| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC SCF 134 1ST FLOOR ROSE GARDEN COMPLEX GT ROAD BATHINDA 151001 PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹4.5 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹5.1 Cr+₹56.3 L (12.5%)Rejected-Finance | ₹5.1 Cr+₹56.3 L (12.5%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹5.5 Cr+₹97.8 L (21.7%)Rejected-Finance | ₹5.5 Cr+₹97.8 L (21.7%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹5.6 Cr+₹1.0 Cr (23.1%)Rejected-Finance 100 FEET ROAD NEAR POWER HOUSE ROAD CHOWK BATHINDA | BATHINDA | BATHINDA | PUNJAB | ₹5.6 Cr+₹1.0 Cr (23.1%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹5.6 Cr+₹1.1 Cr (25.0%)Rejected-Finance PLOT NO D 25 INDUSTRIAL GROWTH CENTRE MANSA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹5.6 Cr+₹1.1 Cr (25.0%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹5.9 Cr
EMD Value
₹6.2 L
Closing Date
27 Jun 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
CONSTRUCTION SECURITY CUM PERIMETER WALL AND WATCH TOWERS AT BATHINDA MIL STATION
2023_MES_574452_1
CE BTZ/BTD/TOKEN-27 OF 2022-23
Open Tender
Civil Works
Lump-sum
457 days
Bathinda
As per NIT
10 documents required · 10 mandatory
₹3,000
GE (P) Bathinda
₹6.2 L
Yes
14 Jul 2023
11 Jan 2023
29 Jun 2023
11 Jan 2023
27 Jun 2023
13 Jun 2023
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Lump sum price worked out by the tenderer for “PATH WORK" as listed in Schedule ‘A’ Section - II (Part-I)
Sch 'A' Sec - II (Part-II), (PATH WORK)
Supply and laying factory made kerb stone of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed.
Material and labour for Forming Contraction (Dummy) joints 30mm deep x 10mm wide, filling the Joints with and including bitumen and sand (1:3) by weight complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Forming Construction joint 30mm deep x 10mm wide, filling the Joints with and including bitumen and sand (1:3) by weight complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Forming 20mm thick Expansion joints filled with pre-formed bituminous filler board and top 30mm primed and filling the Joints with and including bitumen and sand (1:3) by weight ( Thickness of concrete slab in 100mm) complete all as specified and as directed by the Engineer-in-Charge.
Subtotal
Lump sum price worked out by the tenderer for “SECURITY CUM PERIMETER WALL WORK" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), (SECURITY CUM PERIMETER WALL WORK)
Supply only concertina coil with wire diametre 2.5mm dia and blade size 15mmx12mmx0.5mm, spacing of blade 26mm, complete all as specified and as directed.
Fixing only concertina coil 600mm dia having 50 rounds per 6 meter length with punched tape, concertina coil shall be fixed over wall complete all as specified and as directed. Note ;- For the purpose of measurement the length of wall shall be measured and paid.
Subtotal
Lump sum price worked out by the tenderer for “STEEL GATE WORK" as listed in Schedule ‘A’ Section - IV
Sch 'A' Sec - V (TEMPORARY BARRICADING WORK)
Supply and fixing Mild steel work using MS pipe, angle iron & flat iron, drilled as in fencing posts and struts for temporary barricading etc including cutting tops to shape as directed, drilling holes etc.; flat iron fillets (for securing/fixing GI sheets etc.) including all necessary nut bolting or riveting, etc., and similar work including excavation in post holes for MS post embedding in ground complete all as specified and as directed.
Supply and fixing Galvanised, corrugated mild steel sheeting 0.80nn thick with grade of zinc coating 275, with two corrugations side lap, fixed with nut bolts and washers, as in temporary barricading (fixing between two Nos MS posts) and similar work complete all as specified and as directed. Note : Nut bolts and washer shall be measured and paid separately under appropriate item of BOQ).
Blank
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - VI (Part-I)
Sch 'A' Sec - VI (Part-II), EXTERNAL ELECTRIFICATION WORKS
Supply , Instllation, commissioning and testing diesel engine driven, water cooled, silent Generating Set 32 KW/40KVA capacity, 1500RPM, suitable capacity of BHP to give output 40 KVA, with electronic governor, 3 phase, 415 volts, 50 Hz, power factor 0.8 applicable for supplying power to varying electrical load for unlimited hours with 10% over load capacity, complete with self starting system with AMF panel (automatic starting of main failure control panel), including common base plate, floor mounted with anti vibration pads, factory asembled complete fitted in acoustic enclosure (sound proof canopy of authorised OEM of manufacture's of DG set given in appedix 'B' approved by National Physical laboratory as per CPCB latest norms/regulation, including PCC foundation/platform for generating set as per manufacture's instruction, complete including accessories, equipment control panel etc and confirming to conditon under IS-4722 BS 5514/2613/5000/10002/13664 complete all as specified and as directed and comprising with the following:-
Alternator:- 32 KW output at 0.8 PF AC 3 phase 4 wire 415 volts 50 C/S, brush less, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces, class 'H' insulation with IP-23 protection and voltage regulation +/- 1.5% as per IS-4722 or BS 2613-1970
Diesel engine: Diesel engine multi cylinder 4 stroke, water cooled electric start suitable capacity to drive above alternator independently, coupled directly through flexible coupling cold starting, speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommedations, fuel lines, exhaust pipe duly insulated with asbstos rope and with support and residential silencer mufflers etc for continuous operation and standard accessories, sump preheaters etc
Control panel :- The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for the followings:- (i) Gen set controller microprocessor based multifunctional with LED display for engine water temperature, Lub oil pressure, Engine RPM, Engine shut down display, total Hours run and suitable for protection against high water pressure, low lub oil pressure, over speed and battery charger failure. (ii) Digital multifunctional meter with LED display suitable to display all electrical parameters of individual phase such as Voltage, current, frequency, KVA, KW, KWH, Power factor and having RS 485 communication port complete with appropriate CT's and control wiring. (iii) MCCB 4 pole 415 volt AC of suitbale capacity not less than 63 Amps all as required complete with copper bus bar all as per standard engineering practice and as per manufacturer reomendations. (iv) HRC fuses for protection as per standard engineering practice and manufacturer recommendations for protection of meters etc.
Electric Starter Equipment:- The equipment will comprise the following:- (i) Start Stop push button (ii) Maint free Battery duly initial charged & Battery lead of adequate capacity (iii) Starter motor (iv) Starter gearing (v) Alternator/dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut.
Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is off position.
Note:- (a) Cost of maintainance free batteries as per recoomondations of manufacture shall be deemed included in unit rate quoted by contractor. (b) Cost of PCC foundation as per reccomondations of manufacturer shall be deemed included in unit rate quoted by contractor. (c) Pre commissioning test shall be carried out by rep of accepting officer in presence of Contractor, Engr-in-charge and JE. All necessary equipments, consumables (fuel) and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor. (d) Emission control device shall be supplied & fitted with in overall cost quoted
Supply, installation, commissioning and testing of factory made cubical type LT panel Board of Suitable size (CPRI approved) out door type dust proof, vermin proof with IP 65 protection made out of CRCA sheet 3.15 mm thick powder coated with seven tank process, fully compartmentalized inside panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with aluminum bus bar capacity 100 Amps 04 Nos Three Phase and neutral (TPN) (in Separate chamber), bus bar fixed on epoxy coated insulator and provision with 1100 volt grade heat shrinkable type sleeves and housed in independent chamber having access both from front and back side, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-
MCCB 63 Amp, 4 Pole, 415 V, 25KA rupturing capacity, Thermal megnatic relay adjustable type – 01 No (incoming)
MCB 32 Amp, TPN, 415 V, 16KA – 02 Nos (Out going)
MCB 16 Amp, TPN, 415 V, 10KA – 02 Nos (for timer)
LED Indicated Lamp (R,Y,B) one Set-01
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.
Supply and fixing energy efficient LED street light fitting of 70W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications, complete all as specified and directed :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) CRI : Morethan 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) Note :- Bracket for fixing and cable for connection shall be measured and paid separately under appropriate item of BOQ
Material and labour for bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket along PCC pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 3x1.5 Sqmm 1100 Volt , draw through steel conduit for connection to street light from junction box complete all as specified and as directed. Note: Steel conduit shall be measured and paid separately under appropriate item of BOQ
Supply and fixing rigid mild steel stove enamelled conduit of size 20 mm external dia fixed along PCC pole with clamps made out of MS Flat iron size 25x3 mm at not more than 100cm c/c, including suitable size of nuts, bolts and washers including painting to pipe, MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply and laying GI tubing light grade of size 80 mm bore, ISI marked, including fittings (elbow, tee, socket etc) laid in trenches, under road for cable protection complete all as specified and as directed. (Note:- Excavation and earthwork as required shall be measured and paid separately under respective item of Sch.)
Supply and laying GI tubing light grade of size 40 mm bore, ISI marked, including fittings (elbow, tee, socket etc) laid in trenches, under road for cable protection complete all as specified and as directed. (Note:- Excavation and earthwork as required shall be measured and paid separately under respective item of Sch.)
Supply and fixing GI tubing light grade of size 40 mm bore, ISI marked, including fittings (elbow, tee, socket etc) fixed along poles/walls for cable protection with clamps made out of MS Flat iron size 25x3 mm at not more than 100cm c/c, including suitable size of nuts, bolts and washers including painting to pipe, MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Sand cushioning, with dry and clean river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32 mm x 6 mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI medium grade pipe upto test point or upto main switch board or metallic bodies of electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI medium grade pipe upto test point or upto main switch board or metallic bodies of electric equipment, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Supply and fixing energy efficient LED wide angle flood light fittings of 200 W capacity with driver, Epoxy powder coated pressure die cast aluminium alloy housing and front cover clear toughned glass, including electric connection with suitable copper cable and including fixing arrangement with suitable nut bolts or any hanging hook etc, complete fitting and all accessories with following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : More than 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing cable junction box of Size 225mm x 295mm x 122mm or any other higher size (Suitable for Pole mounting) complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree of IP 65 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60695-22, IEC 60670-2 to 5 and grey color according to RAL-9011/ 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 1 Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Clamps and screws for fixing of junction box shall be made of SS
Supply and fixing cable junction box of Size 225mm x 295mm x 122mm or any other higher size (Suitable for wall mounting) complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree of IP 65 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60695-22, IEC 60670-2 to 5 and grey color according to RAL-9011/ 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete (h) Manufacturer should submit routine test certificate for junction box. (j) Clamps and screws for fixing of junction box shall be made of SS
Supply and fixing cable junction box of Size 130mm x 130mm x 77mm or any other higher size (Suitable for wall mounting) complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree of IP 65 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60695-22, IEC 60670-2 to 5 and grey color according to RAL-9011/ 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete (h) Manufacturer should submit routine test certificate for junction box. (j) Clamps and screws for fixing of junction box shall be made of SS
Supply and fixing Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of angle iron 25 x 3 mm, welded/riveted on back side of plate, fixed and grounted in position with with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing of automatic street light control switch with infrared sensor based Nature Switch & voltage monitoring system (VMS). Nature switch operation should be based on Natural Light Lux level. Required illuminance level for Switching ON is ≤ 30 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have pert night operation facility of min. 4 hrs. to max 12 hrs. VMS should have Adjustable over & under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The sensor & VMS along with suitable Power Contractor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Terninate proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. sensor & VMS By-Pass option) with 3nos. Contractors, 3 Nos incoming MCBs & 3 Nos outgoing MCBs of 16-20 Amps each & Circuit wiring (Copper) of min. 6 sqmm omplete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED Post Top light fitting of 25W decorative design, Glare-free and better uniformity compete fitting all with accessories and LED lamp, fixing on and including 50mm dia GI pipe light grade of length 2.5 mtr embeded in PCC block of size 0.3x0.3x0.5m made with PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate, including making electric connection with suitable size of wire, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficiency of luminaire should be minimum 100 lumen per watt. (b) Input voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10*C to plus 50*C (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) CRI : More than 70 and CCT : 5700K (g) IP rating : IP 65 (h) IK rating : minimum IK 07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should e complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10kV (inbuilt +extended) (m) Lens - High Efficiency wide angle lens. (n) BIS approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Subtotal
Lump sum price worked out by the tenderer for “DISMANTLING AND DEMOLITION WORK (B/R AND E/M WORKS)" as listed in Schedule ‘A’ Section - VII (Part-I)
Sch 'A' Sec - VII (Part-II), DISMANTLING AND DEMOLITION WORK (B/R AND E/M WORKS)
Dismantling existing galvanised barbed wire of any type, size and thickness complete all as specified and as directed by Engineer-in-Charge. (each line wire to be measured)
Dismantling and taking out GI sheet, MS posts and struts carefully after un screwing nut bolts (temporary barricading), removing all material from site and including making good disturbed surface complete all as specified and as directed.
Dismantling and taking down cross arms (MS channel, angle section etc) from LT pole complete all as specified and as directed.
Dismantling and taking down old street lights (any type) including brackets and connection wire from pole complete all as specified and as directed.
Dismantling and taking out old PCC pole of any size/condition and embeded in any material (including foundation) and removing the same from site complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION AND EARTHWORK " as listed in Schedule ‘A’ Section - VIII
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), INTERNAL ELECTRIFICATION WORKS
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ/Sch 'A').
All as per above Srl item No. 49 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep, suitable size ) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Material and labour for surface Point wiring (on metal surface or on wall as per existing ) for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep and 1.6mm thick sheet, suitable size), including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. Including all material required for fixing of pipe, junction box, terminal box etc on metal or wall surface complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ/Sch 'A').
All as per above Srl item No. 52 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
Material and labour for surface Point wiring (on metal surface or on wall as per existing ) for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep, suitable size ) including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. Including all material required for fixing of pipe, junction box, terminal box etc on metal or wall surface complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
Supply and hanging /fixing wall mounted fan of 400 mm sweep having energy consumption 50watt, single phase AC Supply, 230 V, 50Hz, Aerodynamically designed and balance transparent blades, thermal overload protected motor, white colour, having pull cord and minimum 72 cum/hr air delivery, hanging in position including making connection complete all as specified and as directed.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Material and labour for sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Supply and fixing LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Subtotal
BANSI BUILDER AND CONTRACTORS PVT LTD
M/s MAKHAN ENTERPRISES
JB Infrastructure
M/S VERMA BUILDERS & DEVELOPERS
M/s Luxmi Constructions
TARUN CONSTRUCTION COMPANY
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
Kartik Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .