| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹21.8 L+₹49,672.80 (2.33%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹22.8 L+₹1.5 L (7.10%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹23.4 L+₹2.1 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹25.2 L+₹3.9 L (18.5%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
19 Nov 2022, 6:55 pmClosed
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
REPAIR/MAINT OF DG SETS AMF PANELS, REPLACEMENT OF BATTERY AND CHARGER HOT AND EOT AT COD CHHEOKI AND ALL STREET LIGHT AND SECURITY LIGHT OF DAD AT NEW CANTT ALLAHABAD
2022_MES_559509_1
8602/E8
Open Tender
Civil Works
Item Rate
270 days
NEW CANTT ALLAHABAD
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹90,000
Yes
14 Dec 2022
22 Oct 2022
21 Nov 2022
22 Oct 2022
19 Nov 2022
5 Nov 2022
Amount
Labour for cutting/pruning of tree branches along seccurity light pole around 2 mtr radius of security light fitting and removing from site including arrangement of T&P (i.e Axe , rope & ladder etc ) complete all as specified and directed.
Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying (in repair) cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul bothe end of cable and testing complete all as directed for following size :- [Note for item No.2. -Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately]
(a) 4 Sqmm 2 core
(b) 6 Sqmm 2 core
(c) 10 Sqmm 2 core
(d) 10 Sqmm 4 core
(e) 16 Sqmm 4 core
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out for electric cable complete in any type of soil complete Note :-For the digging of soil , JCB machine will not be allow at site, it will be done by labour only and contractor will be responsibleto repair the existing cable , pcc plinth etc without extra cost which will be damaged during execution of wk.
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed.
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
M & L for sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified and directed.
M&L for boring under road horizontely of size 40/50 mm bore using GI pipe for passing of cable in road/path in hard/soft/ loose soil complete all as specified and directed.
M&L (in replacement) for 40 mm bore GI tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor / as garden post including 2 Nos mild steel FI clamps 35x3 mm size to support pipe with pole complete all as specified and directed.
S&F( in replacement) Pole box junction three phase of size 297x 250 x 130 mm, made of 2 mm MS sheet factory painted with synthetic enamel paint, and inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fix on epoxy insulated support and MCB 6 Amp 10 kA 240 volt complete all as specified and directed.
Street light repair -
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings any type for repair or replacement of burnt/worn out accessories or carrying to MES store (Accessories or components to be provided free for replacement by department) complete all as directed by Engr-in-charge.
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak HPSV lamp 150 watt and re- fixing the fitting in position after repair and testing complete.
M& L for repairing of unserviceable street lightT-5 fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak T 5 tube rod 24 watt and re- fixing the fitting in position after repair and testing complete.
M&L for repair of Bldg security light by replacement of worn out/old linear fluorescent tube of 36 watt with energy efficient/ saving retrofit LED tube of nominal wattage-18 watt , having lumen out put 2100 lumen or above, colour temperature 6500kelvin, size & length- G13/ T8/4 feet operating voltage 140 to 280 volt AC THD -15 % , with integral /inbuilt driver and having short circuit and surge protection including minor addition/ alteration in existing circuit as required complete all as specified and directed.Phillips / Havells/CG/wipro or havells as approved.
M& L for repairing of unserviceable bldg security light fittings by replacement of worn out 36 watt FPL with linear LED PLL lamp with extruded plasting body and PC diffuser complete with inbuilt driver of high efficacy of system wattage 18 watt length 419 mm lumen out put 1800 lm or above, colour temp 6500 K suitable for existing 2G11 lamp holders including minor alteration in existing ckt as required. Make- Crompton/wipro/Bajaj/ havells/phillips.
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak copper ballast 150 watt and re- fixing the fitting in position after repair and testing complete.
M& L for repairing of unserviceable street lightT-5 fittings (fixed on pole) of any type/make by replacing burn out/ worn-out/ weak Electronic ballast 2x24 watt and re- fixing the fitting in position after repair and testing complete.
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak bi-pin holder for T-5 fittng and re- fixing the fitting in position after repair and testing complete.
M& L for repairing of unserviceable street light (fixed on pole) of any type/make by replacing burn out/worn-out/ weak holder for HPSV/MH fitting (70-400 watt) and re-fixing the fitting in position after repair and testing complete.
M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 9/11 watt and re- fixing the fitting in position after repair and testing complete. Make Phillips
M& L for repairing of unserviceable Gate light of any type/make by replacing burn out/worn-out/ weak LED lamp 25 watt and re- fixing the fitting in position after repair and testing complete.
M&L for repairing of unserviceable LED street light any make /model of 70-90 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 277 Volt 50/60 Hz AC supply complete all as specified and directed. Driver make Phillips/ havells/wipro/CG or as approved.
Note for item No 11 to .23 (i) Make of item No. 12 to 23 : philips/bajaj/Crompton/havells (ii)contractor will mark a identity (i.e CA No . or Firm Name) ,using permanent paint marker pen on each component which will be replace under repair of street light and he will be liable to change his new replaced items without any extra cost which become unserviceable due to any reason, during execution period of CA and further upto defect liability period. it will be contractor responsibility to take the location of unvs street/garden/post top/ search light fittings by MES rep at 9 AM at Power house in every working day.
S&F (in replacement) Contactor 3 phase 40 amps for street light timer (Make- L&T type MNX25 or equivalent as approved) in existing panel/ location and connection incl necessary alteration in panel/ door as required for proper fixing &connection complete all as specified and directed.
S&F inreplacement of PVC insulated PVC sheathed stranded copper conductor cable 2.5 Sqmm two core complete all as specified and directed. Make
S&F rigid PVC conduite 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp , nut bolt and complete all as specified and directed.
Supply, fixing, connecting, & testing LED streetlight fitting of 90 Watt high pressure die cast aluminium housing, with minimum 125 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm &pvc copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Note : The contractor has to submit 05 Years gurantee on Rs 10/- stamped paper and 2.5 % of the cost quoted cost of the fittings shall be retained from the contractor dues. However the contractor may furnished FDR of suitable amount against the gurantee money.
Supply, fixing, connecting, & testing LED streetlight fitting of 70 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm &pvc copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Note : The contractor has to submit 05 Years gurantee on Rs 10/- stamped paper and 2.5 % of the cost quoted cost of the fittings shall be retained from the contractor dues. However the contractor may furnished FDR of suitable amount against the gurantee money.
Supply, fixing, connecting, & testing LED Flood light fitting of 100 Watt high pressure die cast aluminium housing, with minimum 110 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm &pvc copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Note : The contractor has to submit 05 Years gurantee on Rs 10/- stamped paper and 2.5 % of the cost quoted cost of the fittings shall be retained from the contractor dues. However the contractor may furnished FDR of suitable amount against the gurantee money.
Supply, fixing, connecting, & testing LED streetlight fitting of 35 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and s&f PVC conduit 20 mm &pvc copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Note : The contractor has to submit 05 Years gurantee on Rs 10/- stamped paper and 2.5 % of the cost quoted cost of the fittings shall be retained from the contractor dues. However the contractor may furnished FDR of suitable amount against the gurantee money.
M&L for poles painting with applying two coats of aluminium colour synthetic enamel paint incl preparation of surfaces to perimeter light stand 2.5 mtr long 40 mm GI pipe and applying two coats of black bitumenous paint over the embeded portion of pole complete all as directed.
M&L for replacement of Lamp holder of post top latern fitting of model No. Athena2 Code No. LHDC12115099
S&F( in replacement) Pole box three phase of size 297x 250 x 130 mm made out of 2 mm MS sheet factory made with inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fixe on epoxy insulated pole and MCB 6 Amp 10 kA 240 volt complete all as specified and directed.
S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete
S&F MS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.0 mtr, fixed to pole/ earth and grout using PCC & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer complete
Supply & fixing of automatic street light switch using infrared sensor based on nature switch for automatic switching of street lights. Nature switch operation should be based on nature light lux level. Required illumination level for switching ON is <30 lux and for switching OFF >10 lux.The nature switch along with suitable power contactors , incoming and outgoing MCBs should be enclosed in a pole/ wall mountable enclosure make of rust proof , electric shock proof and FR grade SMC junction box confirming to IP 54 complete all as specified for the following: -
(a) Suitable of three phase load of 5 kw with contactors (single phase 3Nos), incoming & Outgoing MCB SP (6 Nos),rating of 20-25 Amp & circuit wiring of min 10 sqmm. Make -Swadeep Cat No. swadeep -02EC 5kw3P or equivalent in siemens /Indoasian
(b) Suitable of single phase load of 2 kw with contactor (single phase 1Nos), incoming & Outgoing MCB SP (6 Nos),rating of 20-25 Amp & circuit wiring of min 10 sqmm. Make -Swadeep/siemens /Indoasian or as approved.
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak MH lamp 250 watt and re- fixing the fitting in position after repair and testing complete.
M& L for repairing of unserviceable street light fittings (fixed on pole) of any type/make by replacing burn out/worn-out/ weak MH lamp 150 watt and re- fixing the fitting in position after repair and testing complete.
S&F MCB DB SPN 2 way double door type , comprising of one MCB SPN 16 Amp 'B' series 415 volt incl fixing of DB on pole/ wall with suitable arrangement for the garden light incl making wall surface smooth as existing using plastering and white wash complete all as specified and directed.
S&F (in replacement) Contactor 3 phase 25 amps for street light timer (Make- L&T type MNX25 or equivalent as approved) in existing panel/ location and connection incl necessary alteration in panel/ door as required for proper fixing &connection complete all as specified and directed.
M&L for repairing of unserviceable LED street light any make /model of 20-35 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt 50/60 Hz AC supply complete all as specified and directed. Driver make Phillips/ havells/wipro/CG or as approved.
Section 'A' (DG Set)
M&L periodical servicing of diesel engine driven Gen set 3 phase 415 volts 50 c/s AC supply by cleaning thoroughly and replacing fuel filters ,air filters, oil filters draining out engine oil etc. and replacing with new oil, tightening of all gaskets , connection of battery terminals, electric cable connections foundation bolts, coupling bolts etc including test running and tappet setting of alternator by checking and setting of voltage and frequency all as directed by Engr-in-charge. MAKE OF DG SET : Kirloskar/ Crompton greaves/Cummins. Make of filters : kirloskar/CG/Fleet guard/MICO Note:Engine oil, Fuel filters, Air filters, oil filters replaced will be measured and paid separately under respective item of sch 'A' . for following capacities of DG set
320 KVA DG SET
225 KVA DG SET
63/62.5 KVA DG SET
Supply and fixing in replacement of maintenance free battery with initially charged capacity 180 AH , 12 Volt complete all as specified and as directed. Make :- Exide/Amron
Supply and fixing in replacement of maintenance free battery with initially charged capacity 150 AH , 12 Volt complete all as specified and as directed. Make :- Exide/Amron
Supply and fixing in replacement of maintenance free battery with initially charged capacity 90 AH , 12 Volt complete all as specified and as directed make :- Exide/Amron
Supply, fixing & testing in replacement of Radiator of 320 KVA DG Set water cooled of kirlokar make withcopper tubings including replacement of connected items such as inlet & outlet rubber hoses & all other connected items
Supply, fixing & testing in replacement of Radiator of 62.5 /100 KVA DG Set water cooled of kirlokar make withcopper tubings including replacement of connected items such as inlet & outlet rubber hoses & all other connected items
M&L for replacement of UNSV radiator hose pipe set complete as per sample of DG set of following capacity
320 KVA DG SET
225 KVA DG SET
63/62.5 KVA DG SET
M & L for replacement of UNSV fan belts as per sample for DG sets of following capacity. MAKE: Fenner/ Grip/ Dunlop
Fan belt for 320 KVA DG Set
Fan belt for 225 KVA DG Set
Fan belt for 63/62.5 KVA DG Set
M&L in replacement of stranded copper conductor battery lead for 24 volts DC grade red for (+)ve terminal and black for (-)ve terminal fitted with battery terminal at one end & battery lug at other end complete length 1.5 mtr.
M & L for cleaning of radiator by cleaning agent/Radiwash (make:fleetguard/coolguard) including removal/ dismantling of radiator from engine transporting to work shop or cleaned at site , soldering / brazing,testing for any leakage , remounting to its original position as per entire satisfaction of Engr - in-charge for following capacity of DG Set.
DG Set 320 KVA DG Set
DG Set 200/250 KVA DG Set
DG Set 63/62.5 KVA DG Set
M & L for replacement of set of hose clips for DG sets of following capacity
DG Set 320 KVA DG Set
DG Set 225 KVA DG Set
DG Set 63/62.5 KVA DG Set
M&L for coolant radicool SFO premix of Castrol or equivalent of Shell/volvoline
M&L to drain out the old used engine oil from sump of DG sets& cleaning & refilling with new engine oil 15 W 40 up to required level including topup Make : Castrol/ HP or equivalent of shell
M&L for replacement of defective self starter assembly by new self starter assembly 12/24 volts make: lucas / Bosch
-ditto – all as per item No. 65 above but alternator assembly
M&L in for replacement of PCB card Procom R E L-7-1.0 for 225/63.5 KVA AMF pannel
M&L in for replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ make YOI/ Siemens for 160/100 KVA AMF pannel
M&L in for replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ make YOI/ Siemens for 62.5/40 KVA AMF pannel
M&L in for replacement of timer switch 0 to 80 seconds Make Siemens for 160/100 KVA AMF pannel
M&L for servicing of DG set 320 KVA AMF panel,setting of time delay switch ,tightening of all electrical incoming & outgoing connections including replacement of cable lugs& adjustment of solenoid switches& Relays
M&L for servicing of DG set 225KVA AMF panel,setting of time delay switch ,tightening of all electrical incoming & outgoing connections including replacement of cable lugs& adjustment of solenoid switches& Relays
M&L for servicing of DG set 62.5/40 KVA AMF panel,setting of time delay switch ,tightening of all electrical incoming & outgoing connections including replacement of cable lugs& adjustment of solenoid switches& Relays
M & L for painting of Generating set of capacity 225 KVA to 320 KVA complete in existing colour with two coat of synthetic enamelled paint by spray machine over one coat of primer after preparation of surfaces installed at Hisar Mil Stn complete all as specified and as directed.
M & L for painting of Generating set of capacity 7.5 KVA to 62.5 KVA complete in existing colour with two coat of synthetic enamelled paint with spray machine over one coat of primer after preparation of surfaces installed at western & eastern pocket drainage pump House complete all as specified and as directed.
Supply and replacing in repair Onload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 100 Amps, 415 Volts complete all as specified and directed.
Supply and replacing in repair Onload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 200 Amps,415 Volts complete all as specified and directed.
Supply and replacing in repair Onload four pole change over with advance Neutral On load change over switch I-O-II ,Current Rating 400 Amps, 415 Volts complete all as specified and directed.
Supply only Diesel Filter suitable for 62.5 KVA to 100 KVA DG set Make - Kirloskar/CG/KG/Cummins
Supply only Diesel Filter suitable for 200 KVA to 320 KVA DG set Make - Kirloskar/CG/KG/Cummins
Supply only Lub Oil filter suitable for 62.5 KVA to 100 KVA DG set Make - Kirloskar/CG/KG/Cummins
Supply only Lub Oil Filter suitable for 200 KVA to 320 KVA DG set Make - Kirloskar/CG/KG/Cummins
Supply only Air filter suitable for 62.5 KVA to 100 KVA DG set Make - Kirloskar/CG/KG/Cummins
Supply only Air Filter suitable for 200 KVA to 320 KVA DG set Make - Kirloskar/CG/KG/Cummins
Supply & fixing spare parts & accessories of original make for repair of DG set under serial items No 1(i) to 1(iii) here-in-before all as directed by Engr-in-Charge :- 01 Nos DG sets Notes :- All spares & accessories shall be fixed in the DG set only after prior inspection & Approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M New Cantt
Kit Fuel filter
Kit Lub oil filter
Kit bypass filter
Kit Air cleaner
Air filter
Upper Gasket set (Cylinder head)
Valve exhaust
Valve inlet
Valve seat Exhaust
Valve seat Inlet
Guide valve
Collet Volve
Spring valve
Kit turbo charging
Collar thrust
Kit injector
Kit Piston and ring set
Kit Cylinder liner
Kit Sump Gasket
Gear pump assembly (Fuel pump FIP)
Weight & carrier
Barrel sleave
Gasket Set
Sexen filter
Governor Pressure valve (Hydraulic Governor)
Gear assembly
Ball bering
Head gasket
Nozzle
Block
Liner
Battery terminal
Packing Kit
Crank
Main bearing
CR bearing
Came bush
Connecting Rod
Rod balancing
Third washer
Valve seal
Dismantling of DG Set Alternator of cap 225 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as direted.-01 Nos
Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete.
Repairing of armature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete.
Supply and replacing Ball bearing at DE (Driven End) side of No.6310 Make-NBC/SKF-01 No
Supply and replacing rectifier Diod.
Supply and replacing AVR (Automatic Voltage Regulaotr).
Supply and replacing connetion plate of suitable size.
Dismantling of DG Set Alternator of cap 320 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as direted.-02Nos
Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete.
Repairing of armature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete.
Supply and replacing Ball bearing at DE (Driven End) side of No.6310 /6311/6312/6314 Make-NBC/SKF-01 No
Supply and replacing rectifier Diod.
Supply and replacing AVR (Automatic Voltage Regulaotr).
Supply and replacing connetion plate of suitable size.
Dismantling of DG Set Alternator of cap 62.5 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as direted.-02 Nos
Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, Grease etc complete.
Repairing of armature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete.
Supply and replacing Ball bearing at DE (Driven End) side of No.6310 /6311/6312/6314 Make-NBC/SKF-01 No
Supply and replacing rectifier Diod.
Supply and replacing AVR (Automatic Voltage Regulaotr).
Supply and replacing connetion plate of suitable size.
Supply and fixing (in repair) MCCB 100 Amps, 415 Volts, 4 Pole, breaking capacity 16/25 KA, ISI Marked, Fix type, Make- C&S/ L&T/Indo-Asian/Havells
Supply and fixing (in repair) MCCB 200 Amps, 415 Volts, 4 Pole, breaking capacity 25KA, ISI Marked, Fix/ Adjustable type, Make- C&S/ L&T/Indo-Asian/Havells
M&L for repair/overhauling of existing starter panel board of any size/type including cleaning with compressed air tightening of all electric connections to switces including repair/replacment of existing MCB/ switch fuse disconnector units each of any rating including testing complete with fixing of door (front & backside) with proper fixing & locking arrangement replacement of wornout lugs, nut, bolts, internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire and llugs, proper connention to main earth lead, to be provided/replaced as required at cable entries, fixing of door front & back with copper locking arrangement as requred as site and painting with spary machine with super eanameled paint light grey paint in outer/ inner side of pannel after cleaning and prepaing surface including sign writing complete all as spcified and directed Note : spares part to be repalaced shall be measured and paid sparately as supply only
(a). Supply only TF 34 make siemns or equivalent approved
(b). Supply only Contactor TF 30 Make Siemens or equivalents approved
(c). Supply only Contactor TF 31 Make Siemens or equivalents approved
(d). Supply only PVC Connector
(e). Supply only Over Load Relay capacity 20-30 amp Make Siemens or equivalents approved
(f). Supply only Over Load Relay capacity 10-20 Make Siemens or equivalents approved
(g). Supply only MCB TPN 63 amps 'C' series 415 Volt
(h). Supply only MCB TPN 32 amps 'C' series 415 Volt
S & F in replacement of Exhaust silencer complete with muffler of 100 KVA/62.5 KVA DG set complete connects engine and DG silencer to drive away hot gases generated during operation of DG to atmosphere through silencer complete.
Dismantling and taking out the self starter,12 Volt DC fitted in 15 to 62.5 KVA 3 phase 50 HZ of DG sets and strip opening of Self starter 12 Volt DC for carrying out repair/ servicing /overhauling mechanically ,cleaning, oiling/greasing/varnishing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts, complete and re-assembling of Self starter 12 Volt DC after repair/ servicing /overhauling and fixing the same in position and testing complete all as specified and directed . Notes :- (i) Repairs/servicing / reassembling and testing of Self starter 12 Volt DC shall be carried out through a authorised service center .(ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
Supply only the following items/spare parts suitable for self starter, 12 Volt DC fitted in 15 KVA to 62.5 KVA 3 phase 50 HZ of DG set , dismantled/fixed under Sch `A` item No 43 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 16 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
(a). Solenoid switch suitable for self starter, 12 Volt DC
(b). Commutator suitable for self starter, 12 Volt DC
(c). Carbon brush suitable for self starter, 12 Volt DC
(d). Field coils suitable for self starter, 12 Volt DC
(e). Bendix pinion assembly suitable for self starter, 12 Volt DC
(f). Bushe suitable for self starter, 12 Volt DC
Supply & fixing of micro processer start/stop control PCB panel for 250/100/62.5 KVA DG set by taking out unserviceable relay complete with following parameters Make: Kirlosker/ Greaves /Cummins (a) Individual phase current (Amps) (b) Phase voltages (V) (c ) Generator output frequency (Hz) (d) Engine water temperature (Deg.C) (e) Lube oil pressure (kpa) (f) Working hours (g) Push button (Starter) & (stop) (h) LED indications for main function
Material & labour for replacement of unserveceable interconnection wiring and its interlocking system in AMF electric control panel for DG set with using and including PVC insulated and unsheathed stranded copper conductor cable, single core, minimum 1.5 Sqmm size or as required 1100 Volts grade cable for making functional controls of the DG set, auxiliary contactor, push buttons, indicator, amps meter, volt meter complete as required at site for functioning of DG set in auto and manual mode, checking AC/DC circuits and removing & replacement of defective / unserviceable parts with new parts, complete all as specified and directed . Notes : (i) The complete panel shall be checked and tested on full load after necessary repairs and replacement of unserviceable wiring. for its smooth functioning and proper interlocking including shutt down on high water tempreture and low Oil pressure. (ii) All control wires shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of copper lugs. the cost of same are deemed to include under these items. (iii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, shim, small springs, screws/gaskets/ packing /studs etc.
Supply only the following items/spare parts suitable for AMF pannel of DG set , dismantled/fixed under Sch `A` item No 46 here in above complete all as specified and directed. Note :- (i) Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 46 here in above. (ii) Contractor shall have no claim on account of variation of quantities of any item or non execution of any item.
(a). Electronic timer,on delay type, dual range, suitable of 220 Volts/ 24 Volts, 2NO+2NC, 50 Hz, AC supply/ DC supply , for 0-60 seconds .
(b). Power contactor 3 pole with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 300/325/330 Amps. Complete all as specified and directed .
(c). Power contactor 3 pole with 2NO + 2NC auxiliary contacts, coil voltage 220 volts, AC 3 rating 400 Amps. Complete all as specified and directed .
(d). Power Contactor No volt coil suitable for 400Amp Contactor
(e). Power Contactor No volt coil suitable for 300/325/330 Amp Contactor
(f). Auxilliary relay 8 pin, 24 Volts ,DC , 2 change over.
(g). Auxilliary relay 8 pin, 220 Volts , AC , 2 change over.
(h). Bimetal under volt / over volt relay suitable for 3 phase, 3 wire with 2 NO+2NC auxiliary contacts
(j). Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply.
(m). Indicating lamps LED type with holder for 12 / 24 volts DC supply
(o). Digital electronic volt meter 0-50 V range suitable for 12 / 24 volt DC supply panel flush pattern square type size 96mmX96mm
(p). Digital electronic volt meter 0-500 V range suitable for 415 Volts panel flush pattern square type size 96mmX96mm
(r). HRC fuse DIN type with base for AC circuit 415 volts having rating of 400 Amps .
M & L for Cleaning of MS fuel tank of DG sets of 100 to 300 ltr capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
S & F in replacement of Exhaust silencer complete with muffler of 320 /100 KVA/62.5 KVA DG set complete connects engine and DG silencer to drive away hot gases generated during operation of DG to atmosphere through silencer complete.
Supply & fixing in replacement of Amp meter, digital type Make: AE/Rishabh
Supply and fixing in replacement of Volt meter , digital type Make: AE/ Rishabh
S&F in replacement of AC spare coil 240/415V for contactor 50 to 100 Amps capacity complete Make: Havells/ L&T/ HPL
S&F in replacement of AC spare coil 240/415V for contactor 125 to 185 Amps capacity complete Make: Havells /L&T /HPL
S & F in replacement of SMF battery 12 volt 17 AH complete as directed..Make: Exide/Amron
S & F in replacement of SMF battery 7 volt 10 AH complete as directed..Make: Exide/Amron
Supply and Fixing in replacemnet Power contractor MCX 44 for AMF Panel as specified and directed . Make L&T
Supply and Fixing in replacemnet Power contractor MCX 40 for AMF Panel as specified and directed . Make L&T
Supply and fixing under voltage relay 415 volts for AMF panel as specified and directed .
Section 'B' (Cranes)
S&F in replacement of DOL starter three phase,415 volt suitable for upto 5HP motor as specified and directed
S&F ( in replacement ) of flame proof suspension type pendent / hanging controlling unit with flame proof star/ stop push buttons with indicator lamp and emergency control remote , lifting hock for UP and DOWN , long travel motion ,cross travel and connoting to controlling micro speed panel suitable for safe and smooth operating system of EOT crane of 2 Tons capacity including making cable connection and testing complete all as specified and directed in presence of Engre-in-charge make BCH or equivalent model and make
S&F ( in replacement ) of flame proof suspension type pendent / hanging controlling unit with flame proof star/ stop push buttons with indicator lamp and emergency control remote , lifting hock for UP and DOWN , long travel motion ,cross travel and connoting to controlling micro speed panel suitable for safe and smooth operating system of EOT crane of 10 Tons to 20 tons capacity including making cable connection and testing complete all as specified and directed in presence of Engre-in-charge make BCH or equivalent model and make
S&F MCCB fixed thermal and fixed magnetic setting type of capacity 400 amps , 4 pole of breaking capacity icu 36kA,415 volts AC 50Hz as per including fitted with suitable sixe of alluminum lugs complete and taking down of existing MCCBs all as specified and directed Make- Havells , L&T , ABB or Equivalent model and make
S&F MCCB fixed thermal and fixed magnetic setting type of capacity 315 amps , 4 pole of breaking capacity icu 36kA,415 volts AC 50Hz as per including fitted with suitable sixe of alluminum lugs complete and taking down of existing MCCBs all as specified and directed Make- Havells , L&T , ABB or Equivalent model and make
S&F main switch DP switch HRC type of capacity 400 amps , 4 pole in metal 415 volts AC 50Hz as per including fitted with suitable sixe of alluminum lugs complete and taking down of existing Main switch all as specified and directed Make- Havells , L&T , ABB or Equivalent model and make
S&F in replacement of unserviceable main gear box oil seal packing ,gear box ball bearing etc or other defected connecting parts as required at site sample /type and making it oil lask proof and sound less proof complete and including testing on load of 2 ton EOT crane complete all as specified and directed .
S&F in replacement of unserviceable main gear box oil seal packing ,gear box ball bearing etc or other defected connecting parts as required at site sample /type and making it oil lask proof and sound less proof complete and including testing on load of 10 ton to 20 tons EOT crane complete all as specified and directed .
M&L for servicing of over head crane complete including cheking / tighting of nuts , bolts and brakes complete system ,adjusting of breaks motions and VFD adjustment setting as per load testing run of flame proof / non flame proof / normal type EOT/ HOT cranes with having single or double girder type and providing greasing & oiling of travelling / moving parts of cranes with connecting motor girder parts for movement of cranes hoist / long /cross travelling and including maintained the controlling of speed /creeping micro speed of motors with minor maint/repair the electrically operated main contro panel wire with connecting control wiring system consisting of main swith ,step down transformer, contractor ,HRC fuse , VFD, PLR ,control pendent , wire rope with break drum unit , gear box unit ,oil levels , motor bed / foot, electrical control cable , motor terminal, end cable carriage trolly , motor shaft , bush flange bearing with lathe work , chain pully block , racket cluch ,gear block , chain wheel ,chain etc and including locating the defected fault and rectification of the fault and rectification of oil leakage etc any type and size and replacement of defected nut, bolts& washer andmaking it sound less proof and after trails testing run complete all as specified in present of Engr-in- charge Note:- (i) servicing , adjusting etc of breaks motions and testing run work will be carried out by well qualitied technician having good experience in the about reparing field of EOT cranes (ii) It is personally responsibly / liability of contractor for smooth function of cranes for 06 month after the handing /taking over the all site without any extra cost to department (iii) contractor shall beimmediately depute suitable nos of trademan to attend the complaints on required basis for found unserviceable of crane with in the effected time after launching of complaints or all as specified and directed by Engre-in-charge
EOT crane of capacity 20 tons
EOT crane of capacity 2 tons
EOT crane of capacity 10 tons
S &F Limit switch for crane from 10 tons to 20 ton
S&F Crane operating Push button Remote 2 tons to 20 tons
S&F in replacement of hydraulic brake 0.5HP 415V alongwith connecting fixing accessories as per existing sample / model suitable for break system of 2 Tons EOT cranes complete specified and directed by Engre-in-charge
S&F in replacement of hydraulic brake 1HP 415V alongwith connecting fixing accessories as per existing sample / model suitable for break system of 10 Tons to 20 tons EOT cranes complete specified and directed by Engre-in-charge
Material and Labour for taking down of unserviceable motor motor from Over Head Cranes and including transporting and rewinding electric motor of capacity upto 2 HP ,3 phase 415 volts ,with supper enameled copper conductor wire as per existing sixe/gauge including making vanishing drying and connecting fixing accessories etc including refixing on same position and testing on load complete all as specified and directed in presence of Engre-in-charge
Material and Labour for taking down of unserviceable motor motor from Over Head Cranes and including transporting and rewinding electric motor of capacity upto 5 HP ,3 phase 415 volts ,with supper enameled copper conductor wire as per existing sixe/gauge including making vanishing drying and connecting fixing accessories etc including refixing on same position and testing on load complete all as specified and directed in presence of Engre-in-charge
Material and Labour for Rail repair of cranes 10 to 20 tons making smooth for functional , cleaning dust, welding works complete all as specified and directed in presence of Engre-in-charge
S& F in replacement of FRLS PVC insulated electric cable with multi standed copper conductor cable with having of single 4 core of 10 sqmm ,1100 volts grade and making cable connection complete all as specified and directed Make : Havells or equivalent to this make
S& F in replacement of FRLS PVC insulated electric cable with multi standed copper conductor cable with having of single 4 core of 6 sqmm ,1100 volts grade and making cable connection complete all as specified and directed Make : Havells or equivalent to this make
S& F in replacement of FRLS PVC insulated electric cable with multi standed copper conductor wire with having of single 2 core of 2.5 sqmm ,1100 volts grade and making cable connection complete all as specified and directed Make : Havells or equivalent to this make
Supply of spare parts required for maintenance of EOT Crane of various capacities:-
Supply and Fixing in replacemnet Power contractor MNX -110 for EOT Crane Make:- L&T
Supply and Fixing in replacemnet Power contractor MNX 95 for EOT Crane Make :- L&T
Supply and Fixing in replacemnet Power contractor MNX 32 for EOT Crane Make :- L&T
Supply and Fixing in replacemnet Power contractor MNX 22 for EOT Crane Make :-L&T
Supply and Fixing in replacemnet Power contractor MNX 18 for EOT Crane Make :-L&T
Supply and fixing in replacement over relay 415 Volts
Supply and fixing in replacement Athekatic bearing VC 210 for HOT Crane Make NBC
Supply and fixing in replacement Athekatic bearing VC 205 for HOT Crane Make NBC
Supply and fixing in replacement Electric Hose 10/20 Ton Capacity 415 Volts
Supply and fixing in replacement AC drive ( inventer ) 10/20 HP 415 Volts
Supply and fixing in replacement PT coil 415 Volt
Section 'C' (Swimming Pool)
Quarterly Periodical, preventive and comprehensive maintenance by dis-assembly, repairing, overhauling, servicing, connection & testing complete of following equipments all as specified & directed :-
(a) Suction sweeper machine with motor and trolly
(b) Induction motor 20 HP capacity including pump
M & L for Opening the filter tank of swimming pool plant and taking out old sand and carbon media including cleaning/ washing complete all as directed. NOTE: Sand and carbon media measured and paid seperately in relevent item.
Supply transporting filling in TTCA 95% granuals in 45 Kg container omplete all as directed by Engr-in-Charge.
Supply transporting filling copper sulphate granuals in 25 Kg bag complete all as directed by Engr-in-Charge.
Testing of Chemical & Bacteriological quality of inlet (Raw Water) and out let (treated water) sewage water of following parameters: (i) PH value (ii) Suspended solids (iii) Total dissolved solids (iv) C.O.D (v) BOD (vi) Oil & Grease
S&F in replacement 150mm bore S G iron body Wafer type check valves/ non returning valve,, with nuts, bolts and washers including 3mm thick rubber gasket joint complete all as specified and directed.
S&F 150mm bore sluice valve, heavy duty both ends flanged class PN-I with high tensile brass spindle cast iron head operated wheel and cap top, nuts and bolts, washers including 3mm thick rubber gasket joint including taking down old unserviceable valve complete all as specified and directed.
S&F in replacement horizental type Submersible cable 4 sqmm 3 core 230 Volts including connection lugs with pumps complete all as specified and directed. Make: KSB/ L&T/ Crompton.
M&L for pea Gravel in filtration plant of swimming pool and change with old gravel as complete all as specified and directed
Supply, installation, testing and commissioning in replacement of indoor type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3.15 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate ) (i) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 100 Amp - 01 No (iii) Star delta starter comprising suitable size of 3 pole contactors for 10 HP submersible pump with thermal over load relay complete - 01 No (iv) Motor protection relay for single phase, over load, over voltage (v) Digital Volt meter 0-500 volts (vi) Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set (ix) MCCB' TP 32 Amps 16 KA - 02 No (x) MCB SPN 32 Amps 10 KA - 02 No (xi) Single phase preventer - 01 No Make of MCCB, MCB & Contactor: L&T, Hagger, Siemens,
Section 'D' (Sewage Pump)
Taking out/dismantling non clog sewage pump unit 20 HP capacity and overhauling,oiling & greasing including replacement of worn out bolt&washer, grinding&polishing if required complete Note: spares impellar, bush &oil seal will be measured and paid separately
Supply only spares for repair to pumps of following capacity:-
Non cloging heavy impeller for 20HP
Bush for 20HP
Oil seal for 20HP
Repair/Overhauling / unserviceable nonc clog sewage pump induding electric motor 20 HP, 3 phase, 415 Volts,disconnecting the electric connection and dismantling the motor. Cutting the burnt winding and cleaning the slots with non greasy materials and rewinding with PVC insulated copper wire as per existing size with insulating material, complete reassembling the motor, repair and overhauling of pumps, replacement of bearing, remetaling of gunmental impeller, grinding, polishing, greasing complete all as directed and testing complete to entire satisfaction of Engr-in-charge
Mohit Enterprises
Ambrish Builders
Avion Industries
P S TRADERS
MTR GROUP & COMPANY
TRINITY CONSTRUCTION
K R GUPTA AND SONS
Titco Electricals
Bidder Name
M/s RAM LAKHAN GUPTA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .