Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹14.6 L+₹48,689 (3.44%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.6 L+₹1.5 L (10.6%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹16.0 L+₹1.8 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹16.4 L+₹2.3 L (16.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Oct 2023, 6:00 pmClosed
GE (AF) Bhisiana
GE (AF) Bhisiana PIN-151201
As per BOQ/ Price Schedule
2023_MES_619286_1
GE/BHI/T-94/2023-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Bhisiana
As per NIT/ Tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Bhisiana
₹30,000
Yes
13 Dec 2023
18 Sept 2023
18 Oct 2023
18 Sept 2023
16 Oct 2023
3 Oct 2023
18 Sept 2023 - 14 Oct 2023
Amount
Supply , laying , Jointing and testing in replacement XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
Supply , laying , Jointing and testing in replacement XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil complete all as specified and directed by Engineer in Charge.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer in Charge.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer in Charge.
M&L Sand Cushioning (Fazilka Dry Sand)) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the Purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for Brick protection cover of Under Ground cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed by Engineer in Charge.
Supply and fix in replacement LED electronic driver suitable for 60 Watt LED as light sources incluing taking down and old fitting as per repairing requirement complete all as specified & directed by Engr-in-Charge.
Supply and fix in replacement LED electronic driver suitable for 45 Watt LED as light sources,incluing taking down and old fitting as per repairing requirement complete all as specified & directed by Engr-in-Charge.
Supply and fix in replacement LED post top lantern with die cast aluminium spigot,spun aluminium,powder coated top cover acrylic diffuser IP 65 protection class of 25/30 watt fitted on the piller with the help of GI pipe/PCC work/nut bolts and connection with 2.5 sqmm 3 core copper cable including all fixing accessories complete all as specified and directed Engr-in-Charge.
M&L in replacement for highly efficient LED street light 90 watt luminaries new generation energy saving & environment friendly with lens made of pressure die cast aluminium alloy housing LM24 for gear and exturded alluminium lamp housing & enclouser with toughened glass with IP-66 of protection class,with high power LEDs as light source having luminous efficiency should be > 80Lm/w with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) . It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm fitted on pole/building with GI bracket of suitable size and connection with 2.5 sqmm 3 core wire upto bus bar of OH line/PVC Jn box/ LT panel /building for connection including taking down of unserviceable light fitting of any type/size complete all as specified and directed Engr-in-Charge.
S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting with Bus Bar and flexible conduit including taking down unserviceable Cable of any description, complete all as specified and as directed.
M&L in replacement for highly efficient integral type LED flood light 60 watt new generation energy saving & environment friendly made of pressure die cast aluminium with lens & enclouser with toughened glass with IP-66 of protection class,with high power LEDs as light source having luminous efficiency should be > 80Lm/w with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) . It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm fitted on pole/building with GI bracket of suitable size and connection with 2.5 sqmm 3 core wire upto bus bar of OH line/PVC Jn box/ LT panel /building for connection including taking down of u/s light fitting of any type/sizecomplete all as specified and directed Engr-in-Charge.
M&L for Scraping down and removing of old deteroirated paint from existing steel tubular poles above ground level,preparing surface for painting,applying two coats of aluminium paint upto full height of pole including MS clamps, GI brackets, fittting etc.complete all as directed at site including black and white strips of 30cms each upto 1.5 mtrs above PCC with black and white paint and marking of pole No. 2 Mtr above PCC , Cutter shoud not be long than 6 cms height as 16 cm dia circle around the marker number complete all as directed by Engr-in-charge.
M&L for Welding of existing LT Panel/bus bar Chamber/Junction boxes with the help of welding machine, after filing nuts,bolts,etc. including locking arrangement and applying one coat of synthetic enamel ivory paint(Smoke grey) to steel surface after disconnecting the electrical connections and reconnection the same at various sites by taking safety precautions after painting complete as specified and directed by Engr-in-Charge.
M&L in replacement Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including GI strip of size 32x6mm upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed by Engineer in Charge.
S&F in replacement of PVC Pole Mounted Junction Box 250x250mm, having 04 Nos of aluminium bus bar mounted on insulator with the help of nut,bolts, clamps including single pole MCB of 6 amps, 2.5 sqmm copper conductors cable 3 core for connection of incoming and outgoing cables complete all as specified and directed by Engineer-in charge
S&F in replacement of sheet metal(MS) bus bar box single door,outdoor type weather proof, size 300x300x200mm mounted on ground with iron angles(25x25x4mm). Having alluminium bus bar 4 nos, rated 100amp all as specified & directed by Eng-in-charge.
M&L for highly efficient integral type LED flood light 200 watt energy saving & environment friendly made of pressure die cast aluminium with lens & enclouser with toughened glass with IP-66 of protection class,with high power LEDs as light source having luminous efficiency should not be less 90 lumen with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) . It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire copper conductor 3 x 4.0 Sqmm fitted on high Mast pole including connection and taking down of old unserviceable light fitting complete all as specified and directed Engr-in-Charge.
M&L for preventive maintenance of existing EOT crane at height of 20 to 22 Metre (Approx) from representative of firm as approved by GE Including-(i) dismantling of hoisting gear box, (ii) drain of old oil, (iii) Cleaning & Greasing of gear box long travel and cross travel and refilling of fresh oil (iv) Fill up fresh oil in gear box (v) Checking of hoisting, long travel, cross travel, brake unit ,oiling of brake unit pins. greasing of long travel cross travel wheel bearing,checking of panel board and connections ,checking of rail alignment,checking of cross travel alignment.checking and oiling greasing of wire rope, rope drum,pedstal bearings,load test using dead weight and any minor defects all connections Electrical/Mechanical components, Including any minor repair deemed to be included in the above quoted rate complete all as specified and directed by Eng- in-charge. NOTE:- (i) All Work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii) Contractor shall provide necessary T&P, safety Equipments oil,grease, gear box oil, cloth waste and minor spare required and any other Material required for execution will be deemed to be in quoted unit rate. (iii) Approval of the firm shall be taken from GE before works commencement.
M&L for maintenance of existing traffic control barrier,including:- winding of 0.5 HP electric motor,wiring of control panel,replacement of control switches, repairing & greasing of mechanical unit & gear box mechanism,painting work & fabrication work required. including (i) 6 Sqmm XLPE Cable100 RM for Electric supply (ii) 2.5 Sqmm 3 core copper cunductor100RM (ii) Excavation work for both supply cable and signal cable etc.complete all as specified and directed by engg- in-charge. Note:-This job included all electrical and mechanical items require to make the road barrier in serviceable condition.
S&F PVC insulated Multi Stranded Copper Conductor Cable 6 Sqmm 4 Core, Round Flexible for connection with circuit including taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F PVC insulated Multi Stranded Copper Conductor Cable 4 Sqmm 3 Core, Round Flexible for connection with circuit including taking down unserviceable Cable of any description, complete all as specified and as directed by Engineer in Charge.
Material and labour for contactor of coil voltage 110 volt model MNX 25 including taking down unserviceable Contactor of any description, complete all as specified and directed by Engineer in Charge.
Material and labour for single phase preventor including taking down unserviceable Preventor of any description, complete all as specified and directed by Engineer in Charge.
Material and labour for suitable Rocker holder of EOT Crane 2 ton including taking down unserviceable Rocket Holder of any description, complete all as specified and directed by Engineer in Charge. .
Material and labour for IEC style control relay , 24 V DC, 10A and 18 pins including taking down unserviceable IEC Style control Relay of any description, complete all as specified and directed by Engineer in Charge.
M&L in replacement VFD for 2 Ton EOT crane 1.5 KW, 2 HP including connection and testing complete all as specified and directed by Eng- in-charge. NOTE:- (i)All work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii)contractor shall provide necessary oil,grease, gear box oil, cloth waste and minor spare required will deemed to be in quoted rate. (iii) The Contractor shall replace the VFD in control panel which is 20-22 Mtr height from ground.
M&L in replacement VFD for 2 Ton EOT crane 2.2 KW, 3 HP including connection and testing complete all as specified and directed by Eng- in-charge. t NOTE:- (i)All work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii)contractor shall provide necessary oil,grease, gear box oil, cloth waste and minor spare required will be deemed to be in quoted rate. (iii) The Contractor shall replace the VFD in control panel which is 20-22 Mtr height from ground.
M&L in replacement of VFD for 2 Ton EOT crane5.5 KW, 7.5HP including connection and testing complete all as specified and directed by Eng- in-charge. NOTE:- (i)All work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii)contractor shall provide necessary oil,grease, gear box oil, cloth waste and minor spare required will be deemed to be in quoted rate. (iii)The Contractor shall replace the VFD in control panel which is 20-22 Mtr height from ground.
REYANSH GARG AND COMPANY
M/s Luxmi Constructions
classic estate developers
Rasvinderpalandco
KAY VEE CONSTRUCTIONS
SHAKTI SINGH CONTRACTOR
GUPTA AND ENGINEERS
M/s BALDEV SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .