Tender Value
₹2.0 Cr
EMD Value
₹4 L
Closing Date
7 Nov 2024, 4:00 pmClosed
Executive Engineer, PHD, PWD, Puducherry
Office of the Executive Engineer, Public Health Division, 1 Subbiah Salai, Uppalam, PWD, Puducherry.
Rejuvenating the existing 17 MLD Capacity Sewage Treatment Plant At Kanaganeri,Rediarpalayam, Puducherry Under EPC Mode.
2024_PWDC2_16683_1
16/PHD/2024-25 EPC Mode
Open Tender
Civil Works - Water Works
Item Rate
120 days
Uppalam
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,575
₹4 L
Puducherry
7 Mar 2025
9 Oct 2024
8 Nov 2024
9 Oct 2024
7 Nov 2024
9 Oct 2024
21 Oct 2024
Amount
E. Supply, installation of new set of DO sensors (HACH or E&H) at the SBR tanks and connect with the system with the already available network and commissioning the same at site – 2 Sets F. Supply, installation of new set of Level sensors at the SBR tanks and connect with the system with the already available network and commissioning the same at site – 2 Sets G. Servicing of SBR SCADA system and put the same in operation – 1 No H. Bringing the required MLSS from outside and commission the SBR system to meet the outlet parameters as required for disposal – 2 Nos
Attending following repair and service in Mechanical Coarse Screen as detailed below:- A. Servicing the existing coarse screens with the authorized service person and put the same in good operation condition – 2 Nos B. Repairing the existing Inlet Gates and put the same in good operation condition – 1 No C. Supply and installation of new conveyor belt to suit the existing conveyor system and put the same in operation condition – 1 No
Attending following repair and service inMain Pumping Station as detailed below:- A. Removing the existing submersible pumps from the MPS, servicing the same to put the pump in operating condition and installation at the same location – 2 Nos B. Removing the existing control panels, supply & installation of new set of VFD control panels suitable for 40 HP submersible pumps, input connections with the existing cables complete work as per the site requirement – 6 Nos C. Supply and installation of Junction box with pump control devices for connecting with pump and control panel including cables –6Sets.
Attending following repair and service inMechanical Fine Screen as detailed below:- A. Servicing the existing fine screens with the authorized service person and put the same in good operation condition – 2 Nos B. Repairing the existing inlet Gates and put the same in good operation condition – 3 Nos C. Supply and installation of new conveyor belt to suit the existing conveyor system and put the same in operating condition – 1 No D. Supply and installation of new Local push button -3 Nos
Attending following repair and service inGrit Mechanism as detailed below:- A. Removing the sludge & grit at the Grit Mechanism tank and cleaning the same at site- 2 Nos B. Repair / Service the grit mechanism and put the same in operating condition at site including if any spare parts requirement- 2 Nos
Attending following repair and service in Chlorination System as detailed below:- A. Testing of existing chlorine gas cylinders and filling of chlorine gas including transport expenses - 3 Nos B. Replacing the existing copper tubes with new copper tube and installation of the same – 2 Nos C. Supply and installation of new gas leak sensor for sensing the chlorine gas leak- 2 Nos D. Servicing of the existing EOT system and put the same in good operating system at site – 1 No E. Service/ Repair of the full chlorination system, replacement of spare parts if anything required and put the same in good operation condition- 2 Nos F. Repair / Service of existing Booster pump and put the same in operating condition – 1 No G. Repair / Service of existing Blower and put the same in operating condition-2 Nos H. Repair of the existing electrical control panel including replacement of missing components and put the same in operating condition – 1 No zzzzzzzzzz F. D. Servicing of the existing EOT system and put the same in good operating system at site – 1 No A. Service/ Repair of the full chlorination system, replacement of spare parts if anything required and put the same in good operation condition- 2 Nos B. Repair / Service of existing Booster pump and put the same in operating condition – 1 No C. Repair / Service of existing Blower and put the same in operating condition-2 Nos D. Repair of the existing electrical control panel including replacement of missing components and put the same in operating condition – 1 No
Attending following repair and service inTreated Water Pump as detailed below:- A. Removing the existing control panels, supply & installation of new set of VFD control panels suitable for the submersible pumps includingpump protection devices, input connections with the existing cables complete work as per the site requirement – 2 Nos
Attending following repair and service inTreated Water Pump as detailed below:- A. Supply and installation of condensers for the capacitor panel 250 KVAR– 1 No
Eco Protection Engineers Private Limited (BID ID -52684)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .