RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. High Mast Pole With LED Flood Lighting System ( 145 pieces ) ( Under PAC ) Make havels Model havellshb90w 1/10 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Highmast with LED Luminaires contains High mast pole
RequiredLED flood light luminaire
RequiredDistribution box
RequiredMCB
RequiredPower cable
RequiredWiring
RequiredEarthing road and wire
RequiredMounting brackets and other suitable accessories as applicable Yes * Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt.
Requiredrules and regulations as applicable No No Onsite warranty (in Years) 2 2 POLE Tubular steel poles shall be conforming to IS 2713/80(Part-1& 2) with amdt No-1 latest * ISI Marked No No ISI Marekd if "Yes" BIS License Number (CM/L Number) - Must declare (If No write NA) NA * Length of Tubular steel poles (in Metre) 11 11 Type of steel poles Swaged (SP) Swaged (SP) Designation of Tubular steel poles as per table 2 of IS 2713/80 Part-2 with amdt No 1 410SP-4 410SP-4 Earthing arrangement as per Cl.14.1 of IS:2713:1980 Part 1 latest Yes Yes 2/10 Coating on the tubular steel poles (for entire length) Bitumen coated as per clause 13.1 of IS:2713 part 1/1980 Bitumen coated as per clause 13.1 of IS:2713 part 1/1980 Grade of steel tube
Requiredas per IS:1161/1998 Yst 310 Yst 310 Availability of Type Test Reports of the product from Central Govt/NABL/ILAC accredited Lab showing compliance to the specification (as per IS:2713:1980 Part 1
RequiredPart 2 latest). Yes * LED FLOOD LIGHT LUMINAIRE No. of Luminaires per pole 6 Nos./pole 6 Nos./pole LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * Types of LED Luminaire as per the IS: 16107(Part-2 Sec.-1)/2012 Type B * Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 * LED Rating/System Wattage/Rated Power 100W 100W Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 IP66 Mounting brackets (included) Adjustable * Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V Automatic Higher Cut off voltage above 300 volt Yes * 3/10 Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) ≥85 * Total Harmonics Distortion (in %age) ≤ 10 * The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes * LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 5000 K 5000 K Working life for LED (Minimum 50
Required000 burning hours as per LM-80 report) Yes * Colour Rendering Index(CRI) ≥70 * Beam Angle ≥120 * Optic lense materal (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense Poly carbonate lense Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Junction temperature < 85 degC * Operating temperature range -20 deg C to +50 deg C
Required-20 deg C to +50 deg C
RequiredOperating Humidity Range 10 % to 95% RH * Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 Yes * 4/10 KV for one minute between supply terminals and body of the unit) Insulation resistance between earth and current carrying part >100 M ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV >/=4KV The luminaire shall be protected against surges and transients of >/=10KV (External) No No The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant epoxy powder coated Yes * All fastners must be of stainless steel Yes * The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes * Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
Requiredwater
Requiredinsects etc.
RequiredYes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * 5/10 Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear per luminaire (power supplies) (in Numbers) 3 3 Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase
RequiredNeutral and Earth) Yes * Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with supply of material) 100 cm 100 cm Light Source SMD LED Chip as per LM 80/IS16106 * Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed * Manufacturer’s name
Requiredmodel number
Requiredserial number Yes * Date of manufacture (month-year)
Requiredand lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED Yes * 6/10 luminaire unit LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND
RequiredOSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND
RequiredSystem must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output
Requiredpower
RequiredPF
RequiredCurrent in Amps
RequiredCRI & CCT etc.
Required) Yes * LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being used in the luminaire) Yes * Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * DC or AC supplied Yes * 7/10 electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 as applicable on the date Yes * ACCESSORIES - G I Pipe G.I. Pipe (ISI Marked) for earthing with all accessories per pole shall supplied No No G.I. Pipe length (in mm) NA NA G.I. Pipe dia 20 mm 20 mm ACCESSORIES - G I Wire ISI marked G.I. wire shall be supplied per pole for earthing No No G.I. wire dia (in mm) NA NA G.I. Wire length (in m) NA NA ACCESSORIES - Power Cable PVC Insulated
Requiredarmoured power cable (ISI marked to IS:1554 Part 1) shall be supply per pole No No No. of core NA NA Cross sectional area of cable (in Sq.mm) NA NA Conductor material NA NA Cable category NA NA Length (in mtrs.
Required) NA NA ACCESSORIES - Wiring PVC insulated wiring cable (IS Marked to IS:694) shall be supply per pole No No No. of core NA 2
RequiredNA Cross sectional area of cable (in Sq.mm) NA 1.5
RequiredNA Conductor material (for wiring) NA NA Cable category (for wiring) NA NA 8/10 Cable length (in mtrs.
Required) NA NA ACCESSORIES - MCB Distribution Board with Switches & Terminals and ISI marked MCB per pole shall be supply with lighting system No No Distribution board for fixing MCB with enclosure protection NA NA Distribution Board per pole for fixing MCB with enclosure protection IP43 and above NA NA MCB - Rated current (in Ampere) 1.0 A 1.0 A No. of pole na na Rated Voltage NA NA Bracket for each pole : Mounting arrachement including suitable bracket for fixing the Luminaires with each pole. Bracket material shall be MS. Galvanised min. Mass of Zinc coating 360 Gms. sq. Mtr.
RequiredNA NA CERTIFICATIONS Marking: All the products shall have marking details as per relevant BIS standard Yes * Seller shall furish all the test reports and certificates as per the technical specification to the purchase auhtority on demand Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents