Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹31.7 L+₹8.3 L (35.5%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹31.7 L+₹8.3 L (35.5%)Rejected-Finance H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L3 | Rejected-Finance Highest bid quoted | |
| 4 | Rejected-Technical NOT AVAILABLE | - | Rejected-Technical Rejected due to indl have no cat of subject work | |
| 5 | Rejected-Technical FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | - | Rejected-Technical Rejected due to overloaded firm |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Gurgaon
Gurgaon
PROVISION OF CERTAIN BR AND EM SANCTIONED WORK AT AF STATION NARAINA UNDER GE AF GURGAON
2021_MES_483235_1
CA NO GE/GUR-/NIT-62/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
PROVISION OF CERTAIN BR AND EM SANCTIONED WORK AT AF STATION NARAINA UNDER GE AF GURGAON
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹90,000
20 Jan 2022
22 Oct 2021
22 Nov 2021
22 Oct 2021
19 Nov 2021
5 Nov 2021
60 days
Amount
Demolition of brick work in any position, built in cement morter or cement lime mortar etc complete all as specified and as directed by Engr-in-charge.
M&L for forming jambs , etc to opening , including cutting, toothing and properly bonding into old work, also facing , jointing and pointing to match existing work, CM (1:4 ) complete all as specified and as directed by Engr-in-charge.
M&L for making good under cills or over arches , lintels and bressumers, including all pinning when necessary , CM (1:4) complete all as specified and as directed by Engr-in-charge.
M&L for 25mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in sub base of floors complete all as specified and as directed by Engr-in-charge.
M&L for 10 mm thick rendering coat for tiling in CM 1:3 on vertical surfaces complete all as specified and as directed by Engr-in-charge.
M&L for 15 mm thick screed coat for tiling in CM 1:4 on floor surfaces complete all as specified and as directed by Engr-in-charge.
M&L for glazed ceramic coloured/ printed tiles 450mmx300mmx7mm thick on walls as in dado/ skirting etc, joints free set and jointed in neat cement slurry and pointed in white cement and pigment to match the colour of tiles including one boarder tile at the top all around with matching boarder complete all as specified and as directed by Engr-in-charge.
M&L for Vitrified ceramic coloured tiles 9 to 10 mm thick (square / rectangular) area of each tiles not exceeding 0.36 Sqm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles including and pointed complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 15mm thick on fair faces of brick work or concrete in CM (1:4) & rendering is to be finishing even and fair complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 10 mm thick over ceiling of brick work or concrete surface in CM 1:3 finished even & smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
M&L for Preparation of new plastered surfaces of wall & apply two coat of oil bound distemper, over a coat of primer over 1-2mm thick putty complete all as specified and as directed by Engineer -in - Charge.
Removing all demolished / taken out material from site up to four storeyed building including loading the material in trucks /carts and throwing out form the AF permisses exceeding 2 KM but not exc 5 KM from the site of work complete all as specified and as directed by Engineer -in - Charge.
M&L for powder coated aluminium frame work doors, windows, partions etc incl grill for windows for windows etc with one or more rebated section incl joiting cleats for fixing, anodised alumnium snap beading screw, alumunium hinges etc complete all as specified and as directed by Engineer -in - Charge.
S&F aluminium colour powder coated anodised door and shutter single or double leaf glazed/pre laminated board exterior quality partly glazed/pre laminated board exterior quality party glazed panels fabricated including aluminium powder coated beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Aluminium colour powder coated door frame section 101.60x44.45x1.93 mm fixed as per spd (b) Aluminium colour powder coated vertical section in shutter 85x44.45x2 mm as per spd. (c) Aluminium colour powder coated Top Rail & style shutter section 95.25x44.45x2.00 mm as per spd. (d) Aluminium colour powder coated handle 02 Nos in each shutter 200 mm long as spd. (e) Aluminium colour a powder coated Tower bolt 02 Nos in each shutter 150 mm long as per spd. (f) Aluminium colour powder coated middle lock rail/bottom rail section 150x44.45x2.00mm cat No.20002. Make-Jindal (g) Six lever mortice lock brass Make : Godrej/Classic on in each door. (h) 12 mm thick particle board (pre laminated both face) exterior grade ISI Marked (j) Tinted glass/Plain glass 5mm thick Make : Saint gobain/modiguard. (h) Floor spring , Make:- Sandu/Amar ISI Note: Prelaminated particle board, tinted glass and door frame shall be measured and paid seperatly.
S&F fabricated anodized aluminium grill of size 75x100mm, using 5mm dia bars fixed to frames using U/V section runners complete all as specified and directed by Engr-in-Charge.
S&F of 12 mm thick particle board preleminated on both side decorative choice etc complete all as specified and as directed.
S&F collapsible steel gate , top hung, consisting of channel pickets , pivoted flat brars, top and bottum runner , brass handles etc. as specified, erected in position and securing runners with holdfasts and brackets , complete all as specified and as directed.
S&F MS framed work such as grills, gratings, etc with ends of bars, shouldered and/ or riveted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk way, railing and framed work of water tanks and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Demolition of cement concrete of any description (un-reinforced) in ground floors and paving n exc. 15 cm thickness (below or above ground level) complete all as specified and as directed by Engr-in-charge.
M&L for Plain cement concrete 1:4:8 Type D-2 (using 40mm graded stone aggregate) 75mm thick as in sub base complete all as specified and as directed by Engr-in-charge.
S&F Non skid coloured glazed ceramic tiles 7mm to 8 mm thick, area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm of each tile in floors etc, joints free set and jointed in cement slurry and pointed in white or coloured cement to match exist colour all as specified.
All as per item No.23 hereinbeore but as in skirting skirting on veritical surface.
Dismantling of floor , hearth , or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 20-25 mm thick chequered designer coloured tiles, Size, colour and shape as approved by GE, set and jointed in neat cement slurry and pointed with coloured cement to match etc complete all as specified and as directed.
Taking down cement plaster from brick work or concrete surfaces including ceilings /tile if any & racking out joints haking for keys & scrubing down with water etc. complete all as specified.
M&L for Rendering 15mm thick on fair faces of brick work or concrete in CM (1:6) & rendering is to be finishing even & smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
M&L for Rendering 15mm thick on fair faces of concrete surfaces in CM (1:4) & rendering is to be finishing even & fair as in chajjs, fins, RCC parapet, facia etc complete all as specified and as directed by Engr-in-charge.
M&L for applying two or more coat of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistanceas per IS-15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silcon additivies @1.43ltr/10Sqm over and including priming coat of exterior primer applied @0.90ltr/10 sqm over new Surface complete all as specified and as directed by Engr-in-charge.
M&L complete removal of existing treatment of surfaces of wall and applying two coats of OBD over 5mm thick birla wall putty for smooth the wall surface including scraping old surface of wall complete all as specified and as directed by Engr-in-charge.
M&L complete removal of existing treatment for applying two or more coat of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistanceas per IS-15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silcon additivies @1.43ltr/10Sqm over and including priming coat of exterior primer applied @0.90ltr/10 sqm over new Surface complete all as specified and as directed by Engr-in-charge.
M&L for point wiring complete with stranded copper conductor 2.5 sq mm single core (nominal area) PVC insulated and unsheathed cable 1100 volts grade drawn in and including medium duty concealed PVC conduit conforming to IS : 9537 (Para-3) and ISI marked not less than 25 mm dia with 1.6 mm thick concealed pressed steel terminal boxes factory made and painted with stove enameled black , top cover 2.8 mm thick plastic laminated sheet of required colour fixed with brass screw and cu washers with all accessories including single core stranded copper conductor connected PVC unsheathed cable in same conduit as earth wire to the common earth and connecting to earth dolly all as secified for one 6 pin socket outlet two in one 16/6 amps on an independent board.
S&F switch piano, flush type single pole 15 Amps complete all as specified and as directed by Engr-in-charge.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and as directed by Engr-in-charge.
Supply & Fixing made epoxy powder coated Distribution Board TP & N 8 ways (VTPN MCCB DB) with metal door (IP-42 protection ) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with Knockouts and suitable for one FP-MCCB 63/100 Amp as incomer and 12/24/36 SP MCBs or 4/8/12 TP MCBs ( or any combination of SP/TP MCBs ) outgoings conforming to IS : 8623 complete all as specified and as directed.
S&F MCB single pole and neutral 63 Amps 230 volts 'B' series complete all as specified and as directed at site complete all as specified and as directed.
S&F MCB signle pole 6-32 Amps 230 volts 'B' series complete all as specified and as directed.
S&F 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 35 KA cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
M&L for GI pipe light grade 80 mm bore with fitting laid in trenches under road, along pole/ building, protection of cable including necessary MS clamps for supporting of pipe complete all as specified and directed.
Supply and Laying /Fixing of cable on wall with clamp cable XLPE Insulated screened PVC bedded, Galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 core complete all as specified and directed.
Supply and Fixing of cable on wall with clamp cable XLPE Insulated screened PVC bedded, Galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 4 core. complete all as specified and directed.
S&F factory made epoxy polyster powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet double door (IP-42 protection) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP RCBO or DP MCB and RCCB as incomer and 6 SP MCB's as outgoings complete all as specified and confirming to IS: 8623 complete all as specified and directed.
S&F of MCB distribution board vertical triple pole and neutral 8 way factory made sheet steel, phosphates, powder painted with 200 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified.
S&F submain wiring with unsheathed multi-stranded copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 20mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core and one run of 2.5 Sqmm PVC insulated copper conductor for earth continuity wire complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.
M&L for point wiring complete with stranded copper conductor 4 sq mm single core (nominal area) PVC insulated and unsheathed cable 1100 volts grade drawn in and including medium duty concealed PVC conduit conforming to IS : 9537 (Para-3) and ISI marked not less than 25 mm dia with 1.6 mm thick concealed pressed steel terminal boxes factory made and painted with stove enameled black , top cover 2.8 mm thick plastic laminated sheet of required colour fixed with brass screw and cu washers with all accessories including single core stranded copper conductor connected PVC unsheathed cable in same conduit as earth wire to the common earth and connecting to earth dolly all as secified for one 6 pin socket outlet two in one 16/6 amps on an indeendent board.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp complete switch piano, flush type single pole, one way, 6 Amps, 240 volts all as specified and directed .
Supply and installed hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with with heating and cooling effect of 5 star rating and EER 3.2.of capacity 2.0 TR With Eco-Friendly Refrigerant inverter type and condenser, evapourator and interconnecting tubing all in copper complete all as specified and directed.
Supply and fix voltage stablizer single phase automatic operation naturally air cooled indoor wall mounting type suitable for 2.0 TR Air conditioner designed for input voltage variation in the range of 150V to 285V with output voltage stabilised at 230V+ 2.5% of capacity 5 KVA complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation etc or for shifts wells cesspits, manholes,pier holes etc 10 Sqm on plan and n exc 1.5 m depth and getting out in hard dense soil complete all as specified and as directed by Engr in charge .
Returning, filling in, Hard/ dense soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by Engr in charge .
Removal excavated material to distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point in soil complete all as specified and as directed by Engr in charge .
M&L for sand cushioning with a layer of sand 80 mm thick before laying of cables and 150 mm thick after laying of cables in trenches, or in Existing duct as directed for electric cables for protection incl.consolidation complete all as specified and directed.
M&L for brick protection with sub class B bricks,laid dry flat over electric cables in trenches complete all as specified and directed,
M&L for Boring of holes below 600mm under road,pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
cuckoo enterprises
PAWAN KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .