Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹98.6 L
EMD Value
₹2.0 L
Closing Date
28 Mar 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
TRD
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar work means - "Execution of 25kV/2x25kV Electrification work involving TSS/SP/SSP work OR Execution of 25 kV/2x25 kV TSS work OR Execution of 25kV/2x25kV Switching post (SSP/SP) Work OR Execution of 25kV/2x25kV TSS modification work OR Execution of 25kV/2x25kV SP/SSP modification work OR Execution of 25kV/2x25kV TSS augmentation work OR Execution of 25kV/2x25kV SP/SSP augmentation work OR Execution of 25kV/2x25kV PSI(i.e. TSS/SP/SSP) operation or maintenance OR Execution of 25kV/2x25kV PSI (i.e. TSS/SP/SSP) AMC work OR Execution of 25kV/2x25kV PSI replacement work i.e. CB/BM/CT/PT/LA/Control & Relay Panel OR Execution of 33kV or higher voltage Substation/Switch Yard OR Modification work of 33kV or higher voltage Power supply equipment OR Up gradation work of 33kV or higher voltage power supply equipment OR Overhauling/repair work of 33kV or higher voltage Power Supply equipment."
The Tenderer/Firm must have valid Electrical Contractor License (ECL) and copy of license must be uploaded in IREPS site during bid. In case Tenderers submitted with ECL issued in the name other Firms/Tenderers will be summarily rejected. In case the ECL is not valid on the date of opening of tender, details of renewal should be submitted.
9 conditions · 6 needing a document upload
Goods & Services Tax (GST) registration certificate copy should be attached.
In case of Sole Proprietorship Concern firm has to submit Affidavit certifying the sole Proprietorship of the firm. This affidavit shall be notarized. Or In case of a Partnership Firm, Firm has to submit (a) Notary certified copy of the Partnership Deed. (b) A copy of power of Attorney firm has to submit (duly registered as per prevailing Law) in favour of an individual to tender for the work, sign the agreement etc., and create liability against the Firm. Or In case Tenderer is a Company registered under Companies Act-2013. The tenderer shall submit: (a)The copies of MOA (Memorandum of Association)/AOA (Articles of Association) of the company. (b) A copy of Certificate of Incorporation. (c) A copy of authorization/ Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of company and create liability against the company. Or In case Tenderer is LLP (Limited Liability Partnership); If the tender is submitted on behalf of a LLP registered under LLP Act-2008, the Tenderer shall submit along with tender: (a) A copy of LLP Agreement (b) A copy of Certificate of Incorporation (c) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. Or In case of a tenderer is registered Society and Registered trust. The tenderer shall submit: (a) A copy of certificate of registration. (b) A copy of Memorandum of Association of Society/Trust Deed (c)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the society/ Trust.
PAN Card copy should be attached.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work shall be submitted.
List of personnel / organization on hand and proposed to be engaged for the tendered work shall be submitted.
Declaration or details has to be submitted by the tenderer if Employment/Partnership etc. of Retired Railway Employees working as per clause -16 of Indian Railways Standard General Conditions of Contract- April2022 (GCC-April-2022).
Provision of One Separate Circuit Breaker (CB) for UTCL Hirmi & Rawan Siding and One Separate CB for RHIPL Siding at HN.
TRD-R-2024-E16
TRD-R-2024-E16
Open
Works - General
365 Days
Raipur, Chhattisgarh
₹0
₹2.0 L
28 Mar 2025
27 Feb 2025
428 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 51,90,352.45 | ||
| — | 10.00 | — | — | ||
| Concrete for foundation& Plinth in other than Hard & Rocky soil | — | — | — | 69,420 | |
| — | 2.50 | — | — | ||
| Reinforced concrete for Cable trench including fixing of the Cable laying tray. | — | — | — | 25,752.5 | |
| — | 2.50 | — | — | ||
| Cable tray with angle frame. | — | — | — | 22,232.5 | |
| — | 2.50 | — | — | ||
| Cable trench covers | — | — | — | 7,112.5 | |
| — | 30.00 | — | — | ||
| Supply of moorum including spreading watering and ramming. | — | — | — | 8,850 | |
| — | 30.00 | — | — | ||
| Supply and spreading of 20mm down grade stone ballast. | — | — | — | 54,720 | |
| — | 1.00 | — | — | ||
| Supply of 25 KV Single pole VCB (2000 A) | — | — | — | 7,40,489 | |
| — | 1.00 | — | — | ||
| Erection of 25 KV Single pole VCB (2000 A) | — | — | — | 17,328 | |
| — | 1.00 | — | — | ||
| Supply of Control & Relay panel for single VCB circuit as per latest RDSO's guideline. | — | — | — | 18,71,307 | |
| — | 1.00 | — | — | ||
| Erection of Control & Relay panel for single VCB circuit as per latest RDSO's guideline. | — | — | — | 9,138 | |
| — | 1.00 | — | — | ||
| Supply of 25 KV Potential Transformer TYPE-II (27.5kV/110V) | — | — | — | 1,00,013 | |
| — | 1.00 | — | — | ||
| Erection of 25 KV Potential Transformer TYPE-II (27.5KV/110V) | — | — | — | 2,374 | |
| — | 1.00 | — | — | ||
| Supply of 25KV Current Transformer CT ratio: (1500-750/5A) | — | — | — | 78,678 | |
| — | 1.00 | — | — | ||
| Erection of 25KV Current Transformer CT ratio: (1500-750/5A) | — | — | — | 2,119 | |
| — | 1.00 | — | — | ||
| Supply of 25KV/240V, 10KVA LT Supply Transformer. | — | — | — | 1,14,323 | |
| — | 1.00 | — | — | ||
| Erection of 25KV/240V, 10KVA LT Supply Transformer. | — | — | — | 4,130 | |
| — | 1.00 | — | — | ||
| Supply of Lead-acid battery 110V,150AH Cap. Including stand and anti acid paint. | — | — | — | 3,21,426 | |
| — | 1.00 | — | — | ||
| Erection of Lead-acid battery 110V,150AH Cap. Including stand and anti acid paint. | — | — | — | 11,571 | |
| — | 1.00 | — | — | ||
| Supply of Battery charger for 110V, 150 AH capacity batteries. | — | — | — | 97,720 | |
| — | 1.00 | — | — | ||
| Erection of Battery charger for 110V, 150 AH capacity batteries. | — | — | — | 4,924 | |
| — | 1.00 | — | — | ||
| Supply of 110V DC fuse box. Matrix RDSO approved. | — | — | — | 20,069 | |
| — | 1.00 | — | — | ||
| Erection of 110V DC fuse box. Matrix RDSO approved. | — | — | — | 541 | |
| — | 1.00 | — | — | ||
| Supply of 230 Volts ACDB for SSP (consist of 63A MCB, Bus Bars, 3 nos. out going with fuse). | — | — | — | 18,562 | |
| — | 1.00 | — | — | ||
| Erection of 230 Volts ACDB for SSP (consist of 63A MCB, Bus Bars, 3 nos. out going with fuse). | — | — | — | 394 | |
| — | 1.00 | — | — | ||
| Supply of Auto Change over switch for SP TI/SPC/PCI/CLS/0020 with AC slip 1,2,3 & 4 with latest amendment. | — | — | — | 49,662 | |
| — | 1.00 | — | — | ||
| Erection of Auto Change over switch for SP TI/SPC/PCI/CLS/0020 with AC slip 1,2,3 & 4 with latest amendment. | — | — | — | 394 | |
| — | 1.00 | — | — | ||
| Supply of Distribution Boards for BM suitable for 9 to 10 BMs. | — | — | — | 2,183 | |
| — | 1.00 | — | — | ||
| Erection of Distribution Boards for BM suitable for 9 to 10 BMs. | — | — | — | 394 | |
| — | 0.25 | — | — | ||
| Supply of Galvanised Feeder masts, main & opposite masts of switching station and mast for LT transformer including with G.I. Fasteners | — | — | — | 30,488.5 | |
| — | 0.25 | — | — | ||
| Erection of Galvanised Feeder masts, main & opposite masts of switching station and mast for LT transformer including with G.I. Fasteners | — | — | — | 1,752.75 | |
| — | 0.15 | — | — | ||
| Supply of Fabricated steel works other than masts. | — | — | — | 13,443.45 | |
| — | 0.15 | — | — | ||
| Erection of Fabricated steel works other than masts. | — | — | — | 660.15 | |
| — | 20.00 | — | — | ||
| Supply of Fencing Panels (2.4 M) height. | — | — | — | 70,080 | |
| — | 20.00 | — | — | ||
| Erection of Fencing Panels (2.4 M) height. | — | — | — | 3,280 | |
| — | 8.00 | — | — | ||
| Supply of Fencing uprights. | — | — | — | 30,368 | |
| — | 8.00 | — | — | ||
| Erection of Fencing uprights. | — | — | — | 5,656 | |
| — | 20.00 | — | — | ||
| Supply of Anti climbing device for Switching station. | — | — | — | 58,140 | |
| — | 20.00 | — | — | ||
| Erection of Anti climbing device for Switching station. | — | — | — | 2,300 | |
| — | 60.00 | — | — | ||
| Supply & Erection Structure Bond. | — | — | — | 22,860 | |
| — | 1.00 | — | — | ||
| Supply & Erection of Longitudinal Bond. | — | — | — | 487 | |
| — | 1.00 | — | — | ||
| Supply and Erection of Transverse/Special Bond. | — | — | — | 1,078 | |
| — | 75.00 | — | — | ||
| Supply of Earth Bus (with 50x 6mm MS Flat). | — | — | — | 10,725 | |
| — | 75.00 | — | — | ||
| Erection of Earth Bus (with 50x 6mm MS Flat). | — | — | — | 5,250 | |
| — | 60.00 | — | — | ||
| Supply of MS strip 75x8mm. | — | — | — | 18,540 | |
| — | 60.00 | — | — | ||
| Erection of MS strip 75x8mm. | — | — | — | 3,660 | |
| — | 5.00 | — | — | ||
| Supply of 8 SWG G.I. wire for earthing RC cubicle & fencing panels. | — | — | — | 225 | |
| — | 5.00 | — | — | ||
| Erection of 8 SWG G.I. wire for earthing RC cubicle & fencing panels. | — | — | — | 120 | |
| — | 50.00 | — | — | ||
| Supply of Control and Indication cable (7X2.5 sqmm Cu) | — | — | — | 19,450 | |
| — | 50.00 | — | — | ||
| Erection of of Control and Indication cable (7X2.5 sqmm Cu) | — | — | — | 1,350 | |
| — | 25.00 | — | — | ||
| Supply of Control and Indication cable (2 X 4 sqmm Cu) | — | — | — | 1,950 | |
| — | 25.00 | — | — | ||
| Erection of Control and Indication cable (2 X 4 sqmm Cu) | — | — | — | 500 | |
| — | 25.00 | — | — | ||
| Supply of Catenary Indication cable (2 X 2.5 sqmm Cu) | — | — | — | 2,950 | |
| — | 25.00 | — | — | ||
| Erection of Catenary Indication cable (2 X 2.5 sqmm Cu) | — | — | — | 450 | |
| — | 5.00 | — | — | ||
| Supply of Copper strip (25 x 3mm) for equipment earthing. | — | — | — | 4,515 | |
| — | 5.00 | — | — | ||
| Erection of Copper strip (25 x 3mm) for equipment earthing. | — | — | — | 240 | |
| — | 30.00 | — | — | ||
| Supply of Bus-bar (Aluminum) (36mmx28mm). | — | — | — | 21,360 | |
| — | 30.00 | — | — | ||
| Erection of Bus-bar (Aluminum) (36mmx28mm). | — | — | — | 6,000 | |
| — | 2.00 | — | — | ||
| Supply of Bus-Terminal (6480) | — | — | — | 3,924 | |
| — | 2.00 | — | — | ||
| Erection of Bus-Terminal (6480) | — | — | — | 302 | |
| — | 2.00 | — | — | ||
| Supply of Bus-splice (6490) | — | — | — | 3,844 | |
| — | 2.00 | — | — | ||
| Erection of Bus-splice (6490) | — | — | — | 302 | |
| — | 2.00 | — | — | ||
| Supply of Bus-Tee connector (6500) | — | — | — | 4,058 | |
| — | 2.00 | — | — | ||
| Erection of Bus-Tee connector (6500) | — | — | — | 288 | |
| — | 2.00 | — | — | ||
| Supply of Terminal connector 36/20mm (6580) | — | — | — | 3,858 | |
| — | 2.00 | — | — | ||
| Erection of Terminal connector 36/20mm(6580) | — | — | — | 286 | |
| — | 2.00 | — | — | ||
| Supply of Tap connector (6520) | — | — | — | 3,552 | |
| — | 2.00 | — | — | ||
| Erection of Tap connector (6520) | — | — | — | 288 | |
| — | 2.00 | — | — | ||
| Supply of 36mm TEE cum splice(6550) | — | — | — | 8,218 | |
| — | 2.00 | — | — | ||
| Erection of 36mm TEE cum splice(6550) | — | — | — | 302 | |
| — | 1.00 | — | — | ||
| Supply of Aluminium Jumper. | — | — | — | 3,591 | |
| — | 1.00 | — | — | ||
| Erection of Aluminium Jumper. | — | — | — | 104 | |
| — | 2.00 | — | — | ||
| Supply of 25KV Post Insulator | — | — | — | 14,976 | |
| — | 2.00 | — | — | ||
| Supply of Component of 25kV Post Insulator | — | — | — | 1,248 | |
| — | 2.00 | — | — | ||
| Erection of 25kV Post Insulator with component | — | — | — | 1,254 | |
| — | 4.00 | — | — | ||
| Supply of Retro reflective Number Plates. | — | — | — | 1,736 | |
| — | 4.00 | — | — | ||
| Erection of Retro reflective Number Plates. | — | — | — | 364 | |
| — | 1.00 | — | — | ||
| Supply of Schematic Diagram Board | — | — | — | 7,162 | |
| — | 1.00 | — | — | ||
| Erection of Schematic Diagram Board | — | — | — | 717 | |
| — | 3.00 | — | — | ||
| Supply of Caution Board for 25 kV AC Traction. | — | — | — | 2,262 | |
| — | 3.00 | — | — | ||
| Erection of Caution Board for 25 kV AC Traction. | — | — | — | 282 | |
| — | 3.00 | — | — | ||
| Supply of Provision of Danger board for 25KV. | — | — | — | 2,262 | |
| — | 3.00 | — | — | ||
| Erection of Provision of Danger board for 25KV. | — | — | — | 282 | |
| — | 8.00 | — | — | ||
| Supply of Single Earth Electrode. | — | — | — | 34,424 | |
| — | 8.00 | — | — | ||
| Erection of Single Earth Electrode. | — | — | — | 17,792 | |
| — | 4.00 | — | — | ||
| Supply and Erection of Fire Bucket | — | — | — | 992 | |
| — | 1.00 | — | — | ||
| Supply and Erection of Fire Bucket Stand | — | — | — | 3,220 | |
| — | 1.00 | — | — | ||
| Supply and Erection of CO2 type or Dry Chemical Powder type Fire Extinguisher (9 ltrs capacity). | — | — | — | 4,173 | |
| — | 1.00 | — | — | ||
| Dismantling of 25KV Interrupter | — | — | — | 6,344 | |
| — | 1.00 | — | — | ||
| Dismantling of CT, PT, NCT, LA | — | — | — | 529 | |
| — | 15.00 | — | — | ||
| Dismantling of Aluminium Bus bar | — | — | — | 780 | |
| — | 5.00 | — | — | ||
| Dismantling of Bus-bar Junction and connectors | — | — | — | 530 | |
| — | 10.00 | — | — | ||
| Dismantling of Control Cable | — | — | — | 220 | |
| — | 1.00 | — | — | ||
| Dismantling of Battery set. | — | — | — | 4,315 | |
| — | 1.00 | — | — | ||
| Dismantling of Battery charger. | — | — | — | 1,079 | |
| — | 1.00 | — | — | ||
| Dismantalling of Distribution board. | — | — | — | 540 | |
| — | 0.05 | — | — | ||
| Dismantling of Steel structure/SPS | — | — | — | 76.1 | |
| — | 1.50 | — | — | ||
| Breaking of foundation plinth of Interrupter, Gantry, fencing upright or any other such structure. | — | — | — | 3,028.5 | |
| — | 1.00 | — | — | ||
| Dismantling of Post Insulator | — | — | — | 265 | |
| — | 1.00 | — | — | ||
| Dismantling of Control & Relay Panel | — | — | — | 1,079 | |
| — | 5.00 | — | — | ||
| Transporting, loading, unloading of materials from work Site to depot and/ or, transportation of dismantled/released items from depot/Work site to GSD Raipur/other Rly. Store for DS-8 purpose. | — | — | — | 30 | |
| — | 5.00 | — | — | ||
| Supply and erection of GI pipe B class 75 mm. | — | — | — | 1,830 | |
| — | 1.00 | — | — | ||
| Provision of General Caution notice for staff drg. No. RE/33/496, specification no. ETI/OHE/33 or latest | — | — | — | 768 | |
| — | 1.00 | — | — | ||
| Provision of General caution notice for entrance to Rly. Stn. No. RE/33/P-7551, specification No. ET/OHE/33(273) or latest | — | — | — | 837 | |
| — | 1.00 | — | — | ||
| Provision of Warning board caution live wire drg. No. ETI/OHE/P-7540, specification no. ETI/OHE/33(2/73) or latest | — | — | — | 1,328 | |
| — | 1.00 | — | — | ||
| Supply & Erection of Section Diagram Board | — | — | — | 15,952 | |
| — | 1.00 | — | — | ||
| Modification to Section Diagram board at Stations and TPC | — | — | — | 2,556 | |
| — | 2.00 | — | — | ||
| Transportation of 13M LONG Buried RAIL (52 kg Or 60 kg as available) | — | — | — | 6,794 | |
| — | 12.00 | — | — | ||
| Supply of Higher productivity fasteners ( Rail Contact system with Tin Plated Copper Bush attachment for fixing of Traction Bond) | — | — | — | 40,764 | |
| — | 12.00 | — | — | ||
| Erection of Higher productivity fasteners ( Rail Contact system with Tin Plated Copper Bush attachment for fixing of Traction Bond | — | — | — | 4,092 | |
| — | 12.00 | — | — | ||
| Supply of RDSO approved high productivity Fastners( rail Contact system) for fixing OHE bonds comprissing of ( a) M-12 stainless steel bolt ( 4 nos) , (b) M-12 Stainless steel washer ( 4 nos) & C) M-12 stainless stell self locking Nut or galavanized full metal locking nut 4 nos SPS (M-12 Bolts, Nuts ,Plain Washer Lock Washer (Spring Steel) | — | — | — | 33,720 | |
| — | 12.00 | — | — | ||
| Erection of RDSO approved high productivity Fastners( rail Contact system) for fixing OHE bonds comprissing of ( a) M-12 stainless steel bolt ( 4 nos) , (b) M-12 Stainless steel washer ( 4 nos) & C) M-12 stainless stell self locking Nut or galavanized full metal locking nut 4 nos SPS (M-12 Bolts,Nuts ,Plain Washer Lock Washer (Spring Steel) | — | — | — | 6,120 | |
| — | 300.00 | — | — | ||
| Excavation and refilling of Soil for Burried rail (15X0.6 X1 ) & Flat/MS Rod laying etc. | — | — | — | 2,03,700 | |
| — | 20.00 | — | — | ||
| Supply of 20mm dia Copper Rivet | — | — | — | 6,360 | |
| — | 20.00 | — | — | ||
| Erection of 20mm dia Copper Rivet | — | — | — | 1,120 | |
| — | 100.00 | — | — | ||
| Earthwork in filling embankment. | — | — | — | 21,600 | |
| — | 100.00 | — | — | ||
| Mechanical compaction of earth/blanketing material | — | — | — | 3,700 | |
| — | 2.50 | — | — | ||
| — | 2.50 | — | — | ||
| Providing and fixing 10mm thick heavy duty acid and/or alkali resistant factory made tiles conforming to Group VRD series of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS: 4457 complete including cost of acid/alkali resistant cement. In dako/skirting 12mm thick mortar 1:4 (1 appropriate cement : 4 coarse sand) | — | — | — | 3,262.5 | |
| — | 100.00 | — | — | ||
| Construction of RCC work for Retaining wall | — | — | — | 6,94,200 | |
| — | — | — | 46,70,607.45 | ||
| — | 10.00 | — | — | ||
| Concrete for foundation & Plinth in other than Hard & Rocky soil | — | — | — | 69,420 | |
| — | 2.50 | — | — | ||
| Reinforced concrete for Cable trench including fixing of the Cable laying tray. | — | — | — | 25,752.5 | |
| — | 2.50 | — | — | ||
| Cable tray with angle frame. | — | — | — | 22,232.5 | |
| — | 2.50 | — | — | ||
| Cable trench covers | — | — | — | 7,112.5 | |
| — | 30.00 | — | — | ||
| Supply of moorum including spreading watering and ramming. | — | — | — | 8,850 | |
| — | 30.00 | — | — | ||
| Supply and spreading of 20mm down grade stone ballast. | — | — | — | 54,720 | |
| — | 1.00 | — | — | ||
| Supply of 25 KV Single pole VCB (2000A) | — | — | — | 7,40,489 | |
| — | 1.00 | — | — | ||
| Erection of 25 KV Single pole VCB (2000A) | — | — | — | 17,328 | |
| — | 1.00 | — | — | ||
| Supply of Control & Relay panel for single VCB circuit as per latest RDSO's guideline. | — | — | — | 18,71,307 | |
| — | 1.00 | — | — | ||
| Erection of Control & Relay panel for single VCB circuit as per latest RDSO's guideline. | — | — | — | 9,138 | |
| — | 1.00 | — | — | ||
| Supply of 25 KV Potential Transformer Type-II (27.5kV/110V) | — | — | — | 1,00,013 | |
| — | 1.00 | — | — | ||
| Erection of 25 KV Potential Transformer TYPE-II (27.5kV/110V) | — | — | — | 2,374 | |
| — | 1.00 | — | — | ||
| Supply of 25KV Current Transformer CT ratio: (1500-750/5A) | — | — | — | 78,678 | |
| — | 1.00 | — | — | ||
| Erection of 25KV Current Transformer CT ratio: (1500-750/5A) | — | — | — | 2,119 | |
| — | 1.00 | — | — | ||
| Supply of 230V AC fuse box. With 16 nos. of fuse unit (Matrix). | — | — | — | 1,838 | |
| — | 1.00 | — | — | ||
| Erection of 230V AC fuse box. With 16 nos. of fuse unit (Matrix). | — | — | — | 246 | |
| — | 0.25 | — | — | ||
| Supply of Galvanised Feeder masts, main & opposite masts of switching station and mast for LT transformer including with G.I. Fastners | — | — | — | 30,488.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .