Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-Finance CSC 10 SHOP NO 3 4 POKET F 24 DDA MARKET SECTOR 3 ROHINI DELHI 110085 | NORTH WEST | DELHI | 110085 | ₹3.8 L | L1 | Accepted-Finance OK |
| 2 | L2₹5.0 LAccepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | ₹5.0 L | L2 | Accepted-Finance OK |
| 3 | L3₹5.1 LAccepted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹5.1 L | L3 | Accepted-Finance OK |
| 4 | L4₹6.4 LAccepted-Finance | ₹6.4 L | L4 | Accepted-Finance OK |
Tender Value
₹7.5 L
EMD Value
₹14,986
Closing Date
26 Feb 2026, 3:00 pmClosed
Executive Engineer (E)
Executive Engineer (E) North West, Elect. Divn., PWD ISBT, Kashmere Gate, Delhi-110006
ARMO Various Electrical Installation and Mechanical Equipments of 119 type-III, Residential Quarters for the staff of GNCTD of Delhi at Sector- 11, Rohini, Delhi. (SH Upgradation of Electrical Installation of 07 Nos. Type - III Quarters)
2026_PWD_287307_1
192/EE(E)/NWED/PWD/2025-26
Open Tender
Electrical Works
30 days
Rohini
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹14,986
Yes
28 Feb 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group A
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm
b) 3 x 4 sq. mm
c) 3 x 6 sq. mm
d) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. a) 1 or 2 Module (75mmX75mm)
b) 3 Module (100mmX75mm)
c) 6 Module (200mmX75mm)
d) 8 Module (125mmX125mm)
e) 12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch
b) 15/16 A switch
c) 6 pin 15/16 A socket outlet
b) Bell push
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing of Fancy wall bracket in stainless steel base duly wired with B-22 lamp holder suitable for CFL lamp/LED Retrofit lamp complete with all accessories i/c connection etc as required but without lamp.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 16 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
b) Double pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A
SITC of surface mounted IP65 rated LED bulkhead luminaire of nominal lumen output of 700 lumens with minimum efficacy of 100 lms/watt with glare free polycarbonate diffuser having colour temperature of 6500k, CRI>80 in aluminium housing body complete with all accessories with suitable LED driver etc. including PVC connector & PVC flexible conduit from light point to fitting and connection with 3 x 1.5 sq. mm copper wiring etc. complete as reqd.
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18- 22 Watt
S/I/T/C of 1200 mm sweep BEE star rating energy efficient ISI marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with power Consumption of Max. 50W capable to deliver 220 CFM (min.), speed of 350 rpm (min.) i/c wiring the down rod of standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc and help of steel chain approx 1 mtr x 2 nos. as reqd. (including dismantling the old fitting if any)
Supplying & fixing of 300 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.80 MB
BOQ_380658.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid