Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance | L1 | Accepted-Finance Lowest quoted | |
| 2 | L2₹2.1 L+₹2,445.95 (1.20%)Rejected-Finance | L2 | Rejected-Finance Highest quoted |
Tender Value
₹2.5 L
EMD Value
₹2,490
Closing Date
13 Sept 2024, 3:00 pmClosed
THE COMMISSIONER, SALEM CITY MUNICIPAL CORPORATION
Salem City Municipal Corporation, Fort Main Road, Salem.
Construction of motor room for Motor and compressor and Construction of pedestal for 1000 ltr. HDPE tank, Supply and delivey of HDPE 1000ltr in Division 9, Ammapet Zone.
2024_MAWS_479247_1
E2-EST NO-670-WS-2023-2024
Open Tender
Civil Works - Water Works
Lump-sum
15 days
SALEM CITY MUNICIPAL CORPORATION
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹2,490
27 Jan 2025
31 Aug 2024
13 Sept 2024
31 Aug 2024
13 Sept 2024
31 Aug 2024
Amount
Providing Construction of pedestal for Motor compressor including cost of earth work PCC 1:4:8 using 40 mm metal, RCC Pre cost slab (50mm Thick) 1:2:4 using 20 mm metal, brick work in CM 1:5 using country bricks, plastering in CM 1:3, 12mm thick, and GI Steel door with locking arrangements and filling with earth etc., as per standard specification including all cost and conveyance etc., complete.
Construction of pedestal for 1000 ltr. HDPE tank, including cost of HDPE tank as per IS 12701 / 1996, cost of earth work, PCC 1:4:8 using 40mm metal, PCC 1:2:4 using 20mm metal, brick work in CM 1:5 using country bricks, plastering in CM 1:5 12mm thick and filling with earth etc. as per standard specification including all cost and conveyance ete. complete.
Supply and delivery, fixing of 1000 Ltr HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., {TWAD SR.P.No.89}
Supply and Delivery of Following Materials ISI standarad etc, complete.
32mm GI Pipe {TWAD SR.P.No.40}
20mm Gi Bend {TWAD SR.P.No.44}
32mm Gi Hex Nipple {TWAD SR.P.No.44}
32mm Gi Elbow {TWAD SR.P.No.44}
Thread Ball {TWAD SR.P.No.160}
Shellac {TWAD SR.P.No.160}
25mm Pvc Tank Nipple
25mm Pvc Ball Valve
20mm Gi B.Nipple 9"
32mm Gi B.Nipple 12"
32mm GI B.Nipple 6"
32mm Gi Union {TWAD SR.P.No.44}
32mm GI Coupling {TWAD SR.P.No.44}
32mm Gi Bend {TWAD SR.P.No.44}
Plumber Class-I {PWD SR P.No.10}
Plumber Class-I {PWD SR P.No.10}
Plumber Class-II {PWD SR P.No.11}
Plumber Class-II {PWD SR P.No.11}
Supply and fixing of EB service line cable required length, Insulated GI wire, Reel for EB service line, Service wire and other particulars incuding transportation etc, Complete. i.Soundamman kovil street
7/20 Wire {Ele Data.SR.P.No 58}
Stay Wire {Ele Data.SR.P.No 35}
Binding Wire {Ele Data.SR.P.No 35}
1.5 sqmm Copper Wire {TWAD SR P.No.203}
20mm Gi Tee {TWAD SR P.No.44}
32A Fuse Unit {Ele Data.SR.P.No 58}
20mm GI Pipe {TWAD SR P.No.40}
Screw {PWD SR P.No.38}
Two Way Reel
20mm WL Clamps
SS Nails
Insulation Tape {PWD SR P.No.138}
32A MCB DP {PWD SR P.No.141}
32A neutral link {Ele Data.SR.P.No 59}
Earth link (1" x 1/8") copper flat {Ele Data.SR.P.No 59}
Earth connection {Ele Data.SR.P.No 59}
T Bolt
Wireman Grade I {TWAD SR P.No.15}
Wireman Grade II {TWAD SR P.No.16}
Supply and fixing of EB service line cable required length, Insulated GI wire, Reel for EB service line, Service wire and other particulars incuding transportation etc, Complete. i.Ramamoorthy Pudur main road
7/20 Wire {Ele Data.SR.P.No 58}
Stay Wire {Ele Data.SR.P.No 35}
Binding Wire {Ele Data.SR.P.No 35}
1.5 sqmm Copper Wire {TWAD SR P.No.203}
20mm Gi Tee {TWAD SR P.No.44}
32A Fuse Unit {Ele Data.SR.P.No 58}
20mm GI Pipe {TWAD SR P.No.40}
Screw {PWD SR P.No.38}
Two Way Reel
20mm WL Clamps
SS Nails
Insulation Tape {PWD SR P.No.138}
32A MCB DP {PWD SR P.No.141}
32A neutral link {Ele Data.SR.P.No 59}
Earth link (1" x 1/8") copper flat {Ele Data.SR.P.No 59}
Earth connection {Ele Data.SR.P.No 59}
T Bolt
Labour Charges
Wireman Grade I {TWAD SR P.No.15}
Wireman Grade II {TWAD SR P.No.16}
Supply and fixing of EB service line cable required length, Insulated GI wire, Reel for EB service line, Service wire and other particulars incuding transportation etc, Complete. i.Valluvar colony
7/20 Wire {Ele Data.SR.P.No 58}
Stay Wire {Ele Data.SR.P.No 35}
Binding Wire {Ele Data.SR.P.No 35}
1.5 sqmm Copper Wire {TWAD SR P.No.203}
20mm Gi Tee {TWAD SR P.No.44}
32A Fuse Unit {Ele Data.SR.P.No 58}
20mm GI Pipe {TWAD SR P.No.40}
Screw {PWD SR P.No.38}
Two Way Reel
20mm WL Clamps
SS Nails
Insulation Tape {PWD SR P.No.138}
32A MCB DP {PWD SR P.No.141}
32A neutral link {Ele Data.SR.P.No 59}
Earth link (1" x 1/8") copper flat {Ele Data.SR.P.No 59}
Earth connection {Ele Data.SR.P.No 59}
T Bolt
Wireman Grade I {TWAD SR P.No.15}
Wireman Grade II {TWAD SR P.No.16}
Sri Enterprises (BID ID -1136002)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .