Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | ₹7.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹7.4 LRejected-Finance S 19 126 VARUNA BRIDGE VARANASI | ₹7.4 L | L2 | Rejected-Finance Rejected Being Higher rates |
| 3 | L3₹7.8 LRejected-Finance 4 4 VIKAS NAGAR LUCKNOW U P | LUCKNOW | LUCKNOW | UTTAR PRADESH | ₹7.8 L | L3 | Rejected-Finance Rejected Being Higher rates |
Tender Value
₹13.7 L
EMD Value
₹1.4 L
Closing Date
24 Feb 2026, 12:00 pmClosed
Executive Engineer PD PWD Lucknow
Office of the Executive Engineer PD PWD Lucknow
Road Signage work at different roads in Daliganj Puraniya and various roads of Aliganj area under jurisdiction of AE-I in Lucknow city
2026_CEUCZ_1117192_2
986/E-Tender/2025-26 Dt. 10.02.2026
Open Tender
Road Works
90 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹856
₹1.4 L
Office of the Executive Engineer PD PWD Lucknow
14 May 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
19 Feb 2026
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes.as per SOR Chap-26 Item No.2
Supply & fixing of Linear Delineator System (LDS) panels made of Micro Prismatic Retro Reflective sheeting type XI duly laminated on thin aluminium foil to a unique corrugated shape to provide Retro Reflection across wide range of observations and external angles. Eatch LDS panel should be of nominal length of 33 inch and each ridge shall be approximately 0.34 inch high. Each LDS panel is to be firmly fixed on existing concrete/brick work with 16 Nos fastner/ screw . IRC:79-2019 as per SOR Ch-26 SI No.-9
Flexible Median Marker (FMM) should be used for improving median visibility during dark hours. , Use of Median Marker provides safety against collision happening with medians during night time , or severe weather. Flexible Median Markers shall be provided with fluorescent yellow colour retro-reflective sheeting Type XI as per IRC:67 upto date. Flexible Median Marker shall be of tough, high impact resistant, injection-molded, thermoplastic body with property of flexibility to provide high durability 'and U shape structure having rebound / bounce back property. the sheeting shall be of Type XI conforming to IRC:67 upto date and it should be on both .the faces whereby providing maximum reflectivity at longer distances with adequate durability. The logo of the manufacturer shall be embossed on either side of the body during the injection molding process. FMM shall be fixed by a combination of epoxy adhesive and grouting/ drilling on concrete medians or properly constructed solid medians. Height: The marker height shall be a minimum of 180 mm. width 120 mm & Body Thickness: 6.5 mm. the shanks shall not be less than 20 mm and depth shall not be less than 30 rnm Reflective Area: Shall not be less than 90 cm square . Proof of the same Report shall be uploaded which quoting tender. The body of FMM shall bounce back to its original position of after 750 number of hits using pendulum of 1.8 kg conforming 40 ASTM D256 adhesion between the body and outer casing body of FMM shall with stand 50 kg f Tensile loads conforming to ASTM D638 method. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge. as per SOR Ch-26 SI No.-6
Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply and fixing of raised pavement marker with Made of Plastic body of RPM/ Road Stud shall be moulded from ASA (Acrylic Styrene Acrylonitrite) or HIPS (High-Impact Polystyrene) or Acrylonitrile Butadien Styrene (ABS) or Any other suitable material approved by the Engineer. The Marker shall support a load of 13,635 kg tested in accordance with ASTM D4280.The Reflective panels shall consist of number of lenses contatning single or dual prismatic cubes capable of providing total internal reflection of the light entring the lens face. Lenses shall be moulded of methyl methecrylate conforming to ASTM D788 or equivalent. The slop or retro-reflecting surface shall preferably be 35+/-5 degree to base and the area of each retro -reflecting surface shall not be less than 13.00 sq.cm. marker height shall not be less than 10 mm and shall not exceed 20 mm & Width shall not exceed 130 mm. The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name , trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the Engineer . In addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. In case the markers are displaced , damaged , get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer , at his own cost. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge.RPM (with shank) As Per SOR ch-26 SI no.5
Road DelinatorDelineator: Supply & Fixing of M S Delineator made of Mild steel with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron for protection against corrosion. The surface should be conceated so that there should not be any exposed surface without powder coating. Alternatively, these metal guide poles can be concealed with thermoplastic body. The posts shall have Ian ellipsoidal or circular design with the height of the pole shall be 800 to 900 mm above the ground with about 200 to 300 mm base which can be anchored onto the ground. Mild steeI Guide Poles shall conform to Type XI sheeting specifications as per IRC:67 and ASTM D4956 which would ensure to obtainI clear visibility of the road alignment during night time. The Retro reflective sheeting shall be tested for A certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory / Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge. as per SOR Ch-26 SI No.-1
The Solar studs shall be made of aluminium alloy and poly carbonate material which shall be absolutely weather resistant and strong enough to support a load of 13.635 kg tested in accordance with ASTM D4280. Its colour may be white, red, yellow, green or blue or combination as directed by the Engineer. Its water resistance shall meet the requirements of IP 65 in accordance with IS: 12063 : 1987 category 2 for protection against water ingress. The dimensions of solar studs shall not be less than 100 mm x 100 mm x 10 mm. It shall have super bright LEDs so as to provide long visibility from a distance of more than 800m. Its flashing rate shall not be less than 1 Hz. Its shaluld be able to give the prescribed performance in the temperature range of - 40oC to +55oC. Its life shall be not less than 3 Years. The rate shall include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-charge. as per SOR Ch-26 SI No.-16
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
BOQ_2075695.xls
BOQ • 0.25 MB
T1.pdf
Tender Documents • 2.12 MB
Download all tender documents and submit your bid