| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest and Reasonable | |
| 2 | L2₹37.5 L+₹1.8 L (4.94%)Rejected-Finance 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹37.9 L+₹2.2 L (6.17%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹41.3 L+₹5.6 L (15.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹41.4 L+₹5.7 L (15.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) Srinagar
Military Engineer Services Garrison Engineer (AF) Srinagar Air Force Station Srinagar-190007
CERTAIN MAINT OF BR AND EM WORKS AT BB CANTT, 727 AREA, LALGAON AREA AND OTHER AREA UNDER GE (AF) SRINAGAR.
2023_MES_597784_1
GE(AF)SGR-21 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF SRINAGAR
As per Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE (AF) SRINAGAR
₹80,000
Yes
21 Aug 2023
24 May 2023
21 Jun 2023
24 May 2023
20 Jun 2023
7 Jun 2023
Amount
Dismantling of Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings including ridges, hips, valleys and flashings etc complete all as specified and as directed by Engineer-in-Charge. Note:- (i) The rate quoted shall also be deemed to include for taking down of wind ties.
S&F Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with hooks L type or J type or cranked hook bolts , in roofs, walls etc with grade of zinc coating 275, Complete. Note :- Quoted Rates shall be deem to include for Fixing only Wind Tie retrived from BOQ Item No 01
S & F Plain, galvanised, mild steel sheeting, 0.63 mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, Complete.
M&L for Preparation of new zinc (or galvanised) steel and iron roof surfaces of any description over 10 cm width or girth to receive painting, by coating with mordant solution including washing and cleaning, etc and applying two coat of synthetic enamel paint over one coat red oxide primer complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including rubbish off the premises, all as specified..
M&L for granite (of any type) work (table rubbed and polished) 20 mm thick as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over screed bed in cm 1:4, complete.
M&L 15 mm thick screed or bedding layer in cement mortar (1:4) for laying floor finishes, complete all as specified.
M&L for 10 mm thick rendring / backing coat in cement mortar (1:4) to receive wall tiles, complete all as specified.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over screed bed.
M&L for coloured glazed ceramic tiles in vertical surfaces of size300x600x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified.
M&L for coloured vitrified ceramic tiles 10 mm thick (square) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over existing screed bed, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, Complete
M& L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in hard standing / pavings / plinth protections, finished even and smooth without using extra cement, Complete.
Demolition of stone boulder masonry, built in cement mortar including all quoins, pillars etc. Complete.
M&L for stone masonary Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6
All as per item No 16 above but except stone, using old stone retrived from item No 15 above.
M&L for Wooden panelling of second class softwood 12 mm thick with tongue and groove joint fixed in any position over and including wooden framework in second class softwood with plain fillets square or sectional area exc 13 Sqcm and n exc 25 Sqcm at n exc 90 cm centre to centre in both direction and including two or more coat of french polishing on all the exposed surfaces wooden panelling including taking down old paneling and with existing electrical fittings and re-fixing the same electrical fitting complete.
Taking down cement plaster of any description on brick or stone masonary wall , etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified.
M&L for Rendering 15 mm thick in CM 1:4 on stone masonary wall surface and finishing even and smooth without using extra cement complete
M&L for applying 3 mm thick cement base wall care putty on plastered surface of wall, and making the surafce even & smooth for reciving distemper / paint of any descreption all as specified & directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over one coat of primer all as specified and directed. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid seperatly
M&L Preparing of new surface of wall and applying two coats of cement based paint over one coat of primer.
Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
S&F 15 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified.
Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
S&F 20 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified.
M&L for Lagging to pipes 20 mm bore used in external water supply or plumbing all around with 50 mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge 20 mm mesh complete including taking down of old lagging all as specified and directed by Engineer-in-Charge
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 630 x 450 mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, chain and plug and porcelain stopper, etc complete.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete.
S&F in repair PVC waste pipe flexible for WHB of 32 mm size complete.
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover, white, closed pattern with flat bottom, and cover with aluminised hinging device, brass chromium plated Jet shower with one meter long flexible pipe including all connection complete.
S&F in repair PVC low level flushing cistern, valveless, syphonic action type, double push botton, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete complete all as specified.
S&F in repairs for 15 mm size bib taps fancy type, cast copper alloy chromium plated, with capston head, screwed down, screwed for iron pipe or for brass ferrule and fixed, all as specified.
S&F in repair , Stop valve/angle valve Fancy type CP cast copper alloy screwed down high pressure with capstain head for pipe of bore 15mm complete all as specified and directed by Engineer in Charge.
S & F in repairs 15 mm size wall mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15 mm size central hole basin mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe including 450 mm long braided connection pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated Jet Spray of Standard size for EWC alongwith CP connection and all fittings as fixed, complete all as specified and directed by Engineer-in-Charge.
S&F in repair ABS plastic chromium plated Health faucet fixed with spring action and lever along with Flexible hose with brass nut of length 1 m to 1.2 m fitted in the existing water connection in the toilets, Complete all as specified and directed by Engineer-in-Charge.
S&F in repair Glass Shelf of size 500 mm x 125 mm wide with stainless steel wire guard fixed on wall with and including bracket and brass screws and wooden / plastic cleats. Make:- Prayag or equvallent make mention in Appx A.
S & F in repair Corner Glass Shelf of size 300 mm with stainless steel wire guard fixed on wall with and including bracket and brass screws and wooden / plastic cleats. Make:- Prayag or equvallent make mention in Appx A.
S&F in repair Tubular towel rail stainless steel chromium plated 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs, 125 mm dia stainles steel chromium plated grating, fixed in position Complete.
M&L for Complete removal of existing treatment from Plastered surfaces of walls including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engineer-in-charge. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid seperatly
M&L for preparation of old painted wooden surfaces of any description and positions, exc 10cm width or girth and applying one coat of synthetic enamel paint complete.
M & L for preparation of old painted steel surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint in any pattern complete.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
S&F 3 mm thick sheet glass, ordinary quality and glazing with wooden beads in square or rectangular in section n exc 0.5 sq.m in each pane fixed with beads complete .
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tack or galvanised wire staples or fixed with nails and wooden beads, complete .
Supply & fixed 25 mm thick second class soft wood planed one side & edges tongued and grooved or rebated, fixed wih nail inluding repairs to existing floors in patches, including cutting out, piecing,heading joints etc complete.
S&F 20 mm Stainless steel curtain rod with stainless steel bracket and satinless steel finils, fancy type as approved by GE, as in curtain rods including taking down the old curtains rods complete all as specified and directed by Engineer-In-Charge.
Dismantling wall and ceiling boards, fibre pulp insulation etc or insulation boards/slabs/ blankets, any thickness, including cover fillets, all as specified.
S&F false ceiling of Non asbestos fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 6 mm thick fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium fram work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified directed by the Engineer-in-Charge.
M&L for coloured rubber moulded glossy finish Chequerred cement concrete tiles30cm x 30cm x 25mm thick set and jointed in neat cement slurry with grey cement and pigment in floors complete all as spfd.
Taking down Shutters and refixing in same opening after easing and adjusting incl all accessories materials of any description n.exc 1 sq. m each including resecuring/changing of builders hardware complete all as specified and directed.
Taking down point wiring with aluminum/copper conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator DB boxes with all fixtures service wire etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distemper to match with existing wall/floor/ceiling finishes complete all as specified and directed.
M&L point wiring 1100 volt grade single core FRLS/ FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed type including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel sunken box thickness not less than 1.8 mm on wall for mounting of piano/flush type switches, switch sockets, fan regulator etc any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
All as per srl item No 57 above but One light point controlled by one switch and complete all as specified and directed.
All as per srl item No 57 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed.
All as per srl item No 57 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per srl item No 57 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per srl item No 57 but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC caping on surface of wall not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel sunken box thickness not less than 1.8 mm on wall for mounting of piano/flush type switches, switch sockets, fan regulator etc any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
All as per srl item No 58 above but One lihgt point controlled by one switch and complete all as specified and directed.
All as per srl item No 58 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed.
All as per srl item No 58 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per srl item No 58 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per srl item No 58 but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
All as per srl item No 58 but One bell/buzzer point controlled by one bell push complete all as specified and directed.
M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
All as per srl item No 59 above but One lihgt point controlled by one switch and complete all as specified and directed.
All as per srl item No 59 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed.
All as per srl item No 59 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per srl item No 59 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per srl item No 59 but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade, casing caping on surface of wall not less than 25mm width with IS 9537 (Part-III) 1983 marked medium grade on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxes sunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular cover with frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
All as per srl item No 60 above but One lihgt point controlled by one switch and complete all as specified and directed.
All as per srl item No 60 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specified and directed.
All as per srl item No 60 above but One 3 pin 5 amp socket out point on the same board with other switches complete all as specified and directed.
All as per srl item No 60 above but One 3 pin 5 amps socket out let point on independent board complete all as specified and directed.
All as per srl item No 60 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point complete all as specified and directed.
Supply and fix in repair building security light LED 25 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc complete all as specified and directed.
S&F in repair modular one way switch 6 Amp 240 volts suitable for one module complete all as specified and directed.
S&F in repair modular one way switch 16 Amp 240 volts suitable for one module complete all as specified and directed.
S&F in repair modular 6 Amp socket suitable for two module 240 volts complete all as specified and directed.
S&F in repair modular 16 Amp socket suitable for two module 240 volts complete all as specified and directed.
S&F in repair modular step type fan regulator suitable for 120 watt 250 volts complete all as specified and directed.
S&F in repair piano type one way switch 6 Amp 240 volts suitable complete all as specified and directed.
S&F in repair piano type one way switch 16 Amp 240 volts suitable complete all as specified and directed.
S&F in repair piano type 6 Amp socket suitable for 240 volts complete all as specified and directed.
S&F in repair piano type 16 Amp socket suitable for 240 volts complete all as specified and directed.
S&F in repair piano type step type fan regulator suitable for 120 watt 250 volts complete all as specified and directed.
S&F in repair lamp holder/batten holder Polycorbonate type with back plate suitable for batten fitting including supply&fixing of 10 watt retrofit lamp.
S&F in repair ceiling rose with three terminal as per relevant IS complete all as specified and directed.
Supply only 10 watt LED bulb complete all as specified and directed.
Supply and fix in repair Energy efficient surface mounted 2'X2' grid Ceiling LED fitting 36/40 W rated voltage 240 V, 50Hz combination with profiled and flat diffuse complete all as directed by the Engineer-in-Charge.
Supply and fix in repair LED baton fitting 2' length including drivers having energy consumption, 10/11W (White/warm white) ,230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
Supply and fix in repair LED baton fitting 4' length including drivers having energy consumption, 18/20W(White/warm white) ,230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
Supply & fix in repair light fitting 9W bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ complete all as specified and directed.
Supply & fix in repair fittings with surface mount LED down lighters 12 W including driver with rated voltage 240 V , 50 Hz, complete all as specified and directed.
Supply and fix in repair building security light LED 25 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc complete all as specified and directed.
S&F in repair call bell ding dong type 230 Volts 50 Hz complete all as specified and directed by Engr-in-Charge
Supply and fix in repair sheet metal enclosure epoxy powder coated or polysterene insulated material double door type, vertical triple pole & neutral(VTPN) with MCCB 100 amps ICs=ICu,for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door complete all as specified and directed.
Supply and fix in repair epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door) 8 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit complete all as specified andas directed by Engr-in-Charge.
Supply and fix in repair epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door) 12 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit complete all as specified andas directed by Engr-in-Charge.
S&F in repair MCB triple pole and neutral ISI marked C series working on 415 volts 50HZ AC supply for incoming and outgoing controlling system capacity 63 Amps 10 KA breaking capacity etc all as specified and directed.
S&F in repair MCCB three pole ISI marked working on 415 Volts 50Hz supply for incoming and outgoing controlling system of capacity 150 Amps all as specified and directe. Amps, 16 KA breaking capacity Ics=Icu etc all as specified and directed by Engr-in-Charge.
Supply and fix MCB single pole 240 volt 6 to 32 amps 10 KA breaking capacity, 'C' series complete all as specified and directed.
Supply and fix in repair MCB single pole and neutral 40 Amp 240 volt amps 10 KA breaking capacity, 'C' series, complete all as specified and directed.
Supply and fix in repair MCB single pole and neutral 63 Amp 240 volt amps 10 KA breaking capacity, 'C' series, complete all as specified and directed. MakeLegrand/ L&T/ Havells.
Supply and fix in repair metal clad plug & socket board SP&N enclosure with 2 pole and earth metal plug and socket complete 20 Amp MCB SP C curve, complete all as specified and directed.
Supply and fix in repair metal clad plug & socket board triple pole and neutral enclosure with 3 pin and earth plugs and socket complete with one triple pole MCB 32 Amps 415 Volts C type complete all as specified and directed.
S&F in repair switch socket combination 16 Amps 5 in-1 pin type comlete all as specified and directed by Engr-in-Charge.
S&F in repair switch socket combination 6 Amps 3 in-1 pin type comlete all as specified and directed by Engr-in-Charge.
M&L for submain wiring with three run of single core multistranded copper conductor cable, of size 6.0 sqmm PVC insulated, unsheathed conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.0 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down and wiring complete. Note:- (i) 3 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purose.
M&L for submain wiring with two run of single core multistranded copper conductor cable, of size 4.0 sqmm PVC insulated, unshea conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 2.50 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down and wiring complete. Note:- (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purose.
Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion.
M/S MIR AND CO
M/S LATIF AHMAD MIR
M/S ZAHOOR ENTERPRISES
HAJI ZAHOOR HUSSAIN GANIE
M/S A.R.TANTARY
M/S MAQBOOL BHAT & SONS
M/S Thakur & Sons
M/S BASHIR AHMAD TANTARY
M/S NEW FAROOQ TRADERS
M/S LUCKY BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .