Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹8.3 L+₹74,840 (9.97%)Rejected-Finance 20 JAIN BAZAR JAMMU 180003 J K | JAMMU | JAMMU | J K | 180003 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹9.2 L+₹1.7 L (22.2%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹10.1 L+₹2.6 L (34.8%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
10 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / REPLACEMENT OF DG SETS, BATTERY CHARGER, CONTROL PANEL AND OTHER CONNECTED WORKS AT BHALRA MIL STN UNDER GE (I) 873 EWS
2023_MES_580232_1
NIT-80 of 2022-23
Open Tender
Civil Works
Item Rate
270 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹20,000
Yes
29 Mar 2023
10 Feb 2023
13 Mar 2023
10 Feb 2023
10 Mar 2023
24 Feb 2023
Amount
Draining out the old engine oil from DG set, cleaning of deposits and rectifing leakages, if any, by means of welding, brazing and cleaning of oil tank and Supply and filling of new Engine oil complete all as specified and directed.
M&L for taking down radiator from DG Set of any type /make of capcity 20 to 50KVA from base mounting , cleaning /descaling by using of air compressor and cleaning with suitable stain removal detergent along with chemical etc and rectifing water leakage by means of welding / brazing, after cleaning , descaling and rectifing of leakage etc. including renewal of all connecting parts i.e radiator hose pipe with clamps , bolts, nuts washers , rubber bush packing materal etc and re-assembling the radiatorand fixing with DG set properly in original position, checking the alignment, making proper hose connecting, testing for smooth operation complete all as directed. Note :- The cost of renewed parts is deemed to be included in unit rate quoted by contractor. No extra cost shall be paid to the contractor for the same.
Ditto all as per item No 2 here in before but 100 KVA 320 KVA
M&L for taking out of injector of DG Set of any type/make of capacity 20 KVA to 45 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling / servicing fuel injector system, including renewal of injector kit, calibration of injector, checking of pressure complete for each injector and re-assembling the same in original positon by making proper fuel connnection and testing for smooth operation complete all as directed. (Note: Renewal of parts to be measured & paid separately)
Supply only Needle valve
Supply only Nozzle holder
M&L for taking out of injector of DG Set of any type/make of capacity 100 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling / servicing fuel injector system, including renewal of injector kit, calibration of injector, checking of pressure complete for each injector and re-assembling the same in original positon by making proper fuel connnection and testing for smooth operation complete all as directed. (Note: Renewal of parts to be measured & paid separately)
Supply only Needle valve
Supply only Nozzle holder
M&L for taking out of injector of DG Set of any type/make of capacity 320 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling / servicing fuel injector system, including renewal of injector kit, calibration of injector, checking of pressure complete for each injector and re-assembling the same in original positon by making proper fuel connnection and testing for smooth operation complete all as directed. (Note: Renewal of parts to be measured & paid separately)
Supply only Needle valve
Supply only Nozzle holder
Supply and fixing high pressure fuelline sutable for Dgset of capacity 20KVA to 50 KVA complete all as directed.
Supply and fixing high pressure fuelline sutable for Dgset of capacity 100 KVA complete all as directed.
Supply and fixing high pressure fuelline sutable for Dgset of capacity 320 KVA complete all as directed.
Opening /taking out of fuel injection pump (FIP) of DG Set of any type/make of capacity 20 KVA to 45 KVA, disconnecting of fuel injector line, carrying complete overhauling /servicing of injecor pump, calibration of fuel pump as per manufacturer instruction, assembling of the same with DG Set properly in original position, checking the allignment, making proper fuel connection including renewal of unserviceable/defective minor parts like seal, 'O' ring, gaskit fuel pump, gear, technometer, bushing, technometer cover, fuel pump, gear housing, fuel pump gear etc and testing for smooth operation complete all as directed. Note: After renewal major parts if found defected shall be measured & Paid seperately.
Supply only Plunger
Supply only Control rack
Opening /taking out of fuel injection pump (FIP) of DG Set of any type/make of capacity 100 KVA, disconnecting of fuel injector line, carrying complete overhauling /servicing of injecor pump, calibration of fuel pump as per manufacturer instruction, assembling of the same with DG Set properly in original position, checking the allignment, making proper fuel connection including renewal of unserviceable/defective minor parts like seal, 'O' ring, gaskit fuel pump, gear, technometer, bushing, technometer cover, fuel pump, gear housing, fuel pump gear etc and testing for smooth operation complete all as directed. Note: After renewal major parts if found defected shall be measured & Paid seperately.
Supply only Plunger
Supply only Plunger Barel sleeve
Opening /taking out of fuel injection pump (FIP) of DG Set of any type/make of capacity 320 KVA, disconnecting of fuel injector line, carrying complete overhauling /servicing of injecor pump, calibration of fuel pump as per manufacturer instruction, assembling of the same with DG Set properly in original position, checking the allignment, making proper fuel connection including renewal of unserviceable/defective minor parts like seal, 'O' ring, gaskit fuel pump, gear, technometer, bushing, technometer cover, fuel pump, gear housing, fuel pump gear etc and testing for smooth operation complete all as directed. Note: After renewal major parts if found defected shall be measured & Paid seperately.
Supply only Plunger
Supply only Control rack
S&F, testing and commissioning in replacement of self starter 12 V DC suitable for 30 to 100 KVA DG set complete all as specified and directed.
S&F, testing and commissioning in replacement of self starter 24 V DC suitable for 320 KVA DG set complete all as specified and directed.
Supply & laying of Synthetic rubber insulated mats 2.5mm thick for voltage upto1100 V for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2m x 1m, complete all as directed. (Make: Jyoti/Jaipuria)
Taking down old unserviceable fuel feed pump and S&F feed pump for fuel injection pump complete assy for various capacity of DG Sets.
S&F (in repairs) of fuel shut down solenoied valve kit including taking out old valve assy and making all connection testing for smooth operation in any type DG Set complete all as specified and directed.
M&L for 'B' check kit of DG set 20 KVA to 45 KVA complete all as directed.
M&L for 'B' check kit of DG set 100 KVA complete all as directed.
M&L for 'B' check kit of DG set 320 KVA complete all as directed.
S&F (in repairs) element Air cleaner for DG set cap 20 KVA to 50 KVA complete all as directed.
S&F (in repaitrs) element Air cleaner for DG Set 100 KVA complete all as directed.
S&F (in repairs) element Air cleaner inner and outer for DG Set 320 KVA complete all as directed.
S&F (in repairs) Radiator cap suitable for DG set of any type /make and capacity complete all as directed.
S&F (in repairs), V- belt of size A-48 suitable for DG Set 20 KVA to 50 complete all as directed.
S&F (in repairs), V-belt of size AX60/A49 suitable for 100 KVA complete all as specified.
S&F ( in repairs) , V-belt of size AX39 suitable for DG Set 320 KVA complete all as directed.
M&L for top up of concentrated form coolent in radiator of DG Set of any type/Make and capacity complete all as directed. Make :-Bosch, feelit guard & equalient Note: Measurement shall be done only in concentrate form of coolant.
S&F (in repairs) Fuel hose flexible with matalic tape from fuel tank to filter, filter to FIP including allied nut bolt washer and coupling for DG set 20 KVA to 50 KVA with and including taking out old hose and making all connection testing for smooth operation all as directd.
Ditto all as per item No 29 here in before but 100 KVA
Ditto all as per item No 29 here in before but 320 KVA
S&F (in repairs ) of radiator hose pipe suitable both inlet and outlet of 20 KVA to 50 KVA DG Set with including taking out old hose and making all connection, testing for smooth operation complete all as directed.
S&F (in repairs) of radiator hose pipe of 100 KVA DG Set with including taking out old hose and making all connection, testing for smooth operation complete all as directed.
S&F (in repairs) of radiator hose pipe of 320 KVA DG Set with including taking out old hose and making all connection, testing for smooth operation complete all as directed.
S&F in replacement of 12 V 180 AH Battery tubular all as specified and directed. Make: Exide/Amron/Tata or equalent make
S&F (in repair) of 12 V 150 AH Battery tubular all as specified and directed. Make: Exide/Amron/Tata or equalent make
S&F in repair of battery terminals made of brass , suitable for battery of any type /make and capacity complete all as directd.
S&F in repairs of PVC insulated multi stranded copper conductor single core unsheathed cable of size 70 sqmm , 1100 volts grade for battery lead Red and Black colour all as directed.
S&F (in repairs) thermostat with new thermostat alongwith complete assy for DG set connection complete all as specified and directed.
S&F (in repairs) RPM CABLE of any type/make of DG set complete all as specified and directed.
S&F (in repairs) Water Temp Meter of any type and all as specified and directed.
S&F (in repairs) OIL PRESSURE GUAGE of any type and all as specified and directed.
S&F (in repairs) OIL TEMP METER of any type and all as specified and directed.
S&F (in repairs) High Cylinder Temperature (HCT) Switch of any type and size of DG Set and all as specified and directed.
S&F (in repairs) Low lube oil pressure (LLOP) Switch of any type and size of DG Set and all as specified and directed.
M&L for taking down of existing fuel from fuel tank cap 320 KVA DG Sets by any means, removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by using of chemical & detergent with air compressor including rectifing of leakage if found and refixing the same in position as per direction of engineer in charge by testing complete all as specified and directed.
M&L for taking down of existing fuel from fuel tank cap 100 KVA DG Sets by any means, removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by using of chemical & detergent with air compressor including rectifing of leakage if found and refixing the same in position as per direction of engineer in charge by testing complete all as specified and directed.
M&L for taking down of existing fuel from fuel tank cap 20 to 40 KVA DG Sets by any means, removing of sludge and sediments deposited inside the fuel tank by repeatedly washing by using of chemical & detergent with air compressor including rectifing of leakage if found and refixing the same in position as per direction of engineer in charge by testing complete all as specified and directed.
Opening and taking out of cylinder head 320 KVA capcity DG Set Renewal of inlet and exhaust valve, valve guide seats and lapping of valve machining job, pressure testing including renewal of unserviceable parts, reassembling complete testing as requd all as directed.
Ditto all as per item No 49 here-in-before but 100 KVA
Ditto all as per item No 49 here-in-before but 20 KVA to 50 KVA
Renewal of anti viberation mounting pad B series of any type or cpacity complete all as directed.
S&F distilled water in sealed packing for DG 12 volts battery complete all as directed.
S&F in replacement of battery charging sets 12V DC automatic type, fixed in DG set /panel with transformer and rectifier etc including rewiring of faulty control completer all as specified and directed.
S&F in replacement of battery charging sets 24V DC automatic type, fixed in DG set /panel with transformer and rectifier etc including rewiring of faulty control completer all as specified and directed.
S&F in repairs of Automatic voltage Regulator (AVR) suitable for DG Set of 20 KVA to 45 KVA capacity with and including taking out old AVR and making all connection testing for smooth operation complete all as specified and directed. Model No. Tavr-20(k)
S&F in repairs of Automatic voltage Regulator (AVR) suitable for DG Set of 100 KVA capacity with and including taking out old AVR and making all connection testing for smooth operation complete all as specified and directed , Model No. Tavr-20(k)
Ditto all as per item No 56 here in before but 320 KVA , Model No. AVRIVER-2
S&F in repairs Rotating diods assembly suitable for DG set of capacity 40 KVA to 320 KVA with and including taking out old diods and making all connection testing for smooth operation complete all as specified and directed.
M&L for opening /taking out of turbo charger of DG Set of 30 KVA to 100 KVA capacity, disconnection of air supply connection pipe etc complete overhauling servicing of turbo charger renewal of turbo charger repair kit including calibration /testing of turbo charger system complete and re assembling the same fitted with DG set properly in original position checking the alignment making proper all connection testing for smooth operation complete all as directed.
M&L for opening /taking out of turbo charger of DG Set of 320 KVA capacity , disconnection of air supply connection pipe etc complete overhauling servicing of turbo charger renewal of turbo charger repair kit including calibration /testing of turbo charger system complete and re assembling the same fitted with DG set properly in original position checking the alignment making proper all connection testing for smooth operation complete all as directed.
Renewal of Exhaust Muffler of DG Set any type any cap and all as specified and directed.
Renewal of Expension bellow for exhaust of DG Set any type any cap and all as specified and directed.
M&L for carrying out complete overhauling /servicing of DG Set panel, AMF Panel, control panel including checking and rewiring faulty electrical circuit using 1.5 sq mm FRLS copper conductormaking all concections to CTs, push button, digital volt meter, digital amp meter and renewal of LED indicator and testing for smooth operation of any cap and all as directed.
Taking down of old unserviceable exhaust fan fitted in DG set conopy and all as specified and S& F in replacement of suitable size of existing size and capcity all as specified and directed.
Dismantling AC alternator assembly of any capacities including taking out of worn out windings of Rotor and stator incl rewinding the coils with suitable guage of super enamelled winding wire of copper , renewal of insulation materials, heat varnishing, connecting leads and terminal plates all as required to make serviceable of the DG and including reassembling the same after necessary testing all as directed. The item rate includes shifting of altternatos from location to workshop and back to the installation complete all as directed Note : Winding coils of super enameled copper shall be measured & paid separately under relevant item of the schedule/BoQ.
M&L for copper winding for item No-66 above as per existing guage complete all as specified and directed.
S&F (in repairs) Radiator water pump assy 100 to 320 kva capacity complete all as specified and directed.
S&F (in repairs) fuel cap suitable lock & key type of 30 to 320 KVA DG sets all as specified.
S&F in repairs fuel shut down brass solionid valve all as specified and directed
S&F in repairs electronic controller circuit board for engine governorr suitable for 100 to 320 KVA DG Set complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
S & F in repair of 400A, 3 Pole Power contactor cat part No. LCIFDPM5004 with AC coil after fixing checking of proper working condition by rectifing of other inter connected relay, DG set governor controler all as specified and directed. Make : C&S/Legrand/Havells
S&F (in repairs) MCCB, 3 pole, 125 Amps, Icu=25KA, 415 volts, 50 hz, AC , with adjustable thermal and magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F (in repairs) MCCB, 3 pole, 100 Amps, Icu=25KA, 415 volts, 50 hz, AC , with fixed thermal magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
Supplying, fixing and testing (in repairs) 63 Amps, 415V, 4 pole on-load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers including making connections and testing complete all as specified and directed.
Supplying, fixing and testing (in repairs) 100 Amps, 415V, 4 pole off load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers including making connections and testing complete all as specified and directed.
Supplying, fixing and testing (in repairs) 200 Amps, 415V, 4 pole on- load changeover switch with sheet metal enclosure, side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers including making connections and testing complete all as specified and directed.
S&F (in repair) DC alternator after removal of for 12 V DCfrom the DG Set of capacity 30 KVA to 100 KVA , and renewal of minor parts like bush, o ring assembly, bush set, sealing kit, including assembling and re-fixing at site complete all as specified and directed. Note :Major parts if found defected/unserviceable shall be measured & Paid seperately under respective items of Sch 'A'/BoQ
Stator
Rotor
Exicitor
Rectifier plate with diod assembly
Slip ring voltage regulator
S& F (in repair) DC alternator after removal of for 12 V DCfrom the DG Set of capacity 320 KVA , and renewal of minor parts like bush, o ring assembly , bush set, sealing kit, including assembling and re fixing at site complete all as specified and directed. Note :Major parts if found defected/unserviceable shall be measured & Paid seperately under respective items of Sch 'A'/BoQ
Stator
Rotor
Exicitor
Rectifier plate with diod assembly
Slip ring voltage regulator
S&F, testing and commisioning of EMS 555/KG 934/ GC 1211 suitable for DG set of capacity 30 KVA to 320KVA all as specified and directed.
Note for all items if Sch 'A' / BoQ:- (i) The cost of transportation (to and from) for all kind of necessary eqpt /T&P shall be arranged /brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (ii). If any complaint which inform to the contaractor by AGE or JE through telephone or verbal direction and the same will not attend by the contractor with in one day failing which a penality of Rs 1000/- per day will be impossed.
A K JAIN AND SONS
Northern cable fault locatoers
DAVINDER SINGH
Bidder Name
TARA ENTERPRISES
Northern cable fault locatoers
DAVINDER SINGH
A K JAIN AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .