| 1 | L1₹36.6 LAccepted-AOC 0 BUDKIYA DEVATRA JODHPUR RAJASTHAN 342606 | JODHPUR | RAJASTHAN | 342606 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.2 L+₹2.3 L (5.97%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹40.8 L+₹2.9 L (7.60%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹41.2 L+₹3.3 L (8.72%)Rejected-Finance 6146 HIRA CHOWK SIRKI BAZAR BATHINDA PB 151005 | BATHINDA | PUNJAB | 151005 | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹89,300
Closing Date
16 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura Cantt
SPL REPAIR TO BLDG NO P-1449 (SINGLE JCOS ACCN) AT HISAR MIL STN UNDER GE HISAR
2020_MES_398771_2
CWE/MTR/HSR/62 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar
Class D cat a (i)
7 documents required · 7 mandatory
₹500
GE Hisar
₹89,300
Yes
26 Feb 2021
2 Jan 2021
18 Jan 2021
2 Jan 2021
16 Jan 2021
4 Jan 2021
60 days
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc. 1.50 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.50 sqm & n.exc 4.00 sqm each complete all as specified and directed.
Taking down shutters of any description area exc 1 Sqm but n.exc 2 Sqm each leaf complete all as specified and directed.
S&F Factory made solid PVC single door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with 19 mm x 19mm MS square tube having wall thickness 19 guage complete all as shown in sketch on SSR 2010 Part II complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with particle board core and 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F factory made steel windows, ISI Marked, (Box type) with side hung shutter including box type hinges with steel handle and tower bolt and steel peg stay with glazing bar, dovetailed or welded including making good disturbed surfaces of walls complete all as specified and directed. Note : HQ CEJZ Drawing No TD/2013/01 Sheet 1/3,2/3,3/3.
S&F factory made steel windows, ISI Marked, (Box type) with side hung shutter including box type hinges with steel handle and tower bolt and steel peg stay without glazing bar, dovetailed or welded including making good disturbed surfaces of walls complete all as specified and directed. Note : HQ CEJZ Drawing No TD/2013/01 Sheet 1/3,2/3,3/3.
S&F Pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, size of frame 125 x 60mm complete all as specified and directed.
S&F 35mm thick factory made glazed and skeleton shutters of 2nd class HW open rebated and prepared to receive glass/gauze etc edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc as specified in SSR Part - I section 8, clause 8.24 (a) complete all as specified and directed.
S&F 35mm thick factory made IInd class hard wood plain framed, panelled door shutters (any numbers of panel) with lock rail and panels of 12 mm thick BWR commercial plywood having seven ply with commercial veneers on both face of BWP grade and bonded with phenol formaldehyde synthetic resin adhesive ISI mark. The size of rail & stile as per IS :1003 (Part-I) kilnseasoned and chemically pressure treated complete all as specified and directed.
S&F Pressed steel frames for doors and cupboards with one or more rebates including necessary fixing lugs, hinges, lock strike plate, size of frame 75 x 60mm complete all as specified and directed.
S&F 25mm thick flush shutter, soild core construction with block board core and plywood face panels commercial type on both sides complete all as specified and directed.
M&L PCC 1:3:6 type C-0 (using 12.5mm graded stone aggregate), as in bed block or filling of chowkhats including necessary form work complete all as specified and directed.
S&F wire netting of stainless steel wire 1.23mm dia fixed with tinned tacks of stainless steel wire staple (size of mesh 12mm) to fixed with steel framed work and wooden framed work with & including necessary items complete all as specified and directed.
M&L 3mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all as specified and directed.
S&F 3mm thick figured glass pin head type and glazing with oil putty in squares n.exc 0.50 sqm each pane complate all as specified and directed.
S&F butt hinges 100mm stainless steel medium weight fixed with stainless steel screws complete all as specified and directed.
S&F 200mm long Aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F for 100mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 100mm aluminium anodised Hasp and staple, safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F 300mm, Mild Steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed.
M&L for preparation of old wooden surface of any description not otherwise described, exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over a coat of red oxide primer complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in Sub base of ground floors complete all as specified and directed.
M&L PCC 25mm thick 1:2:4 type B-0 using 12.5mm graded stone aggregate in sub flooring finished the rough surfaces complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 type C-1 (by using 20mm graded stone aggregate) for plinth protection finishing even and smooth without using extra cement complete all as specified and directed.
M&L for non-skid designer ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed CM (1:4) complete all as specified and directed.
S&F coloured Non Skid designer ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.18 Sqm but n.exc 0.38 Sqm in skirting / dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including 10mm thick rendering in CM (1:3) complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.16 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed CM (1:4) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removal of serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for coloured designer and pattern (dark and light shade combination) glazed ceramic tiles of size 300 x 450 x 7-8mm thick as in vertical surface like dado or skirting set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:3) complete all as specified and directed.
M&L 18-20mm thick machine cut Kota stone slabs of size 550 x 550mm (minimum) over and including 20mm thick screed layer in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of stone incl rubbing & polishing complete all as specified and directed. Note : Single piece stone slab will be used for the surface of staircase tread area.
M&L 15mm thick Kota stone slabs as in vertical surfaces like dado or skirting over 10mm thick rendering in CM (1:3) set & joined in neat cement slurry and pointed in coloured cement to match incl rubbing & polishing complete all as specified and directed. Note : Single piece stone slab will be used for the staircase riser area.
M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations etc complete all as specified and directed.
Dismantling roof tiles, single layer on roofs with and including demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
M&L for preparation of RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles. Filling the cracks by crack filler. Providing PCC 1:3:6 at the places where slope is not proper or roof surface is uneven to maintain the proper roof slope. Providing 25mm thick polymer modified plaster in ratio 1:10 (1 part of polymer and 10 parts of cement with solid contents not less than 30%) over slab and applying priming coat of epoxy primer with resin and hardner with water dilution as per manufacturer instructions, applying 1st coat of solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm and applying 2nd coat solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm over dried 1st coat complete all as specified and directed. Make : Pidilite / STP / Sika / Asian Paints
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and as directed.
S&F in repair Harrison rails, mild steel chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed.
Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work / concrete / stonewall and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work and mixing integral water proofing compound @ 3% by wt of cement or as per manufacturer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and directed. Note : Integral WPC shall be measured and paid separately under relevant items of BOQ (Schedule 'A')
M&L rendering 10mm thick on concrete surfaces on ceiling, sunshade and chajjas in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed.
M&L 15mm thick rendering with polymer modified cement plaster (ready mix plaster of approved make and only water is mixed at site) on concrete surface as in ceiling finished even and smooth complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar including all quoins, arches pillars etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius, built in CM (1:4) using old size bricks complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L two coats of Oil bound distemper on new plastered surfaces over and including not less than 1mm thick acrylic wall care putty and a coat of alkali resistant primer on walls including preparation of surfaces complete all as specified and directed.
M&L for complete removal of existing treatment of old surface of wall and applying two coats of oil bound distemper ove a coat of wall care putty (not less than 1mm thick) over a coat of alkali resistant primer on wall complete all as specified and directed. Note : The work under srl item No 53 & 54 shall be got carried out by contractor from authorised applicator of manufactrurer by using modern technique.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of cement base primer complete all as specified and directed.
M&L for complete removal of existing treatment on old surfaces of wall and applying two coats of cement based paint over a coat of cement base primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment on old surfaces of ceiling and applying two coats of white wash surfaces complete all as specified and directed.
Taking up or down steel water tubing and connection of 15mm bore complete all as specified and directed.
Taking up or down steel water tubing and connection of 20mm bore complete all as specified and directed.
S&F for GI tubing 15mm bore with all fittings and fixed to walls, ceilings or laid in floors medium grade complete all as specified and directed.
S&F for GI tubing 20mm bore with all fittings and fixed to walls, ceilings or laid in floors medium grade complete all as specified and directed.
Re-fixing old GI tubing 15mm dia medium grade with all fittings / connection in new or old position and fixed with concealed to walls, ceiling or laid in floors complete all as specified and directed.
Re-fixing old GI tubing 20mm dia medium grade with all fittings / connection in new or old position and fixed with concealed to walls, ceiling or laid in floors complete all as specified and directed.
S&F in repair vitreous china squatting pan (1st quality) ISI marked Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap including connection to trap and to flushing pipe, anti syphonage pipe and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick alround and finished just below level of rim of pan to receive the floor finishing and making good to floor complete all as specified and directed.
S&F in repair viterous China wash down water closet (pedestal pattern) white with 'P' trap complete connecting to flush pipe, including plastic seat cover white with flat bottom and mild steel chromium plated or aluminium hinging device (excluding flushing cistern and flushing pipe) and matching good to floor complete all as specified and directed.
S&F in repair PVC valveless, syphonic action type, flushing cistern, low level, 10 Ltr capacity white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F in repairs Vitreous China wash hand basin, white, flat back, size 550x400 mm including brackets 32mm bore PTMT waste coupling with long screwed shank and fly nuts and 32mm PVC waste pipe 90cm long etc complete all as specified & directed.
S&F in repair 15mm bore chromium plated cast copper alloy bib taps with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair chromium plated pillar taps cast copper alloy with capstan head screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints fitted to steel pipe or union complete all as specified and directed.
S&F in repair 15mm bore angle valve / stop valve (half turn type) chromium plated fancy type, cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe chromium plated with long shank and cup (concealed type) complete all as specified and directed.
S&F in repair 20mm bore stop valves (half turn type) fancy type chromium plated cast copper alloy with crutch or butterfly handles screwed down high pressure screwed both ends for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair PVC (SWR) multi floor trap with stainless steel grating with dia of outlet 75mm including jointing with solvent cement fixed in cement concrete (1:2:4) type B-1 complete all as specified and directed.
S&F PVC connection 15mm size, of length 450mm, with PTMT nuts at both ends complete all as specified and directed.
S&F in repair tubular towel rail of PTMT 20mm dia D type, 60cm long between flanges (minimum weight 190 grams) complete all as specified and directed.
Dismantling water tanks of any type & capacity complete all as specified & directed.
M&L PVC water tank triple layer white in colour rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 500 ltr complete all as specified and directed.
S&F Ball brass valves 20mm bore high pressure with polythene float and fly nut screwed for iron pipe of brass ferrule complete all as specified and directed.
S&F nipple suitable for HDPE water tank (min weight 15mm - 38gms / 20mm - 45gms / 25mm - 65gms) complete all as specified and directed.
Dismantling wrought iron or mild steel work (used in frame work for staging of water tank) of any description not other wise provided complete all as specified and directed.
S&F MS framed work such as grills, cooler stand, grating, etc., with ends of bars, shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work or water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S&F MS joist, channel, angle or tee sections, fixed independently without connecting plate etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed.
S&F 1.25mm thick plain, black mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board / slabs / blankets, any thickness, including framed work & cover fillets complete all as specified and directed.
M&L for providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 x 605mm in true horizontal level, hot dipped galvanised steel sections (galvanized @ 120 grams / sqm, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length and of size 24mm x 38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross 'T' of size 24mm x 28mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main 'T' at 600mm center to center to form a grid of 1200mm x 600mm and secondary cross 'T' of length 600mm and size 24mm x 28mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main 'T' runners to be suspended from ceiling using GI slotted cleats of size 27mm x 37mm x 25mm x 1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85mm x 30mm x0.8mm spaced at 1200mm center to center along main 'T' bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint complete all as specified and directed.
S&F gypsum board perforated 12mm thick for insulation and acoustic purpose 60 x 60 cm size, fixed to frame with screws as per manufacturer's instructions to GI snap grid complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for providing RCC M-25 (design mix) 20mm graded stone aggregate as in slab supported on walls, MS angle iron frame, beams and columns in floors, roofs, landingcomplete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landing etc not exc 200 mm thick (horizantal or slopping) for fair finished surfaces of concrete complete all as specified and directed.
M&L TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L precast cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in manholes and septic tank cover slab etc and set in cement mortar (1:4) complete all as specified and directed.
Treatment of sunken floor slab compraises of the following specifications and all as specified :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) GI pipe 50mm dia medium grade 50cm long laid on each sunken floor as spout complete all as specified and direced by EIC. (vii) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (viii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. Note :- (i) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. (ii) All debries obtained from site will be thrown away out side MD land by contractor at his own expense. (iii) Integral water proofing compound shall be measured and paid separately under relevent item of BOQ (Schedule 'A'). (iv) For payment purpose the plan area of sunken floor shall be taken into accounts. (v) The sunken floor shall be filled with lean concrete (1:7:12)
S&F in repair 110mm PVC (SWR) type 'A' pipes single socketed, including fittings in any length with rubber ring joints, fixed to walls or floors with necessary MS clamps of FI 25 x 3mm complete all as specified and directed.
S&F in repair 75mm PVC (SWR) type 'A' pipes single socketed, including fittings in any length with rubber ring joints, fixed to walls or floors with necessary MS clamps of FI 25 x 3mm complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) bends any radius with access door complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) bends any radius with access door complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for (sunken portion and floor) directed complete all as specified and directed.
S&F in repair 110mm bore SWR junction, single T equal or unequal with oval access door complete all as specified and directed.
S&F in repair 75mm bore SWR junction, single T equal or unequal with oval access door complete all as specified and directed.
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cable not exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Returning filling in, including spreading levelling and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Chipping of loose / damaged / cracked / previously repaired / delapidated or weak concrete to expose the sound core concrete whereever required to expose rusted reinforcement for all depth complete all as specified and directed.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg / ltr at 30°C and consumption : 0.2 kg / Sqm / coat complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg / Sqm for two coats and product requirements: carbonation resistance : 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N/Sqmm according to ASTM C 882-78 complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
Providing, cutting, bending and placing in position extra reinforcement bars of dia upto 16mm wherever required by means of welding with existing reinforcement (TMT bars) complete all as specified and directed.
M&L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer’s specification including prepartaion of surface by chipping and throughly cleaning for surface complete where ever required with using Product : Sikadur®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with consumption : 0.4 kg/Sqm and Product requirements : Complies with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed.
M&L for providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement and directions of Engineer-in-charge.
Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (>100 mm) using Product : SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx. 17 ltr/bag (30kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed.
Removing all disintegrated and loose concrete of any thickness including plaster if any in RCC Column, Chajja, slab, beams, lintels etc, removing all loose rust / scale from exposed reinforcement bars by using wire brushes and sand paper including cleaning of exposed surfaces of reinforcement with protective anti corrosive epoxy bonding chemical and tied reinforcement bars / IRC fabric 50mm x 50mm x 12gauge if reqd to reinforcement concrete bonding primer uniformly to exposed surfaces and applying cement mortar 1:3:1 with MPC (1 Part cement : 3 Part Sand :1 Part 6mm coarse aggregate) to an average thickness not less than 20mm and removing debris outside MD land complete all as specified and directed. Note : Reinforcement bars / IRC fabric shall be measured and paid as supply only.
Supply only IRC fabric 50mm x 50mm x 16 gauge / reinforcement bars to existing reinforcement by means of standard nut & bolts / clips complete all as specified and directed. Note for Srl item No 106 to 114 : (i) Necessary scaffolding / props (minimum one prop per sqm) required for repair works against aforesaid items is deemed to be included in contractor's quoted rate. (ii) Work has to be carried upto two storey buildings and nothing extra shall be paid to contractor on this ground. (iii) Digital photo / videography for all items of structural strengthening shall be done by the contractor in presence of JE (Civ) / Engineer-in-Charge. Copy of CD thereof shall be deposited to Engineer-in-Charge for record on completion of each stage as elaborated here-in-above. (iv) Cement used for the structural repair / rehabilitation work shall be of OPC grade.
Taking down carefully surface aluminium point wiring with wooden battens / PVC conduit (light, fan, socket, bell or power) including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc and making good disturbed surfaces complete all as specified and directed.
M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 1.5 sqmm (22/.3mm) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories including sunk type pressed steel terminal boxes with 3mm thick bakelite sheet top cover for mounting switches, sockets, fan regulators, including cutting, chasing on wall and other surfaces and making goood disturbed surface complete for the following :- Note : The cutting of chases will be done using wall chaser / wall groove cutting machine only.
One light / fan / bell / exhaus fan controlled by one switch.
One socket outlet 5 pin, 5 amp controlled by one switch on indepdendent board.
One socket outlet 5 pin, 5 amp controlled by one switch on the same board.
S&F lamp holder B-22 base insulated body with back plate and connecting up complete all as specified and directed
S&F LED bulb of capacity 15W complete all as specified & directed. Make : Havells Cat part No LHLDDEEEML8R015 or equivalent in make as specified in Appx 'B'.
M&L for point wiring with 1100 volts grade PVC insulated unsheated FRLS single core multistranded copper conductor cable 2.5 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories including sunk type pressed steel terminal boxes with 3mm thick bakelite sheet top cover with earth continuty conductor of FRLS PVC insulated unsheathed multistranded copper conductor cable 2.5 Sqmm complete for one switch socket combination 3 pin 15 Amp on independent board, including cutting, chasing on wall and other surfaces and making the good disturbed surface complete. Note : The cutting of chases will be done using wall chaser / wall groove cutting machine only.
S&F socket outlet 3/6 pin and 15 Amps flush type complete all as specified and directed.
S&F socket outlet 5 pin and 5/6 Amps flush type complete all as specified and directed.
S&F switch piano flush button single pole one way 5 Amp complete all as specified and directed.
S&F switch piano flush button single pole one way 15 Amp complete all as specified and directed.
S&F ceiling rose of 65 x 50mm PVC / polycarbonate three terminal surface bakelite complete all as specified and directed.
S&F LED base fixture including 18/20 retro LED tube rod energy saving surface mounted luminaire, high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack complete all as specified and directed. Make : Cat Part No SUB 118 T8 LED of Surya or equivalent and tube rod of 18/20W of Cat Part No SLE TL-DS 18P of Surya or equivalent make as specified in Appx 'B'.
S&F electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified and directed.
Disconnecting & taking down ceiling fan of any make & sweep carefully during re-wiring work & after complete re-wiring connecting, hanging ceiling fan with connecting wire including servicing (oil and greasing), including extension of down rod upto suitable length below ceiling complete all as specified and directed.
S&F sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified and directed.
S&F MCB TPN 63 Amp 4 Pole Breaking capacity 16 KA, (type 'C' curve) complete all as specified & directed.
S&F MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10 KA (type 'C') complete all as specified & directed.
S&F MCB SPN, 240 Volts, 40 Amps breaking capacity 10 KA (type 'C' curve) complete all as specified & directed.
S&F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified & directed. Note for item No 128 to 132 : (i) MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces. (ii) The cutting of chases will be done using wall chaser / wall groove cutting machine only.
S&F ceiling fans 1200mm sweep white in colour energy efficient 5 star rating of Aluminium blades (three numbers) and body, double ball bearing, down rod, fan motor, pair of canopy shackle, assembly kit, etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete all as specified and directed. Make : Havells Model ES-50 (enery saving fan) or equivalent make as specified in Appendix 'B'
S&F Building security light 20 watt LED, new generation, energy saving and environment friendly long life street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP-66 protection and impact resistance of IK-07 fixed with 40mm dia light grade, 1.5m long bracket and fixed with MS Clamps of size 40 x 5mm, 02 Nos, nut bolts and washers on wall complete all as specified and directed. Make : Cat Part No. ENDURAPEARLSL20WLED757SASYTOPC of Havells or equivalent make as specified in Appendix 'B'.
M&L for Sub main wiring with 2 single core PVC insulated unsheathed cable, 1100v grade with FRLS PVC 6 Sqmm copper cable multi stranded conductor drawn through in and including PVC rigid non metallic concealed conduit 25mm dia, medium duty, ISI Marked to be terminated in DB box as per IS including of 6 Sqmm dia FRLS PVC insulated unsheathed Copper cable as earth wire connected to earth including taking down old unserviceable sub main wiring complete all as specified & directed. Note : Two run of 6 Sqmm cable and one run of 6 Sqmm earth cable and one run of 25mm PVC conduit shall be considered as a unit for measurements purpose.
Supply, laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire, armoured electric power cable (heavy duty) with aluminium conductor, 1100 volt grade, cross sectional area of size 16 sqmm 4 core laid in trenches wall / floor etc complete all as specified and as directed. Note : Cable may be laid in trenches, under road, across the nallah, along poles/walls and ducts etc. Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection shall be measured and paid saprately.
M&L sand filling in trenches with clean dry fine sand unwashed including gently punning around cables 8cm thick before laying & 15cm after laying complete all as specified and directed. Note : Punned thickness of sand shall be measured and paid for.
M&L for brick covering to underground electric cable using sub class "B" old size brick laid dry flat perpendicular to the direction of cable complete all as specified and directed.
M&L for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall / pole for protection of cable / earthing strip etc complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15mm dia pipe and GI Pipe 20mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as specified & directed.
M/S KAVITA CONSTRUCTION
Deep Construction Company
B B BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .