Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹24.8 L+₹2.8 L (12.7%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹25.4 L+₹3.4 L (15.4%)Rejected-Finance | L3 | Rejected-Finance Due to L3 | |
| 4 | L4₹25.5 L+₹3.5 L (16.0%)Rejected-Finance | L4 | Rejected-Finance Due to L4 | |
| 5 | L5₹25.5 L+₹3.6 L (16.2%)Rejected-Finance | L5 | Rejected-Finance Due to L5 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
16 Jun 2025, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER JORHAT
PROVISION OF CAR PARKING SHED NEAR ADM BLDG AREA P 17 JOB NO 41SAMINOR17202425 OF 702 ENGR PLANT UNIT AND SPECIAL REPAIR TO ROOF OF BLDG NO P74 JOB NO 41SASRBLDG12202425 AT HQ 41 SUB AREA AT LICHUBARI UNDER GE JORHAT
2025_MES_710484_1
8236/GE/E8
Open Tender
Civil Works
Item Rate
180 days
GE JORHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹44,000
Yes
4 Aug 2025
26 May 2025
17 Jun 2025
26 May 2025
16 Jun 2025
9 Jun 2025
26 May 2025 - 29 May 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level), complete all as directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for, complete all as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
Excavation in trenches, not exc. 1.5 m wide and not exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipe, cable, etc. n exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/ loose soil, complete all as specified and directed.
Returning filling in soft/ loose soil, including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil, complete all as specified and directed.
Material and labour for, hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Materials and labour for, plain cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
Materials and labour for, plain cement concrete (1:3:6) type C1 (using 20 mm graded crushed stone aggregate), complete all as specified and directed.
Material and labour for, brickwork with subclass ‘B’ bricks, old size, straight or curved on plan exc. 6m mean radius built in cement mortar (1:6), complete all as specified and directed.
Supply and fix for, rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed.
Supply and fix for, pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Supply and fix for, pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0kg of cement per sq.metre, complete all as directed.
Material and labour for, providing, cement concrete in roof kerbs, stops, rounded or chamfered on edges in PCC (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) complete all as specified and directed.
Material and labour for, rendering 10 mm thick, cement plaster, in cement mortar (1:3) mixed with water proofing compound as per manufactures instructions, on fair faces of concrete surfaces on roof, finished even and smooth without using extra cement, complete all as specified and directed. (Note: Water proofing compound shall be measured and paid seperately under relevant item).
Supply only liquid water proofing compound complete all as specified.
Supply and laying for 3mm thick (minimum) APP (Atactic Polypropylene Polymer) modified prefabricated five layers, weight not less than 3.5 Kg/ Sqm water proofing membrane, black finished reinforced with non woven polyester matt (weighing not less than 160 gms/ Sqm) with applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm over a coat of bituminous primer @ 0.40 Litre/ Sqm and one coat of bitumen based UV reflective paint with aluminium paint as per manufacturer's instruction over APP membrane. The membrane shall be laid using butane torch and sealing all joints etc., complete all as specified in Para 11.44.5 of SSR Part-I and directed.
Material and labour for, virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM (1:4), complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment as approved laid over and including 50mm thick consolidated sand cushion and joints filled with sand, complete all as specified and directed.
Material and labour for, chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement slurry and pigment in floors over and including 15mm thick screed bed in CM (1:4), complete all as specified and directed.
Material and labour for, 100mm thick plain cement concrete (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in sub base floor, complete all as specified and directed.
Material and labour for, preparation of new or previously untreated surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Material and labour for, point wiring with PVC insulated unsheathed stranded FRLSH copper conductor cable 1100 volts grade, ISI 694 marked of size 1.5 Sqmm drawn in and including PVC casing and capping (Heavy grade), ISI marked) not less than 20mm size with all necessary fittings such as bends, cross, elbow, tees etc. with MS pressed steel cadmium plated terminal box not less than 1.6mm thick for mounting switches, sockets, fan regulator etc. and 3mm thick laminated sheet top cover (ISI marked) including 1.5 Sqmm PVC insulated unsheathed stranded FRLSH copper conductor as continuous earth wire and connected to common earth dolly for one light/ ceiling fan/ exhaust fan controlled by one, one way switch, complete all as specified and directed.
All as per serial item No.27.00 here-in-before for one 3 pin 5 Amps switch socket outlet point on independent board.
Supply and fix for, switch piano, flush type single pole, one way 5/6 Amp 240 volts, complete all as specified and directed.
Supply and fix for, switch socket combination 2 in 1, 6 Amps, 240 volts flush type, complete all as specified and directed.
Supply and fix for, ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, complete all as specified and directed.
Supply and fix for, sheet metal enclosure for DB's when MCBs to be used, SPN 240 volts, 8 ways 200 Amps rated bus bar, metal double door type IP-43, complete all as specified and directed.
Supply, fixing, testing and commissioning for, 6 to 32 Amp, SP 240 volts 10KA 'C' curve miniature circuit breaker (MCB), complete all as specified and directed.
Supply, fixing, testing and commissioning for, 6 to 32 Amps, SPN 240 volts 10KA 'C' curve miniature circuit breaker (MCB), complete all as specified and directed.
Supply and fix for, LED tube light fitting 1 x 20W (+/-5%) 220 volt, AC with extruded strip in thermally conductive material and extruded housing in optically efficient material milky white with system lumen efficacy> 120 lumen per watt minimum system 2300 - 2400 and make LED of chip: Osram, Cree, Nichia, Seoul, Sumsung. Integrated electronic driver, SMD based LED constant current supply with double sided connection to avoid short circuit and surge protection greater than 2.5 KV, IP 20 protection and CRI>80, power factor> 0.95, THD less than 15%, correlated colour temperature (CCT) of 6500K, operating voltage of 140 to 270 volt, frequency of 50Hz, burning hours 50000 hours with comprises of CRCA pre-coated metal housing all as per Cat No.CG-CCS-100-20-65-HL2-DP-NWH of make Crompton or equivalent model of make as specified in PS, complete all as specified and directed.
Supply and fix, LED street light fitting 25 Watt 230 Volt AC outdoor type made of pressure die cast aluminium housing with toughened glass cover, IP66 protection, high power LEDs with secondary lenses and system efficay should be minimum 110 lumen per watt and LM79 all as per Cat No.CG-TRP-400-25-57-SL-LM-NSR of make Crompton or equivalent model of make as specified in PS, report should be provided from NABL accredited lab. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection and external 10KV surge protection inside luminaire housing for trouble free service life. THD shall be <10%, power factor>0.95, CCT5700K and Brand name should be embossed/ engrave on the LED fitting traceability till life. Warranty should be 2 years and warranty certificate should be provided on OEM letterhead at the time of delivery, complete all as specified and directed.
Supply, laying, testing and commissioning of XLPE insulated, screened, PVC badded, galvanised steel strip or wire, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core, complete all as specified and directed.
Material and labour for, sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. (NOTE : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for).
Material and labour for, sub class 'B' brick, well burnt, old size, flat, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed.
Supply and fix for, GI tubing 40mm bore, light grade, laid in trenches for cable protection under the road/ path/ pole, complete all as specified and directed.
Material and labour for, earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.50 metre below normal ground level connected to galvanised steel earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete earth pit in PCC (1:3:6) type C1, 50mm thick pre-cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) cover slab (Reinforced with 8mm dia TMT bar @15cm centre to centre bothways and suitable handle made of 10mm dia), provision of funnel, wire mesh, 20mm bore galvanised steel tubing (medium grade) for watering, charcoal or coke and salt in alternate layers of 15cm (compacted thickness), 15mm bore galvanised steel tubing (light grade) for protection of earth lead connection, necessary excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No.3 of SSR Part-I (2009) including testing on completion. (Note: GI earth wire and protection pipe upto 7.5metres shall be deemed to be included in the unit quoted rate).
M/S PAUL CONSTRUCTION (BID ID -3324325)
SHRI RAJEN PASWAN (BID ID -3323855)
KAY CEE CO. INDIA (BID ID -3321554)
A M CHOUDHURY AND CO (BID ID -3323749)
Chief Builders &Consultants (BID ID -3325085)
SUBHAS CONSTRUCTIONS (BID ID -3324082)
M/S KESHAVECONSTRUCTIONS (BID ID -3322126)
M/S KRISHNA CONSTRUCTION CO (BID ID -3321538)
A K DUTTA CHOWDHURY AND CO (BID ID -3324201)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .