Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹12.9 L+₹2.4 L (22.4%)Rejected-AOC | L2 | Rejected-AOC L2 QUOTED | |
| 3 | L3₹14.2 L+₹3.7 L (35.5%)Rejected-AOC | L3 | Rejected-AOC L31 QUOTED | |
| 4 | L4₹15.4 L+₹4.9 L (46.4%)Rejected-AOC | L4 | Rejected-AOC L4 QUOTED | |
| 5 | Rejected-Technical | - | Rejected-Technical Non Bonafide |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
28 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Srinagar
GE (AF) Srinagar, Air Force Station-190007
CERTAIN MAINT AND MISC WORK OF B/R AND E/M AT BB CANTT AND AIR FORCE STATION, SRINAGAR UNDER AOR OF GE (AF) SRINAGAR
2020_MES_357113_1
GE(AF)-11/2020-21
Open Tender
Civil Works
Item Rate
180 days
Srinagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF Srinagar
₹30,000
Yes
7 Sept 2020
30 Jun 2020
30 Jul 2020
30 Jun 2020
28 Jul 2020
14 Jul 2020
30 Jun 2020 - 7 Jul 2020
60 days
Amount
Dismantling of plain or corrugated steel sheeting any gauge in roof coverings complete all as specified and directed by Engineer-in-Charge
M&L Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed by Engineer-in-Charge.
M & L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, eaves board, fixed with self tapping screws or welding as specified,complete all as specified and directed by Engineer-in-Charge.
Dismantling of Stone slabs and tiles of any description or thickness in floors aprons etc laid in cement mortar of any thicknes, complete all as specified and directed by Engineer-in-Charge
M & L for granite (of any type) work (table rubbed and polished) 20mm thick as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cm 1:4, complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L Screed bed or bedding layer 15mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
M & L for Rendering 10 mm thick in CM 1:4 as for backing coat of wall tiles complete all as specified and directed by Engineer-in-Charge
M & L for non skid joint free coloured ceramic tiles 7 to 8 mm thick area of each tile exc 0.11 sqm but n exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white/coloured cement to match, Complete all as specified and directed by Engineer-in-Charge.
M & L for double charged Vitrified coloured tiles 7-10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M & L for glazed ceramic (digital glossy finish) coloured tiles 450x300x7 mm thick on vertical surfaces, alongwith high lighter tiles set and jointed in neat cement slurry and pointed in white/colour cement to match over, Complete all as specified and directed by Engineer-in-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, Complete all as specified and directed by Engineer-in-Charge.
M& L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in hard standing/pavings/plinth protections, finished even and smooth without using extra cement, Complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. Complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, Complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceble wooden panneling complete all as specified and directed by the Engr-In-Charge
M & L for Wooden panelling of second class softwood 12mm thick with tongue and groove joint fixed in any position over and including wooden framework in second class softwood with plain fillets square or sectional area exc 13 Sqcm and n exc 25 Sqcm at n exc 90 cm centre to centre in both direction and including two or more coat of french polishing on all the exposed surfaces wooden panelling as in repairs including taking down existing electrical fittings and re-fixing the same, complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster any description on brick or stone wall/ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M & L Rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered surfaces and applying two coats of distemper oil emulsion including chalk whitening preparatory to distempering on surfaces of ceilings, , complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surfaces of walls and applying two coats of weather paint (Apex) paint colour and tint as ordered in any pattern over and including thin layer of wall care putty and one coat of primer upto 15 metres height including sides and soffits of the beams, fascias, parapets etc, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing 15mm bore and connection complete all as specified and directed by Engineer-in-Charge.
S & F GI tubes 15 mm bore 'medimum grade' with all fittings and fixed complete to walls and ceilings or laid in trenches or cutting chases in wall and making good to disturbed portion of wall complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing and connection complete 20 mm bore complete all as specified and directed by Engineer-in-Charge
S & F for Steel water tubing galvenised 20mm bore medium grade with all fittings and fixed to walls, ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge
S&F in repairs vitreous china ware wash hand basin white flat back, size 630x450 mm including brackets complete all as specified and directed by Engineer-in-Charge.Make: Cera/Prayag
S & F in PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC waste pipe flexible for WHB of 32mm size complete all as specified and directed by Engineer-in-Charge.
S & F in repairs wash down water closet (EWC) white with P or S trap including Flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern and plastic water closet seat & cover mild steel chromium plated or aluminised hinging device and connection to low level flushing cistern and flush pipe, etc complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, low level 10 ltr capacity, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15 mm bib tap CP, cast copper alloy with capstain head screwed down screwed for iron pipe or for brass ferrule fancy type, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs CP angle valve of cast copper alloy screwed down high pressure with capstain head screwed both ends for iron pipe or for unions and fixed 15 mm bore complete all as specified and directed by Engineer-in-Charge.
S & F in repairs CP shower roses with CP Arms, 15mm bore, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15mm dia Brass CP wall mixer for mixing hot & cold water fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S & F in repair 15mm dia Brass CP central hole basin mixer with 450mm braided connection pipe (without pop-up) for mixing hot & cold water, complete all as specified and directed by Engineer-in-Charge.
S & F in repair CP Jet Spray of Standard size for EWC alongwith CP connection pipe and all fittings as fixed Complete all as specified and directed by Engineer-in-Charge.
S & F in repairs CP Health faucet fixed with spring action and lever along with health faucet long pvc/cp chain 1.2 mtr for supply of water fitted in the existing water connection in the toilets, complete all as specified and directed by Engineer-in-Charge.
S & F in repairs corner glass shelf fixed of size 300x300mm Complete all as specified and directed by Engineer-in-Charge.
S & F tubular towel rail 600mm long of brass CP including brackets, fixed with chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms), complete all as specified and directed by Engineer-in-Charge.
S & F in repairs, chromium plated steel grating of maximum dia 150mm Complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment of walls and applying thin layer of wall care putty and prepare the smooth surface with sand paper and applying two coats of distemper oil emulsion (OBD) paint on walls complete all as specified and as directed by Engineer-in-Charge
M&L for prepartion of old decorated plastered or unplastered surfaces of ceiling including filling of holes, cracks with cement wall putty making surface even and smooth and applying one coat of distemper oil emulsion paint (OBD) complete all as specified and directed by Engineer-in-Charge
M & L for preparation of old painted wooden surfaces of any description and applying one coat of synthetic enamel paint including preparation of old painted wood and wood based surfaces of any description and positions, exc 10cm width or girth complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old painted steel surfaces of any description and applying one coat of synthetic enamel paint including preparation of old painted steel and iron surfaces of any description exc 10cm width or girth complete all as specified and directed by Engineer-in-Charge.
Demolition, Cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by the Engineer-in-Charge.
Dismantling fencing wire mesh, any type complete all as specified.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground (Posts embedded in, Concrete, brick work, masonry, etc.) complete all as specified.
Excavating in post holes (or similar holes) each not exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface, work in soft/loose soil, complete all as specified
M&L for 100 mm thick PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base with out using extra cement complete all as specified.
M & L for PCC 1:3:6 Type C2 using 40 mm graded aggregate in surface channels and drains complete all as specified and as directed by the Engineer-in-Charge.
M & L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:4:8 75mm thick type D2 using 40mm aggregate complete all as specified and directed by Engr-in-charge.
M&L for Machine pressed precast concrete coloured interlocking paver block 80mm thick rubber moulded any shape and size over and incl 25 mm thick sand layer conforming to IS 15658-2006 of grade M-40 with grey cement and no pigments complete all as specified.
M&L for Glossy finished machine pressed rubber moulded chequred tiles of any pattern/design of size 300mm x 300mm x 25mm thick laid over cement screed bed of 15mm thick in cement mortar 1:6 in floors paths etc, complete all as specified and directed by Engineer-in-charge.
M & L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping ,bed plates and the like including slightly rounded or chamfered incl necessary formwork complete all as specified and as directed by the Engr-in-Charge.
M&L for providing precast cement concrete type B0 1:2:4 (12.5mm Graded stone aggregate) louvres and jallis, 25mm thick (Measured solid) set in CM 1:4 including all mouldings but excluding frame all as specified and dirtected by Engineer-in-Charge.
Dismantling precast cement concrete louvres and jallis of any description and any position as directed.
S & F in repair galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured complete all as specified and as directed by the Engineer-in-Charge
Restraining and resecuring,existing fencing of any description including making good staples etc. as in galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured complete all as specified and as directed by the Engineer-in-Charge
S & F chain link fencing with 3.15mm dia wire and 50 x 50mm aperture including line wires of dia 3.15mm at three levels and tied to any type of standards,rails,etc including provision of binding wire complete all as specified and as directed by the Engr-in-Charge.
Dismentaling of wrought iron and mild steel work of any description not otherwise provided for,complete all as specified and as directed by the Engineer-in-Charge
M & L for hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.)& straining bolts,including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed by the Engineer-in-Charge
S & F in repair GI stay wire of size 7/4.00mm confirming to IS 2141:1979 of latest version having tensile strength 45-55 Kg/Sq mm and with minimum breaking load of individual strand 565 Kg.including fixing of brackets and tying arragement in between blast wall and blast pens.Complete all as specified and as directed by the Engr-in-Charge.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:4 (except brick)complete all as specified and as directed by the Engineer-in-Charge
M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4, except stone complete all as specified and as directed by the Engineer-in-Charge
M & L for flush pointing to random rubble masonry uncoursed or brought upto coursed, in Cement mortar 1.4 complete all as specified and as directed by the Engineer-in-Charge
Preparation of new plastered surfaces and applying two coat of oil bound distemper over a coat of 2-3mm thick layer of wall care putty to obtain the smooth surfaces complete all as specified and directed.
Preparation of new plastered external surface and applying two coat of cement base paint on external surface including cornices etc complete all as specified and directed.
M & L for prepration of new surface of steel and iron surface of any description,over 10 cm width or girth,not otherwise described and applaying two coats of synthatic enamal paint over a coat of red oxide primer.Complete all as specified and as directed by the Engr-in-Charge.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for mild steel TMT bars of 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for formwork to soffit of suspende slabs such as roof slabs, floor slabs, landing and similar works not exc 200mm thick complete all as specified and as directed by the Engineer-in-Charge
M&L for RCC Nominal Mix Type B1 1:2:4 (Using 20mm Graded stone aggregate) as in slabs supported on walls, beams and columns in floors roofs, landings, balconey, canopies, parapes, copings, shelves etc complete all as specified and as directed by the Engineer-in-Charge
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soil complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and forming benching as required. Internal dia of pipe 150mm complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipe 150 mm dia any type (salt glazed stone ware) of any size internal dia, set in cement mortar, including demolition of concrete bed and haunching complete all as directed.
M&L for Concrete bed in PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) to drain pipe 150 mm bore including packing under and haunching against the sides of pipes after they are laid and tested all as spd and directed.
S&F PVC (SWR) pipes single socketed 150mm bore, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L Precast cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in manhole coverset in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
Cleaning of underground sewage pipe (Cleaning length n.exc 30m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material/sludge to a distance of n.exc 300m and burrying in a pit and replacing manhole cover in position after cleaning complete all as specified and directed by Engineer-in-Charge for the following size of pipes:
(a) 100mm bore
(b) 150mm bore
(c) 200mm bore
Cleaning of blocked WC seat of pedestal/squatt pattern upto Ist manhole and making the drain pipe of any size full fuctional by flushing with water to entire satisfaction of engr-in charge including cleaning of 1st manhole and removing the waste material/sludge etc to a distance n. exec 300m and burning the same in pits complete all as specified and directed by Engr-in -charge.
Cleaning of blocked floor trap of bath room &kitchen etc upto 1st manhole including cleaning of gully/trap and removing the waste material/sludge etc ta a distance n. exec 300m and burring the same in pits complete all as specified and directed by Engr-in -charge.
Dewatering of septic tank/soakage well of any depth by pump or by manual after plugging of incoming sewage lines and throwing water into non residential area or in drain/nallah complete all as specified and directed by Engineer-in-Charge.
Cleaning of septic tanks, soakage well of any depth including inlet and outlet chamber and removing sludge, silt, residue both organic and in-organic nature including any other type of waste material after plugging of incoming sewage line and removing waste material/sludge etc to a distance n.exc 300m and burrying in a pit complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron reinforced concrete or PVC drain pipes, 75/100/150 mm dia, jointed in cement mortar and taking out of trenches, if required, Complete all as specified and directed by Engr-in-charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) bends of any radius, complete all as specified
S & F 110mm bore PVC (SWR) bends of any radius, complete all as specified
S & F PVC 110mm bore (SWR) branch piece, single (single Y) equal or unequal, complete all as specified
S&F PVC or CI Access door cover for 75mm bore pipe incl all asseseries complete all as specified and directed by Engineer-in-Charge.
S&F PVC or CI Access door cover for 100mm bore pipe incl all asseseries complete all as specified and directed by Engineer-in-Charge
S & F in repair, Vitreous china squating pan, orissa pattern size 580 x 440mm and making good, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc., including trap set in and including concrete Complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
M&L Point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable 1100 volt grade in and including concealed/surface , non metalic rigid pvc medium grade ISI marked conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable 1100 volts grade of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS box with modular cover plate with frame suitable for modular switches, sockets, fan regulator etc for the following :- Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
(a) One light/fan point controlled by one way switch 6 amps 240 volts
(b) One 3 pin 6 Amps switch socket out let point on independent Board
(c) One 3 pin 6 Amps switch socket out let point on same board
M&L Point wiring with 2.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable 1100 volt grade in and including concealed/surface , non metalic rigid pvc medium grade ISI marked conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable 1100 volts grade of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS box with modular cover plate with frame suitable for modular switches, sockets 16 Amps, 240 volts :- Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
S&F modular one way switch 6 Amp 240 volt marked light/fan suitable for one model etc complete as specified and directed.Make- Legrand/ Anchor/ Havells
S&F Modular 6 Amp 5 pin universal socket suitable for two model , 250 volts complete all as specified and directed by Engr-in-charge Make Legrand/ Anchor/ Havells
S&F modular switch one way 16 Amps 240 volts suitable for one model complete as specified and directed by Engr-in-charge Make- Legrand/ Anchor/ Havells
S&F Modular 6/16 Amp socket suitable for two model , 250 volts complete all as specified and directed by Engr-in-charge Make Legrand/ Anchor/ Havells
M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed. Make SSK/havells/legrand /Anchor
S&F in repair decorative Self ballasted LED Batten With Extruded Thermoplastic body with PC diffuser fitting with>120º wide Distribution 16 watt luminaire all as specified & approved by EIC.Make:-Wipro /Havells /Crompton
S&F in repair Energy saving new generation 10 W LED IP 65 bulkhead luminair with opal diffuser with 10 LED lamp etc complete as specified and directed by Engr-in-charge Make:- Wipro /Havells/Crompton
S&F in repair mirror light sleek LED mirror light provided with high output diffuser with suitable capacity driver with all comptonants as per manufacturer etc complete as specified and directed Make:- Wipro/Havells/Crompton
S&F surface mounted round type energy saving ceiling mounted decorative LED 8 watt luminair with opal diffuser for soft light with suitable driver etc complete as specified and directed by Engr-in-charge. Make:- Wipro/Havells/Crompton
S&F modular step type two model fan regulator suitable for 120 watt 250 volts complete as specified and directed by Engr-in-charge Make- Legrand/ Anchor/ Havells or equivalent approved by GE
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 12 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed. Make- Legrand/ ABB/ Havells
S&F in repair MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA etc all as specified and directed. Make- Legrand/ ABB/ Havells
S&F in repair MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40-63 Amps 10 KA breaking capacity etc all as specified and directed. Make- Legrand/ ABB/ Havells
M&L in repair for sub main wiring with two single core, PVC insulated,ISI marked, unsheathed, 1100 volts grade multistranded copper conductor FRLS cable drawn into and including suitable size non metalic rigid pvc conduit (ISI marked) concealed/surface with all accessories and including one single core pvc insulated multistranded unsheathed 1100 volts grade copper conductor FRLS cable as earth wire 2x10.0 sqmm + 1x10.0 sqmm earth wire size complete all as directed & specified.
S&F in repair switch socket combination 2 in 3 pin 5 and 15 Amps flush type ISI marked universal suitable for 240 volts etc complete as specified and directed Make-SSK or equivalent approved by GE
M/S GULZAR ENTERPRISES
M/S GULAM AHMAD ABDUL SAMAD
M/S FAROOQ AND SONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .