Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹46.0 L+₹2.3 L (5.16%)Rejected-Finance 116 RUNWAL DIAMOND OPP PALACE ORCHARD N I B M UNDRI ROAD MOHAMADWADI PUNE 411 060 | PUNE | PUNE | MAHARASHTRA | 411060 | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹50.1 L+₹6.4 L (14.6%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹50.3 L+₹6.6 L (15.1%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹50.8 L+₹7.1 L (16.2%)Rejected-Finance | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
12 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
RECTIFICATION OF DEFECTS THROUGH RISK AND COST IN MD ACCN CONSTRUCTED UNDER MAP PHASE I UNDER GE CME KIRKEE
2020_MES_390185_1
CA No CWE/ KKE/ TOKEN-46 OF 2020- 21
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
As per NIT
5 documents required · 5 mandatory
₹1,000
Yes
GE CME KIRKEE
₹1.2 L
Yes
24 Dec 2020
27 Oct 2020
14 Dec 2020
27 Oct 2020
12 Dec 2020
7 Dec 2020
28 Oct 2020 - 9 Nov 2020
60 days
Amount
Taking down/removing existing water proofing treatment (Tarfelt/membrane) and cleaning the surface of slab with wire brushes, removing dust, foreign material including flashing and junctions of wall watering, removal of debris upto 100 mtr distance and depositing where directed complete all as specified and directed by Engineer-in-Charge.
Taking down existing cement plaster/screed on roof surface including raking out joints, hacking for key, scrubbing down with water, cleaning the surface of slab and removal of debris upto 100 mtr distance and depositing where directed complete all as specified and directed by Engineer-in-Char
M & L for 10 mm thick cement mortar (1:3) screed bed finished and smooth on roof top surfaces mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately.
M & L for cleaning the newly plastered/screed bed surfaces thoroughly with wire brushes and providing water proofing treatment all as given here in after :- Note :-This item continued at Sl no 4.01 to 4.04
(a) M & L for oil based bituminous primer conforming to IS 3384-1986 over cement plaster @ 0.70 Kg/Sqm manufactured by same agency as that of APP over cement plaster on roof surfaces prior laying APP membrane.
(b) M & L for 3mm thick and weighing not less than 3.60kg/sqm Atactic Polypropylene Polymer (APP) modified bitumen based prefabricated five layer water proofing membrane reinforced with non woven polyster fabric, black finished over compatible primer at 0.4Lit/Sqm of with density of 0.87 to 0.89 Kg/Litre at 25 degree celsius and viscosity 70-160 cps or cold sticker on the prepared dry roof surfaces, with torch application of membrane with 10cm overlap bothways after necessary preparation of surface as per manufacturers instructions complete and all as specified and directed.
(c) M & L for applying over the membrane finishing with two coats of solar reflective bituminous aluminium paint @ 0.1 lit/Sqm for each coat as prescribed by manufactures and all as directed by Engineer-in-Charge.
NOTE : (i) The contractor will be permitted to use materials procured from any one of the manufacturer mentioned in list of approved makes However, the materials for the entire work shall be of from one manufacturer only. (ii) Work shall be executed by authorized applicator of the manufacturer.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed .
M & L for PCC (1:2:4) type B0 using (12.5 mm graded stone aggregate) mixed with water proofing compound as per manufacturer's instructions as in concrete levelling course laid to required slope of 1:50 including finishing the concrete surface fair and even without using extra cement all as specified and directed. Note:- (i) Water proofing compound shall be measured and paid separately as supply only under relevant item of this schedule.
Supply only integral water proofing compound.
Disconnecting existing tanks, exc 250 & n.exc 500 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required and reconnecting, re fixing in position after completion of water proofing treatment to the roof complete all as specified and directed.
Dismantling of floor hearth or wall tiling incl cement mortar bedding (but not backing) and removing serviceable tiles in stores and rubbish off the premises complete all as specified and directed .
M & L for sunken floor treatment as per following details :- Note :-This item continued at Sl no 11.01 to 11.08
(a) Demolition of existing treatment of any description and thickness and removal of rubbish outside MD land.
(b) Clean the sunken portion of toilet / Bath / WC / Kitchen thoroughly to remove laitance, dirt dust, etc.
(c) Form angle fillet of size 40mm x 40mm along the junction of wall and floor using polymer modified mortar "Dr Fixit" Pidicrete URP" or other equivalent product of M/S STP Limited/ M/S Fosroc chemicals/ M/S Thermax limited as approved by GE.
(d) Sanitary pipes entering through walls and floor shall be sealed with "Dr Fixit Bathseal Tape" and the gaps shall be grouted with non shrink cementitous grout "Dr Fixit Bathseal Grout" or other equivalent product of M/S STP Limited/ M/S Fosroc chemicals/ M/S Thermax limited as approved by GE. Nahani Traps, etc to be fitted securely and the gaps around it shall be grouted in the same manner.
(e) Apply one coat of a Bitumen modified polymer coating "Dr Fixit Bathseal Plus" or other equivalent product of M/S STP Limited/ M/S Fosroc chemicals/ M/S Thermax limited as approved by GE. on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.
(f) In the remaining area, in dry substrate condition, apply first coat of the same coating with brush and further apply second coat when first coat is dried. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing coating "Dr Fixit Pidifin 2K" or other equivalent product of M/S STP Limited/ M/S Fosroc chemicals/ M/S Thermax limited as approved by GE. shall be further applied right upto 2.10 m to water proof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely complete all as per manufacturers instruction and direction.
(g) After 2 to 3 days, sunken portion shall be overlaid with a 50 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) mixed with water proofing compound as per manufacturer's instructions laid to be slope 1:60 towards outer face of wall. Provide 40mm outer dia UPVC pipe at the lowest point with 300mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete (1:5:10) type E2 (using 40 mm graded stone aggregate) complete all as per manufacturers instruction and direction and directed by Engineer in charge.
Note:- (i) UPVC pipe 40mm dia shall be measured and paid separately as supply only under relevant item of this schedule.
Supply only UPVC pipe 40mm bore as in water spouts all as directed.
M & L for Non skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M & L Glazed coloured ceramic tiles of size (300mm x 200mm) x 6 to 7 mm thick as in vertical surfaces such as skirting , dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and inlcuding 10mm thick backing coat in CM (1:4) etc complete all as specified and as directed.
S & F in repairs for vitreous China wash down water closet, pedestal pattern, white (including fixing blots, connecting to flushing cistern and flush pipe) including provision of flushing pipe, syphonage pipe etc. complete all as specified and as directed.
S & F plastic water closet seat cover, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S & F in repair 10 ltr capacity PVC valveless , syphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including bracket and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed.
S & F in repair brass CP health faucet for EWC, 15 mm bore, including one metre length PVC barbed flexible pipe with steel casing and hook fixed to wall etc complete as specified and directed by Engineer-in-charge.
S & F in repair 15 mm bore two way angle cock, with capstan head, brass chromium plated fancy type, screwed down high pressure, with wall flange, long shanks and flynuts, screwed for iron pipe complete all as specified and directed.
United Sales Corporation
L.K.R.TIWARI CONSTRUCTION
Mukund Engineers and Contractors
Om Construction
Anand Trading Co
UNIQUE ENGINEERS
GRACE CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .