Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹13.3 L
EMD Value
₹26,617
Closing Date
21 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer ( Electrical ) BSNL ED Shimla
TOP FLOOR BLOCK NO. 35 KASUMPATI SHIMLA 171009
Construction of Eklavya Model residential school Pangi at Kilar Dharwas Tehsil Pangi District Chamba HP SH- Provision of Fan Fitting, Power distribution and Lightening arrestor in Studio ApartmentsTransit Accommodation Blocks
2026_BSNL_293818_1
42/EE/E/BSNL/ED/ETEN/SML/26-27
Open Tender
Electrical Works
Item Rate
30 days
Pangi at Kilar Dharwas
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Account Officer (EF) BSNL, O/o CGMT, HP Circle Shi
₹26,617
8 Oct 2026
8 Oct 2026
22 Oct 2026
8 Oct 2026
21 Oct 2026
8 Oct 2026
8 Oct 2026 - 17 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.1 | SUB HEAD-I (Fan & Fittings & Misc.) | - | - | - | - |
| 1.11 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50Hz, Operating temp range -5°C to 40°C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 4000°K/5700°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior Make) | - | - | - | - |
| 1.12 | Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 40 Watt | 196 | Nos. | 100 | ₹19,600 |
| 1.13 | Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22 Watt | 32 | Nos. | 100 | ₹3,200 |
| 2Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /Square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 4000°K /5700°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . | |||||
| 2.1 | Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 12-15Watt | 88 | Each | 10 | ₹880 |
| 3SITC of following type prewired surface / recess mounted (minimum colour code 840) LED light fixture & integrated electronic driver (wherever required) suitable to operate on 240 volts 50 HZ AC supply including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. (Preferred make Philips/ Wipro/ Havells/ Crompton/ Bajaj/ Osram/ Surya or Similar Superior Make) | |||||
| 3.1 | LED retrofit type T Lamp/ Round Lamp /Radial lamp minimum 15Watt with accessories etc as required | 4 | Nos | 10 | ₹40 |
| 3.2 | 10 watt LED Bulkhead Luminaire with Opal diffuser, PDC Housing 2 KV inbuilt surge protection with IP 65 protection rating with accessories etc as required | 8 | Nos | 100 | ₹800 |
| 3.3 | 4 module polycarbonated UV stabilized LED Foot light 2.5/3 Watts with accessories etc as required | 12 | Nos | 100 | ₹1,200 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
TENDEREIFANDHARWAS08102026.pdf
Tender Documents • 0.80 MB
BOQ_342570.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .