| 1 | L1₹35.0 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹35.8 L+₹76,998.75 (2.20%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being higher bidder | |
| 3 | Rejected-Technical DADAWA KURIYAR KHAS BASTI BASTI UTTAR PRADESH 272178 | BASTI | UTTAR PRADESH | 272178 | - | Rejected-Technical Document not found ok | |
| 4 | Rejected-Technical 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | - | Rejected-Technical Document not found ok | |
| 5 | Rejected-Technical | - | Rejected-Technical Document not found ok |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
31 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Tech Area Agra
GE AF Tech Area Agra
CONSTRUCTION OF NEW OPERATION ROOM AT 50 SQN AND SPECIAL REPAIR FOR REPLACEMENT OF BER AC AT AF STN AGRA UNDER GE AF TECH AREA AGRA
2022_MES_564016_2
8200-1463/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Tech Area Agra
As per NIT
9 documents required · 9 mandatory
₹500
GE AF Tech Area Agra
₹76,000
Yes
2 Mar 2023
8 Dec 2022
2 Jan 2023
8 Dec 2022
31 Dec 2022
17 Dec 2022
8 Dec 2022 - 12 Dec 2022
Amount
Excavation in trenches n.exc 1.5m wide n.exc 1.5m deep and area n.exc 10 Sqm in plan for fdn etc and getting out in Soft loose soil etc complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in fdn filling and mass concrete etc complete all as specified and directed.
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, with sub class 'B' old size built in CM 1 : 6, complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate in sub base etc complete all as specified and directed.
Material and labour for 40mm thick plain cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in floor and finishing cement concrete surface even and smooth without using extra cement etc complete all as specified and directed.
M&L light shade/coloured polished vetrified ceramic tiles 10mm thick (square/rectangular ) area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed
ditto all as per item No 06 herein before but on skirting/dado.
Returning, filling in including spreading levelling, watering and well ramming in layers n.exc 25 cm using excavated soils etc complete all as specified and directed.
Removing excavated material (soils) to a distance exc 250m but not exc 500m and depositing where directed etc complete all as specified and directed.
M&L for hardcore of gauge n.exc 63mm, broken stone deposited,spread and levelled in layers n.exc 15 cm thickness,watered and rammed to a true surface etc complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams; and similar work; all vertical or to batter to give rough finished to flat surfaces of concrete, etc complete all as specified and directed.
Use and waste of form work to sides of pillars, posts, struts, piers,columns and stanchions,square, rectangular,with rough finished concrete surface etc complete all as specified and directed.
Use and waste of form work to sides of beam and soffit of roof beams, for rough finished flat surface of concrete etc complete all as specified and directed.
Use and waste of form work to chajjas,troughs and similar items including edges, for rough finished flat surface of concrete etc complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs, floor slabs and similar work; not exceeding 200 mm thick(Horizontal or sloping) for rough finished & flat surface of concrete complete all as specified and directed.
M & L for Reinforced cement concrete M-25(Design Mix) using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
Material and labour for Reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregates as in beam, cantilevers, bressumers, lintel over 1.50 metre clear span and like etc complete all as specified and directed.
Material and labour for Reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregates as in columns, pillars, piers posts and struts etc complete all as specified and directed.
Material and labour for Reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregates as in slabs supported on walls, beams, and columns in roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
Material and labour for Mild steel TMT bars, 10 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia etc complete all as specified and directed.
Material and labour for Mild steel TMT bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including etc complete all as specified and directed.
Material and labour for 15 mm rendering in cement mortar (1:6) on fair faces of brick wall surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) mixed with water proofing compound @ 3 % by weight of cement on other than fair faces of brick wall surfaces, finished even and smooth without using extra cement etc complete all as specified and directed.
Material and labour for 10 mm rendering in cement mortar (1:3) on ceiling surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distember over a coat of alkali resistant priming paint etc complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of ceiling and applying two coats of oil emulsion distember over a coat of alkali resistant priming paint etc complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of weatherproof acrylic emulsion paint in camoflauge pattern over a coat of primer paint, includng 1mm thick wall care putty etc complete all as specified and directed.
M&L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed
M&L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed
Material and labour for 40mm thick cement concrete of type B-1, 1:2:4 (20mm graded aggregate) mixed with water proofing compound @3% by weight of cement finished even and smooth without using extra cement etc complete all as specified and directed
Material and labour for providing 20mm thick cement screed bed in CM 1:4 mixed with water proofing compound @ 3% by weight of cement etc complete all as specified and directed (Note for Sl item No 23, 31 and 32 water proofing compound shall be measured and paid separately under relevant items)
Supply only water proofing compound, ISI marked.
S&F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat rubber neoprene packing of suitable size for fixing etc complete all as specified and directed.
Supply & fix powder coated anodised aluminium two track sliding window shutters, aluminium section weighing 0.55 kg/ m including necessary jointing cleats, glazing clips, ruber neoprene packing, handles in each shutter, anodised aluminum snap beading, roller screws etc. complete all as specified and directed. (Note- Glazing shall be measured and paid separatelyunder relevant items)
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, etc complete as per requirement and direction of Engineerin-charge
Supply and fixing tinted sheet glass of thickness 5 mm area nexc 0.50 Sqm in each pane fixed to aluminum frame etc complete all as specified and directed.
Supply and fixing Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.40mm and fixed with aluminium wire staples etc complete all as specified and directed.
M & L for 18 to 20 mm thick Granite (of any type ) machine cut, as in windows cill, kitchen platform and similar work and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing etc complete all as specified and directed.
Labour only for moulding to granite/green marble stone straight or circle to facing of squared granite of any description etc complete all as specified and directed by Engr-in-charge.
S&F 19/20 mm dia stainless steel curtain rails fixed with approved decorative brackets,fancy type side knobs & stoppers etc complete all as specified and directed.
Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes forfixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in- Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shallbe accepted but no extra payment on this account shall be made.
S&F in repair venetian blends in double layers roller type of approved colour including all fitting / fixtures for fixing the same in windows complete all as specified and as directed.
S&F 595mm x 595mm size anodised aluminium snap grid frame work for false ceiling with and including 4 mm thick non asbestos fibre cement building board as in panels of approved make and design ,fixed or laid/ inserted to Aluminium framework with screws as per manufacturer's instructions complete all as specified and as directed.
Surface dressing n exc 15 cm deep in soft/loose soil including rolling and consolidating formation surface in cutting by power roller of capacity exc 8 tonne and not exc 12 tonne etc complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified and as directed
M&L 20 to 25mm thick coloured chequered tiles of approved colour, area of each tile exc 0.05 sqm but n.exc 0.09 sqm with and including 20mm thick screed bed in CM (1:6) and pointing with grey cement and pigment complete all as specified and directed.
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including PVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm, factory made and painted with stove enameled black paint in two coats with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor PVC insulated unsheathed cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed: -
One light/fan/exhaust fan point controlled by one way 5 Amp switch.
One 3 pin/5 pin socket out let 5 Amp on same board
One 3 pin/5 pin socket out let 5 Amp on independent board
All as per srl item no. 48 above but for 3/5 pin socket outlet for 15 Amps on independent board with 2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.50 sqmm PVC insulated unsheathed multi-stranded copper conductor cable as earth continuity conductor complete all as specified & directed.
S&F switch piano, flush type 5 Amp single pole one way.
S & F Socket outlet 3 pin, 5A flush type
S&/F switch piano, flush type 15 Amp single pole one way .
S&/F socket outlet multi purpose 3&5 pin 15 Amp , flush type.
S&F ceiling rose surface bakelite ISI Marked three terminal.
S&F in ceiling recessed/surface mounting 2x2 LED panel square type, slim, compact, LED edge lit panel fitting of 36 watt with opal diffuser and electronic driver etc complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified & directed.
S & F stepped type electronic fan regulator flush type 120 watt fixed on the existing phenolic laminated sheet etc. as reqd complete all as specified & directed.
S&F Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified & directed.
S&F MCB DB of sheet metal enclosure double door type, TPN 4 way with 200 Amp rated bus bar 415 Volts and grouted in walls with PCC 1:2:4 type B1 using 20mm graded stone aggregate etc complete all as specified and directed.
S & F MCB SP 5 to 32 Amps, 240V 'C' Series 10 KA etc complete all as specified and directed.
S & F MCB TPN 63 Amp 415 Volts 'C' series 10 KA complete all as specified and as directed.
M&L for earthing complete with galvaniseded steel earth plate electrode 600 x 600 x 6.0mm thick directly burried in the ground (Earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.50M below the normal ground level with and including provision of earth test point terminal block made out of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed with & including 3 Nos. 8mm dia 25mm long hexagonal head screw and necessary connections complete, connected to GI wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, protection pipe of 15mm bore GI medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, earthing pit chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick earthing pit cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS bolts & washers as required and connection from earth test point to earth electrode with same GI wire alongwith protection pipe (upto max distance of 7.5 mtr is included in unit rate) and testing on completion including takingout old u/s broken galvanised steel earthing material such as plate, pipe etccomplete all as specified and directed.
Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying of bricks best locally available sub class 'B' bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed.
M&L for local sand coushioning with dry and clean river sand over and under the cable for protection of cable , 80 mm thick sand laid before laying the cable, 150 mm thick sand laid after laying the cable complete all as specified and directed. Note : Thickness of sand will be measured after punning for payment purpose.
Supply and fixing of GI tubing 'light grade' of 50 mm bore for cable protection on pole/wall/floor/or in trenches and drain etc complete with necessary GI clamp, nut, bolts and washers and socket complete all as specified and directed.
Supply, laying, testing of cable XLPE PVC insulated, screened, PVC bedded,galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core complete all as specified and directed.
Supply and fix MCCB 63 Amp, 16KA and 4 pole complete all as specified and directed.
Supply and install 1.80 TR split Ac units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity complete all as specified and directed
Supply and fix electronic Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed
S&F Wiring for circuit/submain in PVC conduit by using FR PVC insulated copper conductor, single core cable in surface/ recessed as required 2x4.0 sq. mm +1x4.0 sq. mm earth wire complete all as specified and as directed. Note :- (i) For payment purposes PVC copper cable of 2 single core + 1 single core earthwire shall be measered as one unit. (ii) PVC conduit shall be measered and paid separately under relevant items.
Disconnecting, dismantling and taking down unserviceable window/split Ac any type / any size including disconnecting all electric connection and copper pipe and connected items etc complete from different location and deposition to MES store yard all as directed by Engineer-in-charge.
Supply and install testing and commissioning hi wall split units indoor and outdoor of capacity 1.5 TR complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 4 star rating inverter type and EER 3.2 etc complete all as specified and directed.
Supply and install window type air conditioning units of 1.5 TR capacity complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with inbuilt stablizer complete with minimum 4 star rating and EER 3.2 complete all as specified and directed.
S&F in DB enclosures with MCB protected suitable for AC including socket plug top and MCB single pole with a two pin and earth plug and socket complete 20 Amp, 240 volts including making good disturbed surfaces to match with existing surfaces etc complete all as directed. Make Havells model No DBOX x MCB Protected or equivalent of Legrand/ Indo Asian
Supply and fix 1/4” dia copper tube suitable for split ACs of capacity 1.5/ 2.0TR including cutting, jointing and soldering etc including insulation material and drainage pipe around the tube complete all as specified and directed.
Supply and fix 5/8” dia copper tube suitable for split ACs of capacity 1.5/ 2.0TR including cutting, jointing and soldering etc including insulation material and drainage pipe around the tube complete all as specified and directed.
Supply and fix 1/2” dia copper tube suitable for split ACs of capacity 1.5/ 2.0TR including cutting, jointing and soldering etc including insulation material and drainage pipe around the tube complete all as specified and directed.
Supply and fix Outdoor unit stand of split AC capacity compete all as specified and directed.
M&L of PVC insulated unsheathed FRLS copper cable 2.5 sqmm 4 core multi stranded copper cable compete all as specified and directed.
GUPTA ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .