Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.2 L+₹5.9 L (70.1%)Rejected-Finance ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | L2 | Rejected-Finance L1 being accept | |
| 3 | L3₹14.6 L+₹6.3 L (74.9%)Rejected-Finance | L3 | Rejected-Finance L1 being accept | |
| 4 | L4₹15.1 L+₹6.7 L (80.4%)Rejected-Finance CHENNAI | L4 | Rejected-Finance L1 being accept | |
| 5 | L5₹15.5 L+₹7.1 L (85.0%)Rejected-Finance | L5 | Rejected-Finance L1 being accept |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
10 Aug 2020, 6:00 pmClosed
GE TIRUNELVELI
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
REPAIRS/REPLACEMENT OF INTERNAL WIRING, RENEWAL OF FTL/CFL LIGHT FAN AND GEYSERS IN TECH AREA AT KATTABOMAN UNDER GE TIRUNELVELI
2020_MES_360900_1
GE/TVL/8112
Open Tender
Miscellaneous Works
Item Rate
180 days
Vijayanarayanam
As per NIT/Tender documents
8 documents required · 8 mandatory
₹500
GE TIRUNELVELI
₹29,000
Yes
14 Oct 2020
14 Jul 2020
12 Aug 2020
14 Jul 2020
10 Aug 2020
28 Jul 2020
14 Jul 2020 - 24 Jul 2020
Amount
SCHEDULE 'A' (INTERNAL ELECTRIFICATION)
Taking down carefully copper/aluminium point wiring (light, fan, socket and power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc and making good disturbed surfaces of walls, floors etc.
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M&L Point Wiring with two single core 1100 V grade conforming to IS-694 of 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLS) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including PVC Casing and Caping medium grade of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on metal flush box, factory made of suitable size with frame and cover plate Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed one Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLS) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly complete all as specified and as directed for the following :-
(a)One Light Point controlled by One 1-Way Switch 5/6 Amp
(b) One Ceiling Fan / exhaust fan point controlled by one, one way Switch 5/6 Amp and regulator
(C)one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
Description all as per item No 5 but two single core 2.5 Sqmm size copper conductor cable and one single core1.5 Sqmm copper earth wire cable drawn through PVC Casing and Caping medium grade of suitable size and its Accessories as required for One 5 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
M&L Point Wiring with two single core 1100 V grade conforming to IS-694 of 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLS) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including in existing concealed PVC/steel conduit and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on metal flush box, factory made of suitable size with frame and cover plate Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed one Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLS) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light Point/fan/socket point complete all as specified and as directed.
Description all as per item No 10 but two single core 2.5 Sqmm size copper conductor cable and one single core1.5 Sqmm copper earth wire cable drawn through existing concealed PVC/steel conduit and its Accessories as required for One Light Point/fan/socket point complete all as specified and as directed.
Material and Labour for sub main wiring with single core 1100 V grade conforming to IS 694 PVC insulated unsheathed cables two run 6 Sq mm multi stranded copper conductor drawn through and including 25 mm dia non metallic PVC rigid conduit and conduit accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 6 sqmm copper wire earth continuity conductor etc and making good disturbed surfaces to match existing all as specified and directed. Note : Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one run.
Supply and fix in repair Sheet metal enclosures for DBs SPN 4 way 240 V with neutral bus bar 200 Amps double door type with magnetic locking arrangement including removal of old unsv sheet metal enclosure complete all specified and as directed. Make : Legrand/L&T /IndoAsian/ Standard/ ABB/C&S .
Supply and fix in repair Sheet metal enclosures for DBs SPN 8 way 240 V with neutral bus bar 200 Amps double door type with magnetic locking arrangement including removal of old unsv sheet metal enclosure complete all specified and as directed. Make : Legrand/L&T /IndoAsian/ Standard/ ABB/C&S .
Supply and fix in repair Sheet metal enclosures for DBs TPN 4 way 240 V with neutral bus bar 200 Amps double door type with magnetic locking arrangement including removal of old unsv sheet metal enclosure complete all specified and as directed. Make : Legrand/L&T /IndoAsian/ Standard/ ABB/C&S .
S & F MCB FP 415 volts suitable for fixing in MCB DB of capacity 40 / 60 amps, 10 KA, AC, 50Hz, 'C' curve complete all as specified and directed. Make : L&T Cat No BB40400/500/630C or equivalent in Legrand/IndoAsian/ Standard/ ABB/C&S
S & F MCB TP 415 volts suitable for fixing in MCB DB of capacity 40 / 60 amps, 10KA, AC, 50Hz, 'C' curve complete all as specified and directed. Make : L&T Cat No BB30400/500/630C or equivalent in Legrand/IndoAsian/ Standard/ ABB/C&S
S & F MCB DP 230 volts suitable for fixing on MCB DB of capacity 6 to 30 Amps, 10KA, 50 Hz, AC, 'C' curve complete all as specified. Make: L&T Cat No BB20060/100/160/200/250/320C or equivalent in Legrand/IndoAsian/ Standard/ ABB/C&S
S & F MCB SP 6 to 30 Amps 240 volts, 10 KA, AC, 50Hz, 'C' curve for fixing on MCB DB's all as specified. Make: L&T Cat No BB10060/100/160/200/250/320C or equivalent in Legrand/IndoAsian/ Standard/ ABB/C&S
M&L for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SP MCB including removal old unsv one complete all as specified .
S & F wall mounted LED 20 watts, batton type fitting for surface and pendant application, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements and connection from ceiling rose to fitting complete including dismantling the existing unserviceable fitting, complete all as specified and as directed. Make: Philips, Cat No BN021C LED20S PSU CW GR S2 or equivalent Bajaj/Crompton/C&S
S & F wall mounted LED 10 watts, batton type fitting, 230 volts with plastic batten with white acrylic cover etc complete with all accessories internally pre wired and necessary mounting arrangements and connection from ceiling rose to fitting complete including dismantling the existing unserviceable fitting, complete all as specified and as directed. Make: Philips, Cat No BN 021 LED10S-6500 PSU GR S1 or equivalent Bajaj/Crompton/C&S
S & F suspension/wall mounting type 40 Watt LED fitting with flat panel to enhance the, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness LEDs etc complete with all accessories intenally prewired and necessary mounting arrangements, complete incl removal of old unsv fitting all as directed by Engineer-in-charge. Make: Philips, Cat No SP680P LED68S 6500 PSU WH L240 S1 or equivalent Bajaj/Crompton/C&S
S & F Recess mounting flat panel 36 Watt LED fitting 4x1 feet with flat panel to enhance the, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness LEDs etc complete with all accessories intenally prewired and necessary mounting arrangements, complete incl removal of old unsv fitting all as directed by Engineer-in-charge. Make:- Philips, Cat No RC600B LED30S/865 PSU W30L120 IN or equivalent Bajaj/Crompton/C&S
S & F Recess mounting flat panel 36 Watt LED fitting 2x2feet with flat panel to enhance the, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness LEDs etc complete with all accessories intenally prewired and necessary mounting arrangements, complete incl removal of old unsv fitting all as directed by Engineer-in-charge. Make:- Philips Cat No RC380B LED36S-6500 G4 L60 W60 PSU OD or equivalent Bajaj/Crompton/C&S
S & F Recess mounting round flat panel 12 Watt LED fitting with Al die-cast body, finish with drop down diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation.complete with all accessories intenally prewired and necessary mounting arrangements, including connection complete removal of old unsv fitting all as directed by Engineer-in-charge. Make:- Philips Cat No DN393B LED12S-6500PSU WH or equivalent Bajaj/Crompton/C&S
Taking down the existing unserviceable light fitting/High bay light from ceiling of any height, opening the fitting, checking the defect and refixing them after repair including wiring, replacement of unserviceable spare parts comlpete all as specified and directed. Note: Spare parts will be measured and paid in appropriate items.
Supply only Ballast for HPSV/MH,400 Watt complete all as specified. Make: Bajaj Cat No BJOS 400 SV/MH or equivalent Philips/Crompton Greaves
Supply only Ballast for HPSV/MH,150 Watt complete all as specified. Make: Bajaj Cat No BJOS 150 SV/MH or equivalent Philips/Crompton Greaves
Supply only Ballast for HPSV/MH, 70 Watt complete all as specified. Make: Bajaj Cat No BJOS 70 SV/MH or equivalent Philips/Crompton Greaves
Supply only lamp for MH, 400 Watt complete all as specified. Make: Bajaj Cat No 400W MH tubular or equivalent Philips/Crompton Greaves
Supply only lamp for SON, 150 Watt complete all as specified. Make: Bajaj Cat No 150W SV T plus or equivalent Philips/Crompton Greaves
Supply only lamp for SON 70 Watt complete all as specified. Make: Bajaj Cat No. 70W SV T plus or equivalent Philips/Crompton Greaves
Supply only Ignitor HPSV/MH, 70-400 Watt complete all as specified. Make: Bajaj Cat No. BJIGN HPSV/MH-1 or equivalent Philips/Crompton Greaves
Supply only Capacitor 33mfd for HPSV/MH, 400 Watt complete all as specified. Make: Bajaj Cat No. 029516 or equivalent Philips/Crompton Greaves
Supply only Capacitor 20mfd for HPSV/MH, 150 Watt complete all as specified. Make: Bajaj Cat No. 029513 or equivalent Philips/Crompton Greaves
Taking down ceiling fan 1200mm/1400mm sweep from any height and bringing down to floor, dismantling the ceiling fan and overhauling by means of replacing defective ball bearing, bushes, split pins, grease, packing, winding and cleaning externally, re-assembliing the ceiling fan and checking, refixing in its position complete all as specified and directed.
All as per item No.37 but for exhaust fan 150 CFM including replacing of rusted nut and bolts complete all as specified and directed.
All as per item No.37 but for exhaust fan 300/350 CFM including replacing of rusted nut and bolts complete all as specified and directed.
All as per item No.37 but for exhaust fan 2000 CFM including replacing of rusted nut and bolts complete all as specified and directed.
All as per item No.37 but for exhaust fan 9000 CFM including replacing of rusted nut and bolts complete all as specified and directed.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth Lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 and connected to earth testing point all as specified and directed including testing on completion complete all as specified and as directed by Engr-in-Charge including taking down old complete Earthing system complete all as directed by Engineer-in-Charge. Note No.1: The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete
Supply and fix Modular switch one way 6/10A , 1 Module complete all as specified and as directed.
Supply and fix Modular switch one way 16A , 1 Module complete all as specified and as directed.
Supply and fix modular Socket, 6A- 2/3 pin combined 2 Module complete all as specified and as directed.
Supply and fix modular Socket, 6/16A- 2/3 pin combined 2 Module complete all as specified and as directed.
Supply and Fixing modular fan step regulator 120W - 2 module complete all as specified and as directed.
Supply and Fix in repair Ceiling rose 3 terminals, surface bakelite 65 x 50mm complete all specified and as directed.
Taking down geyser of any make, type and any capacity after disconnecting the water and electric line connections from any height, bringing down to floor, dismantling the Geyser and overhauling by means of repair/replacement of the defective spares, descaling of tank and inlet/outlet pipes, checking/testing of all safety devices etc including cleaning externally and internally re-assembling the geyser, fixing in position and testing for satisfactory working etc complete. Note: Replacement of defective spares shall be measured and paid under relevant item separately.
Supply only Neon lamp indicator suitable for Geyser complete all specified and as directed.
Supply only Bottom flange with inlet and outlet pipe (Apparatus plate) suitable for Geyser complete all specified and as directed.
Supply only Thermostat conforming to IS 3017 including setting suitable for Geyser complete all specified and as directed.
Supply only FlexiblePVC connection pipe for cold/hot water suitable for Geyser complete all specified and as directed.
Supply only Heating element 1.5 KW suitable for Geyser complete all specified and as directed.
JR ENTERPRISES
SRI LAKSHMI GANESH ENGINEERING WORKS
VVM CONSTRUCTIONS
CHANDRASEKRAN ENTERPRISES
Vinayaga constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .