| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.4 L+₹5.5 L (27.4%)Rejected-Finance | L2 | Rejected-Finance Rejected due other than L1 | |
| 3 | L3₹26.4 L+₹6.5 L (32.4%)Rejected-Finance | L3 | Rejected-Finance Rejected due other than L1 | |
| 4 | L4₹26.5 L+₹6.6 L (32.9%)Rejected-Finance | L4 | Rejected-Finance Rejected due other than L1 | |
| 5 | L5₹27.5 L+₹7.5 L (37.6%)Rejected-Finance | L5 | Rejected-Finance Rejected due other than L1 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
8 Oct 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL BIRENDRA SINGH
GE 859 EWS, C/O 99 APO
REPAIR AND MAINT OF MISC E/M SERVICE AND OTHER ALLIED WORKS AT BDE, MBSC STN HQ, ENGR REGT, IFSU, IV DET CISU AND FD REGT OF AGE E/M UNDER GE 859 EWS
2024_MES_664524_2
8829/E8
Open Tender
Civil Works
Item Rate
270 days
TAWANG
PLEASE REFER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹0
₹38,000
Yes
26 Dec 2024
17 Sept 2024
9 Oct 2024
17 Sept 2024
8 Oct 2024
1 Oct 2024
Amount
Dismantling and taking up or down old Unserviceable service cable amd LT UG cable of any size complete all as specified and directed
Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of 10 Sqmm 2 core cross-sectional area
All item as per ser No 2 but for 10 Sqmm 4 Core
Excavation in trenches, n exc 1.5m wide and m exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for soft & loose soil.
Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for hard/dense soil.
Removing excavated material n exc. 50 m and depositing where directed at a layers not exc 25 cm. for hard/dense soil.
S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm
M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed..
M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified.
M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified.
Supply and fix in repair LT Over over head line phase seperator of any size (2 way) in between distribution span of LT over head lines all as directed by Engr-in-charge
Supply and fix cable jointing kit for 11 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for following sizes,Outdoor type 10 to 16 sqmm 3.5/4 Core
All as per item No 12 but for 25 to 50 sqmm 3.5/ 4 Core
M&L for locating of electrical fault in UG cable of any size and repair by using of suitable size of cable lugs and straight through joint and make the good disturbed surfaces all as specified and directed by Engr-in-charge. Note :- Cable joint kit,Earth work & Aluminium lugs will be measured and paid seperately in respective items.
Supply and fix in repair bracket for street light fitting made out of 32 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole complete including taking down old or Old U/S bracket from the pole as directed.
Supply and fix in repair weather proof PVC junction box approved by CPRI street light control box made out of not less than 2mm thick of size 200mm x 140 mm x 95mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole MCB 6A 10KA 01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed
Taking down unserviceable street light LED fitting/Flood light of any wattage and type from the pole/building of any height including disconnecting the cable connections for repairing of light fittings and refixing in same position all as specified and directed. Note : 1. Spares shall be measured and paid seperatly under relevent items.2. The cost of replacing of internal connections, screws bolts etc shall deemed to be included in the repair cost.
Supply only Electronic Driver for street light/Flood light fitting 25 to 50 Watts
Supply and fix Electronic Driver for street light fitting/Flood light fitting 60 to 100 watts
Supply only LED plate for street light/Flood light fitting 25 to 50 Watts
Supply and fix LED plate for street light fitting/Flood light fitting 60 to 100 watts
Repairs to LED Garden/Post top lantern/path light fitting of any wattage and type on existing Wall / pole of any height and making serviceable condition all as directed.Note : 1. Spares shall be measured and paid seperatly under relevent items. 2. The cost of replacing of internal connections, screws bolts etc shall deemed to be included in the repair cost.
Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 5 to 15 Watts
Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 20 to 45 Watts
Supply only LED plate for Garden/Post top lantern/Path light fitting 5 to 15 Watts
Supply only LED plate for Garden/Post top lantern/Path light fitting 20 to 45 Watts
M&L for Wiring for circuit/submain wiring 2 x 1.5 sq mm alongwith earth wire 1.5 sqmm with the of FRLS is PVC insulated copper conductor, single core cable in from junction box to street/flood light fitting on pole of any height as required all as specified and directed by engr in charge. Note:-Two run of cable copper conductor and non metallic PVC Rigid/ flexiable conduit(20mm dia) shall be measured as one unit length.
Supply and fixing in repair LED post top lantern fitting 40 watts on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc. including taking down existing fittings all as directed (Make :Havells Cat part No RUBYPT40WLED757PSYMTOPC or CG Cat part No LPTO-40-CDL or equivalent Wipro/bajaj
Supply and fixing in repair LED garden light 8 watt Pressure die cast powder coated housing with PC diffuser.Efficient high output LED with IP65 protection as existing fitting on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc. including taking down existing fittings all as directed (Make :Havells Cat Part No -BAMBOOBLS8WLED830PSYMTOPC or equivelant in CG/Wipro/bajaj
Supply and fix in Repair LED flood light fitting 70 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 70 W.including taking down old and unserviceable. Make :Havells Cat No: JETAALBAFLOODLIGHT70W or equivalent in Philips/CG
All as per item No 30 here -in-brfore but LED flood light 100 Watt.including taking down old and unserviceable. Make : Cat No: JETAALBAFLOODLIGHT100W of Havells or equivalent in Philips/CG
Supply and fix in repair of LED street light 45 Watt fitting,environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07.Make : Cat Part No TRP-409-45-57-SL-NS-GL-NSG of CG or equivalent in Philips/CG/Havells
All as per item no.32 here-in-before but of capacity 60 watts. Make : TRP-409-60-57-SL-GL-NSG of CG or equivalent in Havells/Philips
All as per item no.32 here-in-before but of capacity 70 watts. Make : TRP-409-70-57-SL-GL-NSG of CG or equivalent in Havells/Philips
M&L cutting the road hard standing & making good surface with PCC 1:3:6 C-1 Type Using 20 mm graded stone aggregate & removing the to distance n.exe 50mtr all as specified.
Supply and fix in repair street light Time switches Digital 24 hour, 440 V 2 pole 32 Amps including taking down the old u/s one complete all as specified and as directed.Make: Havells cat part No DHTQB01016 or equivelant in Legrand/L&T
M&L for carrying out 'B' check comprising replacement of fuel filters,oil filters,air filter element,changing lubricating oil,cleaning of fuel lines,checking leakges if any repair the leakge ,replacement of exhaust fan,gasket etc complete all as spoecified and directed for DG set 62.5 KVA complete all as specified and directed.
All as per item No 37 here-in-before but DG Set capacity 10 KVA
All as per item No 37 here-in-before but DG Set capacity 160 KVA
S&F in repair AVR with functions to adjust generator output voltage ,prevent voltage hunting,set under frequency,roll of knee point,set generator drop to 5% at full load,match AVR input to necessary output,set the over excitation cut off level ,set initial frequency ,related voltage dip,over voltage protection cut off level,max short circuit current with sensing input voltage range 170 - 250 V AC max,50-60 Hz frequency with out put max up to 120 V DC,countinious current 2.7 A & transient 6 A for 10 second including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG set of capacity 62.5 KVA all as specified and directed by Engr in charge
All as per item No 40 here-in-before but DG Set capacity 160 KVA
S&F in repair the unserviceable V belt of DG set capacity 62.5 KVA
S&F in repair the unserviceable V belt of DG set capacity 160 KVA
M&L for reconditioning of unserviceable battery of capacity 12 Volt 180 AH by replacing complete cells,PVC seperators,electrolyte,terminals and final sealing ,rechargeing,battery lead,and testing all as specified and directed.
S & F in repair of SMF sealed battery of 12 volts 26 AH capacity for the UPS all as specified and directed.
M&L for repair of self starter after removing from the DG set of capacity 62.5 KVA of any make and model all as specified and directed.
M&L for repair of self starter after removing from the DG set of capacity 160 KVA of any make and model all as specified and directed.
M&L for repair of dynamo after removing from the DG set of capacity 62.5 KVA of any make and model all as specified and directed.
M&L for repair of dynamo after removing from the DG set of capacity 10 KVA of any make and model all as specified and directed.
S&F of electrolyte for lead acid battery
S&F of distiled water for lead acid battery
S&F in repair diode of DG set of capacity 62.5 KVA
S&F in repair diode of DG set of capacity 160 KVA
M&L for repair/servicing of UPS of capacity upto 5 KVA by checking all electrical connection and rewiring the same and refix the same location or directed by Engr in charge including testing,commissioning and warranty of one year after date if repearing. Note:- (i) PCB kit,SMPS and By pass switch etc will be measured and paid sepeartaly .(ii) Minor parts e.g nut bolt screw wirng etc
M&L for PCB kit of UPS up to capacity of 5 KVA
M&L for bypass switch of UPS up to capacity of 5 KVA
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm
All as per item No above 57 but of size 6 sqmm
M/S TENZIN CONSTRUCTION (BID ID -3132049)
M/S DOLKO ENTERPRISES BOMDILA (BID ID -3132067)
M/S P K ENTERPRISES (BID ID -3132065)
M/S SONAM CONSTRUCTION (BID ID -3132052)
M/S REGI SEKANG ENTERPRISES (BID ID -3132070)
M/S R N ENTERPRISES (BID ID -3132060)
Sikha Traders (BID ID -3132058)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .