RO of capacity 25 ltr complete all as specified and directed.
S&F in replacement of SVSL Industrial RO of capacity 25 ltr complete all as specified and directed.
S&F in replacement of Membrane Industrial RO of capacity 25 ltr complete all as specified and directed.
S&F in replacement of SV SLX Industrial RO of capacity 50 ltr complete all as specified and directed.
S&F in replacement of Membrane ECO Industrial RO of capacity 50 ltr complete all as specified and directed.
S&F in replacement of 3/8'' elbow Industrial RO of capacity 50 ltr complete all as specified and directed.
S&F in replacement of SMPS (03 Amp) Industrial RO of capacity 50 ltr complete all as specified and directed.
S&Fin replacement of HPS Industrial RO of capacity 50 ltr complete all as specified and directed.
S&F in replacement of NRV Industrial RO of capacity 50 ltr complete all as specified and directed.
S&F CP hose 15m with all fittings complete all as specified and directed.
S&F RRL hose type- A 30mm with all fittings complete all as specified and directed.
S&F hose reel drum 30m complete all as specified and directed.
Fire alarm control panel comoplying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed.
Fire alarm control panel comoplying with BS EN 54 Single loop panel of capacity from 04 loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop) complete all as specified and directed.
Detectors complying with and type certified to EN-45 Addressable type smoke detector Photoelectric/Optical with base with self built intelligence as per IS:11360 complete all as specified and directed.
Detectors complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke comnination complete all as specified and directed.
Detectors complying with and type certified to EN-45 Addressable type heat detector with base with rate of rise cum fixed temperature as per IS:2175 complete all as specified and directed.
(i) Contractor shall be deploy a supervisor to collect the complained from KWC/Metcalfe House area by 0930 hrs every day and attend the complained and rectify the same within 24 hrs after noting/0930 hrs which ever is earlier neither Rs 50/- per working hrs will be recovered as a penality against each complained. It will be the preview of Engr-in-Charge to certify the complained beyond contractor capacity to rectify in 24 hrs in that case the penality clause not applicable on that particular complained. (ii) Work considered for multistories/High-rise Bldgs also, Hence contractor should ensure proper safety equipment be provided to the worker
V.V CONSTRUCTIONS
Pradeep Bros
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .