Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 CrAccepted-AOC 5 203A VINEET KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226 010 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226010 | ₹16.1 Cr Quoted ₹18.1 Cr | L1 | Accepted-AOC Financial Bid is Accepted at the Price of Rs. 160834040.24 by the Committee. |
| 2 | L2₹18.7 CrRejected-Finance | ₹18.7 Cr | L2 | Rejected-Finance Rejected Being Higher Rates. |
| 3 | Not Admitted-Fee/PreQual/Technical B 6 BALDA COLONY NISHATGANJ LUCKNOW 226007 | LUCKNOW | UTTAR PRADESH | 226007 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹28.5 L
Closing Date
24 Mar 2021, 12:00 pmClosed
SE, LUCKNOW CIRCLE, PWD, LUCKNOW
OFFICE OF SE, LUCKNOW CIRCLE, PWD, 96 M.G. ROAD HAZTARGANJ, LUCKNOW
Demolition of B Block Inspection house 12 Nos room, 02 Nos Dormitory and Generator Room and Construction Work in PWD Campus Lucknow
2021_CEUCZ_569537_1
1723/523C-PDL-LKO.CIR/2020-21 Dt. 09-03-2021
Open Tender
Civil Works - Buildings
90 days
OFFICE OF SE, LUCKNOW CIRCLE, PWD
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
₹28.5 L
Yes
OFFICE OF SE, LUCKNOW CIRCLE, PWD, 96 MG ROAD LKO
30 May 2021
18 Mar 2021
25 Mar 2021
18 Mar 2021
24 Mar 2021
18 Mar 2021
20 Mar 2021
Amount
PART-A (Civil) EXCAVATION in foundation in ordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m & including filling watering and ramming of excavated earth into the space between the building & sides of foundation trenches or into the plinth and removal & disposal surplus earth as directed by the engineer I/C within a lead of 30 m.from foundation trenches.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8.00Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distsnce of 50m out side the periphery of area cleared. under floor fine sand.
Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation and floors.
Extra for providing and mixing water proofing material in cement concrete per 50kg work in doses by weight of cement as per manufacturer's specification.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
All works above plinth level upto floor V level
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more
Brick work with common burnt clay (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement : 6 coarse sand) BASEMENT
TERRACE
Brick work with common burnt clay (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement : 4 coarse sand) EXTRA FOR HALF BRICK MASONARY BASEMENT
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with both side lamination of 1.0 mm & vertical grains or cross bands and face veneers on both faces of shutters. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 2nd Class Teak Wood
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with 1.0 mm thick decorative high pressure laminated sheet, on both faces of shutters, of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Circular
Providing and fixing stainless steel (Grade 304) railing made of hallow tubes, chanells, plates etc. including welding grinding buffing, polising and making corvechare (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge.(for payment purpose only weight of stainless steel members shall be considered excluding fixing assessories such as nuts, bolts, fasteners etc.
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 20 mm dia
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm.
Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm.
Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm.
Providing and fixing SS handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge Pre-laminated particle board with decorative lamination on both sides
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide palte etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness.
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing approved brand and manufacture SS 304 grade D type 1200mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles Equivalent brand of super quality in different size (Thickness specified by manufacturer) with water absorption make in all colors and shade laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand ) including grouting the joint with white cement and matching pigments etc. complete ( Size of Tile up to 600 x 600 mm)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing 18 mm thick gang saw cut, mirror polished, Bpremoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick Granite stone, including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and laying C.C. Trimix Flooring of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be aid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
Providing and fixing machine cut, mirror/ eggshell polished , Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.“ 18 mm thick Granite in any colour and shade.
12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall. BASEMENT
TERRACE
15 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On rough surface of wall. BASEMENT
TERRACE
12 mm thick plaster with cement mortar in consisting of 1:3 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. In ceiling BASEMENT
TERRACE
Painting two coats over priming coat on steel & other metal surface upto 10 cm width or grith or small articles not exceeding 0.10 sqmt. In areas with superior synthetic enamel such as Luxol 3Hi gloss aqcolite superlac. Dulux specified finishing
French spirit polishing : Two or more coats on new works including a coat of wood filler
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Add for plaster Grooves in plastered surface or moulding to R.C.C. projections
Add for plaster drip course in plastered surface or moulding to R.C.C. projections
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
Basement floor and side wall Double layer insulated waterproofing extruded polystrence and screed 75mm thick
P/F OF INDUSTRIAL TILE PARKING FLOORING FOR PROPER COMPLETTION OF WORK.As directed and specified by the Engineer-in-Charge :
BASEMENT TOP WATERPROOFING FOR LANDSCAPE
Cement Concrete Flooring 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate ) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete: 40mm thick with 20mm nominal size stone aggregate.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) in beam
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) in slab
15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1cement : 4 coarse sand)
Providing & Filling of O.B. brick ballast 25 mm to 40 mm size inside of upper layer in soak pit.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls where required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade
Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. 510x1040 mm bowl depth 200 mm
Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting Complete Flexible Pipe 32mm Dia
40mm Dia
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing soil, waste, vent pipes Centrifugally cast (spun) iron S&S pipe 100mm dia cast (spun) iron S&S pipe
Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe
Providing and fixing heel rest sanitary bend, in Centrifugally cast (spun) iron pipe S&S 100mm
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100X100X100mm Sand cast iron S&S as per IS : 3989
Providing and fixingPLAIN JUNCTION of required degree 100X100X100mm Sand cast iron S&S as per IS : 3989
Providing and fixing terminal guard: 100mm Sand cast iron S&S as per IS - 3989
Providing and fixing collar. 100mm Sand cast iron S&S as per IS - 3989
Providing and lead caulked joint 100 Dia
Providing and fixing cast iron trap of self cleansing design with cast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989
Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work 100mm dia
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms
Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work 40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 25mm dia, nominal bore
32 mm dia, nominal bore
40 mm dia, nominal bore
50 mm dia, nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 100 mm diameter
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) 15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality 40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work 40 mm dia, nominal bore
50 mm dia, nominal bore
65 mm dia, nominal bore
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 15mm nominal bore
20mm nominal bore
25mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 100x100 mm size P type With F.P.S. Bricks class designation 75
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia rcc pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 grade Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With F.P.S. bricks with class designation 150
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With F.P.S. bricks class designation 150
MODULAR KITCHEN
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 150 mm diameter P.V.C. pipe
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying HDPE PIPEwith 6 kg pressure including all assesaries such as valve,service saddle, tee band and trenching,backfilling , shifting of line ,making chamber ,jointing of pipe with butt fusion and testing complete as per desiser of engineer in charge. 160 MM
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 With F.P.S. bricks class designation 75 0.00 to 1.0 m depth
Providing and laying HDPE PIPEwith 6 kg pressure including all assesaries such as valve,service saddle, tee band and trenching,backfilling , shifting of line ,making chamber ,jointing of pipe with butt fusion and testing complete as per desiser of engineer in charge. Pipes, 200 mm dia. 0.00 to 1.5 m depth
Pipes, 315 mm dia. 1.50 to 3.0 m depth
Pipes, 450 mm dia. 1.50 to 3.0 m depth
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 0.00 to 1.0 m depth
1.01 to 1.5 m depth
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Granular Sub-Base with Close Graded Material (Table: 400-1): Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. For Grading-I Material (By Mix in Place Method).
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately.
Providing and fixing in position pre-moulded joint filler in expansion joints.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound.
Part B -Electrical BOQ Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 14 SWG copper earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash.
Wiring point for two ways light point with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 14 SWG copper earth continuity wire , GP box and two number two ways piano type switches & ceiling rose/angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc., complete in all respect,as directed, including matching colour wash.
Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 14 SWG copper earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet,etc.complete in all respect,as directed, including matching colour wash.
Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in riggid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 14 SWG copper earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash.
Wiring point for call bell with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 14 SWG copper earth continuity wire GP box and piano type bell push switch or two pin socket etc.complete in all respect,as directed, including matching colour wash.
Wiring point for Exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting complete with 14 SWG copper earth continuity wire , GP box and 15 amp piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc.complete in all respect,as directed, including matching colour wash.
Supply fixing & concealing of PVC conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of conduit and providing necessary socket ,bend & chucknuts,as directed by engineer incharge with the supply of material labour and T&P required for proper completion of work. Size 20 mm dia 16SWG (2 mm)thick
Same as in item 174 (B) but for plug point with 5 Amp. Flush type switch and 3 pin socket and earth continuity wire of 1.5 sq mm. FRLSH PVC insulated multi strand copper conductor cable.
Add for light /fan point with moduler type switch in place of piano type switch.
Add for 2 way light point with moduler type switch in place of piano type switch.
Add for plug point with moduler type switch in place of piano type switch.
Add for HPMV/Exhaust Fan point with moduler type switch in place of piano type switch.
Add for call bell point with moduler type switch in place of piano type switch.
Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing TV antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing Bell push outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing LAN socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supply & wiring of submains with 2 nos.1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1-nos. 14 SWG copper earth continuity wire including matching colour wash etc.complete in all respect.
Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 1-nos. 14 SWG copper earth continuity earth continuity wire including matching colour wash etc.complete in all respect.
Supply & wiring of submains with 2 nos.4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1- nos. 14 SWG copper earth continuity wire including matching colour wash etc.complete in all respect.
Supply & wiring of submains with 4 nos. 6 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2-nos. 14 SWG copper earth continuity wire including maching colour wash etc.complete in all respect.
Supply & wiring of submains with 4 nos.10 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2-nos. 10 SWG copper earth continuity wire including matching colour wash etc.complete in all respect.
Supply & fixing and making connection of 40 amp. 4P 30 mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge.
Supply & fixing of Batton/Angle holder including making connection etc. as required.
Supply & fixing of single wall light bracket made of brass on matching polished MDFEG board brass including connection etc. as required. CAT. AAA
Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 2420 system lumens, 110 Im/W, PF>0.95, THD<10%, CRI>80, sheet Thickness 0.8 mm, Tube with aluminium heat with 5 year warrantee
Supply and fixing of LED Tube Light with batten suitable for up to 2x22 watt LED tube light Complete including tube etc on surface complete in all respect. CAT. - AAA
Supply and fixing of water tight oblong 10 Watt LED bulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 1100 system lumens, 110 Im/W, PF>0.95 with 5 year warrantee
Supply and fixing of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. CAT. - AAA 1100-1650 system lumens, 1101m/W, PF>0.95, THD<10% at full load, CRI>80, with 5 year warrantee
Supply and fixing of recess mounting round 15 to 18 Watt LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. Complete in all respect. CAT. - AAA
Supply and fixing of 2'x2' 36 W to 46 W indoor recess/surface mounting LED Square Fitting for Armstrong Ceiling having powder coated CRCA housing body diffuser of special polycarbonate material and driver set Complete in all respect. CAT. - AAA
Supply and fixing of factory wired integral LED flood light luminires with die cast aluminium housing built with driver set suitable for 100 W TO 120W . Conforming to IP 65 protection complete in all respect.
Supply and fixing of 3 watt to 6 watt LED Decorative mirror light (spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA 330-660 system lumens 1101m/W, PF>0.95, THD<20% at full load , with 5 year warrantee
Supply and fixing of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including making connection.Complete in all respect.
Supply of ceilling fans with fan motor of A.C. Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200 mm sweep
Supply & Fixing of AC 1400mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulator, standar down rod, blades etc. complete as required. (Standard - Plain Ceiling Fans)
Supply and fixing of 400mm sweep, wall mounted fan complete with double ball bearing, motor, blades, capacitor etc suitable for single phase 230 volts, 50 Hz., AC supply, complete as required.
Supply and fixing of AC 230mm Sweep, 230/250 Volts, 50 Hz exhaust fan (light Duty) with blades,cover etc. complete as required
Supply and fixing of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Heavy Duty) with blades,cover etc. complete as required
Supply and fixing of call bell of approved make on polished MDFEG / Teak ply board including making connections etc.complete in all respect.
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size size 16 sq mm x 4 core
size 35 sq mm x 3-1/2core
size 185 sq mm x 3-1/2core
Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable size 16 sq mm x 4 core
size 35 sq mm x 3-1/2core
size 185 sq mm x 3-1/2core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 16 sq mm
size 35 sq mm
size 185 sq mm
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated,Length 3000mm,outer pipe 48.4mmx3.2mm,inner pipe 26.9mm x 2.6 mm,terminal Dia 12mm,coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified.
Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia
100 mm dia
Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A
Supply and fixing of 240 volts C Curve 40 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A
Supply and fixing of flush/surface mounting 4 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A
Supply and fixing of flush/surface mounting 6 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A
Supply and fixing of flush/surface mounting 8 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A
Supply & Fixing of MCB blanking plate for DB.
Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
Erection and testing of ceiling fan and regulator for room height above 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.exra for per 15 cm hight
Erection and testing of exhaust fan on the existing hole with suitable size rag bolt nut & washer etc. complete in all respects.
Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finshing propely complete in all respect.
Supply and Fixing of shock treatment chart.prescribed as per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work.
Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules
Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work.
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.
Supply fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
Supplying and drawing FR PVC insulated annealed copper conductor, unarmoured cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and drawing Co axial T V cable, RG-6 grade, 0.7 mm solid copper conductor, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 14 SWG copper earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash. Two Loop
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Same as in item 174 (B) but for plug point with 5 Amp. Flush type switch and 3 pin socket and earth continuity wire of 1.5 sq mm. FRLSH PVC insulated multi strand copper conductor cable.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head
Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts.
Providing and Fixing M.S Structural Work fabricaed from standard sections e.g MS rounds, angles, channels including cutting to size, drilling, welding, fixing and welding to insert plates in RCC structural members as directed by Engineer-in-Charge including cutting and making good the walls and floors (For sprinkler Pipe support etc.). Tie Road 10 mm
Angle Frame 35 / 40 mm x 5 mm
Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site.
Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 14 SWG copper earth continuity earth continuity wire including matching colour wash etc.complete in all respect. 150 mm dia
Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2.
Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :- 80 mm dia
150 mm dia
Supplying, Installation, Testing and Commissioning of Annunciation Panel made out of not less 1.6 mm thick CRCA sheet powder coated in approved colour with locking arrangement, audio and visual indication of fault and operation of automatic sprinkler, system monitoring including providing and fixing the following, connections interconnections etc. complete as required. The Panel shall be Micro processor type/solid state type.*Monitoring the open circuit, short circuit & earth fault in control cable between panel and flow switches. Monitoring upto 8 Nos. of flow switch
Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass connection to drain pipe/riser.
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets). 4 nos.Fire Bucket Without canopy
supplying, Installtion, testing and commissioning of electrical control panel of cubicle construction, floor/ wall mounted type, fabricated out of 2 mm thick CRCA sheet,compartmentalised with hinged locakable doors,dust and vermin proof,powder coated fabricated out of 2 mm thick CRCA sheet,compartmentalised with hinged locakable doors,dust and vermin proof,powder coated of approved shade after 7 tank treatment process,cable alley,inter connection,having switchgears and access ories mounting and internal wiring,earth terminals numbering etc. complete in all respects,suitable Outlet Piping Stop Ball Cock, Drain Valve, Drain Pipe Air Check Valve protection class IP 42 as required.for terrace,Roof Cover over panel. Make :– CPRI Approved (Fault Level, IP Level Protection) (Component- L&T / G.E) Panel for 7.5 HP.
Providing & Fixing of 1.6 mm thick M.S / Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making Recessed type mansoary box (by civil contractor). 2100x900 mm (Indoor Cabinet)
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 80 mm dia
100 mm dia
150 mm dia
Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
100 mm dia
150 mm dia
Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia
100 mm dia
150 mm dia
Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 80 mm dia
100 mm dia
150 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe
4 way - 150 mm dia M.S. Pipe
Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required.
Providing & fixing Flow Switch in following sizes M.S. pipe including connection etc as required. 100mm dia
150mm dia
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size size 16 sq mm x 4 core
size 35 sq mm x 3-1/2 core
Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable size 16 sq mm x 4 core
size 35 sq mm x 3-1/2 core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 16 sq mm
size 32 sq mm
20 Passenger Lift Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 14 SWG copper earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash. Other Features Battery Operated Emergency Light And Alarm Bell False Ceiling In Car Vandal Proof S.S. Button With S.S. Cover Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in riggid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 14 SWG copper earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash. Infra Red Door Screen Full Car Operating Panel 3 Way Intercom / Press And Speak Phone Push Button - Orange L E D Illumination Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour Automatic Rescue Device Minor Builders Work Scaffolding
Supply of Hoist Beam : 100 kg/m
Add Extra for Supply of Trap Door : 50 kg/sqm
Add for Scaffholding & Other Building Work (Cutting, Chipping And Repairing etc.) Cable etc.
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size size 35 sq mm x 3-1/2core
size 50 sq mm x 3-1/2core
Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable size 35 sq mm x 3-1/2core
Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 14 SWG copper earth continuity earth continuity wire including matching colour wash etc.complete in all respect.
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 35 sq mm
size 50 sq mm
Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated,Length 3000mm,outer pipe 48.4mmx3.2mm,inner pipe 26.9mm x 2.6 mm,terminal Dia 12mm,coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified.
Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia
100 mm dia
S&F of 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. CAT B
Supply and fixing of 240 volts C Cure 6-32 amp SP miniature circuit breaker (10KA) inexiting MCB, DB complete with connections as required CAT A
Supply and fixing of flush/surface mounting 4 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A
Supply & fixing and making connection of 63 amp. 100mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge.
Supply, Instalaltion, testing and commissioning of Modular type outdoor units equipped with highly efficient scroll compressors with all inverter compressor(s), special heat exchanger, centrifugal fan for condenser, ODU having front suction & top discharge, Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting and capacity as mentioned below. VRF System shall be suitable for working on 48 °C ambient temperature, Refrigerant R 410A. 18 HP Heat Pump Unit
16 HP Heat Pump Unit (8 HP x 2 Nos.)
Supply, Instalaltion, testing and commissioning of Indoor units equipped with pre-filter, fan section with suitable static fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities. 2 TR Cassette Type VRV Indoor Unit
3.3 TR Cassette Type VRV Indoor Unit
Supply, installation, testing & commissioning of Factory Fabricated Floor Mounted Type Double Skin AHUS complete with Fan Section, Fan Motor, Cooling Coil with Coil Section, without face and by pass dampers complete with backward curved blower, blower section filter section with Pre- filters, 5 Micron fine filter complete with motor, drive package etc. the capacity of the Air Handling Units suitable for 125-130 mm WG Static Pressure with 6Row Deep Cooling Coil. 3500 CFM Capacity
Supply, Instalaltion, testing and commissioning of Y-joints.
Supply, Installation, Testing & Commissioning of Corded Self Diagnostic Type Remote Controllers.
Supply, Installation, Testing & Commissioning of Expansion Valve kit with control box suitable for AHU.
Supply, installation, testing and commissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R 410A duly insulated with elastomeric nitrile rubber type tubular insulation of density 55+/-10% Kg/m3 between indoor & outdoor units as per specifications. 22.2 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 19 mm thick)
19.1 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
15.9 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
12.7 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
9.5 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
6.4 mm O.D. (Min. Wall Thickness - 0.80 mm, insulation - 13 mm thick)
Supply, installation, testing and commissioning of PVC condensate drain water piping complete with fittings like elbows, tees, reducers, bends, flanges, supports, insulation etc. as required and of following sizes. 25 mm dia pipe, Insulation Thickness - 9 mm
32 mm dia pipe, Insulation Thickness - 9 mm
40 mm dia pipe, Insulation Thickness - 9 mm
50 mm dia pipe, Insulation Thickness - 9 mm
Supply & fixing of UV Treatment for Exposed piping with Glass Cloth covered with UV Paint.
Supply, fabrication and installation of Aluminum Ducting Of: 20 Guage
Supply & fixing of Duct insulation with Crossed Linked Closed Cell Polyethylene Insulation for Supply and Return Air Duct. 15mm
Supply & fixing of Duct acoustic lining with 25 mm thick crown 2000 Resin bonded glass wool covererd with RP tissue paper & 26 G Al. perforated sheet.
Supply & installation of Powder Coated Aluminium Grills/Diffusers Supply/Return/Exhaust Air Linear Grille
Aluminum Volume Control Damper
Supply & Installation of GI Fire Damper with Fusible link
Supply & installation of Fresh Air Arrangement for Fresh Air AHUs comprising of fresh air intake louver with cowl, volume control damper etc. complete in all respect.
Supply & Installation of Fire retardant Canvass connection
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. A) Power cabling (XLPE insulated Aluminium / Copper conductor as given below cables of 1.1 KV Grade) including cable end termination with brass compression glands & lugs etc as per specification. 4C x 6 Sq. mm Copper Conductor
3C x 2.5 Sq. mm Copper Conductor
Providing & fixing of control cum trans-mission wiring of copper between indoor and outdoor unit in 25 mm PVC Conduit. 2C x 1.5 Sq mm
Supply and installation of GI perforated cable tray with required GI bend, reducer, cross, tee etc. including GI threaded hanger / channel support of following sizes. 150 mm x 50 mm
300 mm x 50 mm
Supply, fabrication & Erection of MS stand including foundation complete is all respect.
Supply & fixingof 6.0 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) in 1:2:4 RCC foundation includingthe cost of foundation,foundation bolts,excavation & back filling and Required T&P completee in all respect.
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT AAA
Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A
supply and fixing of 25 amp TPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors , HRC fuse , isolating switch , metering instrument and instrument box with CTs etc.complete in all respect.
Supply and fixing of 12.5 mtr High mast Pole of approved make with rising system, hot dip Galvanized inside & outside , having pole sheet thickness 3mm, top minimum100mm, bottom dia minimum 310mm, base plate 25mm thick, suitable for wind velocity as per IS 875 part 3. & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes,0.75 HP Power tool motor, 3 point suspension system with steel wire rope 6mm dia , double drum winch Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers , anchor plates etc Complete in all respect. as per direction and satisfaction to the Engineer-in-charge.
Supply and fixing of factory wired integeral LED flood light luminaires die cast aluminium housing built with driver set suitable for 170 to 200 Watt. Confirming to IP 66 protection Complete in all respect. CAT. AAA
supply and fixing of 15 amp TPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors , HRC fuse , isolating switch , metering instrument and instrument box with CTs etc.complete in all respect.
Supply and burying of 40mm dia x 4.5 metres long G.I. pipe vertically for earthing having 12mm dia. Holes spaced 75mm aoart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in GI pipe up to apporn(and from apporn to switch board the cast of G.I. wire and pipe will be extra) upto switch board 30 cm square C.I. box with hinged the cover masonary enclosure, funnel at top , alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per direction of Engineer-in-charge complete in all respect as per drawing.
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size size 6 sq mm x 2 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable size 6 sq mm x 2 core
size 10 sq mm x 4 core
size 16 sq mm x 4 core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 6 sq mm
size 10 sq mm
size 16 sq mm
Supply , Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, deisel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator air cooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and high temperature tripping. The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class "H" or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables DG Set Compatible for synchronising Panel 400 KVA
Supply and burying of 600mm x 600 mmx 6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 80 mm dia
Add Extra For Rcc Foundation Work for D.G Set Including Cost of Exhaust Pipe with Structure and Other Misc. Work and T&P etc. Complete in All Respect as Per Directed By Engineer In Charge.
M/S GOMDHARI
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid