Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹91.0 LAccepted-AOC NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹95.2 L+₹4.2 L (4.64%)Rejected-Finance WARD NO 9 HOUSE NO 41 ARYA SAMAJ GALI UDHAMPUR 182 101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-2 | Rejected-Finance Other than L-1 | |
| 3 | L-3₹98.7 L+₹7.7 L (8.45%)Rejected-Finance BIR SARDALIA RESIDENCY AIR FORCE ROAD BARYAL UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Rejected-Finance Other than L-1 | |
| 4 | L-4₹99.0 L+₹7.9 L (8.72%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-4 | Rejected-Finance Other than L-1 | |
| 5 | L-5₹1.0 Cr+₹13.9 L (15.3%)Rejected-Finance | L-5 | Rejected-Finance Other than L-1 |
Tender Value
₹91.3 L
EMD Value
₹1.6 L
Closing Date
10 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
IMPROVEMENT TO ALL STORE BLDG OF CSD DEPOT UNDER GE (NORTH) UDHAMPUR
2021_MES_489451_2
CWE/U(N)-69/2021-22
Open Tender
Civil Works
Item Rate
600 days
Udhampur
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE (North) Udhampur
₹1.6 L
Yes
17 Feb 2022
22 Nov 2021
12 Jan 2022
22 Nov 2021
10 Jan 2022
5 Jan 2022
60 days
Amount
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 02 above but except brick.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
M&L providing cement concrete type C1 1:3:6 (20 mm graded agg) 50mm thick in floors/levelling course/plinth protection incl making joints finished even & fair , complete all as specified and as directed by Engr-in-Charge.
M&L providing cement concrete type B-0 1:2:4 (12.5 mm graded agg) 40mm thick in floors incl laid in panels n.exc 1.2m x 1.2m each using glass strips 50mm wide and 4 mm thick incl making joints finished even & fair , complete all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick wear proof topping as specified (incorporating metallic floor hardener) laid on concrete floors and paving in panels and finished even & smooth (except metallic floor hardener) , complete all as specified and as directed by Engr-in-Charge. Note:- Metallic floor hardener shall be measured and paid separately as " Supply only".
Supply only metallic floor hardener of approved make , complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. , complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab of size 550x550 mm flooring 18-20 mm thick laid with marble border strip in approved pattern, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified. Note:- Marble border strip shall be measured and paid separately under respective item of BOQ.
Machine cut kota stone slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
80/100 mm wide x 550 mm long & 12 mm thick marble border of approved colour(white/green/yellow etc.), machine cut, bedded jointed and pointed with grey cement slurry, as in floors laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including avg 20 to 25 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
M&L for digital elevation tiles of size 300 x 600 mm of approved design and pattern laid over & including 10 mm thick CM 1:4 including jointing using spacers and joint & pointed with epoxy tile grout of same colour to match the shade of the tiles, complete all as specified and as directed by Engr-in-Charge.
M &L for 15 mm thick cement plaster in CM 1:4 on brick or concrete surfaces incl necessary dubbing out wherever required for making good of broken chajjas/columns/beams/slabs etc. finished even & fair surfaces complete all as specified and as directed by Engr-in-Charge.
M &L for 10 mm thick cement plaster in CM 1:4 on brick or concrete surfaces finished even and smooth surfaces complete all as specified and as directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed
Pre-painted coloured plain steel Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge/gutter for rain water pipes etc., colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed by Engr-in-Charge.
Taking down shutters of any descriptions area exceeding 1 square metre and not exceeding 2 square metre each and refixing in same opening complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , complete all as specified and directed by Engr-in-Charge.
Description all as per item No 22 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; hollow sections as in purlins, MS bolts etc., frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3 (ii) Glazing shall be measured and paid separately.
Factory made mild steel ventilators glazed or gauzed shutters with side hung including pintol hinges, steel peg stay , locking arrangement with glazing & gazing bars dovetailed or welded and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3. ii) Glazing, wire gauge shall be measured and paid for separately
Preparation of new or previously untreated steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame/wooden frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge.
110 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all specified and as Directed (ISI Marked)
Dismantling existing roof padding existing roof treatment, any thickness/type including removing demolished/ excavated material and depositing where directed or outside MOD land, complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick plastering in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm & including two coats of bituminous Aluminium paint, complete all as specified and as directed by Engr-in- Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
40 mm thick plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates in two layers (each 20mm) with chicken mesh provided between the layers and finished even smooth with false grooves @ 450x450 mm, complete all as specified and as directed by Engr-in-Charge. Note : chicken wire mesh shall be measured and paid for separately.
Wire netting of galvanised steel wire size of 20 mm but nominal dia 0.36mm and average width of aperture n exc 25 mm ,complete all as specified and as directed by Engr-in-Charge.
Supply only integral water proofing compound, complete all as specified & directed by Engr-in-Charge.
Factory Made, Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 Grade, with topping of cement with imported pigment including 30 mm thick sand cushioning bed including spreading levelling watering if required, Shape shall be approved by Engr-in-Charge.
Preparation of new plastered surfaces using 1mm thick external wall care putty & applying two coats of weather proof exterior emulsion paint (Apex Ultima or equivalent of makes mentioned in PS) over one coat of primer of any description/colour as approved, complete all as specified and as directed by Engr-in-Charge.
Preparation of old decorated plastered surfaces incl removal of existing treatment & applying two coats of weather proof exterior emulsion paint (Apex Ultima or equivalent of makes mentioned in PS) over one coat of primer of any description/colour as approved, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed by Engr-in-Charge.
Preparation of new plastered surfaces including applying 1mm thick wall care putty and applying two coats of oil bound distemper over and including a coat of primer complete all as specified & directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old wooden or wood based surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint , complete all as specified and as directed by Engr-in-Charge.
Preparation of old painted steel and iron surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint , complete all as specified and as directed by Engr-in-Charge.
160 mm bore PVC (SWR) pipes single/Double socketed of any length with rubber ring joints, pressure rating 4 kg/Sqcm (min), fixed to wall incl clamp etc , complete all as specified and as directed by Engr-in-Charge.
160 mm bore PVC SWR bends any radius with access door and fixed solvent etc, ISI marked, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
S&F Switch piano flush button single pole one way 5 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
S&F Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Environmental friendly, energy saving, surface mounted, decorative LED 10 Watt Bulk head luminire, with integral electronic LED driver with APFC and lower THD, Output complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following :- (a) Housing of Light fitting : Die Cast Aluminium (b) Diffuser : Polycarbonate UV protected diffuser (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 900 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4kV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, incl taking down old sheet metal encl DB 8 way including MCBs complete all as specified and as directed. (Note: MCBs will be measured separately).
MCB SPN, 40 to 63 Amps, 'C' series 10 KA , 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps, 'C' series 10 KA 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of outdoor type and floor mounted, LT control panel board made out of 2 mm thick MS/CRCA steel sheet mounted on 60cm long legs made out of 50 x 50 x 5 mm equal angle,provided with copper bus bars-04 Nos with color coated sleeves of capacity 1.5 times of in commer and internal wiring with PVC insulated copper conductor cable of adequate size for making connections to various equipments/accessories incl powder coated painting (internal & externally) complete over a coat of red oxide primer all as specified CPRI approved, embedded in PCC 1:24 type B-1 blocks of size 15x15x20 cm,front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable , factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice . The panel shall include & accomodate the following equiptments :- (a) Fixing only existing Energy metersingle phase digital type complete all properly isolated from panel body by means of providing bakellite sheet not less than 3 mm thick as base plate cable connections-08 Nos (b) MCCB 4 pole TPN , 63 amps 16 KA - 01 No (c) MCB SPN 40 to 63 Amp 230 V- 05 Nos (d) RYB indicators (set of three) - 01 set
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 16 sqmm 4 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 10 sqmm 2 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removal of excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point , complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable, complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Cutting of bituminous /PCC road including excavation to a standard depth and width as specified in SSR for laying GI pipe/XLPE cable, retruning filling including removal of surplus soil/debris to a distance not exceeding 50 metre and after returning filling, making good the distrubed ground by applying 100 mm thick stone soling, 75mm thick WBM and 30mm thick premix carpeting or applying 100mm thick PCC 1:1.5:3 type B-1 using 20 mm graded crushed stone aggregates over stone soling to match the exisitng surfaces of road complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 67 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
M/S Inderjit Sharma and Co.
SARDALIA CONST CO
SHIVAE CONSTRUCTION
paras ram pachiala
jyoti parkash sharma
KALSOTRA CONSTRUCTION CO
KAMLA CONSTRUCTION COMPANY
M/S KAPIL KUMAR KHATTAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .