Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC NO 9 DR SEVALIYE SHIVAJI GANESAN NAGAR 3RD STREET DINDIGUL 624 001 | DINDIGUL | DINDIGUL | TAMIL NADU | 624001 | ₹1.2 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹1.3 Cr+₹7.0 L (5.64%)Rejected-Finance 10 324 17 BALAJI NAGAR ARUVANKADU COONOOR THE NILGIRIS TAMIL NADU 643202 | COONOOR | THE NILGIRIS | TAMIL NADU | 643202 | ₹1.3 Cr+₹7.0 L (5.64%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹1.3 Cr+₹7.9 L (6.33%)Rejected-Finance 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | ₹1.3 Cr+₹7.9 L (6.33%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹1.3 Cr+₹9.1 L (7.26%)Rejected-Finance | ₹1.3 Cr+₹9.1 L (7.26%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹1.4 Cr+₹10.8 L (8.62%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | ₹1.4 Cr+₹10.8 L (8.62%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
9 Dec 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVN OF CERTAIN SANCTIONED INCLUDING MINOR AND REVENUE WORKS AT AFS SULUR
2020_MES_394872_1
8379/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹2.1 L
Yes
31 Dec 2020
12 Nov 2020
10 Dec 2020
12 Nov 2020
9 Dec 2020
3 Dec 2020
12 Nov 2020 - 2 Dec 2020
Amount
SCHEDULE A BOQ
Excavation in trenches any type of soil not exeding 1.5 m deep and not exeeding 1.5m in depth for foundation etc.
M&L Cement concrete in foundation 1:4:8 type D-2, 40 mm graded stone aggregate as in foundation, sub base to flooring, foundation of poles all as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Fly ash Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in C:M 1:6 complete all as specified and directed.
40mm thick damp proof course 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate using WPC (Supply only water proofing compound to be measured and paid separately )
Returning, filling in including spreading leveling, watering and wall ramming in layers not exceeding 25cm in soft /loose soil complete all as specified and directed.
Removal of surplus soil not exceeding 100 metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed.
Supply only integral water proofing compound
Spreading and leveling in layers not exceeding 25 cm thick each layer including watering and well ramming complete all as specified and directed.
Providing 75mm thick plain cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in sub base to tiles complete including demolition of concrete and removing rubish material to out side MD land all as specified and directed.
Providing 25mm thick plain cement concrete 1:2:4 type B1 (using 12.5 mm graded crushed stone aggregate) as in sub base to floor/ receive the tile complete and removing rubish material to out side MD land all as specified and directed .
M&L form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work: not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concrete complete all as specified and directed.
M&L form work to soffits of beams, cantilevers, lintels over 1.5m span and similar work rough finished surfaces of concrete complete all as specified and directed.
M&L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
Rendering 15 mm thick in two layers on brick or stone or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: (a) Water proofing compound shall be measured and paid seperately. (b) The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
RCC 1:1½:3 Type B-1 using 20mm graded stone agg. as in beam and lintels etc.
Rendering 10 mm thick on ceiling surfaces, in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
Deformed TMT steel bar of grade Fe-500, 10mm dia aand over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
Rendering 10 mm thick on brick or stone or concrete surfaces, in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
RCC 1:1½:3 Type B-1 using 20mm graded stone agg. as in roof slab.
Hardcore 150mm thick spread thickness with stone/broken boulders or quarried stone of gauge exc 63mm but n exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface complete all as specified and as specified and as directed.
Deformed TMTsteel bar of grade Fe-500, 5 mm dia to 10 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips in stirrups , spacers and binders etc complete all as specified and directed.
M&L applying three coats of white washing on ceiling including preparation of surfaces complete all as specified and directed.
M&L applying three coats of white washing on walls including preparation of surfaces complete all as specified and directed.
M&L two coats of cement base paint over one coat of cement primer on walls including preparation of surfaces complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S&F 150 mm long Aluminium barrel tower bolts powder coated any colour complete all as specified.
S&F 125 mm long Aluminium handles powder coated any colour oval type complete all as specified.
S&F mild steel powder coated but hinges medium weight cold rolled size 100mm.
M&L Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in concrete bed to drain pipe 150mm including packing under and hunching against the sides of pipe after they are laid & tested.
Cutting into existing manholes for connecting new drain pipe for 150 mm bore pipes complete incl making good benching etc
M&L for salt glazed stone ware gully trap, square or round moulded type and size of trap 150x150mm including removal of existing trap and fixing in the same position with PCC 1:2:4 complete all as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls/floor including distance pieces and stack clamps as in rain water pipes complete all as specified
S&F 110mm bore PVC(SWR) bends/shoe any radius fixed to walls including distance pieces and stack clamps complete all as specified
Supplying and fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified.
S&F in repair PVC Dual flush ceramic colour , low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements Cat Part No 21029 of - hindware or equivalent all as specified and as directed.
S&F PVC connection 600mm long of dia 15mm complete all as specified.
Pillar taps 15mm bore CP with capstan head screwed down high pressure screwed for iron pipe Cat Part No CQT -23021KN of Jaquar or equivalent to /Parryware/Hindware/ Cera complete as directed by Engr-in-charge.
25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including taking down existing pipe of any description complete to walls, ceilings or in floors etc. all as specified and directed. Make :- SFMC, Prince, KPT
Note for item No 41 :- The unit rate shall be include for taking down existing GI pipe and connections and all fittings as directed.
The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
Wall thickness of pipes shall be all as per IS : 15801
Stop cock, valves high pressure screwed both ends iron pipe or for unioins 15mm dia, CAT Part No G3007A1 of Parryware or equivalent to Hindware/Cera complete as directed by Engr-in-charge.
S&F of wash basin vitrous china (flat back and angle back Type) size 580x450mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe, fixed in repair all as specified.
PVC connections 15mm size with PTMT nuts of length 450mm
32mm dia waste fittings, brass chromium plated for basins with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed
32mm LDPE pipes of pressure rating 6 kgf/Sqcm fixed to walls ceilings or in floors etc
S&F rotational moulded PVC water storage tank 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position including fixing accessories complete all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:4 including Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including rubbing and polishing complete all as specified and directed by Engr-in-Charge. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
Framed work such as grills , grating ,etc with ends of bars shouldered and or revated for forged in to spike, framed guard bars barred iron doors, ladders, balusters, walk ways raling framed work for water tanks similar work confirming to Fe -290 Gde E-165
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing to outside MD land.
100mm thick, plain cement concrete (1:2:4), type B-1 (using 20 mm graded mechanically crushed stone aggregates), as in hardstanding including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, including demolition of existing concrete and removal of debris out of MD land complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M&L Joint free Non Skid Ceramic Tiles 7 to 8 mm thick [Square or Rectangular] Coloured, area of each tile exceeding 0.09 Sq.m and not exceeding 0.18 Sq.m, as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer,15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Glazed ceramic coloured tiles 350 x 250 x 7/8mm, 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado including 10mm thick 1:4 backing coat complete all as specified and as directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
100mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor concrete shall be laid in alternate bays not exc 3 mtr length, finished even and fair including roughening surfaces of old concrete floor or concrete surfaces by hacking sweeping clean and washing down with water to remove dust to outside MD land all as specified and as direted complete.
Surface excavation n exc 30 cm deep and averaging 15cm deep in hard/ dense soil and getting out, including disposal of rubis material, spreading and levelling in layers 25cm thick including watering as required all as directed.
Preparation of newly plaster surfaces of walls and two coats of dry distamper over one coat of chalk whiting complete all as specified and directed.
S&F 100 mm cast iron soil /waste/vent pipes, in any length with or without ears laid in trenches, floors or in walls incl stack clamps wherever necessary complete all as specified and directed .
S&F 50 mm cast iron soil /waste/vent pipes, in any length with or without ears laid in trenches, floors or in walls incl stack clamps wherever necessary complete all as specified and directed .
M&L 100mm CI Bends with or with out door (any radius) diminishing pieces/"T" or tapers including jointing with cement joints complete all as specified.
M & L for cast iron Brach piece single (equal or unequal) with oval access door for 100 mm pipe.
Aluminium powder coated adjustable louvers, frame of size 63.5x38.1x1.53mm weighing 0.942 Kg/m, (Section No 20047) with 4mm thick pinned glass with necessary rubber beading etc.complete all as specified and directed.
Anodised aluminium powder coated ventilator, fixed type without sash bar, aluminium section weighing exc 0.55 Kg/m, including provision of louvered strip and 4mm thick figured glass as in louvered strip with mosquito proof wire cloth of stainless strip with 0.45mm dia and 1.14mm aperature fixed with aluminium flat and screws complete all as specified and directed.
M & L for 75mm bore dia PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed by the Engineer-in-Charge
M&L PVC (SWR) gully trap 125/110 mm, setting abd jointing with solvent cement
20 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including taking down existing pipe of any description complete to walls, ceilings or in floors etc. all as specified and directed. Make :- SFMC, Prince, KPT
Note for item No 70 :- The unit rate shall be include for taking down existing GI pipe and connections and all fittings as directed.
The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
Wall thickness of pipes shall be all as per IS : 15801
CP Concealed stop cock, Regular body with adjustable wall flange screwed down screwed for iron pipe in repairs 15mm bore (Make:CAT Part No--CQT-23083 of Jaquar or or equivalent in as per list of makes complete all as specified and as directed by Engineer-in-Charge
S&F Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15mm bore of iron pipe or for union and fixed all as specified.
S&F Vitreous china urinals, half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified and as directed.
Pre painted Coloured Galvalume roofing system corrugated sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws, complete including dismantling any type of sheet all as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of any type of sheet as specified
Note for Pre-painted coloured Galvalume roofing :-
(i) The unit rate is deemed to be included for dismantling to Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed
(ii) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(iii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iv) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(v) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
600x450 mm bevelled edge mirror fixed with 04 Nos Stainless steel studs complete all as specified and as directed.
Cutting chases, pinning in making good to facings where required and pointed in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and concealed water tubing etc and making good, cutting not exc 10 cm girth complete all as specified and as directed.
Welding in repairs, exc 2,5 cm but n exc 5 cm in length with thickness of metal to be welded n exc 6 mm.
Demolition to Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed by Engr-in-Charge
S&F Wind operated Turbo Ventilators of size 24 inches dia with FRB base plate material of construction for ventilator is high grade Industrial Aluminium of thickness not less than 0.5mm. Material of construction of hardware is stainless steel -304. Bearing shall be steel in completely enclosed and dustproof integrated housing and aligned with each other, it shall have capability to rotate at nearly zero wind speed. Turbo ventilator shall have UV stabilized powder coated and capable of static balancing shall have high exhaust capacity and there shall not be any exhaust problem due to air block draft. Fixing arrangement shall have high quality rubberised hardware to prevent rain ingren. All Turbo Ventilator to be installed by manufacturer's auth person only. Contractor shall give no leakage guaranty for period of three years from the date of installation of Turbo Ventilator all as specified and as directed. Make : M/S Turbo Ventilators, M/S SVS Wind Driven Turbo Ventilators, M/s Arven Turbo Ventilators.
S&F for grills for air circulation for turbo ventilator made with powder coated aluminium frames of size 600x600mm fixed in false ceiling grid thickness not less than 2mm complete all as specified and directed by the Engineer-in-Charge
S&F polycarbonate transperant sheet similaar to the profile of galvalume sheet 2mm thickness with two corugations side lap fixed with self tapping screws/J hooks 8mm dia in roof, wall etc complete including taking down all as specified and as directed.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confoeming to Fe-290 Gde E-165, structure steel for staging of fuel tank fabrication in vehicle all as directed. Note :- Bolts/ welding and gust plate required for staging for fuel water tank is deemed to be included.
Two coats of aluminium paint over a coat of aluminium oxide primer on new steel surfaces over 10 cm girth including necessary preparation of surfaces all specified and as directed.
M&L false ceiling using GI snap grid size 60x60cm with main runner 38x24, wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board (Lake & Hill) all as per Everest regular T-2430 or equivalent (Make-Ramco/ Charminar/ Armstrong).
M&L for two coats of aluminium paint on old steel surfaces over 10 cm girth including necessary preparation of old surfaces all specified and as directed.
Preparation of old painted surfaces of steel and applying two coat of synthetic enamel paint over a coat of red oxide primer using mechanical means over 10 cm width or girth ,not other wise described complete all as specified and as directed.
Note for item No 96 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Removing debries etc to outside MD land including loading, unloading and stacking at the destination.
Taking down carefully copper/Alu point wiring (light, fan. socket or power) complete including fixtures and fitings such as switches, ceiling roses, pendents, regulators, sockets, light fitting etc and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separetely) and making good distrubed surfaces of walls, floors etc.
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 107 here in before but for One 3 pin socket out 5 amp on the same board
(c). All as per item No. 107 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 107 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
S&F modular switch 1 way 6 Amps, 1 module Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S&F modular switch 1 way 16 Amps, 1 module Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S&F modular socket outlet multipurpose 2/3 pin 6 amps, 2 module Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S&F modular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S&F white cover plate with frame, 3 Module.
S&F white cover plate with frame, 6 Module.
S&F white cover plate with frame, 8 Module.
S&F metal flush box 3 module.
S&F metal flush box 6 module.
S&F metal flush box 8 module.
S&F electronic modular fan regulator 230 volts, step type socket type, hum free 100/ 240 watt 2 Module. Make :- Havells/ Schneider/ Crabtree
S&F ceiling rose, surface type Bakelite 65x55mm 3 terminal
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408617 or equivalent. of Schnieder, Siemens/L&T.
S&F in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size Steel conduit and all accessories fixed to wall/floors along with one run 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down unserviceable wiring complete all as specified and as directed.
Note for item No 126 :- (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor and Steel conduit shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size of brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fixing in replacement 30 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and shall have inbuilt Li-ion battery of 5200 mAH. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, should have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have >1.5 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-30-CWL-INV-RTC-R or equivalent in Philips/ Bajaj
Note for item No 128 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No 2 cm height with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient. Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work.
Supply and fixing down rod 15 mm medium grade GI tube fxing for ceiling fan with necessary cutting, screwing and fixing on angle iron all as specified and directed
Supply, installation and commissioning of advanced day lighting system of 750 mm Light Pipe with Dome + Diffuser + Flashing Plate with the following accessories of 1.2 Mtrs Length . (a) Sunlight capture system-Sunlight collector cover:- Sun light collector dome should be transparent, clear dome allows light to be collected across the sky from all direction shape should moulded, single piece, dome shaped, clear, transparent polycarbonate material and thickness not less than 3mm thick clear polycarbonate sheet. UV coating thickness for RAW material sheet should 80 microns for high UV resistance, UV block upto 99% (UV A&B), impact strength 600-800 J/M (ASTM D256), flame retardancy limiting oxygen index LOI-25 (ISO 4589 ASTMD 2863), light transmission is 83% test standard, heat resistance temperature should 45º - 150º celsius (DIN 53460) (VICAT VST/B) and thermal conductivity should be 0.21/m°c(DIN 52612) (b) Light Management system:- light deflection panels should be transparent, clear, PMMA with light deflecting angles more than light incidence angles, light transmission should be not less than 90%, panles fastening mechanical polymer push buttons system.
(c) Light transfer system:-Extension pipes:- diameter 400 mm,shape should be cylindrical, aluminium material, total reflectivity for LPR 400 mm-98%, material thickness not less than 0.4mm, protection film PE foil not UV resistant. (d) External Cladding:- If the light pipe are exposed to atmosphere external cladding is provided by galvanised iron sheet (GI) cladding enclsoing the reflective pipes inside with holding wall clamps. The pipes should be crimped circumfernctially to slip one into another and along the vertical lenght for overlap jointing of not less than 25mm. Pipes to be joined with aluminum reviting and closed with aluminium tape of 50mm width and 5 microns thickness. (e) Light diffuser:- Shape should be moulded, single piece flat/Dome shape, polycarbonate clear bright prismatic bright or pigmented opal white (soft white), thickness not less than 2mm thick material, light transmission not less than 80% with diffuser ring injection moulded ABS plastic ring -white color , double glazed and second glazing diffuser double glazed with 1.0mm thick clear polycarbonate with 90% light transmission it should be locking button provision of pipe into the diffuser ring with silicon seal.
(f) Roof Kerb:- Factory made of two piece metal roof kerb entire roof kerb made of 0.5 mm bare galvalume sheet of 240 MPA, top cover should be galvalume sheet. It holds the lightpipe and light collector, bottom kerb also gavalum sheet. It fits on to roof with complete water proof arrangement, colour coated surface finished, kerb top side pointed arrow design with breaker arrangement, water proofing method is two seal system, primary seal, butyl rubber sealant and secondary seal-dow corning 789 high coefficient expansion silicon sealant, roof crest blocking caps should be factory made bare galvalume sheet metal cap. (g) Lumen Out put:- Lumen out put should be not less than 8000 lumen. light outputs test to be done with 1.0m x1.0m x1.0m light box as per standard test procedure in lab Make:-Sky shade or its equivelant as approved by GE. Note :- The contractor shall submit product warranty certificate from manufacturer for 5 years and installation warranty certificate for 5 years against any leakage and seepage.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Bricks common burnt clay building bricks, sub-class 'B' for cable protection cover.
XLPE insulated,screened, PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 150 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 138 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
Supply only GI pipe 80 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
Supply and fixing cable route indicator made out of 15x 15x 6 mm thick MS plate welded with 8 mm x30 cm long MS rod grouted in PCC block of size 0.2x0.2x0.3(LXWXH) and writing LT cable complete all as directed
Supply and fixing in replacement LED midbay symmetric beam luminaire with housing made of die-cast aluminium of system wattage not more than 70W. The luminaire shall be with dedicated optics to provide precise light distribution of 120 degree beam angle. The luminaire shall be designed to meet its specifications on performance & lifetime at a design ambient temperature of -10°C to 45°C (Ta 45°C). A specially designed heat management system to ensure luminous efficacy >=105 lm/ W for the system and ensure lumen depreciation upto 30% over 50k burning hours. The luminaire is designed to meet IP66/ IK08 classification and is complaint with relevant immunity, safety and performance and EMI standards. The system lumens shall not be less than 7500 lumens with 6500K CCT. The CRI shall be > 70. THe luminaire shall be able operate from 140-270V AC, 50 Hz with > 0.95 PF & THD <=10%. The LEDs shall be SMD type (not COB type) and each LED shall with peanut optics. The driver shall be of potted type. Make :- Philips BY150P LED76S CW PSU HE SY120 FG GR or equivalent in Bajaj or Wipro or Havells. The luminaire and driver shall be BIS approved and shall carry "R" number.
S&F in replacement factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat No : 408587 to408595 or equivalent. of Schniede, Siemens/L&T.
S&F Triple pole nuetral MCB 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408683 or equivalent. of Schnieder (Multi -9) Siemens/L&T (Hegar).
Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size Steel conduit and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down unserviceable wiring complete all as specified and as directed
Note for item No 151 :- (a) 2 run of 4 Sqmm alongwith one run of 4 Sqmm and Steel conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed.
Note for item No 154 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately.
(c) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(d) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(e) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
GI strip 25 x 6mm thick as earthing lead fixed to wall/roofs etc all as directed.
Air termination single pointed aluminium rod of 12mm dia 300mm length fixed to GI strip 32x6mm/aluminium strip 25x3mm including nuts, bolts and washers complete all as specified and as directed.
Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc all as specified. Note : Quoted Unit Rate deem to be included drilling holes per Metre or as specified on GI/Aluminium/Copper Strip of any type and size.
Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified.
Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw complete all as per specified and as directed.
GI strip 32 x 6mm thick as earthing lead fixed to wall/roofs etc all as directed.
M&L for industrial type heavy duty wall mounted fan 450 mm sweep single phase 230 volts including fixing arrangement on wall/angle all as directed by Engineer -In-Charge complete. Make/Model : Cat No Turbo Force of Havells or equivalent in Bajaj, Crompton Greaves
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket outside. 3 phase and neutral 250 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board box and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Cutting and jointing existing UPVC pipe of 50mm dia to take new connection including all fittings, exc, earth work all as directed.
Supply and lay unplasticised PVC pipes 40mm bore dia of pipe of pressure rating 10 Kgf/cm2 laid in trench with fittings (specials) and fixtures including disconnecting and taking out old unserviceable pipe with specials complete all as specified and directed.
Supply and fix butterfly Valve, 20mm dia with gaskets, nut, washers and bolts including disconnecting and taking out unserviceable valve complete all as specified and directed.
Construction of Valve Chamber of size 600mmx600mmx600mm (internal) internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
Supply and fix heavy duty PVC hose adopter of size 20mm dia complete all as specified and directed.
Supply and fix butterfly Valve, 40mm dia with gaskets, nut, washers and bolts including disconnecting and taking out unserviceable valve complete all as specified and directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation all as directed. Make : Model HTSP 317 of safeTrode or equivalent in ISG Global/ ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( copper strip will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply, fabrication and erection of 3000 ltrs capacity elliptical shape MS container of size 1.5 mtr dia and 2 mtr length with 3.15mm thickness CRCA MS sheet with leak proof welding and supported by stiffeners of 12mm thick and entire base channel support 2 Nos by 100 x 50mm MS channel and 450mm dia projected circular opening on top of the container with door including locking arrangement. Provision of 25mm MS pipe with flange to be welded under the container bottom 0 Nos for drain and delivery of fuel with covered locking arrangement including one coat of red oxide and two coat of grey metallic enamel paint complete all as specified and as directed by Engineer-in-Charge. Note :- Base structure steel of staging/ placing of tank will be measured and paid under item No 92.
Supply and fixing digital flow meter of resetting type upto 0-3000 ltrs range suitable 25mm dia MS pipe with all accessories complete as directed.
Supply and fixing electric Monoblock pumpset 0.5 HP capacity, single phase, 230V with inlet and outlet pipe of size 25mm bore complete as specified and directed.
S&F gun metal gate valves with iron wheel head, screwed both ends for iron pipe of size 25mm bore complete as directed.
Supply and fixing of heavy duty PVC flexible pipe 25mm bore complete suitable for transmission of diesel all as directed.
M SUNDARARAJAN
S KUMARAN
Sip India Infra
KSR AND COMPANY
SARAVANARAJA CONSTRUCTIONS
KRISHNA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .