Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | ₹47.0 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹47.6 L+₹68,800 (1.47%)Rejected-Finance PLOT NO L 7 KRISHNA KRIPA VILLAGE SIROLI JAGATPURA JAIPUR 303905 RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 303905 | ₹47.6 L+₹68,800 (1.47%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹47.9 L+₹96,800 (2.06%)Rejected-Finance | ₹47.9 L+₹96,800 (2.06%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹49.2 L+₹2.2 L (4.69%)Rejected-Finance | ₹49.2 L+₹2.2 L (4.69%) | L4 | Rejected-Finance Other than lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected due to not meeting the eligibility criteria |
| Sl No | Description | Qty | Unit | PD GUPTA AND COMPANY L1 | M/S MAKHIJA TRADERS L4 | K P BUILDERS L2 | GUPTA AND ENGINEERS L3 |
|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE 'A' PART-XI (MISC ITEMS) : | |||||||
| 2.00 | LLDPE Septic tanks with UPFLOW FILTER INCL MEDIA , 05 Users, designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete for 05 users complete all as specified and directed | 4 | EACH | 48,000 ₹1,92,000 Lowest | 50,000 ₹2,00,000 | 85,000 ₹3,40,000 | 85,000 ₹3,40,000 |
| 3.00 | Soakage wells exc, in ordinary soil, foundation in PCC (1:3:6) , walls of honey combed and solid RCC slab in M-25 concrete, including intercepting chamber, screen chamber, Brick work in CM 1:4, RCC cover slab in M-25/RR masonary /filling with bricks bats,complete of size 1.80m dia x 3.0m deep complete all as specified and directed
Drg No. - CEJZ/2004/TD/S-35, Sheet - 1/1 | 4 | EACH | 48,000 ₹1,92,000 Lowest | 50,000 ₹2,00,000 | 75,000 ₹3,00,000 | 75,000 ₹3,00,000 |
| 4.00 | Drilling hole in hard standing / road for laying of pipe for protection of cable etc by adopting method of horizontal manual drilling (trenchless technology) without disturbing the top surface or cutting and making good the disturbed surface to the existing surface complete all as specified and directed | 12 | RM | 450 ₹5,400 Lowest | 550 ₹6,600 | 450 ₹5,400 Lowest | 450 ₹5,400 Lowest |
| 5.00 | S&F for fully automatic star delta starter in existing panel for hooter motors of Cap-3HP of relay range 4-6.5 Amps complete all as specified and directed | 4 | EACH | 9,000 ₹36,000 Lowest | 10,000 ₹40,000 | 18,000 ₹72,000 | 18,000 ₹72,000 |
| 6.00 | Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with 4 No. busbar of capacity 63 Amp and MCB 6 Amp-1 No.with flat iron clamps of size 30 x 6mm, nuts and bolts complete all as specified and directed | 4 | EACH | 900 ₹3,600 Lowest | 1,000 ₹4,000 | 12,000 ₹48,000 | 12,000 ₹48,000 |
| 7.00 | M&L for LT cable of control cable of 1100V , 4 sqmm 3 core copper conductor PVC insulated PVC sheathed, round wire strip armoured complete all as specified and directed | 80 | RM | 50 ₹4,000 Lowest | 60 ₹4,800 | 680 ₹54,400 | 680 ₹54,400 |
| 8.00 | Supply, install, test and commissioning factory made 3 phase 400/440 volt 3 HP audiable range up to 5 KM of 2800 RPM of model HDT 500 complete all as specified and directed | 4 | EACH | 1,25,000 ₹5,00,000 | 1,35,000 ₹5,40,000 | 75,000 ₹3,00,000 Lowest | 75,000 ₹3,00,000 Lowest |
| 9.00 | Lump sum price worked out by the contractor for Building/Structure Works as listed in Sch 'A' Part-I. | 1 | EACH | 30,00,000 ₹30,00,000 Lowest | 31,00,000 ₹31,00,000 | 30,00,000 ₹30,00,000 Lowest | 30,00,000 ₹30,00,000 Lowest |
| 10.00 | Lump sum price worked out by the contractor for Site Clearance, Excavation & Earth Works as listed in Sch 'A' Part-II. | 1 | EACH | 99,000 ₹99,000 | 1,10,000 ₹1,10,000 | 85,000 ₹85,000 Lowest | 85,000 ₹85,000 Lowest |
Tender Value
₹43.0 L
EMD Value
₹86,200
Closing Date
9 Dec 2025, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender documents
2025_MES_724263_3
CWE/MTR/BPR/ of 2025-26
Open Tender
Civil Works
Lump-sum
270 days
GE Bharatpur
As per NIT documents
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹86,200
Yes
21 Jan 2026
25 Nov 2025
16 Dec 2025
25 Nov 2025
9 Dec 2025
2 Dec 2025
Amount
SCHEDULE 'A' PART-XI (MISC ITEMS) :
LLDPE Septic tanks with UPFLOW FILTER INCL MEDIA , 05 Users, designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete for 05 users complete all as specified and directed
Soakage wells exc, in ordinary soil, foundation in PCC (1:3:6) , walls of honey combed and solid RCC slab in M-25 concrete, including intercepting chamber, screen chamber, Brick work in CM 1:4, RCC cover slab in M-25/RR masonary /filling with bricks bats,complete of size 1.80m dia x 3.0m deep complete all as specified and directed Drg No. - CEJZ/2004/TD/S-35, Sheet - 1/1
Drilling hole in hard standing / road for laying of pipe for protection of cable etc by adopting method of horizontal manual drilling (trenchless technology) without disturbing the top surface or cutting and making good the disturbed surface to the existing surface complete all as specified and directed
S&F for fully automatic star delta starter in existing panel for hooter motors of Cap-3HP of relay range 4-6.5 Amps complete all as specified and directed
Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with 4 No. busbar of capacity 63 Amp and MCB 6 Amp-1 No.with flat iron clamps of size 30 x 6mm, nuts and bolts complete all as specified and directed
M&L for LT cable of control cable of 1100V , 4 sqmm 3 core copper conductor PVC insulated PVC sheathed, round wire strip armoured complete all as specified and directed
Supply, install, test and commissioning factory made 3 phase 400/440 volt 3 HP audiable range up to 5 KM of 2800 RPM of model HDT 500 complete all as specified and directed
Lump sum price worked out by the contractor for Building/Structure Works as listed in Sch 'A' Part-I.
Lump sum price worked out by the contractor for Site Clearance, Excavation & Earth Works as listed in Sch 'A' Part-II.
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch 'A' Part-III.
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch 'A' Part-IV.
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch 'A' Part-V.
Lump sum price worked out by the contractor for External Electric Supply as listed in Sch 'A' Part-VI.
Lump sum price worked out by the contractor for Road, Path & Culvert as listed in Sch 'A' Part-VII.
Lump sum price worked out by the contractor for Area Drainage as listed in Sch 'A' Part-VIII.
K P BUILDERS (BID ID -3492873)
GUPTA AND ENGINEERS (BID ID -3499020)
M/S MAKHIJA TRADERS (BID ID -3499318)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
Tender.pdf
Tender Documents • 1.68 MB
BOQ_830325.xls
BOQ • 0.70 MB
Drgs_compressed.pdf
Additional Documents • 2.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .