Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.4 L+₹1.2 L (4.60%)Rejected-AOC SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹26.8 L+₹1.6 L (6.16%)Rejected-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹36.7 L+₹11.5 L (45.7%)Rejected-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-AOC NOT LOWEST |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
29 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col AK Tripathi CWE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
REPAIR / MAINTENANCE OF HT SWITCH GEARS, HT CABLES, AND OTHER CONNECTED WORKS UNDER GE (NORTH) BANGALORE
2024_MES_644791_1
86251/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE ARMY BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (NORTH) BANGALORE
₹57,000
Yes
8 May 2024
1 Mar 2024
5 Apr 2024
1 Mar 2024
29 Mar 2024
15 Mar 2024
1 Mar 2024 - 8 Mar 2024
Amount
Taking down defective transformers of any size and capacity incl disconnecting elect connection LT/HT side from two pole structure, from platform or from indoor sub stn transporting it to the workshop for repairs testing/commissioning and reinstallation after repairs as and where directed including making elect connection on HT/LT side. Note: Transportation charge both to & fro is inclued in quoted rate.
Strip opening of transformer 315 to 500 KVA, 11 KV/440 volts indoor/outdoor of any make/type after unscrewing nuts/bolts, washers and taking down other connected accessories, such as temp guage/breather, conservator tank for rewinding of HT/LT coils (Payment of repairs replacement of parts, rewinding of coils and filtration of oil will be measured and paid for separately under relevant item of schedule.
All as per srl item No 2 hereinbefore but of capacity 200 KVA to 250 KVA
Supply and replacement of HT coils made out of super enameled copper winding wire for transformer capacity 100 KVA to 500 KVA. Note Mode of rewinding/guage of winding wire will be maintained as per the manufacturers design.
Supply and replacement of LT coil of copper strip duly insulated/cotton covered/varnished as per the standard design.
Reconditioning of LT coils by removing old insulation, covering with super enameled varnish, cotton tape etc.
Filtration & Dehydration of transformers oil for transformers, through on line filtration equipment to with stand min dielectric strength 40 KV for 1 min at 2.5 mm gap and flash at 60 KV without disturbing/switching off system all as specified and as directed.
Supply and topping up of fresh transformer oil suitable for 11 KV system for transformer having 45KV of minimum dielectric strength all as specified and as directed.
Preparing the surface of the transformers for painting by cleaning thoroughly the surface for removing dirt, grease, oil, scales etc and spray painting with a coat of synthetic enamel paint of suitable/specified colour as directed incl painting/writing the SM and MES No on the transformer with white paint all as specified and as directed of the following capacities:- (a) Transformer 250 to 500 KVA
(b) Transformer up to 200 KVA
Material and Labour for Earthing with earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connected to and incl earthing of GI strip 32 x 6mm by means of bolts, nuts, check nuts and washers made of GI and protected by light grade 40mm dia GI pipe connected to main switch board or control board and GI pipe light grade 20mm dia for watering and incl funnel, wire mesh, precast RCC pit cover 40mm thick in cement concrete 1:2:4, type B1 with 8mm dia MS reinforcement at 10cm centre to centre bothways and PCC chamber pit with PCC 1:3:6 type C1 incl excavation and earth work, disposal of surplus soil to a distance not exc 50m all as specified and shown on plate No 5 of SSR Part I 2009 including taking out old unserviceable earthing. Note: - (i) Earthing strip and protection pipe to a length of 7.5 m is deemed to be included in the rate of this item. (ii) The unit rate deemed to include taking out old earthing.
Supply only HT bushes suitable for 100 KVA to 200 KVA transformer of Make :- BHEL/JAYSHREE
Supply only HT bushes suitable for 250 KVA to 500KVA transformer of Make :- BHEL/JAYSHREE
Supply only LT bushes suitable for 100 KVA to 200 KVA transformer of Make :- BHEL/JAYSHREE
Supply only LT bushes suitable for 250 KVA to 500 KVA transformer of Make :- BHEL/JAYSHREE
Dismantling the unserviceable indoor / out door transformer of capacity 100 KVA to 200KVA from bed by disconnecting incoming/outgoing HT/ LT side connections, removing the earth strip connections from transformer body and neutral point, and cable connections etc from structure / sub stations and transportation to workshop for winding with the help of chin pulling/ Crane , draining the total oil, inspecting thoroughly for the defective High voltage/Low voltage windings, carry out the testing of total active parts. Over hauling the core and balance coils flushing with hot oil for removal of copper particles, sludge and any other unwanted particles. Cutting and removing of burnt transformer winding HV/LV and providing new winding at both HV/LV and replacing with copper conductor of same size and gauge to achieve transformer rated capacity and new insulation materials such as FRP studs, spares, runners, gaskets including brazing etc,resetting/fixing the core assembly and with pry/sec brazing as required and all necessary connections. Drying out of core coil assembly , cleaning of inside and outside of the tank by sand blasting process including replacing of tank gasket .Providing insulation for over all winding and re-assembly connections with provisions of new gasket and insulation materials putting back the cover tightening the fixture, fixing the bushes, bolts and nuts etc., Painting of the transformer including transportation from workshop to sub station including testing & commissioning complete all as specified & as directed. Note: Transportation charge both to & fro is included in quoted rate. 2. Crane charges are also included in quoted rate
Dismantling the unserviceable indoor / outdoor transformer of capacity 250 KVA to 400 KVA from bed by disconnecting incoming/outgoing HT/ LT side connections, removing the earth strip connections from transformer body and neutral point, and cable connections etc from structure / sub stations and transportation workshop for winding.with the help of chin pulling/ Crane , draining the total oil, inspecting thoroughly for the defective High voltage/Low voltage windings, carry out the testing of total active parts. Over hauling the core and balance coils flushing with hot oil for removal of copper particles, sludge and any other unwanted particles. Cutting and removing of burnt transformer winding HV/LV and providing new winding at both HV/LV and replacing with copper conductor of same size and gauge to achieve transformer rated capacity and new insulation materials such as FRP studs, spares, runners, gaskets including brazing etc,resetting/fixing the core assembly and with pry/sec brazing as required and all necessary connections. Drying out of core coil assembly , cleaning of inside and outside of the tank by sand blasting process including replacing of tank gasket .Providing insulation for over all winding and re-assembly connections with provisions of new gasket and insulation materials putting back the cover tightening the fixture, fixing the bushes, bolts and nuts etc., Painting of the transformer including transportation from workshop to sub station including testing & commissioning complete all as specified & as directed.
Material and Labour for Breather assembly as per existing sizes all as specified and as directed. Note : Silica gel required for breather will be measured & paid separately
Supply and fixing of Silica gel.
Supply and fixing in replacement Aluminium strip of sizes 25x3mm fixed on walls/poles/ shafts/pipes, etc all as specified & as directed including taking down existing strip
Supply and fixing replacement GI strip of sizes 32 x 6 mm fixed on walls/poles/ shafts/pipes, etc all as specified & as directed including taking down existing strip
Supply and fixing in replacement of ACSR (Aluminium conductor steel reinforced) conductor of any size of on poles including binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed.
Supply and fixing in replacement of outdoor type triple pole switch air brake (gange operated) each pole consisting of galvanized steel base HT insulators as per BSS/ISS , non ferrous knife and spring loaded contact , arcing horn mechanically operated , horizontal/v erticaltype mounted on insulator and steel frame complete , current rating up to 400 Amps
Supply and fixing in replacement of lightening arrestor metal oxid type complete with all fittings transmission class discharge capacity 65 Kilo Amps suitable for 11000 volts grade complete all specified and as directed.
Supply and fixing in replacement of expulsion fuse unit 11 KV drop out up to 25 Amps complete all specified and as directed.
Material and Labour for replacement of disc type insulator porcelain vitreous 145 mm high and 255 mm dia ball and socket type white or brown single disc assembly for tension clamps for conductors working pressure 11000 volts complete all specified and as directed.
Material and Labour for in replacement of iron work of any type incl cross arms ,supports , bracing MS clamps etc made out of MS channel/angle iron/ flat iron/ round section of any size and bolts, nuts and washers incl painting with two coats of aluminium paint over a coat of red oxide complete all specified and as directed.
Material and Labour for servicing of existing GOD with replacement with GI nuts bolts , washers and lugs etc as per site requirement including necessary greasing and cleaning with petroleum jelly all as specified and directed by Engr-in -charge
Loose filling of coarse stone aggregate obtained from sl item No 28 at sub stations of various locations complete all as specfied and as directed.
Removing coarse stone aggregate and supply and spread new coarse aggregate by loose filling of size 40mm grade inside the area of sub stations at various locations complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out in hard/dense soil all specified and as directed.
Returning, filling in of exceeding soil including spreading leveling watering and well ramming in layers not exceeding 25 cm all specified and as directed.
Removing of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all specified and as directed.
Material and Labour for Filling approved river sand in trenches for sand cushion for laying of cable etc all as specified and as directed. Note : The punned thickness only shall be measured
Material and Labour for Unreinforced precast concrete cable cover HV type size 300mmx 180mm x 40mm, laid flat across the cable length all as per specification and directed
Boring of holes under road, pavement, hard standing by trenchless using ultra sounding technique and necessary machine including HDPE pipe of 100 mm dia bore suitable for 0.4 mpa working pressure all specified and as directed.
Supply and Fixing of GI tubing light grade 80 mm bore with all fitting laid in trenches/walls/Roads/pole for cable protection all specified and as directed.
Disconnecting faulty 11 KV HT cables of any size and any length from both ends Hiring of cable fault detector machine to detect exact position of fault including pressure test for removing the moisture in XLPE /PVC HT cable, 11000 Volts grade heavy duty aluminium conductor of any size and any length , removal of Fault, Re-connections and testing of cables after removal of fault including excavation, returung filling, Removal, relaying of cable protection cover etc complete as specified and directed. Note : (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown alongwith fault locating machine and manpower. In case the rep or contractor shall not come to the site of breakdown and not to start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues. (c) Quoted rate is inclusive of hiring charge of detecter machine.
Supplying, laying, jointing, testing and commissioning in replacement HT underground electric power cable Crossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts earthed cross sectional area 185 Sqmm , 3 core ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles/wall etc. complete all as specified and directed.
All as per item No 38 here-in before but cross sectional area 150 Sqmm , 3 core complete all as specified and directed.
All as per item No 38 here-in before but cross sectional area 120 Sqmm , 3 core complete all as specified and directed.
All as per item No 38 here-in before but cross sectional area 95 Sqmm , 3 core complete all as specified and directed.
Supply and Fixing of Cable jointing kit for 11 KV (earthed ) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 sqmm, 3 core incl cutting the unserviceable portion and jointing cable in RYB phase sequence and testing complete all as specified and directed
All as per item No 42 herein before but size of 120 Sqmm to 185 Sqmm all as specified and as directed.
Supply and Fixing of Cable jointing kit for 11 KV (earthed ) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 sqmm, 3 core including cutting the unserviceable portion and jointing cable in RYB phase sequence and testing complete all as specified and directed.
All as per item No 44 herein before but size of 120 Sqmm to 185 Sqmm complete all as specified and directed.
All as per item No 44 herein before but size of 240 Sqmm to 300 Sqmm complete all as specified and directed.
Supply and Fixing of Cable jointing kit for 11 KV (earthed ) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 sqmm, 3 core incl cutting the unserviceable portion and jointing cable in RYB phase sequence and testing complete as specified and directed
All as per item No 47 herein before but size of 120 Sqmm to 185 Sqmm complete as specified and directed
Material and Labour for Danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M.S clamps , bolts and nuts of approved size, for HT, 25mmX20mmX 1.6mm size incl taking down old one complete all as specified and directed.
Supply and Fixing of cable route markers made out of PCC block (1:3:6) type C-1 using 20 mm graded stone aggregate size (bottom 400mmx 100 mm thick) + Top-300x100mm thick+height-1200mm(60 cm burried in ground DANGER /11 KV UG cable MES embossed on route marker including excavation and earth work and painting the yellow colour above the ground and write the black colour complete all as specified and directed
Material and Labour for Preparation of old painted surface and painting wtwo pole structure of HT steel tubular pole 11 mtr long from bottom to top incl all iron structure with aluminium paint and painting to bottom up to 1.5 mtr height from top of PCC coping with synthetic enamel paint one coats in Red /yellow/blue alternate strip incl numbering in 8 cm height of number with black paint duly approved by Engineer-in-charge and complete all as specified and as directed.
Material and Labour for Preparation of old painted surface and painting 4 pole/two pole structure of HT steel tubular pole 11 mtr long from bottom to top incl all iron structure with aluminium paint and painting to bottom up to 1.5 mtr height from top of PCC coping with synthetic enamel paint one coats in Red /yellow/blue alternate strip incl numbering in 8 cm height of number with black paint duly approved by Engineer-in-charge and complete all as specified and directed
Supply and Fixing of MS framed work as in doors or gates of angle or other section etc to be prepared for hanging and including either hooks and hinges etc with end of bars shouldered and /or riveted and welded complete confirms to Fe 290 Gde - E - 165 and painted with synthetic enamel paint all as specified and directed .
Supply and Fixing of Mild steel screw bolts (Machine made), 11 to 15 mm neck dia with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm but n exc 10 cm long complete all as specified and directed.
Material and Labour for Painting of existing outdoor substation fencing (XPM) at site ( prior to painting to fencing will be fully cleaned/scrubbed removing of rust deposition/dirt/oil paint etc) with super enameled paint duly approved from Engineer-in-Charge
Material and Labour for replacement of tap changing device for 100 KVA to 500 KVA transformers.
Supply and replacement of Master Trip Relay suitable for 1 Amp or 5 Amp CT secondary for 11 KV system suitable for existing VCB panel complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Power Pack with 15 minutes backup suitable for 11 KV VCB complete all as specified and directed by Engineer-in-Charge.
Servicing and overhauling of 11 KV Vacuum Circuit Breaker of any rating and any make by carefully drawing out the breaker from panel, degreasing and cleaning all moving parts, checking the condition of vacuum interrupters, male & female contacts, flexible connection, spring charging motor, gear assembly, tripping coil, timer, control wiring, operations of breaker both electrically and mechanically, inspecting all bolts, nuts, pins and collar pins etc and replacing the defective parts if any, applying grease to all moving parts, gears and trolley and petroleum jelly to male & female contacts and re-assembling, refixing and testing for smooth functioning of breaker complete all as specified and directed by Engineer-in-Charge. Note: The spare parts required shall be measured and paid separately as "Supply Only" and the labour part shall deemed to be included in the quoted rate.
Supply only in replacement of Vacuum Interrupter suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB).
Supply only in replacement of female contact suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB).
Calibration of IDMT relay by conducting primary injection / secondary injection tests, checking of current transformer, rectification of defects in control wiring, necessary adjustment/setting of plug and time multiplier settings of the relay for proper tripping of circuit breakers through CTs, relays and tripping coils complete all as specified and as directed. Note: The contractor shall arrange all necessary testing kits, testing equipments, tools etc and shall also prepare necessary test reports and submit to the department before claiming payment in RAR / FB. Hiring charges of testing kit and equipment is deemed to be included in the quoted rate. Testing, tuning and setting of relay shall be carried out in the presence of Engineer-in-Charge.
Supply only in replacement of flexible copper strip connection suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB).
Supply only in replacement of spring charging motor suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB).
Supply only in replacement of charging gear assembly (big & small both) suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB).
Supply only in replacement of Trip & Close coil suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB) for 24 V DC control voltage.
Supply only in replacement of push to trip / push to close buttons with spring suitable for existing make and model of 11 KV Vacuum Circuit Breaker (VCB) for 24 V DC control voltage.
Supply only in replacement of LED indication lamps of any colour as per site requirement suitable 11 KV Vacuum Circuit Breaker (VCB) Panel.
Aavani BUILDERS AND CONTRACTORS
Rama Electricals
NAVREET CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .