| 1 | L1₹41.5 LAccepted-AOC PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹42.9 L+₹21,520 (0.50%)Rejected-Finance 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹44.3 L+₹1.6 L (3.87%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹45.0 L+₹2.3 L (5.48%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹45.7 L+₹3.0 L (7.06%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
4 Feb 2023, 6:00 pmClosed
Shri Prakash G Kalekar AE QS and C
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIR/REPLACEMENT OF LT UG CABLES, LT POLES, ACSR CONDUCTORS, STREET LIGHTS, SECURITY LIGHTS, FLOOD LIGHTS, PAINTING OF POLES, PANEL BOARDS AND ALLIED WORKS AT MIRC UNDER GE (S) AHMEDNAGAR
2023_MES_573480_1
8940/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AHMEDNAGAR
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
11 Feb 2023
6 Jan 2023
6 Feb 2023
6 Jan 2023
4 Feb 2023
20 Jan 2023
6 Jan 2023 - 13 Jan 2023
Amount
Excavation in trenches n exc 1.50 m wide and n exc 1.50 m deep for foundation, laying of cables, pipe or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
All as per serial item No 01 but depth exc. 1.5 m but n exc. 3 m.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and as directed.
Supply and lay HDPE pipe (PE 100, SDR-21, 6 Kgf/Sqcm), IS 4984-2016) 50mm dia for laying of LT cables etc complete with all accessories all as specified and as directed.
Supply and lay HDPE pipe (PE 100, SDR-21, 6 Kgf/Sqcm), IS 4984-2016) 63mm dia for laying of LT cables etc complete with all accessories all as specified and directed.
Supply and lay HDPE pipe (PE 100, SDR-21, 6 Kgf/Sqcm), IS 4984-2016) 110mm dia for laying of LT cables etc complete with all accessories all as specified and as directed.
Taking out existing 240 Sqmm, 3.5 core, underground LT XLPE armoured cable from trenches or pole or underground in pipe/duct carefully alongwith protection covers, cleaning of the same and relaying in trenches or pole or through pipe, jointing and testing complete all as specified and as directed. Note :- Excavation and earthwork shall be measured and paid separately.
All as per serial item No 8 but 185 Sqmm, 3.5 core
All as per serial item No 8 but 150 Sqmm, 3.5 core
All as per serial item No 8 but 120 Sqmm, 3.5 core
All as per serial item No 8 but 95 Sqmm, 3.5 core
All as per serial item No 8 but 70 Sqmm, 3.5 core
All as per serial item No 8 but 50 Sqmm, 3.5 core
All as per serial item No 8 but 35 Sqmm, 3.5 core / 4 core
All as per serial item No 8 but 25 Sqmm, 3.5 core / 4 core
All as per serial item No 8 but 16 Sqmm, 4 core
All as per serial item No 8 but 10 Sqmm 2 core
Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable of size 240 sqmm, 3.5 core with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall sheathed including cable gland, lugs, jointing material etc and jointing, connecting, testing and commissioning including taking out existing cable alongwith protection covers complete all as specified and as directed.
All as per serial item No 19 but 185 Sqmm 3.5 core
All as per serial item No 19 but 120 Sqmm 3.5 core
All as per serial item No 19 but 95 Sqmm 3.50 core
All as per serial item No 19 but 70 Sqmm 3.5 core
All as per serial item No 19 but 50 Sqmm 3.5 core
All as per serial item No 19 but 35 Sqmm 3.5 core
All as per serial item No 19 but 25 Sqmm 3.5 core
All as per serial item No 19 but 16 Sqmm 4 core
All as per serial item No 19 but 10 Sqmm 2 core
All as per serial item No 19 but 10 Sqmm 4 core
S&F in repairs, 80mm bore dia galvanised steel tube light grade for protection of cable complete all as directed
All as per serial item No 30 but 50 mm bore dia
All as per serial item No 30 but 40 mm bore dia
S&F in repairs/replacement, straight through cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing for 10 to 16 Sqmm 4 core cable all as specified and as directed.
All as per serial item No 33 but 25 to 50 sqmm 3.5 core cable
All as per serial item No 33 but 70 to 120 sqmm 3.5 core cable
All as per serial item No 33 but 150 to 185 sqmm 3.5 core cable
All as per serial item No 33 but 240 sqmm 3.5 core cable
S&F in repairs/replacement, end termination cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing for 10 to 16 Sqmm 4 core cable all as specified and as directed.
All as per serial item No 38 but 25 to 50 sqmm 3.5 core
All as per serial item No 38 but 70 to 120 sqmm 3.5 core
All as per serial item No 38 but 150 to 185 sqmm 3.5 core
All as per serial item No 38 but 240 to 300 sqmm 3.5 core
Drilling hole under road for laying of underground cable through pipe of suitable size complete all as specified and as directed. Note : Cost of T&P required shall deemed to be included in the unit rate quoted.
Supply install and testing in replacement out door wheather proof bus bar chamber of size 80 cm x 30cm x 25cm made out of 18 SWG MS sheet having one side openable hinged door shuter with looking arangement/provision of two nos 80cm long 40x40x6mm anlge iron legs welded and 04 nos copper bus bar of 400Amp rating, one MCCB TPN 125 Amp 16 KA for controlling electric supply complete erected on ground with & including necessary PCC 1:3:6 type C2 foundation complete, bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles all as specified and as directed. NOTE: Cost of dismantling/ taking down old unserviceable bus bar chamber shall deemed to be included in the unit rate quoted
Supply and erection in replacement, steel tubular swaged pole complete with mild steel box plate 6 mm thick of size 300 x 300 mm, finial taper plug, pole cap, bolts, nuts, washers & screws as specified type 410- SP-31 (9 m long) made out of ERW mild steel tubing confirming to IS-2713 Part II including drilling holes of required size for fixing cross arms etc erected in true vertical position including painting the pole with two coats of aluminium paint over a coat of red oxide primer on exposed pole surfaces and two coats of black bituminoius paint for portion embedded in concrete including painting three black/red/ bands at lower portion of pole of 1.5m height at 300 mm spacing, painting pole number with black paint at suitable height complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation of pole/stays etc complete all specified and as directed
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping of pole and similar work including finishing the surfaces even and smooth without using extra cement and necessary formwork complete all as specified and as directed.
M&L for stay assembly comprising of 16 mm dia stay rod, 1800 mm long, loop type insulator of size 65 mm x 90 mm, galvanised stay plate 6mm thick of size 250mm x 250mm and stay bow including dismantling of old Stay assembly complete as shown in Electrical Plate No. 1 of SSR Part-I all as specified and as directed. (Note : Excavation/earth work and PCC shall be measured and paid seperately under respective items).
M&L for galvanised stay strand 7/3.15 mm complete all as specified and as directed
Dismantling GI cradle/earthwire/stay strand complete all as specified and as directed.
S&F 4mm dia continuous galvanised earth wire for cradle/guarding connecting properly to cross arms, hook etc with and including 22 SWG binding wire all as specified and as directed.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI or steel earth strip 25 mm x 4 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 32mm dia GI pipe, light grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
Disconnecting electric supply from over head line and removing existing binding wire and ACSR conductor and restringing of ACSR conductor including binding of conductor on insulator with new binding wire and reconnecting the electric supply complete all as specified and as directed.
S&F line separators for two conductors complete all as specified and as directed.
All as per serial item No 54 but for three conductor
All as per serial item No 54 but for four conductor
Dismantling cross arms, bracings, support channel, back plate, hooks etc of mild steel channel or angle section etc complete all as specified and as directed.
S&F cross arms, bracings, support channel, back plate, hooks etc fabricated from structural steel sections (Mild steel Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed.
Dismantling LT insulator any type any size complete all as specified and directed.
S&F pin type porcelain vitreous brown/white insulator of size 100 mm height and 65 mm dia for 1100 Volt grade with approved make including one galvanised mild steel spindle two GI washers and GI nut including taking out old unserviceable insulator complete all as directed
S&F shackle type porcelain vitreous brown/white insulator of size 75 mm height 90 mm dia for 1100 volt grade with approved make including galvanised mild steel strip washers, insulated bolts, washers nut including taking out of old unserviceable insulator complete all as directed.
Dismantling ACSR conductor from LT/HT pole complete all as specified and as directed.
M&L for aluminium conductor steel reinforced, any size, (Weasel/ Ferret/ Squirrel as required) including stringing, binding, jointing, jumpering etc on insulators or on poles with minimum sag complete all as specified and as diercted.
M&L for preparation of old painted surfaces of LT poles by scrapping etc and painting with two coats of silver aluminium paint and alternate painted strip of 30cm width of colour as approved by accepting officer upto 1.5 meter height from bottom of the pole and writing pole number with black paint on yellow circle all as spcified and as directed
Trimming of tree branches touching to the LT/HT over head line or near to the LT/HT over head line as per the direction of AGE E/M/JE incharge complete including removing the tree branches from site complete all as specified and directed. Note : (i) Written shut down shall be obtained from concerned JE/AGE (E/M) before taking the trimming work in hand by contractor. (ii) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job. (iii) Any damage caused due to negligence of workmen will be rectified without any extra cost to the department. (iv) T&P such as ladder, rope, cutter, Axes and other related material shall be arranged by the contractor and the cost shall be deemed to be included in the rate quoted.
Clearing of bushes /small plants up to root level around and surrounding area of E/M installations (i.e two pole / four pole structures, out door substation yards & misc E/M installations etc) including surface dressing n.exc 15cm deep and removing debris to distance n.exc 50m complete all as specified and as directed.
M&L for disconnecting burnt LT under ground cables of 16 sqmm 3.5 core size from MCCB/Main switch/OH Line etc and cleaning the bus bar and removing carbon and rusted nut bolts etc complete and reconnecting the LT cable after replacement of aluminium lugs, glands etc all as specified and as directed.
All as per serial item No 67 but LT under ground cables of 25 sqmm 3.5 core size
All as per serial item No 67 but LT under ground cables of 35 sqmm 3.5 core size
All as per serial item No 67 but LT under ground cables of 50 sqmm 3.5 core size
All as per serial item No 67 but LT under ground cables of 70 sqmm 3.5 core size
All as per serial item No 67 but LT under ground cables of 95 sqmm 3.5 core size
All as per serial item No 67 but LT under ground cable of 120 sqmm 3.5 core size
All as per serial item No 67 but LT under ground cable of 150 sqmm 3.5 core size
Repairs to LT panel boards of any size complete with necessary welding works to doors, replacement of unserviceable hinges and aldrop bolt complete with and including painting with one coat of synthetic enamel paint of approved colour internally and externally all as specified and as directed.
Replacement of damaged sheet of panel board of any size with and including 14 SWG mild steel sheet to match to existing other sheet including bending, cutting, pressing to required size and shape all as directed
S&F in repairs, MCCB TP 63 amps capacity, 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB with and including replacement of lugs, nuts bolts etc and connection to incoming and outgoing cables all as specified and as directed.
All as per serial Item No 77 above but 100 Amps capacity, 25 KA
All as per serial Item No 77 above but 160 Amps capacity, 36 KA
All as per serial Item No 77 above but 200 amps capacity, 36 KA
All as per serial Item No 77 above but 400 amps capacity, 36 KA
S&F in repairs, 415V 10KA 'C' curve MCB TPN 100 Amps 10 KA poles and current carrying capacity fixed in the DB complete with connection, testing and commissioning all as specified and as directed.
All as per serial item No 82 but MCB TPN 63 Amps 10 KA
All as per serial item No 82 but MCB TPN 40 Amps 10 KA
Supply, install, testing and commissioning in replacement, factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 400 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA, MS sheet and with base frame of 50x50x6mm angle iron , powder coated, front and rear opening type with aprons for cable entry with double door shutter and locking arrangement with and including following items:- NOTE: Cost of dismantling/ taking down old unserviceable LT feeder piller box shall be included in the quotedd rate of this item. Incoming (a) MCCB 250 amps, 4 pole, 36 KA, 415 volts - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 400 Amp, 4 pole, not less than 45 cm long mounted on insulators for incomming supply 01 No. (c) Digital Ammeter & Voltmeters-01 set (d) Neon indicating lamps (R, Y & B) -01` Set. Outgoing (a) MCCB 160 amps, 4 pole, 36 KA, 415 volts grade - 02 No (b) MCCB 100 amps, 4 pole, 25 KA , 415 volts, 50 Hz - 03 No.
Supply, install, testing and commissioning in replacement of factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted, compartmentalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA, MS sheet and with base frame of 40x40x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement with and including following items. (Location- MAP PH I) NOTE: Cost of dismantling/ taking down old unserviceable LT feeder piller box shall be included in the quotedd rate of this item. Incoming (a) MCCB 200 amps, 4 pole, 25 KA, 415 volts grade, with thermal magnetic - 01 No (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp, 4 pole, mounted on insulators for incomming supply - 01 Set. (c) Volt meter and Amp meter 415 volts, 50 Hz AC supply -01 set. (d) Neon indicating lamps (R, Y & B) -01` Set. Outgoing (a) MCB TPN 63 amps, 4 pole, 10 KA , 415 volts, 50 Hz - 05 No. (b) MCB SPN 40 amps, 10 KA , 230 volts- 01 No.
S&F in repairs, LT cable route indicator, cast iron of suitable size with height of 1.5 metre along with LT cable trench including planting in ground with PCC 1:2:4 type B1 using 20mm graded stone aggregates complete all as specified and as directed.
S&F in repairs, panel/meter box of size 80cm x 60cm x 30cm made out of 18 SWG mild steel sheet having one side openable hinged door shutter with transperent glass for meter reading with locking arrangement, mounted on wall complete with two coats of approved enamel paints over one coat of primer including making of cable connection with necessary glands,lugs/thumbles all as specified and as directed.
M&L for disconnecting and taking down old unserviceable street light fittings/gate lights & garden lights of any type/rating from pole or wall dismantling the same for necessary repair or replacment of unserviceable spares complete and refixing, connecting and testing the same all as specified and directed by Engineer-in-Charge. Notes:- (a) Spares/accessories required for replacement shall be measured and paid sepratley as supply only under respective items of BOQ. (b) T&P required for repair/ mantenance such as ladder, vehicle like crane, manpower etc, shall be included in the quoted rate of this item.
Supply only surge protection devices compatible with industrial & outdoor LED fixtures as per existing make and model suitable for 30 Watt LED fitting all as specified and as directed.
All as per serial item No 90 but suitable for 50 Watt LED fitting
All as per serial item No 90 but suitable for 60 Watt LED fitting
All as per serial item No 90 but suitable for 90 Watt LED fitting
All as per serial item No 90 but suitable for 120 Watt LED fitting
Supply only LED drivers compatible with industrial & outdoor LED fixtures/Sign boards as per existing make and model suitable for 30 Watt LED fitting all as specified and as directed.
All as per serial item No 95 but suitable for 50 Watt LED fitting
All as per serial item No 95 but suitable for 60 Watt LED fitting
All as per serial item No 95 but suitable for 90 Watt LED fitting
All as per serial item No 95 but suitable for 120 Watt LED fitting
All as per serial item No 95 but suitable for 150 Watt LED fitting
S&F GI pipe bracket made out from 40mm bore light grade GI pipe, ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc and fixed on pole complete including dismantling existing bracket all as specified and as directed. (Note: - The total length of the bracket shall be 1.5m)
S&F GI pipe bracket made out from 50mm bore light grade GI pipe, ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc and fixed on pole complete including dismantling existing bracket all as specified and as directed. (Note: - The total length of the bracket shall be 1.5m)
S&F in replacement, PVC insulated and over all PVC sheathed, stranded copper conductor wire 1.5sqmm x 3 core ISI marked complete from fitting to pole junction box complete all as specified and as directed.
S&F in replacement, 2.5sqmm 2 core, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor all as specified and as directed.
All as per serial item No 104 but 4 sq. mm 2 core
All as per serial item No 104 but 10 sq. mm, 2 core
S&F junction box of size 255 mm x 205 mm x 112 mm with bus bar and MCB 6 Amp, SP fixed on pole with mild steel clamps and connecting with existing cable. Junction box shall be insulated and made out of Polycarbonate, environment friendly, recyclable, UV resistant, halogen & silicon free, antiacid & anti corrosive. The junction box shall be rated for degree of ingress protection IP 66 in accordance with IEC 60529. For better safety the Polycarbonate encluding shall be fire retardant & self-extinguishing complete including taking out old unserviceable box all as specified and as directed.
Repair of unserviceable time switch with replacement of accessories/ spares including reconnecting and testing complete all as specified and as directed. Note - Spares/accessories required for replacement shall be measured and paid seprately under respective item of BOQ.
Supply only time switch digital type, single phase, 230 Volts, 50 Hz of rating 20 Amps all as specified and as directed.
Supply only contactor 2 pole 40 Amps main pole confugration 230 volts fixing with existing box by suitable size of copper cable with suitable size of lugs complete all as required at site all as specified and as directed.
Supply only contactor 3 pole 40 Amps main pole confugration 415 volts fixing with existing box by suitable size of copper cable with suitable size of lugs complete all as required at site all as specified and as directed.
Lowering of high mast lantern carriage for repair including disconnecting and taking down unseviceable high mast light fittings of any type/rating dismantling the same for necessary repair / replacment of unserviceable spares and refixing, connecting, testing including raising high mast lantern carriage to its original position complete all as specified and directed. Notes:- (a) Spares/accessories required for replacement shall be measured and paid seprately under respective item. (b) The cost of T&P required for repair/ mantenance such as ladder, vehicle, menpower etc, shall deemed to be included in the quoted rate.
Repairing of highmast for electrical operation of raising and lowering of lantern carriage with its supporting stand complete as required at site and as directed including following:- (a) Fixing, connecting and testing of existing stainless steel wire rope of 6mm dia (7/19 construction) with double drum winch. (b) Repair / servicing of integral power tool, three phase, high powered, reversible with mechanical tripping facility. (c) Renewal of trailing cable, flexible copper 5 core 2.5 Sqmm through shaft. (d) Repair of manual lowering hoisting chain link mechanism. Notes:- (a) Spares/accessories required for replacement shall be measured and paid seprately under respective item. (b) Cost of T&P required for repair/ mantenance such as ladder, vehicle, manpower, welding cutting arrangement etc, shall deemed to be included in the unit quoted rate.
Dismantling, opening, rewinding and refixing 3.0 HP motor, three phase, 415 V, 50 Hz motors with super enamelled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechinical works for shaft / bearing housing, renewal of DE and NDE bearings, transportation from installation to workshop & back, connecting, testing and commissioning all as specified and as directed.
Supply only in replacement, starter suitable for 3.0 HP motor, three phase, 415 V , AC supply with forward/ reverse switch for high mast raising and lowering of lantern carriage with its supporting stand all as specified and as directed.
Supply only in replacement, PVC insulated and over all PVC sheathed, stranded copper conductor wire 4.0 sqmm x 5 core ISI marked all as specified and as directed.
Repairing of highmast light panels complete with necessary welding works to doors, replacement of unserviceable wiring, fixing of time Switch, contactor & MCB etc all as specified and as directed Notes:- (a) Spares/accessories required for replacement shall be measured and paid sepratley under respective item. (b) Cost of T&P required for repair/ mantenance such as ladder, vehicl, manpower, welding cutting arrangement etc, shall deemed to be included in the quoted rate.
S&F in replacement 150 watt LED flood light, energy saving, environmental friendly, long life, exclusive innovative diecast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting. Make: LUKER, Cat No. LFLSL150 or equivalent in Philips/Wipro/ Crompton/Havells/Halonix/Century LED
S&F in replacement 50 watt LED flood light, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting all as specified and as directed. Make: LUKER, Cat No. LFL50 or equivalent in Philips/Wipro/ Crompton/Havells/Halonix/Century LED
S&F in replacement 30 watt LED street light of new generation energy saving and environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07, suitable upto 40 mm mounting pipe all as specified and as directed Make: LUKER, Cat No. LSTE-30 or equivalent in Philips/Wipro/ Crompton/Havells/Halonix/Century LED
S&F in replacement 60 watt LED street light of new generation energy saving and environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07, suitable upto 40 mm mounting pipe all as specified and as directed Make: LUKER, Cat No. LST-60 or equivalent in Philips/Wipro/ Crompton/Havells/Halonix/Century LED
S&F in replacement 90 watt LED street light of new generation energy saving and environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07, suitable upto 40 mm mounting pipe all as specified and as directed Make: LUKER, Cat No. LST-90 or equivalent in Philips/Wipro/ Crompton/Havells/Halonix/Century LED
S&F in replacement of post top lantern light decorative type post top for 360 degree indirect light IP 65 protection resistant to impact and corrosion . Glare-free and better uniformity 15 watt LED 230 V 50 Hz including necessry fitting accessories complete all as specified and as directed as per Havells cat No. CORALMINIPT15WLED757PSYMTOPC or equivalent in Philips/Wipro/ Crompton/LUKER/Halonix/Century LED
RELIABLE ENTERPRISES
metro electrical services
M/s. N D Karande
Ms. S.K. ASSOCIATES
KESARI AND SONS
BHAVIN INFRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .