Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.4 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹33.7 L+₹2.8 L (9.06%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-2 | Rejected-Finance L-2 | |
| 3 | l-3₹36.6 L+₹5.7 L (18.4%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | l-3 | Rejected-Finance L-3 | |
| 4 | L-4₹37.4 L+₹6.5 L (21.0%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹37.8 L+₹6.9 L (22.1%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Jun 2023, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR / ROUTINE MAINTENANCE OF DG SETS , AMF PANELS, AC WORKS AND OTHER MISC E/M ITEMS INSTALLED AT DIFFERENT LOCATION AT MCC BASANT NAGAR IN AOR OF GE (AF) FARIDABAD
2023_MES_591136_1
GE (FBD)/AF-06/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION BASANT NAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) FARIDABAD
₹90,000
Yes
2 Aug 2023
25 Apr 2023
5 Jun 2023
25 Apr 2023
2 Jun 2023
9 May 2023
25 Apr 2023 - 2 May 2023
Amount
Maintenance/repair to 320 KVA Gen set installed at sub station by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Engineer-in-Charge. Note :-(i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair. SPARE PARTS FOR DG SET
Supply only Element lub oil filter Cartrige complete all as specified and directed by Engineer-in-Charge.
Supply only fuel filtter Cartage complete all as specified and directed by Engineer-in-Charge.
Supply only Pre Filter Assembly complete all as specified and directed by Engineer-in-Charge.
Supply only seal 'O' ring complete all as specified and directed by Engineer-in-Charge.
Supply only KOEL Care genuine oil complete all as specified and directed by Engineer-in-Charge.
Supply only K-COOL super plus Coolent complete all as specified and directed by Engineer-in-Charge.
Supply only Air Filter for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water complete all as specified and directed by Engineer-in-Charge.
Supply only Battery terminals complete all as specified and directed by Engineer-in-Charge.
Maintenance/repair to 50/ 75 / 80 KVA Gen set " Greevs" installed at sub station in Basant Nagar Officer's Mess by replacement of lubricant oil filter fuel oil filter bye pass filter, “O’ ring, fuel filter water separator assembly, draining out un serviceable engine oil, cleaning of pump, checking & tightening of mounting nut & bolts, crank case, cleaning of valves, battery terminals, checking of radiator, PH value of coolant, topping with premixed coolant and inhibitor corrosion testing the engine on load and checking for any leakage of oil/fuel/coolant complete all as specified and directed by Engineer-in-Charge. Note :- (i) Parts required for replacement will be measured and paid separately under Schedule ‘A’ item (ii) The contractor will be responsible for attending any complaint/defect occurs to DG set at odd hours during operation. If the defects are not attended within 4-6 hrs recovery of Rs. 300/- per day will be effected (iii) The contractor has to submit the responsibility certificate of all changed/repaired parts for six months from the date of servicing/repair. SPARE PARTS FOR DG SET
Supply only Element lub oil filter Cartrige complete all as specified and directed by Engineer-in-Charge.
Supply only fuel filtter Cartage complete all as specified and directed by Engineer-in-Charge.
Supply only Pre Filter Assembly complete all as specified and directed by Engineer-in-Charge.
Supply only seal 'O' ring Make- Kirloskar complete all as specified and directed by Engineer-in-Charge.
Supply only genuine Engine oil Make- Servo/Castrole complete all as specified and directed by Engineer-in-Charge.
Supply only Coolent complete all as specified and directed by Engineer-in-Charge.
Supply only Air Filter for 75 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only distilled water complete all as specified and directed by Engineer-in-Charge.
M&L for repair of PCB suitable for 250/320 KVA DG set AMF panel complete all as specified and directed by Engineer-in-Charge.
M&L for repair of AVR Unit of 250/320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L for Repair of Self starter of 250/320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of fuel pipe of DG set connecting from inlet of the tank to dg set complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Digital maltifunctional power meter for AMF panel complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of V belt for radiator fan suitable for 320 KVA DG set as per sample complete all as specified and directed by Engineer-in-Charge.
M&L for repair/replacement of battery 12 volts, 180 amh complete complete all as specified and directed by Engineer-in-Charge. Make :Exide/Amron/SF.
M&L for complete oherhauling of Engine incl opening of engine head of 250 / 320 KVA DG Set carefully and Servicing of internal parts of engine, piston, lining etc and entire assembly and fixing the parts after opening complete all as specified and directed by Engineer-in-Charge. Note :- Spare part are paid separately.
M&L for replacement of the following unserviceable parts of 320 KVA DG set as per the existing Kirloskar model of the DG set complete all as specified and directed by Engineer-in-Charge:- Piston
Ring set
Piston pin
CR Bearing
Head valve
Head Gas kit
Head seal
Packing kit of the engine
S&F in replacement of water pump suitable for 250/ 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge. Make- Kirloskar
M&L for replacement of engine lining after complete opening of engine of 250/ 320 KVA DG Set including topup of engine oil complete all as specified and directed by Engineer-in-Charge.
M&L for Repair of fuel nozzeles of 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
M&L for repair of turbocharger of 320 KVA DG SET complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Battery charger 24 V DC with digital display complete all as specified and directed by Engineer-in-Charge.
M&L for Design, development, supply commissioning and testing EHCC certified ground tubular effective chemical earthing system (CPRI tested for 15 KA current capacity for LT Iine) highly anticorrosive long life electrode with and including adequate protective coating to withstand servere weather conditions in the earth pit of the standard size comprising of 40mm x 3m Long Copper rod as primary conductor and hollow copper tube of 80mm x 3m long as secondary conductor to install with suitable connecting terminal confirming of IS 3043 : 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture (CCM) 20 Kg per bag (3 bag per kit) minimum or sufficient quanitities required as per site complete including RCC earthing pit cover , material and labour complete all as specified and directed by Engineer-in-Charge. Note :- Excavation / drilling hole in hard soil/rock is included in the rate quoted.
Supply and fix in repair Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
Supply and fixing contactor 100 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as specified and directed by Engineer-in-Charge. Make : Indo Asian/Havells/L&T/BCH
Supply and fixing contactor 63 Amp 3 pole for time switch astro type/Nature switch fitted inside box complete with all electrical connection after dismantling old one complete all as specified and directed by Engineer-in-Charge..Make : Indo Asian/Havells/L&T/BCH
Suply and fix in replacement of Sheet metal enclosure for MCCB 3P, one no complete all as specified and directed by Engineer-in-Charge.
S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415, 4 way complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 400 Amp ,3 pole, adjustable type ,36 KA including under voltage/over voltage relay complete all as specified and directed by Engineer-in-Charge. Make : -HPL TABBASIX2200C3P/Havells/indoasian)
Supply and fix in replacement of Onload Changover switch 630 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Onload Changover switch 400 Amp, 4 pole ,415 V,50 Hz in sheet metal enclosure complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair,MCCB 250 Amp ,3 pole, adjustable type ,25KA including under voltage/over voltage relay complete all as specified and directed by Engineer-in-Charge. Make : -HPL TABBASIX2200C3P/Havells/indoasian)
M & L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge.
S& fixing LED flood light luminarie 70 W with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 4 core 10 sq. mm nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge. Make : Havells/Plaza/Polycab
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 sq mm single core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engineer-in-Charge.
M & L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches all as specified and directed by Engineer-in Charge.
M & Labour for sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for rectification of fault in AMF panel of DG set and testing on load ranging from 80 to 320KVA complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of relay of AMF panel complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of display panel of AMF suitable for DG set rating 80 to 320 KVA along with all connections and push buttons for mode change and start stop button complete all as specified and directed by Engineer-in-Charge.
S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2mm thick green / blue colour ISI marked embozzed for up to 3.3 KV complete all as specified and directed by Engineer-in-Charge.
M& L for maintenance, servicing and testing of AMF panel suitable for 320 KVA DG set by cleaning and tightening of all the connections, cleaing of all links of circuit breakers using CRC and testing of breakers for smooth operations including vaccum cleaning / blower cleaning of the entire panel from the inside all as specified and directed by Engineer -in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 630 sq mm x 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCCB 630 Amps ,4 Pole ,50 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCCB 400 Amps ,4 Pole ,36 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCCB 250 Amps ,4 Pole ,25 KA ,50 Hz ,415 Volt including under voltage/over voltage relay,adjustable overload setting and short circuit setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 300 to 400 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 630 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair on load changeover switch 400 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair on load changeover switch 630 amp 4 pole ,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED post top lantern 70 watt with die cast aluminum pipe spigot ,aluminium PDC heat sink ,opal diffuser IP65 complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable duct cover made of iron of size 320mm x 800 mm of thickness 3.0 mm complete all as specified and directed by Engineer-in-Charge.
S & F rubber insulation mat of size 1.8 mtr x0.9mtr wide 2 mm thick red/blue colour ISI marked embozzed for up to 33 KV as per latest IS complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting 1x16 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
M&L for providing Display board of size 2 m x 1 m x1 cm madeup with acrylic sheet material consisting of " GE(AF) Faridabad and MES Logo " with SOP /description as provided by Engineer-in-charge in English / Hindi in Capital Letter at the Top complete with fixing arrangements to the wall complete all as specified and directed by Engineer-in-Charge.
M &L Repair maintainance of oil cooled servo voltage stablizer of capacity 400 to 630 KVA 3 phase by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts /component complete all as specified and directed by Engineer-in-Charge. Note:- The replacement spare parts shall be measured and paid separately.
Supply Only spare part of the Voltage stablizer 400/630 KVA as following complete all as specified and directed by Engineer-in-Charge.:- RC Network
AC Synchronous Motor 10 Kg
Spring loaded finger
Microproccessor Based eletronic control board
M & L for Repair and Maintenance of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting and checking the Indoor/outdoor units for noise free operation (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower.(d) Greasing/Oiling of condenser fan motor and blower motor. (e)Checking for any refrigerant leakage. (f) Checking for serviceability of remote control unit.
Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 2 TR complete all as specified and directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
S/F in replacement of running capacitor 30/36 mfd for split type AC unit as required at Site and as directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
M & L for Taking out burnt condenser fan motor and rewinding of condenser fan motor of split type AC units of capacity 1.5/2 TR including replacement of worn out bush and bearing complete all as specified and directed by Engineer-in-Charge
M & L for Taking out burnt blower motor and rewinding of blower motor of split type AC units of capacity1.5/ 2 TR including replacement of worn out bush and bearing ccomplete all as specified and directed by Engineer-in-Charge
M & L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new reciprocating type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge. Make :- Kirloskar/Takemshah/ Voltas /Daikin
M & L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new rotary type compressor with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge. Make :- Kirloskar/Takemshah/ Voltas /Daikin
M & L for Disconnecting and taking down burnt compressor of capacity 1.5 TR with CFC free Refrigerent (R410a,R32) from split type AC unit and Supply and Fix new rotary/reciprocating type compressor with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge
M&L for repair to gas leakage of split type AC unit of capacity 1.5/2TR capacity including pressure testing, dehydration and gas charging complete all as specified and directed by Engineer-in-Charge
M&L for replacement of electronic remote control unit of split type A/C unit (cordless type) 1.5 Ton complete of existing make all as specified and directed by Engr-in-charge.
M&L for replacement of electronic remote control unit of split type A/C unit (cordless type) 2.0 Ton complete of existing make all as specified and directed by Engr-in-charge.
Taking out unserviceable PCB from 1.5 /2 TR split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing complete all as specified and directed by Engineer-in-Charge
Taking out unserviceable PCB from 1.5 /2 TR inverter split type A/C unit and refixing the serviceable PCB after repair from workshop complete testing complete all as specified and directed by Engineer-in-Charge
M&L for replacement of unserviceable inverter type PCB from the existing inverter split type A/C unit 1.5/2.0 Ton complete of existing make ,testing complete all as specified and directed by Engineer-in-Charge
M&L for taking out unserviceable blower motor from split type A/C of capacity 1.5 /2 Ton unit complete and supply and fix new blower motor of the existing make complete all as specified and directed by Engineer-in-Charge. Make:LG/Sidwal/Voltas
Material and Labour for providing insulation 9mm thick for dia 1/4",3/8",1/2",5/8",6/8" copper tubing’s from Indoor to outdoor units with foam insulation followed with clamps complete all as specified and directed by Engineer-in-Charge
Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete all as specified and directed by Engineer-in-Charge
M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as specified and directed by Engineer-in-Charge
M&L in replacement copper tubing 15mm outer dia complete all as specified and directed by Engineer-in-Charge
M & L for Repair & maintenance of water coolers of capacity 40/80/150 Ltrs comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspection, taking down, opening, dismantling, decaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning.(c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning (i) Testing of water cooler after repair
Supply & fixing in replacement of thermostat switch suitable for water cooler 40/80 as required at site complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement fan motor capacitor 2.5/3.15mfd complete all as specified and directed by Engineer-in-Charge
Supply & fixing in replacement of starting relay as required at site for water coolers 40/80 Ltrs capacity complete including connecting, testing complete all as specified and directed by Engineer-in-Charge.
M & L for Disconnecting & taking out compressor ('R type) from water cooler for any capacity and supply and fix the new compressor including flushing dehydration and gas charging complete all as specified and directed by Engineer-in-Charge.Make - Kirloskar/Takemshah/ voltas / Daikin
Supply and fixing in repair PVC insulated Sheathed, Copper conductor,6 sq mm ,3 core (flexible) cable,1100 Volts,complete all as specified and directed by Engineer-in-Charge. Make - KEI/Finolex/Polycab/Havells
Supply and fixing in repair PVC insulated Sheathed, Copper conductor,4 sq mm ,3 core (flexible) cable,1100 Volts,complete all as specified and directed by Engineer-in-Charge. Make :-KEI/Finolex/Polycab/Havells
M & L for Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of wood pads(set of three)as per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement the new desert cooler pump. including testing for proper functioning complete all as specified and directed by Engineer-in-Charge. Make-(1) Elpar (2) Khaitan (3) CG
Supply and fix new exhaust fan kit of desert cooler with super enameled copper wire complete all as specified and directed by Engineer-in-Charge. Make-(1) Elpar (2) Khaitan (3) CG
M & L for Repair and Maintenance of window type AC's of capacity 1.5 TR comprising of the following tasks at different locations including Refixing, commissioning and testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation.
S&F in replacement 'R' type compressor for Window type AC,1.5 TR as per existing make and including taking out old unserviceable one,flushing, dehydration and gas changing complete all as specified and directed by Engineer-in-Charge. Make - Kirloskar/Takemshah/ voltas / Daikin
S&F in replacement of copper condensor coil of window type AC 1.5 TR including after taking out old unserviceable coil and including dehydration ,charging complete all as specified and directed by Engineer-in-Charge.
Repair & maintenance of Refrigerator of any capacity comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning (j) Testing of Refrigerator after repair.
M & L for Repair & maintenance of voltage stabilizer of capacity 5 KVA comprising of the following tasks at different location complete all as specified and directed by Engr-in-Charge. (a) Rewinding of Transformer copper coil with new copper wire as per existing gauge (b) Time delay relay-01 No. c) Cut out relay-01 No. (d) printed citcuit relay- 01 No.
M & L for Dismantling of Split type AC 1.5/2.0 TR capacity from position after including disconnecting all connections between indoor and out door units,shifting,backup refrigerant for reuse and install at a place where directed carefully,including cutting on wall,making hole and make good disturbed surface properly matching surface,inspecting, servicing and refilling refrigerant and testing complete all as specified and directed by Engineer-in-Charge.
M & L for the nitrogen pressure testing after installation of condenser coil of 5.5 TR split AC and complete pressure testing for the no leakage confirmation complete all as specified and directed by Engineer-in-Charge.
M&L for gas leakgae detection including dehydration of complete 5.5 TR split AC and vaccuming the system with vaccume pump and recharging the suitable refrigerent complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of copper tubing 10mm outer dia suitable for 5.5 TR split AC capacity complete all as specified and directed by Engineer-in-Charge.
M & L for Taking out the unserviceable condensor motor of 5.5 ton AC and S&F the new condenser motor of 5.5 TR split AC of existing make complete all as specified and directed by Engineer-in-Charge.
M & L for Disconnecting and taking down burnt compressor of capacity 5.5 TR from ductable split type unit and Supply and Fix new compressor of exsiting make with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge. Make - Kirloskar/Takemshah/ voltas / Daikin
M & L for Taking out unserviceable indoor unit and supply and fix the new indoor unit of 2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed by Engineer-in-Charge. Make : Hitachi/Blue star/LG/Voltas
Supply and fix in repair single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20-32 amps complete all as specified and directed by Engineer-in-Charge. Make :- L&T/Havells/Iegrand
Supply and fix in repair outdoor unit fan blade for 5.5 TR split AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair outdoor unit fan blade for 2.0/1.5 TR split AC complete all as specified and directed by Engineer-in-Charge.
M&L for Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and Fix new inverter type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge. Make - Kirloskar/Takemshah/ voltas / Daikin
M&L for Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and Fix new inverter type compressor with charging of refrigerent (R410A,R32,R134A)after dehydration testing and vaccumming one as per existing model complete including testing complete all as specified and directed by Engineer-in-Charge. Make - Kirloskar/Takemshah/ voltas / Daikin
M&L for Repair & maintenance of Deep Freezer 300 Ltrs capacity comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. c) Inspecting the leakage in the system. d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. f) Inspection of all electrical parts. g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning .
S&F following items for solar water heater 500/1000 LPD complete all as specified and directed by Engineer-in-Charge.
Supply and install absorber Plate made of copper sheet, laser or ultrasonically welded to copper tubes with FlangesL-1860 W-1240 H-100, weight 36 kg working pressure 80 KPA complete all as specified and directed by Engineer-in-Charge.
Supply and fix Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore all as specified and directed by Engineer-in-charge
Supply and fix Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore complete all as specified and directed by Engineer-in-Charge.
Single pane 3.2 mm tempered low iron glass collector complete all as specified and directed by Engineer-in-Charge.
Supply & install 100 Ltr Hot water Tank of material SS-304 with Manhole & Stand complete all as specified and directed by Engineer-in-Charge.
Supply & install Makeup Tank for heat exchanger of 5 Liter with ball cock complete all as specified and directed by Engineer-in-Charge.
Supply and install heating element 3 kw suitable for solar water heater of 100 to 300 litres all as specified and directed by Engineer-in- Charge.
Supply & install Back Plact Collector complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper condensor coil for split AC 2 TR complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper condensor coil for split AC 1.5 TR complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper evaporater coil for split AC 2 TR complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement copper evaporater coil for split AC 1.5 TR complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length) complete all as specified and directed by Engineer-in-Charge.Make - KEI/Finolex/Polycab/Havells
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length) complete all as specified and directed by Engineer-in-Charge.Make - KEI/Finolex/Polycab/Havells
S/Fix in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar with incomer as 4 pole MCCB 240/430V for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old one.Make: Legrand/L&T/Havells
Supply and install in replacement MCCB TPN fixed type 125 Amps rated with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge. Make: Legrand/L&T/Havells
Supply & fixing in replacement of MCB SP 6 t0 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge. Make: Legrand/L&T/Havells
Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed by Engineer-in-Charge at site.Make - Supreme/ Kalinga/ Astral
S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer-in-Charge. Make - Supreme/ Kalinga/ Astral
Supply and installation of PVC Duct 100 mm width For AC copper pipes and insulation complete all as specified and directed by Engineer-in-Charge. Make - Supreme/ Kalinga/ Astral
Taking down carefully water heater (Geyser) any capacity any make after removing electric & water connections from existing system for carrying out repairs(Repairs will be measured and paid separately) and refixing the same after carrying out necessary repairs to original place complete all as specified and directed by Engineer-in-Charge.
Removing existing hot & cold water copper/PVC flexible pipe connection from geyser and S&F new brass chromium plated water connection pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete all as specified and directed by Engineer-in-Charge.
Replacement of heating element 1.5 kW for 35ltrs capacity geyser ISI marked complete all as specified and directed by Engineer-in-Charge. Make : Bajaj/Theta/CG
Replacement of thermo static switch of geyser complete all as specified and directed by Engineer-in-Charge.Make : Bajaj/Theta/CG
S& F geyser assembly including gasket and nuts and bolts complete with fixing arrangement complete all as specified and directed by Engineer-in-Charge. Make : Bajaj/Theta/CG
S&F in replacement of water storage tank of suitable for 25ltrs capacity incl glass wool complete all as specified and directed by Engineer-in-Charge.Make : Bajaj/Theta/CG
Supply and install wall mounted stand for mounting indoor unit of split AC complete with all fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Supply and install wall mounted stand for mounting outdoor unit of split AC complete with all fixing arrangement complete all as specified and directed by Engineer-in-Charge.
M/S Anand Enterprises
Saini Enterprises
Shiv Enterprises
sheetal engineering
Singh Associates
UNIVERSAL ENTERPRISES
Akhil Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .