| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.4 LAccepted-AOC H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | ₹65.4 L Quoted ₹66.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹67.0 LRejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹67.0 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹67.8 LRejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹67.8 L | L3 | Rejected-Finance Being L3 |
| 4 | L4₹69.9 LRejected-Finance | ₹69.9 L | L4 | Rejected-Finance Being L4 |
| 5 | L5₹71.7 LRejected-Finance | ₹71.7 L | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | M/s Prem Associates L6 | M/s Devendera construction L1 | Raman Electric Trading Co L3 | Vijay Electricals L8 | malik constructions L4 | MAHESH KUMAR SINGLA CONTRACTOR L2 | R D Bansal L7 | FOUJI ELECTRIC WORKS L5 | M/s Kang Builders & Developers L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Installation,testing and commissioning of platform mounted transformer 160 KVA, 11/0.433KV, 50 Hz, step down, outdoor type, ONAN Cooled oil immersed copper wound energy efficient transformer, complete with first filling of IS-335 ISI marked filtered & dehyrated tranformer oil and other standard fittings/acceesories and 7 position OFF load circuit tap changer (Tapping range + 7.5% in steps of 2.5% Each) with vector group Dyn-11, with provision of HV and LV cable box suitable for making connection of incomming HT cable and outgoing LT cable all as per IS 1180-2014 (Level-2) and complet with and including all required accessories for installation of transformer all as specified and directed. The transformer shall comprises following:
(i) 03 Nos porcelain bushings with copper rod on HV side.
(ii) 01 cable end box on LV side consisting of 04 Nos bushing.
(iii) Oil conservator tank with filter type drain plug and oil level guage.
(iv) Dehydrating breather with first fill of silica gel
(v) explosive vent ,oil level guage,oil drain filter valve,lifting hucks,oil filling hole with cap/plug with connection plate, Air release valve plug complete.
(vi) 01 Nos 100mm dia, dial type thermometer,vapour pressure type having range 0-120 degree with metal guard.
(vii) 02 Nos earthing terminals on tank cover to facilitate fixing of 50x6mm GI earth strip for earthing of body including rating plate and terminal marking plate. All date shall me marked on Rating plate.
(viii) First fill of unused and new transformer oil,IS-335 Marked filtered and tested upto 60KV die electric strngth at 2.5 mm air gap between testing electrode.
Note:- (a) Pre commissioning test shall be carried out by SEI from HQ CE SWC or rep of accepting officer. All arrangement for the same shall be made by contractor and cost of which included in quoted rate.
(b) Cost for suitable size of transformer platform shall be measured and paid separately under B/R item hereinafter | 2 | Each Job | 8,25,000 ₹16.5 L | 8,85,000 ₹17.7 L | 7,80,000 ₹15.6 L | 7,00,000 ₹14 L | 5,93,000 ₹11.9 L | 7,30,000 ₹14.6 L | 8,50,000 ₹17 L | 6,75,000 ₹13.5 L | 10,30,000 ₹20.6 L |
| 2.00 | Supply and Installation,testing and commissioning of platform mounted transformer 100 KVA, 11/0.433KV, 50 Hz, step down, outdoor type, ONAN Cooled oil immersed copper wound energy efficient transformer, complete with first filling of IS-335 ISI marked filtered & dehyrated tranformer oil and other standard fittings/acceesories and 7 position OFF load circuit tap changer (Tapping range + 7.5% in steps of 2.5% Each) with vector group Dyn-11, with provision of HV and LV cable box suitable for making connection of incomming HT cable and outgoing LT cable all as per IS 1180-2014 (Level-2) and complet with and including all required accessories for installation of transformer all as specified and directed. The transformer shall comprises following:
(i) 03 Nos porcelain bushings with copper rod on HV side.
(ii) 01 cable end box on LV side consisting of 04 Nos bushing.
(iii) Oil conservator tank with filter type drain plug and oil level guage.
(iv) Dehydrating breather with first fill of silica gel
(v) explosive vent ,oil level guage,oil drain filter valve,lifting hucks,oil filling hole with cap/plug with connection plate, Air release valve plug complete.
(vi) 01 Nos 100mm dia, dial type thermometer,vapour pressure type having range 0-120 degree with metal guard.
(vii) 02 Nos earthing terminals on tank cover to facilitate fixing of 50x6mm GI earth strip for earthing of body including rating plate and terminal marking plate. All date shall me marked on Rating plate.
(viii) First fill of unused and new transformer oil,IS-335 Marked filtered and tested upto 60KV die electric strngth at 2.5 mm air gap between testing electrode.
Note:- (a) Pre commissioning test shall be carried out by SEI from HQ CE SWC or rep of accepting officer. All arrangement for the same shall be made by contractor and cost of which included in quoted rate.
(b) Cost for suitable size of transformer platform shall be measured and paid separately under B/R item hereinafter. | 2 | Each Job | 6,25,000 ₹12.5 L | 6,85,000 ₹13.7 L | 5,70,000 ₹11.4 L | 9,99,999 ₹20.0 L | 4,93,000 ₹9.9 L | 5,25,000 ₹10.5 L | 7,33,000 ₹14.7 L | 5,50,000 ₹11 L | 7,00,000 ₹14 L |
| 3.00 | Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of size 110cmx100cmx50cm, outdoor type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with convential skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories :-
Incomming :
(a) MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal release & adjustable magnetic 5 to 10.0 In - 01 No .
(b) Copper Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system.
Outgoings :
(c) MCCB 4 Pole,160 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting - 01 No
(d) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable TM Setting - 02 No
(e) Multifunctional meter Digital type showing V,A,F,PF,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1 No
(f) LED indicating Lamps R,Y,B - 01 Set | 2 | Each Job | 1,50,000 ₹3 L | 1,15,000 ₹2.3 L | 1,30,000 ₹2.6 L | 1,40,000 ₹2.8 L | 1,10,700 ₹2.2 L | 1,65,000 ₹3.3 L | 1,28,000 ₹2.6 L | 1,38,000 ₹2.8 L | 2,50,000 ₹5 L |
| 4.00 | Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size100cmx100cmx50cm, outdoor type (double door both side open-able including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with convential skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories :-
Incomming :
(a) MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal release & adjustable magnetic 5 to 10.0 In - 01 No .
(b) Copper Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system.
Outgoings :
(c) MCCB 4 Pole,160 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting - 01 No
(d) MCCB 4 Pole 63 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable TM Setting - 02 No
(e) Multifunctional meter Digital type showing V,A,F,PF,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No..
(f) LED Indicating Lamps R,Y,B - 01 Set | 2 | Each Job | 1,35,000 ₹2.7 L | 1,05,000 ₹2.1 L | 1,27,000 ₹2.5 L | 1,20,000 ₹2.4 L | 1,04,000 ₹2.1 L | 1,65,000 ₹3.3 L | 1,28,000 ₹2.6 L | 1,31,000 ₹2.6 L | 2,25,000 ₹4.5 L |
| 5.00 | Supply and Laying XLPE insulated HT cable of size 95 Sqmm 3 Core, 11000 volt grade heavy duty with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip or wire and over all PVC sheathed stranded conductor conforming to IS-7098 (Part-II) with latest amendments laid in trenches/ fixed to wall/ pole/roof/laid in floor including suitable size of thimbling complete all as specified and directed by Engineer-in-Charge. | 2,210 | RM | 990 ₹21.9 L | 1,040 ₹23.0 L | 1,070 ₹23.6 L | 999 ₹22.1 L | 1,350 ₹29.8 L | 1,050 ₹23.2 L | 1,039 ₹23.0 L | 1,250 ₹27.6 L | 940 ₹20.8 L |
| 6.00 | Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40 mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion. | 24 | Each Set | 4,000 ₹96,000 | 3,000 ₹72,000 | 4,500 ₹1.1 L | 4,500 ₹1.1 L | 5,000 ₹1.2 L | 5,000 ₹1.2 L | 4,500 ₹1.1 L | 3,800 ₹91,200 | 6,000 ₹1.4 L |
| 7.00 | Material and Labour for Cold shrinkable end termination joint outdoor type suitable for HT XLPE cable of size 95 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge | 18 | Each | 14,500 ₹2.6 L | 4,500 ₹81,000 | 3,600 ₹64,800 | 2,500 ₹45,000 | 13,000 ₹2.3 L | 10,000 ₹1.8 L | 7,600 ₹1.4 L | 12,500 ₹2.3 L | 12,000 ₹2.2 L |
| 8.00 | Supplying laying, jointing, testing and commissioning of LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 185 Sqmm 3.5 Core all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection shall be measured and paid for separtely) complete all as specified and directed. | 120 | RM | 1,300 ₹1.6 L | 600 ₹72,000 | 1,100 ₹1.3 L | 1,200 ₹1.4 L | 1,299 ₹1.6 L | 1,300 ₹1.6 L | 1,192 ₹1.4 L | 1,250 ₹1.5 L | 1,170 ₹1.4 L |
| 9.00 | Supply and laying GI tubing, light grade, 80 mm bore complete with all fittings for cable protection laid in trenches/fixed to poles/along wall/under road/across the drain complete all as specified and as directed by Engineer-in-Charge. | 42 | RM | 700 ₹29,400 | 650 ₹27,300 | 500 ₹21,000 | 600 ₹25,200 | 600 ₹25,200 | 900 ₹37,800 | 445 ₹18,690 | 500 ₹21,000 | 600 ₹25,200 |
| 10.00 | Material and labour for making the hole under road and hard standing suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface complete all as specified and directed by Engineer-in-Charge. | 21 | RM | 1,000 ₹21,000 | 400 ₹8,400 | 500 ₹10,500 | 900 ₹18,900 | 550 ₹11,550 | 300 ₹6,300 | 300 ₹6,300 | 400 ₹8,400 | 400 ₹8,400 |
Updated dates
Tender Value
₹75.0 L
EMD Value
₹1.4 L
Closing Date
17 Nov 2025, 6:00 pmClosed
COMMANDER WORKS ENGINEER
HQ CWE HISAR, HISAR MIL STN HISAR
CONVERSION OF OH HT LINE TO UG HT LINE AND SPL REPAIR REPLACEMENT OF TRANSFORMER AND CONNECTED ITEMS UNDER GE WEST HISAR
2025_MES_731241_1
CWE/HSR-47 OF 2025-26
Open Tender
Civil Works
180 days
HISAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE WEST HISAR
₹1.4 L
22 Dec 2025
16 Sept 2025
19 Nov 2025
16 Sept 2025
17 Nov 2025
3 Nov 2025
17 Sept 2025 - 24 Sept 2025
Amount
Supply and Laying XLPE insulated HT cable of size 95 Sqmm 3 Core, 11000 volt grade heavy duty with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip or wire and over all PVC sheathed stranded conductor conforming to IS-7098 (Part-II) with latest amendments laid in trenches/ fixed to wall/ pole/roof/laid in floor including suitable size of thimbling complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40 mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
Material and Labour for Cold shrinkable end termination joint outdoor type suitable for HT XLPE cable of size 95 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as specified and directed by Engineer-in-Charge
Supplying laying, jointing, testing and commissioning of LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 185 Sqmm 3.5 Core all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection shall be measured and paid for separtely) complete all as specified and directed.
Supply and laying GI tubing, light grade, 80 mm bore complete with all fittings for cable protection laid in trenches/fixed to poles/along wall/under road/across the drain complete all as specified and as directed by Engineer-in-Charge.
Material and labour for making the hole under road and hard standing suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavation in trenchessoft/loose soil n.exc 1.5 mtr wide and not foundation exc 1.5 mtr in depth for laying cable, shafts, wells, cesspits, manholes, pier holes etc n.ex 10 Sqmm on plan and n.ex 1.5 mt in depth and getting out all as directed by Engr-in-Charge.
Returning, filling in, any type of soil and spreading in layers not exceeding 25 cm thick
M & L for sand cushioning 230mm thickness (one layer of 80mm thickness before nlaying of cable and other layer of 150mm thickness punned down to 180mm after laying of cable in trenches for protection of cable all as specified and directed (only punned thickness shall be measured for payment)
Material & labour for bricks covering to under ground electric cable using sub class 'B' bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed.
Removal of surplus soil ( any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed
Dismantling of old transformer after Isolating 11 KV HT supply from the substation, 2pole /4 pole structure and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from Plinth , 2pole /4 pole structure and Shifting the transformer from site to the AGE E/M store yard at EBS Hisar
M & L for brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Material & labour for PCC 1:3:6 type C-1 using 40 mm graded stone aggregate . in mass concrete and filling complete for plinth of Transformer all as specified & directed by Enge-in- Charge
Material and labour for plastering 20 mm thick (in two coats of 15 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
Supply only galvanized steel chain link fence fabric of mesh size 100 mm X 100 mm, made out of 3.15 nominal dia mesh wire, heavy zinc coating type conforming to IS 2721: 2003 complete all as specified and as directed.
Fixing only galvanized steel chain link fence fencing including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc. including provn of binding wire complete all as specified and as directed.
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed.
Dismantling and taking down existing ACSR conductor from HT pole after unbinding from insulators from pole complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down existing GI Earth wire from HT pole after unbinding from insulators from pole complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down existing Pin type insulator and nut bolt from poles complete all as speicified and directed by Engineer-in-Charge.
Dismantling of old vintage PCC pole of any size including foundation and removing the same from site complete all as directed by Engineer-in-charge.
Dismantling of old rusted mild steel smithy items i.e clamps, channels, anticlimbing device, v channels etc. from HT pole and removing the same from site complete all as directed by Engineer-in-charge.
S & F in replacement of HT feeder pillar box factory made cubical type dust and vermin proof, outdoor type, both side opening of size 110 x 100 x 60cm of CRCA sheet 3 mm thick powder coated, machine pressed front/back opening in two halves with rubber gasket/bedding, locking arrangement with sliding bolt including aluminium bus bar of size 50 x 10 mm and 80 cm long 3 strips mounted on HT insulators. Each strip should be mounted minimum two insulator and nut bolt, panel shall be mounted on angle iron frame including heat shrinkable sleeve and legs made from angle iron of size 50 x 50 x 6 mm and legs 1 M long duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer and including grouted in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete incoming/outgoing cable and earth work such as excavation and removal of surplus soil etc.
Supply and laying factory made reinforced precast concrete cable cover, class HV type 1 flat size 300mm x 180mm x 40mm complete.
MAHESH KUMAR SINGLA CONTRACTOR (BID ID -3471156)
Raman Electric Trading Co (BID ID -3469980)
malik constructions (BID ID -3470614)
FOUJI ELECTRIC WORKS (BID ID -3476259)
M/s Prem Associates (BID ID -3466561)
R D Bansal (BID ID -3476395)
Vijay Electricals (BID ID -3470352)
M/s Kang Builders & Developers (BID ID -3476296)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
8160547tender.pdf
Tender Documents • 1.18 MB
BOQ_818666.xls
BOQ • 2.86 MB
Download all tender documents and submit your bid