Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹31.9 L+₹94,306.51 (3.05%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹38.9 L+₹8.0 L (25.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹40.7 L+₹9.7 L (31.4%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹47.6 L+₹16.6 L (53.7%)Rejected-Finance D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
5 Jan 2022, 6:00 pmClosed
Garrison Engineer St Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS TO LOW TENSION EXTERNAL ELECTRIFICATION, DG SET AND ALLIED WORKS AT IN MAP ACCN, PO COLONY, USMAN LINE, OFFICERS MESS, OTA UNDER GE STM
2021_MES_493376_1
8272-REPAIRS TO LOW TENSION EXTERNAL ELECTRIFICATI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
St Thomas Mount
As per Tender Documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹68,000
Yes
4 Feb 2022
8 Dec 2021
13 Jan 2022
8 Dec 2021
5 Jan 2022
22 Dec 2021
8 Dec 2021 - 15 Dec 2021
Amount
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose soil for laying cables / GI pipe, foundation of pole, stay etc complete all as specified and as directed
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed
Returning, filling in using excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed
M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick all as specified and directed
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickness i.e 18 cm shall be measured for payment purpose.
Taking out from trenches/poles/wall etc LT XLPE UG Cable /PVC Sheathed aluminum conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of LT UG Cable size of following sizes :Note: Rate including Earth Work. Jointing Kit will be measured and paid separately under relevant Item
(a) LT UG Cable 2/ 3.5/ 4 core 6 Sqmm to 3.5 core 50 Sqmm
(b) LT UG Cable 3.5 core 70 Sqmm to 3.5 core 300 Sqmm
Taking down old UNSV UG Cables and taking as schedule of credit including, Supplying, laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminum conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed of following sizes:
(a) LT UG Cable 2 core 10 sqmm .
(b) LT UG Cable 4 core 16 sqmm .
(c) LT UG Cable 4 core 25 sqmm .
(d) LT UG Cable 3.5 core 35 sqmm .
(e) LT UG Cable 3.5 core 50 sqmm .
(f) LT UG Cable 3.5 core 70 sqmm .
(g) LT UG Cable 3.5 core 95 sqmm .
(h) LT UG Cable 3.5 core 120 sqmm .
(j) LT UG Cable 3.5 core 150 sqmm .
(k) LT UG Cable 3.5 core 185 sqmm .
(l) LT UG Cable 3.5 core 240 sqmm .
(m) LT UG Cable 3.5 core 300 sqmm .
Supply and Fix Straight through joints Heat Shrink insulations and sealing system for underground cable including joint kits and labour complete for making joints suitable for LT XLPE/ PVC sheathed/ armoured heavy duty cables with aluminium conductor all as specified and as directed of following sizes:-
(a) 3.5/ 4 core 10 to 16 sqmm
(b) 3.5/ 4 core 25 to 50 sqmm
(a) 3.5/ 4 core 70 Sqmm
(b) 3.5/ 4 core 95 Sqmm
(c) 3.5/ 4 core 120 Sqmm
(d) 3.5/ 4 core 150 Sqmm
(e) 3.5/ 4 core 185 Sqmm
(f) 3.5/ 4 core 240 Sqmm
(g) 3.5/ 4 core 300 Sqmm
(h) 3.5/ 4 core 400 Sqmm
Taking down old UNSV Main switch/ Switch fuse Unit and taking as schedule of credit including Supply & Fix the following MCCBs Thermal magnetic release type directly fixing to main board/panel /walls including new alteration to panel with all necessary accessories all as specified and directed.
(a) MCCB 63A , 4 pole , 16 KA
(b) MCCB 100A , 4 pole , 16 KA
( c) MCCB 125A , 4 pole , 16 KA
(d) MCCB 160A , 4 pole , 35 KA
(e) MCCB 200A , 4 pole , 35KA
(f) MCCB 250A , 4 pole , 35 KA
Supply & Fix 3 phase 04 pole ON-LOAD with advanced Neutral type of capacity 200 Amps including taking out old unserviceable one directly fixing to main board/panel /walls including all necessary accessories all as specified and directed.
Supply & Fix 3 phase 04 pole ON-LOAD with advanced Neutral type of capacity 250 Amps including taking out old unserviceable one directly fixing to main board/panel /walls including all necessary accessories all as specified and directed.
Supply & Fix 3 phase 04 pole ON-LOAD with advanced Neutral type of capacity 320 Amps including taking out old unserviceable one directly fixing to main board/panel /walls including all necessary accessories all as specified and directed.
M&L in replacement for factory made sheet metal encloser (junction panel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 75X60X30cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 600 Amps suitable for one incoming and 5 out going feeders, mounted on insulators including disconnection of cable from the burnt bus bar and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, necessary earth work and PCC foundation for grouting of four legs all as per existing.
S&F in replacement of aluminium tube terminals (cable lugs) of size 10/16 Sqmm
S&F in replacement of aluminium tube terminals (cable lugs) of size 25 Sqmm
S&F in replacement of aluminium tube terminals (cable lugs) of size 35 Sqmm
S&F in replacement of aluminium tube terminals (cable lugs) of size 50 Sqmm
S&F in replacement of aluminium tube terminals (cable lugs) of size 70 Sqmm
S&F in replacement of aluminium tube terminals(cable lugs) of size 95 Sqmm
S&F in replacement of aluminium tube terminals (cable lugs) of size 120 Sqmm
S&F in replacement of aluminium tube terminals (cable lugs) of size 150 Sqmm
S&F in replacement of aluminium tube terminals (cable lugs) of size 185 Sqmm
S&F of tubes light grade of size 80 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed.
S&F of tubes light grade of size 50 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed.
S&F of tubes light grade of size 40 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete, including taking down old u/s GI tubing all as specified and as directed.
Supply and fixing in replacement Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20x15 cm size all as specified and directed. Note :- Instruction shall be written in three language Hindi, English and Tamil on notice board.
M&L for load balancing of Single/three phase system at LT Panel upto Distribution box of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium tube terminal of any size and capacity all as specified and as directed. Note: (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate
M&L for surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete, necessary earthwork as required all as specified and directed Note: Rate of necessary earthwork as required at site are deemed to be included in the quoted rate
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 250 Amps with breaking capacity 16 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 07 Nos (b) Multi function Meter with CT & PTs-01 No ( c) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 05 Nos (b) Multi function Meter with CT & PTs-01 No ( c) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) ON LOAD Changeover 250 A - 02Nos OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 250 Amps with breaking capacity 25 KA. - 01 No (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 01 No (c) Multi function Meter with CT & PTs-01 No ( d) Phase indication lamps - 3 Nos.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 03 Nos (b) Multi function Meter with CT & PTs-01 No ( c) Power Contactor 40 Amps (d) Digital Time Switch for Street Light Control ( e) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) ON LOAD Changeover 200A - 01No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 01 No (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 05Nos (b) Multi function Meter with CT & PTs-01 No ( c) Power Contactor 40 Amps (d) Digital Time Switch for Street Light Control ( e) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 200 Amps with breaking capacity 25 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 125 Amps with breaking capacity 16 KA. - 01 No (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 01 No ( c) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 02 Nos (d) Multi function Meter with CT & PTs-01 No (e) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 320 Amps with breaking capacity 36 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 200 Amps with breaking capacity 25 KA. - 02 Nos (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 125 Amps with breaking capacity 16 KA. - 01 No ( c) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 02 Nos (d) Multi function Meter with CT & PTs-01 No (e) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 125 Amps with breaking capacity 16 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 03 Nos (b) Multi function Meter with CT & PTs-01 No ( c) Phase indication lamps - 3 Nos.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 250 Amps with breaking capacity 25 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 160 Amps with breaking capacity 16 KA. - 01No (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 125 Amps with breaking capacity 16 KA. - 01No ( c) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 03Nos (d) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 02 Nos (e) Multi function Meter with CT & PTs-01 No (f) Power Contactor 40 Amps (g) Digital Time Switch for Street Light Control (h) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
Supply Fabricate, install, connect, test and commission LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:-
INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 200 Amps with breaking capacity 25 KA. - 01 No OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 125 Amps with breaking capacity 16 KA. - 02Nos (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 02 Nos ( c) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 02 Nos (d) Multi function Meter with CT & PTs-01 No (e) Phase indication lamps - 3 Nos. Note: All Changeover Switch/MCCBs should be front handle operated.
M&L for preparation of old painted surfaces of LT panel/feeder pillar box of any type outdoor/indoor including removing old paint with scrubbing and applying one coat of synthetic enamel paint of shade as per existing over a coat of red oxide primer, with electrically operated spray machine complete all as specified and directed.
Material and labour for earth pit chamber of size 0.6mx 0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chamber of size 200 mm depth, 300mm length and 300mm width, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to steel strip 25X4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No.3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B-1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
Finding and rectification of electrical fault by checking of external/internal elect supply feeder, street light feeder, OH conductors /under ground cables using elect tools, equipment and safety devices after arranging elect shut down of feeders from sub station to remove elect faults like tightening of loose connection, removing of any electric short,meggring of cable,excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightning of cable lugs etc all as required at site and as directed Note:- (i) The Electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and saftey devices. (ii) Any major materials used for rectification of faults like Cables, MCB/MCCB/cable jointing kits/cables of any type etc will be measured and paid seperately
RADHIKAGANESH ENTERPRISES
M/S.RANGA AND CO
EVEREST ENGINEERING WORKS
S.M.ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .