Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹39.9 L+₹2.8 L (7.57%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹40.6 L+₹3.5 L (9.33%)Rejected-Finance A 46 ARYA NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹44.4 L+₹7.3 L (19.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical No remark recommended in WLR report QE Jun 2025 by this office |
| Sl No | Description | Qty | Unit | GAR CONSTRUCTIONS L2 | shiva construction L4 | M/s ASK Enterprises L3 | ALAKNANDA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work built in cement mortar or cement lime mortar including all quoin arches complete all as specified and directed | 10 | Cum | 150 ₹1,500 | 200 ₹2,000 | 200 ₹2,000 | 100 ₹1,000 Lowest |
| 2.00 | Taking down cement plaster on any type of surface finishes, racking out joints hacking for key scrubbing down with water in any description in any position complete all as specified and directed. | 390 | Sqm | 10 ₹3,900 Lowest | 20 ₹7,800 | 10 ₹3,900 Lowest | 20 ₹7,800 |
| 3.00 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) n exc 1.5 sqm each complete all as specified & directed. | 20 | Each | 60 ₹1,200 | 50 ₹1,000 Lowest | 100 ₹2,000 | 100 ₹2,000 |
| 4.00 | Taking down chowkhat with shutter (without taking off shutter from the frame) exc 1.5 Sqm and not exc 4 Sqm each. | 18 | Each | 90 ₹1,620 | 50 ₹900 Lowest | 150 ₹2,700 | 90 ₹1,620 |
| 5.00 | Taking down of shutter exc 1 sqm and n exc 2 sqm each and refixing in same opening after easing, adjusting etc complete all as specified and directed | 10 | Each | 300 ₹3,000 | 50 ₹500 Lowest | 120 ₹1,200 | 80 ₹800 |
| 6.00 | Demolition cement concrete (unreinforced) as in ground floor and paving not exceeding 15cm thick below or above the ground level | 30 | Cum | 150 ₹4,500 | 200 ₹6,000 | 200 ₹6,000 | 100 ₹3,000 Lowest |
| 7.00 | Dismantling AC/CGI/Fibre sheet (Corrugated, Semi corrugated etc) as in rooof etc complete as as specified | 450 | Sqm | 5 ₹2,250 Lowest | 20 ₹9,000 | 20 ₹9,000 | 10 ₹4,500 |
| 8.00 | Dismantling wall and any type of ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness fixed to any type of frame including cover fillets complete all as specified. Note : Any damage occurred on electrical fitting/fixtures during execution of work be repair/rectified and making good disturbed portion by the contractor on his own arrangement. | 320 | Sqm | 5 ₹1,600 Lowest | 25 ₹8,000 | 20 ₹6,400 | 5 ₹1,600 Lowest |
| 9.00 | Dismantling of concrete post as in Roof truss/Pauline etc any section in any description and making good in disturbed portion | 50 | RM | 5 ₹250 Lowest | 50 ₹2,500 | 50 ₹2,500 | 10 ₹500 |
| 10.00 | Dismantling floor hearth wall tiling (but not backing) removing servicable tiles to store rubbish off the premises complete all as specified and directed. Note : Any damge occurred on electrical fitting/fixtures during execution of work be repair/ rectified and making good disturbed portion by the contractor on his own arrangement. | 435 | Sqm | 10 ₹4,350 Lowest | 25 ₹10,875 | 30 ₹13,050 | 15 ₹6,525 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
Alwar
COMPREHENSIVE MAINTENANCE TO CERTAIN OTM ACCN INCL E/M OF MED REGT, ARTY DIV AND FD HOSP UNDER B/R-II AT ITARANA CANTT ALWAR
2025_MES_724453_1
8441/E8
Open Tender
Civil Works
Item Rate
330 days
Alwar
As per NIT
6 documents required · 6 mandatory
₹500
GE Alwar
₹94,000
Yes
26 Dec 2025
4 Aug 2025
4 Sept 2025
4 Aug 2025
2 Sept 2025
19 Aug 2025
4 Aug 2025 - 18 Aug 2025
Amount
Demolition of brick work built in cement mortar or cement lime mortar including all quoin arches complete all as specified and directed
Taking down cement plaster on any type of surface finishes, racking out joints hacking for key scrubbing down with water in any description in any position complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n exc 1.5 sqm each complete all as specified & directed.
Taking down chowkhat with shutter (without taking off shutter from the frame) exc 1.5 Sqm and not exc 4 Sqm each.
Taking down of shutter exc 1 sqm and n exc 2 sqm each and refixing in same opening after easing, adjusting etc complete all as specified and directed
Demolition cement concrete (unreinforced) as in ground floor and paving not exceeding 15cm thick below or above the ground level
Dismantling AC/CGI/Fibre sheet (Corrugated, Semi corrugated etc) as in rooof etc complete as as specified
Dismantling wall and any type of ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness fixed to any type of frame including cover fillets complete all as specified. Note : Any damage occurred on electrical fitting/fixtures during execution of work be repair/rectified and making good disturbed portion by the contractor on his own arrangement.
Dismantling of concrete post as in Roof truss/Pauline etc any section in any description and making good in disturbed portion
Dismantling floor hearth wall tiling (but not backing) removing servicable tiles to store rubbish off the premises complete all as specified and directed. Note : Any damge occurred on electrical fitting/fixtures during execution of work be repair/ rectified and making good disturbed portion by the contractor on his own arrangement.
M&L brick work with fly ash 'brick straight or curved on plan exc 6m mean radius built cement mortar 1:6 complete all as specified and as directed
All as per ser item No 11.00 above but except bricks
M&L 15mm thick rendering in cement mortar 1:6 on fair faces of brick work surface rendering is to be even and smooth without using extra cement complete all as specified and directed
M&L rendering 15mm thick cement mortar 1:4 on other than fair faces of brick or concrete surface of wall rendering is to be finished even and smooth without using using extra cement complete all as specified and directed
M&L for Rough cast plaster on exterior walls applying the under coat of cement and sand mortar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered complete all as specified and directed by Engineer in Charge
M&L for taking down and removal of loose / disintegrated old concrete up to 50 mm depth/ plaster and cleaning all loose dust washing with water and applying bonding coat into bond AR or equivalent of modified styrene butadiene emulsion (SBR Bonding agent by volume with the brushes etc to bind New Cement plaster/ polymer Modified plaster/ concrete/ screed concrete with old surface etc complete.
M&L for applying 15mm thick plaster with polymer modified mortar fortified with SBR (Nit bond SBR 45 ) in proportion 1:3 by weight 5 litres Nit bond SBR 45 to added to 50 KG Cement with 13 litre water addition, finished surface to match with existing adjoining surface of ceiling, beams and alike complete all as specified and directed.
M&L and applying two or more coats of 2 component zinc based epoxy rust preventer (Nit zinc Primer-M) on corroded reinforcement after cleaning and removing the rust from corroded reinforcement with the help of wire brush and treating it with rust remover (Reebaklens RR) including thoroughly cleaning washing air blowing brushing etc complete all as specified and directed. Note : Qty of Zinc based epoxy rust prevent or only shall be taken into account for payment purpose on the basis of actual consumption.
M&L rendering in patches in repairs (n.exc 3 Sqm each patch) 10mm thick in cement mortar 1:4 on fair faces of Brick/stone/concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed
M&L preparation of newly plastered surface of wall and applying two coats cement base paint over a coat of primer complete all as specified and directed
M&L preparation of newly plastered surface of wall and applying two coats oil bound distemper over a coat of primer complete all as specified and directed
M & L for preparation of old decorated surface of walls etc and applying one coat of oil bound distemper of approved shade/tint complete all as specified and as directed by Engr-in-Charge.
M&L machine cut kota stone flooring 18 to 20 mm thick over cement screed bed 1:4, 20mm thick laid and jointed in grey cement slurry mixed with pigment to match the shed of the slab including rubbing polishing complete all as specified and as directed
All as per ser item No 23.00 above but as in skirting over and including rendering 10mm thick cement mortar 1:4
M&L grinding, rubbing polishing of existing kota stone/terrazzo flooring complete all as as directed
M&L 75 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete as floor sub base complete all as specified and directed
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
M&L chequered cement concrete (coloured) tiles 30cmx30cm x25mm thick set and jointed in net cement slurry in floor and pointed with white cement and pigment including cement mortar screed bed 1:4 20mm thick complete all as specified and directed
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
M&L Non skid ceramic tiles 7 to 8mm thick exc 0.18 sqm but n exc 0.36 sqm as in floor set and jointed in neat cement slurry and pointed in colour cement to match the shed of colour over and including 15mm thick cement mortar screed bed 1:6 complete all as specified and directed.
All as per ser item No 30.00 above but in skirting and dado including 10mm thick rendering cement mortar 1:4 complete all as specified and directed.
M&L for non skid ceramic tiles (coloured) 7 to 8 mm thick any colour of area of each tiles exc 0.06 Sqm but n exc 11 sqm each set and jointed in neat cement slurry and pointed with white or coloured cement to match the shed of tiles laid over and including 15 mm thick cement mortar screed bed 1:6 complete all as specified and directed.
M&L for Glazed ceramic tiles any colour in vertical surface 300x450x7 / 300 x 600x 7 mm thick over 10 mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed. complete all as specified & directed..
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out in loose/soft soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed
S&F for structural steel as in Trusses , purlins, rafter made of Hallow /square/rectangle/round section including vertical member and necessary tee, angle, cleats including necessary cutting welding notching complete all as specified and directed
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide complete all as specified and directed.
M&L PCC (1:4:8) type D-2, using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F plain galavanized mild steel plain sheeting 0.50mm thick in ridges, hips, valley gutters, drip and strep flashings (length and girth as fixed) with grade of zinc coating 135.
M&L for suspended false ceiling system using 4 mm thick 'E' Board ceiling tiles classic/ designer as approved by GE of size 595mm x 595mm (as approved by GE) fixed with and including galvanized iron powder coated GI Grid system suspended from ceiling with provision of galvanized wire 4 mm dia with butterfly clips and wall taping screw i, hold down clips for fixing the board to frame complete all as per manufacturer’s instructions, complete, all as directed and specified. (a) Size of grid - 600 x 600 mm. (b) Size of main Tee – 39 x 24 (c) Size of cross Tee - 29x34 (d) Size of wall angle - 22.20 x 22.20
S&F in repair false ceiling 'E' board of size 595x595mm 4mm thick complete all as specified and directed.
M&L wall panelling made of 5 mm thick prelaminated PVC hollow section with tonge and groove joints fixed on wall with necessary screw and adhesive complete all as specified and directed by engr in charge . PVC U channel will be provied on top and bottom and PVC angle will be provided in all corners of complete al as specified and directed consisting of 5mm thick wood grain printed PVC sheet inclusive of solvant cement and fixing at site on PVC frame as per specification and drawings.
Taking down carefully existing bitumen tarfelt, including plaster of any description over the surfaces of roof, terraces including flashings and junctions of parapets/Curb walls etc and removing of the rubbish to a distance exc. 500m but n.exc. 1.00 Km and depositing where directed, complete all as specified and as directed.
M&L for Screed bed 20 mm thick in cement mortar 1:4 mixed with Water Proofing Admixture as per manufacture instructions on concrete surfaces of roof slab finishing the surfaces even and smooth complete all as specified. Note :- Water Proofing admixture shall be measured and paid separately.
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminous primer @ 0.40 Kg/Sqm conforming to IS : 3384 and applying a layer of APP based polymeric membrane not less than 3mm thick weighing not less than 3.50 Kg/Sqm, reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) and upper side of membrane thermally insulated with white gravel finish uniformly embedded during manufacturing process laid over a coat of Bitumen primer 85/25. It shall be laid by torch application having side over lap 75 mm and at the end 100 mm, all overlaps and joints shall be sealed by torch application. For parapet, membrane shall be taken to a height of minimum 60 cm and inserted inside the parapet in a groove to a depth of 65 mm. The same shall be finished by a membrane flashing. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
M&L two coat of reflective silver Aluminium paint over APP membrane complete all as specified and as directed by the Engineer-in-charge
M&L for mild steel framed work as in door frames and gauge shutters made of angle or hallow/square/rectangular/circular section and other covering door to be prepared for handing or sliding with including either hooks , proportionally made sliding door bolt , hinges or handles fittings (exclusive of steel or other covering, running rails and guides) and hanging also fastening and fixing , necessary arrangements for fixing of wiremesh, necessary bolting including welding complete conforming to FE-290 Gde E-165. Wire gauge will be measured and paid separately
S&F Mild steel black sheet 1.25mm thick fixed with Mild steel frame work for door/gates etc and necessary fixing with screwes/rivets/welding complete all as specified and directed
S & F factory made solid Wooden HDF Moulded door shutter 30mm thick (Stiles) with 2,4 or 6 raised panel design with 3mm thick Moulded Door facing sheet on front face & 3 mm thick plain colour Door Facing sheet on back face,, with raised High Density Boiling Waterproof Fiberboard skins, the core shall be consist of solid core using Machine filled Rigid Expanded Polyurethane Foam of minimum density 40kg/cum with including additional wooden blocks for fixing of locks etc. The door shall comply with and as per IS 15380 : 2003 & IS 13205 : 1991 complete, supplying and fixing in frame at site as specified and directed.
S&F 35 Factory made plain framed panel shutter of 2nd class hard wood with two panel with commercial ply wood face veneers or decorative face veneers, seasoned nd chemically treated complete all as specified and directed
S&F factory made 30mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M&L for factory made 2nd class hard wood glazed and skelton door shutter made out of stiles & rails of 30mm thick 2nd class hard wood, klin seasoned and chemically pressure treated & open rebated and prepared to receive glass/gauge etc (without sash bars), edges of framing plain, chamfered of rounded, fitted with and mitred beads for securing glass etc complete, the SIze of members of shutter shall be as per IS-1003. The shutter shall be fitted to the chowkhats as directed by Engr-in-Charge.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of pink primer complete all as specified and directed.
S&F steel window 1.25mm thick box type ERW hollow P section of size 60mm x 25mm single rebated comprise of gauged skelton shutter ERW size 50mmx20mm and 1.25 mm thick with two openable leaf consisting two Nos sash bars of T- section 20mmx3mm welded to frame with one vertical mullion of ERW box type T- section of size 60mmx25mm and 1.25 mm thick including cutting holes and making good dismantled portion with PCC (1:2:4) type B-1 (four Nos for each window)including following fittings welded to frame shutter:- (a) Hold fast 150mm long of 12mm x3mm made to shape -04 Nos per window. (b) Handle of z section 20mmx25mm, 100mm long - 01 Nos per leaf. (c) MS Tower bolt 150mm long -02 Nos per leaf. (d) Z-section 20mmx25mm 100mm long 01 Nos per leaf. (e) MS pintol hinges of size 75mmx12mm-02 Nos per leaf. Note :(i) Fabrication & fixing shall be as per TD Drawing (ii) Wire mess and painting shall be measured and paid separatly under respective items.
All as per srl item No 54.00 above but window with glazed shutter
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples to wooden/steel frames with beading complete all as specified & directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane complete all as specified and directed.
S&F frame work such as grills, grating etc with ends of bars shouldered &/or riveted or forged into spikes, framed guard bars, barred iron door ladder, frame balusters, walk ways, railing, frame work or water tanks & Similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F powder coated aluminium door anodised of approved colour( size of frame : 63.5mx38.10mmx2mm thick & size of shutter : door vertical (style ) with gasket of size 46.3mmx45.00mmx 1.50mm thick, top rail of size 47.00mmx45.00mmx1.30mm lock rail/middle rail 83.00mmx44.50mmx1.65mm thick bottom rail 114.3mmx45.00mmx1.50mm thick including S&F of 4.8 mm thick sheet glass with glazing clip, PVC track gasket, EPDM rubber gasket on glass of weather tightening alongwith recessed type handle, hinges, mortise lock, door closer complete all as specified as per TD -2004/61R sheet No 1/1
S&F Aluminium windows made of 1.59 thick powder coated (thickness of powder coating not less than 50 micron) as per aluminium section of size given below. Aluminium window will be of double shutter of glass/ wire gauge shutters including 75 mm pitch aluminium grill fixed in frame with Aluminium U channel including all necessary accessories jointing cleats , glazing clips, rubber neoprene packing, for fixing glass/ wire gauge, aluminium handles and tower bolt 2 Nos 100 mm ‘D’ Type in each door, 2 Nos 100 mm aluminium hinges including necessary steel screws complete all as specified and directed by Engr. The size of different aluminium section to be used is as under (a) Outer Frame 125X45X1.59 mm thick (b)shutter frame section size 44X44X1.59 mm thick. Note : Rates quoted are inclusive all fittings and fixtures. Glass and wire gauge will be paid separately in respective items complete all as specified and directed.
S&F in repair Door closer hydraulic regulated Aluminium (extruded section body) designation No 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed.
Repair of old existing unserviceable aluminium doors by adjusting/rescoring rubber beads, gasket beading etc complete all as directed by Engineer-in Charge
S&F in replacement 150mm floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as specified and directed
S&F 3mm thick sheet glass ordinary quality fixed with oil putty to metal frame including hacking out old broken glass (in any description) from metal frame complete all as specified and directed
S&F in repair Mortise lock of size 100mm with two levers (vertical type) mild steel body and fixed complete all as specified and directed
S&F in repair Mortise lock of size 100mm with two levers (vertical type) brass body and fixed complete all as specified and directed
S&F in repair 40mm dia cupboards knobs fixed with nut, screw and washer of mild steel bright finished complete all as specified and directed
S&F in repair hasp & staple 100mm mild steel wire type, stove enameled black, including bolt to hinge plate and fixed and screws complete all as specified and directed.
S&F in repair brass handle fabricated type of size 150mm complete all as specified and directed
S&F in repair brass sliding door bolt of size 250mm and 12mm dia with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed
M&L for repair /replacement of locking arrangement of mild steel cup board / locker / Almirah etc including necessary stainless steel handle, MS rod with complete locking arrangements and making functionable etc complete all as specified and directed
Treatment for sunken portion is as follows :- (a) Demolition of lean concrete and other type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (b) Maintain the Sunken to a slope of 1:40 outward with 32mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall. (c) Top of the sunken floor slabs shall be laid to a slope 1:40. The surface of RCC slab shall be made even and smooth by using extra cement while the concrete is still green. Concave fillet in PCC (1:2:4) type B0 of radius 75 mm shall be provided at the junctions of RCC slab and adjoining walls. (d) Floor and side walls upto the finished floor level shall be plastered with 15 mm thick CM (1:4) mixed with water proofing compound @ 3% by weight of cement. Over plastered surfaces, a layer of APP based polymeric membrane not less than 3mm thick, weighing not less than 3 kg per sqm, reinforced with polyster non- woven fabric (weighing not less than 150 gm per square metre) shall be laid by torch application. Side overlaps shall be 100mm and the ends laps shall be 150 mm and overlap joints shall also be sealed by torch application. (e) The sunken portion shall be filled with lean cement concrete (1:5:10), type E2 using 40 mm brick aggregate after carrying out satisfactory testing of CI pipes / joints and slabs / walls by filling water for 72 hours. The sunken portion of Nahani / floor trap and pipe joints shall be embedded in PCC (1:3:6) blocks. (f) 32 mm dia GI spout shall be provided to drain out leakage, if any.
Supply only integral waterproofing compound
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plan colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain finish PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisturproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65X100mm mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardanand fixed in position with MS hold fast/ugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be paid.
S&F extruted aluminum alloy with galavanised mild steel hing pin Butt hinges 100mm long
S&F Aluminum anodised, barrel tower bolts of extruded section and fixed 150 mm long
S&F extruded aluminium alloy handles 125mm size fabricated type anodized ISI marked.
S&F mild steel butt hinges medium weight colod rolled of size 100mm, ISI marked complete all as specified and directed.
S&F in repair Aluminium barel tower bolt 250mm long stove enamelled black with bright bolt & fixed.
S&F Aluminium sliding door bolt with hasp, staple (bolt type) 300mm long not less than 12mm dia with and incl minimum of 06 bolt and nuts four on bolt plate and two on staple plate complete all as specified and directed
S&F MS Casement stays, size 300mm, with hinged joint and two plates, with studs complete all as specified and directed
All as per srl item No 84.00 above but fo 250mm
Add to items 84.00 and 85.00 if fixed to steel sashes, including drilling necessary holes or welding
S & F Stainless steel Curtain rod not less than 20 mm dia with chromium plated including both sides finials and bracket fancy type fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw compete all as specified and directed.
Taking down or up steel tubing and connections including cleaning for refixing or removal to store 15mm bore complete all as specified and directed.
Supply and fixing, jointing and testing 15mm dia bore galvanised iron tube medium grade with all fittings such as bends, elbows sockets, reduces etc and fixed to wall, ceiling or laid in floor with new fittings including cutting through wall floor etc complete all as specified and directed.
Refixing old steel tubing and connection in new or old position (walls, ceiling, floor etc) bore of pipe in 15mm dia complete all as specified and directed.
S&F vitreous china squatting pan of Orrisa pattern size 580mmx440mm white with integral foot rest (excluding flushing cistern and flush pipe complete including provision of lime concrete bedding fixed in repair complete all as specified and directed.
Supply and fixing PVC flushing cistern low level 10 ltr cap with inlet ball valve float and handle syphonic action type incl brackets and flush pipe of polythene of low or high density ISI marked complete all as specified and directed.
S&F repair vitreous china wash basin white of size 550mmx400mm fixed to granite etc including 32mm dia CP brass waste coupling fitting and union complete all as specified and as directed Note: pillar tap shall be measured and paid separately complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repairs Brass chromium plated shower rose 125mm size fixed to 15mm bore pipe all as directed.
S&F Brass Chromium plated Tubular Towel rail, 20mm dia, D type, 60 cm long between flanges fixed to wall complete all as specified and directed.
S&F in repair 15mm dia stop valve/angle valve of copper alloy fancy type chromium plated screwed down high pressure with crutch or butter fly handle screwed on both ends for iron pipe or for union fixed in repair complete all as specified and directed.
S&F in repairs 15 mm bore fancy type long body bib tap, half turn, with wall flange, cast copper alloy with capstan heads, chromium plated, screwed for iron pipe or for brass ferrule, complete all as specified & as directed.
S&F high density polythelene pipe (HDPE) of 32mm, pressure rating 6 Kgf/cm2 fixed to ceiling, floor etc complete all as specified and directed.
S&F in repair 15mm dia bore cast copper alloy chromium plated fancy type pillar tap(Swan Neck) for with out cold & hot water complete all specified and as directed.
S&F 1000 Ltr capacity of rotational moulded polyethylene water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including S&F 20mm float valve 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600 mm long with fitting and including dismantling of tank complete all as specified and as directed by the Engineer-In- Charge.
S& F 500 Ltr capacity of rotational moulded polyethylene water storage tank (Cylindrical vertical with closed tap) hoisted and fixed in position including S&F 20mm float valeve 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600 mm long with fitting and including dismantling of tank complete all as specified and as directed by the Engineer-In- Charge.
S&F in repair 20mm ball valve with high pressure (PTMT) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm 210 gm complete all as specified and directed.
S&F in repairs 20mm bore Gun Metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in trenches or floors complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls with Holder bat clamps of GI flat iron 25x3 mm all as specified and directed.
S&F PVC (SWR) bends 110mm dia any radius complete all as specified and directed.
S&F PVC (SWR) junction single(Single T) equal or unequal with access door 110mm dia complete all as specified and directed.
S&F PVC(SWR) Vent cowl 110mm dia complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in trenches or floors.
S&F 75mm dia PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls with Holder bat clamps of GI flat iron 25x3 mm all as specified and directed.
S&F PVC (SWR) bends 75mm dia any radius complete all as specified and directed.
S&F PVC (SWR) junction single (Single T) equal or unequal 75mm dia complete all as specified and directed.
Supply and fix 110mm PVC (SWR) WC connector bent type all as specified and as directed.
Dismantling AC Pipe/ PVC pipes 110mm/ 75 mm dia complete all as specified and directed
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
Taking down carefully copper/aluminium point wiring of any size (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces
Taking down carefully by unscrewing from boards /outlet boxes fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, building security lights with brackets, ceiling fittigs 2x2 LED, bulk head fittings, tube light any Type, Bed Side Lights, Modular Switch Sockets, Modular Sheet Metal Flush Boxes, Fan Regulators any Type etc complete all as specified and directed by Eng-in-charge
M&L for concealed Point wiring for One Light point controlled by one, one way switch in repair with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm (FRLS) including MS shunk sheet metal box with 3 mm thick bakelite plastic laminated sheet top cover with brass counter shunk screws tith washer complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour.
All as per srl item No 121.00 but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches.
All as per srl item No 121.00 but for One 3 pin 5 amps switch socket outlet point on independent board.
All as per srl item No 121.00 but for One bell/buzzer point controlled by one bell push.
All as per srl item No 121.00 but for Two way point controlled by two way switch.
All as per srl item No 121.00 but for One ceiling/exhaust fan point controlled by one switch and regulator
All as per item Srl. No. 121.00 here in before but wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power/geyser point.
Material and labour for point wiring for One Light point controlled by one, one way switch controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC Casing & Capping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in existing/New wooden terminal box for mounting fittings like switches, sockets, regulators etc with and including new 3 mm thick phenolic laminated sheet top cover, fixed on top of terminal box complete, all as specified & directed.
All as per srl item No 128.00 but for One ceiling/exhaust fan point controlled by one switch and regulator
All as per srl item No 128.00 but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches.
All as per srl item No 128.00 but for One 3 pin 5 amps switch socket outlet point on independent board.
All as per srl item No 128.00 but for One bell/buzzer point controlled by one bell push.
All as per srl item No 128.00 but for Two way point controlled by two way switch.
All as per item Srl. No. 128.00 here in before but wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm for 15 amps power point.
M&L for concealed Point wiring for One Light point controlled by one, one way switchwith single core PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in existing conduit /Existing Casing Caping including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakelite plastic laminated sheet top cover with brass counter shunk screws with washerc complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour.
All as per srl item No 135.00 but for One ceiling/exhaust fan point controlled by one switch and regulator
All as per srl item No 135.00 but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches.
All as per srl item No 135.00 but for One 3 pin 5 amps switch socket outlet point on independent board.
All as per srl item No 135.00 but for One bell/buzzer point controlled by one bell push.
All as per srl item No 135.00 but for Two way point controlled by two way switch.
All as per item Srl. No. 135.00 here in before but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point.
S&F in repair Piano type switch single pole 1 way 5/6 amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in repair Piano type switch single pole 2 way 15/16 amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in repair Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in repair Ding Dong Bell along with bell push flush type 5 amps complete all as specified and directed by Engr-in-Charge.
S&F in repair socket two in one 6/5 Pin 5 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F in repair socket two in one 6/5 Pin 15/16 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Switch socket combination 2 in 1, 5 A, 3 Pin flush type inc taking down old onecomplete all as specified and as directed.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 inc taking down old one complete all as specified and as directed.
Supply and fix in repair Switch socket combination 2 in 1, 5 A, 3 Pin with Modular box, flush type inc taking down old onecomplete all as specified and as directed.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 with Modular box type inc taking down old one complete all as specified and as directed.
S & F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by Engr in charge.
Supply and fixing in repair Modular switch, one way 6 Amp, 1 module, piano type, 230/250 volts grade on top covers (catered in point wiring above).
All as per srl item No 153.00 but for Modular switch, two way 6 Amp, 1 module
All as per srl item No 153.00 but for Modular switch, one way 16 Amp, 1 module
All as per srl item No 153.00 but for Modular bell push 6 Amp, 1 module
Supply and fix in repair Modular socket outlet 2in1, 3pin 5A, 2 module multipurpose use, flush mounting type, 230/250 Volts grade on Top covers (catered in point wiring above).
All as per srl item No 157.00 but for Modular socket outlet 2in1, 3 pin 15 Amps flush type
S&F in repair PVC white cover plate with frame 2 Module etc complete all as specified & directed.
S&F in repair PVC white cover plate with frame 3 Module etc complete all as specified & directed.
S&F in repair PVC white cover plate with frame 4 Module etc complete all as specified & directed.
S&F in repair PVC white cover plate with frame 6 Module. etc complete all as specified & directed.
S&F in repair PVC white cover plate with frame 8 Module etc complete all as specified & directed.
S&F in repair modular metal flush box 2 Module etc complete all as specified & directed.
S&F in repair modular metal flush box 3 Module etc complete all as specified & directed.
S&F in repair modular metal flush box 4 Module etc complete all as specified & directed.
S&F in repair modular metal flush box 6 Module. etc complete all as specified & directed.
S&F in repair modular metal flush box 8 Module etc complete all as specified & directed.
S & F in repair modular fan regulator, 120W-2 Module complete all as specified and directed by Engr in charge.
Supply and fix in repair ceiling rose surface bakelite two to three terminals/plate, polycarbonate, isolated body.
Supply and fixing 2nd class hard wood rectangular block open recessed of size 45cmx30cmx5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos),for DB complete all as specified & directed.
Supply and fixing 2nd class hard wood rectangular block open recessed of size 30cmx25cmx5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos), for DB complete all as specified & directed.
Supply and fixing in repair lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified. Make- Havells,Philips,Bajaj
Supply and fixing in repair decorative ultra slim,elegant and sleek designed LED T5 batten lighting fixture with extruded aluminium housing with frosted diffuser environment friendly energy efficient sutiable for 20 watt LED tube light with 125 lumen per watt complete all as specified and directed .
supply and fix in repair LED batten (1.2m) made of CRCA sheet housing with a PC glossy diffiuser duly prewired connection having nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver .it has a rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 k CRI>80, THD<10 and PF>0.95 complete all as specified and directed Make-Philips Cat Part No. BN308C LED20S-6500 L120 PSU WH, Crompton Cat Part CIS-305-40-57-SL-DP-NWH, Havells Cat Part STOUTPLUS600BS20WLED840SPCWH
Removing and refixing decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 16W to 20W with LED tube of model E-LITE LED pride and connecting up, complete all as specified and directed.
Supply and fixing in repair LED 30 Watt ultra slim edge 2x2 feet lit panel in aluminium casing recess mounted square fixtures in white finish suitable for low ceiling height, 3 in 1 , 3K,4K,6K with & including LED prewired and connecting up dismantling of old unsv recessed mounted light. Make- Havells,Philips,Bajaj
Supply and fixing in repair surface LED luminaries 1x20 watt , 230 volts , 50Hz and new E-LITE LED TRIYCA batten a color changing LED batten and should have a minimum tempereture 6500K all in one fixtures, aal as specified and directed by Engr-in-Charge. Make- Havells,Philips,Bajaj
S&F in repair LED type security-DRACO SERIES light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete all as directed by Engr-In-Charge MAKE- Havells,Philips,Bajaj
S&F in repair 3 Watt metal and synthetic LED bedside flexible light warm white with diamension 5.5cm x 5.5cm x 14.6cm with one year manufacturer warranty. Make : Philips Cat Part No 48042 Havells and Bajaj
S&F in repair 20 Watt motion sensor batten (aluminium housing) for corridors based on auto dimming/ brightness option by motion sensor via in buildt sensor for efficient use of energy. Make : Havells Cat Part No LUNILINESMART20W LED865PCWH or Philips /Bajaj
S&F in repair inverter LED batten 20 Watt (PC body) with opal diffuser, IP-20 and inbuilt battery backup with powerful lithium battery. LED batten shall have atleast four hours backup with minimum two years warranty. The batten shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours. Make : Philips / Havells / Bajaj
S&F in repair 10 Watt emergency LED inverter bulb B-22 capacity with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours. Make : Philips /Havells /Bajaj
S&F in repair 20 Watt emergency LED inverter bulb B-22 capacity with inbuilt powerful lithium battery backup of atleast 4 hours and having minimum two years warranty. The lighting shall have deep discharge protection, fast charging, offering cool day light for atleast four hours in off hours. Make- Havells, Philips, Bajaj
Supply & fixing in repair indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1X9 watt LED Tube fitting (size within 600x25x40 mm) suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,>100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. Make- Havells,Philips,Bajaj
Supply & fix in repair surface mounted bulk head LED light fitting including 10 watt LED lamp B22 base complete with all accessories and connection complete all as specified and as directed. Make- Havells,Philips,Bajaj
Supply & fix in repair recess type, 36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge.Make- Havells,Philips,Bajaj
Supply & fix in repair recess type, 36 watt LED panel light Sky Type (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge.Make- Havells,Philips,Bajaj
Supply and fixing in repair LED light fitting as building security lights of 35 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover, incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge
Supply and fix in repair sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door.
Supply and fixing in repair 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6-32 Amp poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
All as per srl item No 191.00 but for SPN 40-63 Amp
Supply and fix in repair Vertical DB 4 way suitable for Double Pole outgoing MCB-40 Amp-04 Nos with incoming 100 Amps MCCB 4 pole-01 Nos complete with 250 Amps rated Copper busbar flush mounting, double door, proction class IP-30, IK08 complete all as specified.
Supply and fixing in repair MCB 10 to 32 Amps, single pole & neutral, 240 Volts.MAKE- havels,philips,bajaj
Supply and fixing in repair MCB 63 Amps, triple pole & neutral, 415 volts.MAKE- havels,philips,bajaj
Supply and fix in repair MCCB 100 Amps, 4 pole, 16 KA thermal and magnetic release in V TPN DB complete all as specified.
Supply and fixing in repair PVC Blanking Plates one way with internal lock complete.
Material & Labour for Sub Main Wiring in repair with two run single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. Note-Two run of 4 sq.mm & One run of 4 Sqmm & One run of PVC conduit with accessories shall be measured as One length.
Material & Labour for Sub Main Wiring in repair with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. Note - Two run of 6 sq.mm & One run of 6 Sqmm & One run of PVC conduit with accessories shall be measured as One length.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overll PVC sheathed weather proof service connections one twin core cable flat or circular of aluminium, conductors size 10 Sqmm, stranded conductors.
Identifying and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective switch/socket/ceiling rose/holders/fittings / fixtures any type, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc, complete all as specified and directed.
Identifying/detecting defects in unserviceable wiring and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective MCBs SP /SPN/DPs/TPN any type, rectification of faulty due to loose connection in electric circuits, tightening of loose connections, replacement of U/S MCBs, U/S portion of conductor etc, complete all as specified and directed. NOTE FOR ITEM NO 207.00 to 208.00 :- (a) All T & P/Stationeries and labour team required comprising of twoNos of trained electricians & helpers will be provided by the contractor daily, as directed. (b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 0900 Hrs to 1700 Hrs at the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator, air conditioning condensers and sensors etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 500/- per complaint will be penalised.
M & L for Earthing in repair complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick burried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron all as shown in electrical plate No 5 of SSR Part-I, connected to transformer / feeder pillar all as specified including GI pipe 20 mm bore medium grade for watering and 15 mm GI Pipe light grade for protection of earth lead wire, PCC chamber using PCC 1:3:6 type C-2 CI frame and cover, funnel and wiremesh, all excavation and earth work etc complete all as specified and directed by Engr-in-Charge
Material and labour for renewal of Earthing complete with GI earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included earth lead wire of dia 4 mm by means of bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg, crystal salt 200 kg ,magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1;3;6 type c1 ....for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric poer cable (heavy duty) 1100 conductor of size 25 Sq mm 4.0 Core complete all as specified and as directed by Engr-In-Charge.
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/ cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge
Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed
Supply and spreading, levelling river sand in trenches for cables cushioning on top and bottom of cable all as specifede and directed.
M&L brick protection with sub class 'B' brick laid flat across the cable complete all as specified and directed
M&L for boring under roads for crossing of UG Cables complete all as specifie and directed by Engr-In-Charge.
Supply and fix GI Pipe light grade of size 40 mm laid in trenches under road/fixed on wall/pole for cable protection complete all as specified and directed by Engr-In-Charge
GAR CONSTRUCTIONS (BID ID -3413925)
M/s ASK Enterprises (BID ID -3414372)
shiva construction (BID ID -3414359)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .