Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC L-1 | |
| 2 | L2₹36.7 L+₹2.7 L (8.08%)Rejected-AOC | L2 | Rejected-AOC L-2 | |
| 3 | L3₹43.4 L+₹9.4 L (27.7%)Rejected-AOC | L3 | Rejected-AOC L-3 |
Tender Value
Refer Docs
EMD Value
₹78,400
Closing Date
24 Feb 2021, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-180003
CERTAIN SPECIAL REPAIR, LBW WORKS, REVENUE WORKS AND MINOR WORKS AT DAMANA UNDER GE JAMMU
2020_MES_396058_3
GEJC-52/2020-21
Open Tender
Job Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹78,400
Yes
31 Mar 2021
11 Feb 2021
26 Feb 2021
11 Feb 2021
24 Feb 2021
12 Feb 2021
Amount
B/R Portion:- Excavation over areas not exceeding 1.5 mtr deep and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep and getting out in any type of soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as mass concrete and filling of foundation complete all as specified and as directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of concrete surfaces in cement mortar 1:4 finished even and smooth surface (without using extra lime or cement) complete all as specified and as directed.
M&L for 5mm thick rendering on fair faces of concrete in cement mortar 1:4 finished even and smooth surface complete all as specified and as directed.
M&L for preparation of newly plastered wall and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
M&L for TMT steel bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed.
All as per Ser item No 8.00 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups complete all as specified and as directed.
M&L for M-25 reinforced cement concrete (using 20mm graded crushed stone aggregate) as in foundations, beams, bases for columns complete all as specified and as directed.
M&L for M-25 reinforced cement concrete (using 20mm graded crushed stone aggregate) as bands complete all as specified and as directed.
M&L for M-25 reinforced cement concrete (using 20mm graded crushed stone aggregate) as in columns, piers, posts complete all as specified and as directed.
M&L for form work to sides of foundation, footings, bases of columns etc finished fair complete all as specified and as directed.
M&L for form work to sides of pillars, posts, struts, piers, columns etc finished fair complete all as specified and as directed.
M&L for form work to sides of floor or roof beams, lintels, cantilevers including supports, overhangs etc complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thickness complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m and depositing at a level not exceeding 1.5m above the strating point complete all as specified and as directed.
S&F PVC (SWR) pipe single socketed in any length with rubber ring joints of size 110mm laid in trenches or in floors or weep hole complete all as specified and as directed.
S&F Pre-painted Bituminous filler board 25mm thick as in crumple joint complete all as specified and as directed.
M&L for preparation of new steel and iron based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F mild steel screw bolts of dia 16mm with hexagonal head at one end and screwed the other. Each screwed end to be fitted with washers and length of bolt exceeding 15cm and not exceeding 22.5cm long complete all as specified and as directed.
S&F mild steel work as in angle iron for fencing, post struts including flat iron strip, cutting top to shape as directed, drilling holes for nuts and bolts etc embedded in concrete and fixed independently, without connecting plates, etc (cut to ordinary lengths) complete all as specified and as directed.
S&F Galvanised min 140gsm 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at cross rings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and as directed. (Each line wire to be measured).
S&F for razor punched tape Concertina coil of dia 600mm (before stretch) 55 turn per coil and after expanding the effective coil length 10m running length per coil and appx weight of each coil is 9 Kgs, the coil wire should be min 250 gsm GI wire of dia 2.90mm wire with 0.4mm thick 250 gsm GI punched tape with 3 clipping points and GI clips complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, in soft or loose soil complete all as specified and as directed.
M&L cement concrete 1:3:6 type C-2 (using 40mm crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S&F Joist, channel, Angle or Tee section fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410-W (gde E-250) quality - A as in fencing post complete all as specified and as directed.
S&F mild steel work of angle iron as in framed work such as cooler stand, grills, gratings etc with ends of bars shouldered and / or riveted, or forged into spikes; conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for brick work in cement mortar 1:6 using sub class 'B' bricks straight or curved on plan exceeding 6m mean radius complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No 29.00 here-in-before but except bricks complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in lintel up to 1.5m clear span, cills, copings / benching, kneelers, apex stone, bed plates etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L concrete cement 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in surface channel and drain complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement, including forms, moulds, mitred / stopped ends etc (inner girth only measured) complete all as specified and as directed.
Demolition of septic tank >200 users and <500 users, built in brick masonery work with cement mortar or cement lime mortar including RCC slab of any description and dimensions and necessary excavation of any type of soil and removing unserviceable material, soil to as distance exceeding 100 mtr complete all as specified and as directed.
M&L for Construction of septic tank for 250 users exceeding in ordinary soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole covers having 6mm plate embedded all round / fibre reinforced cover with angle iron frame Vent Shaft and sludge chamber etc as shown in Drg No CEPZ-C-TD-13/01-05 complete all as specified and as directed.
M&L for Soakage wells exceeding in ordinary soil, foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in CM, RCC cover slab in M-25 / RR masonry / Filling with brick bats, complete of size 2.5 M dia X 4.5 M deep complete all as specified and as directed.
Removing excavated soil up to as distance 1.5Km and depositing where directed complete all as specified and as directed.
M&L for Concrete bed to drain pipes of bore 200mm dia including packing under haunching against the sides of pipe after they are laid tested in cement concrete 1:4:8 type C-2 (using 40mm graded crushed stone aggregate) complete all as specified and as directed.
M&L for 200mm internal dia salt glazed stone ware drain pipe Class 'A' laid in trenches on concrete bedding jointed in cement mortar 1:1 complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for Pre-cast RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in manhole cover slab fixed in position including necessary form work and set in CM 1:6 complete all as specified and as directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) n.exc. 1.5 sqm including cutting holes for taking out hold fast or dismantling brick (holes cut and any other damage to jambs, wall for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt) complete all as specified and as directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc. 1.5 sqm but n.exc. 4 Sqm each including cutting holes for taking out hold fast or dismantling brick (holes cut and any other damage to jambs, wall for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt) complete all as specified and as directed.
Dismantling asbestos cement (corrugated or semicorrugated etc) sheets in roof covering complete all as specified and as directed.
Dismantling timber scantling 40 sq.cm and over in section, framed work of any description complete all as specified and as directed.
M&L for clean sawn timber in fixed second class soft wood in scantlings complete all as specified and as directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quions, arcehs, pillars etc and removing unserviceable material exceeding 100 mtr complete all as specified and as directed.
M&L pressed steel frames for door (factory made) out of 1.25mm thick black MS sheet, with one or more rebates including necessary fixing lugs, butt hinges, lock strike plate, etc complete, size of frame 105 X 60mm including bottom of each chowkhat to be welded with 2 No's 25 X 25 X 3mm thick flat iron projecting 10cm on either side and back fill to chowkhats with PCC 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregate) including one shop coat of red oxide primer complete all as specified and as directed.
S&F for 35mm thick 2nd class hard wood plain framed, panelled shutter (two panel) of factory made with lock rail and panel of 12mm thick veneered particle board with commercial veneering on both faces including wooden beads on both sides, one coat of pink primer. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F steel window 1.25mm thick Box type (Primer coated) ERW hollow P section of size 60 X 25mm single rebated comprises glazed Skelton shutter ERW sec 50 X 20mm and 1mm thick with two No's sash bar of T-section 20mm X 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 60 X 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 four No for each window including following fitting welded to frame shutter hold fast of 150mm long of 12mm X 3mm FI made to shape 4 No, handle of Z section 20mm X 25mm X 100mm long 1 No per leaf, MS tower bolt 150mm long, 2 No per leaf, Z sec 20mm X 25mm, 100mm long stopper 1 No on per leaf, MS pintal hinges of size 75mm X 12mm 2 No per leaf fabrication and fixing arrangement as per drg No CEPZ/TD-324, 325/07 complete all as specified and as directed.
S&F Mild Steel work of flat iron, Square bar, round bar etc. as in framed work such as grills, guard bars, gratings etc including bending, cutting and welding as necessary of confirming to Fe 290-0 Gde-E-16 including one shop coat of red oxide primer complete all as specified and as directed.
S&F 3mm thick sheet glass ordinary quality glazing with steel pins, oil putty to steel windows and beads nails etc to wooden surfaces as in square exceeding 0.50 Sqm in each pane complete all as specified and as directed.
Dismantling boarding of any description fixed in any position with nail complete all as specified and as directed.
S&F for frame work for ceiling with specification as under mentioned: - (i) GI section frame work (Powder coated) for white, pre-premiered, self embossed, reinforced designer board consisting of perimeter wall angle 19mm X 19mm X 0.45mm, cross 'Tee' 28.6mm (web) X 24mm flange 0.33mm thick powdered coated main tee 38mm (Web) X 24mm flange 0.33mm thick. Wall angle shall be screwed / fixed to brick wall / partition wall / concrete / RCC with the help of nylon sleeves and screws @ 610mm C/C, then suspending GI main 'Tee' in both directions by means of hangers with alignment @ 1220mm C/C to soffits. To from grid of 610 X 610mm cross Tee shall be provided @ 610mm C/C in both directions and all suitable provisions shall be made for fixing the recssed / surface mounting light fittings if any, complete all as specified and as directed by Engr-in-charge.
S&F for 4mm thick non asbestos fibre cement building boards 60 X 60cm in size including two coat of white wash after preparation of surface, fixed / laid / inserted to GI frame work at ceiling with screws complete all as specified and as directed.
M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls or from concrete surface including racking out joints, hacking for key, scrubbing with water etc complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing to be finished even and smooth without using extra cement complete all as specified and as directed. (including all necessary scaffolding, lifting arrangement).
M&L preparation of old plastered surface including filling of small holes etc and applying one coat of cement based paint complete all as specified and as directed by Engr-in-Charge.
M&L for two coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L preparation of old plastered surfaces by scrapping down smoke dust and removing oily and greassy spots etc and applying one coat of white wash on walls complete all as specified and as directed.
M&L for preparation of new wood or wood based surfaces and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L for preparation of old wood or wood based surfaces and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for one coat of synthetic enamel paint after preparation of old surfaces of steel of any description not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving's not exceeding 15cm thickness (below or above ground level) and removing unserviceable material exceeding 100 mtr complete all as specified and as directed.
M&L for 50mm thick cement concrete 1:2:4 typ B-1 (using 20mm graded crushed stone aggregate) complete all as specified and as directed by Engr-in-Charge.
M&L for 20mm thick wear proof topping as specified (incorporating an approved metallic floor hardener), laid on concrete floors and pavings and finished even and smooth complete all as specified and as directed by Engr-in-Charge. Note:- Metallic floor hardener shall be measured and paid separately.
Supply only metallic floor hardener complete all as specified and as directed.
M&L 75mm thick PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection etc finished even and smooth without using extra cement complete all as specified and as directed.
E/M Portion:- Taking down Old / UNSV copper / aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit complete all as specified and as directed.
Taking down DB's, main switches etc of any size making good disturbed surface of wall / floors etc complete all as specified and as directed.
Taking down LT cable of any size in walls, trenches etc and making good to the disturbed surfaces of walls / floors etc in any size complete all as specified and as directed.
M&L for point wiring for one light/fan poiint/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips complete all as specified and as directed by Engr-in-Charge.
All as per Ser Item No 74.00 here-in-before but for multi 5 pin 5 Amp socket outlet on same board complete all as specified and as directed.
All as per Ser Item No 74.00 here-in-before but for multi 3 pin socket outlet 5 Amp socket on independent board complete all as specified and as directed.
All as per Ser Item No 74.00 here-in-before but for one 3 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
S&F in repair socket outlet 5 Pin 5A, flush type complete all as specified and as directed.
S&F in repair angle / batten lamp holder on PVC Square Blocks with PVC insulated body complete all as specified and as directed.
S&F in repair LED Bulb 9 watt 240 Volts complete all as specified and as directed.
S&F in repair switch paino flush button single pole one way 5 Amps complete all as specified and as directed.
M&L for distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engr-in-Charge. Note: - Distribution board and MCB's should be of same make.
S&F in replacement new generation energy saving, wall mounted LED Tube light batten fittings, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver 20 Watt LED 6500K (4' ft long) with LED rod 20 watt, 230 Volts, 50 Hz complete all as specified and as directed.
S&F in repair MCB single pole and Neutral 32 Amp suitable for 240 Volt, 'B' series complete all as specified and as directed.
S&F in repair MCB single pole 6-32 Amps suitable for 240 Volts, 'B' series complete all as specified and as directed.
S&F in repair switch paino flush button single pole one way 15 Amps complete all as specified and as directed.
S&F in repair socket outlet 3, 5 pin and 15 Amp multipurpose shuttered type complete all as specified and as directed.
S&F in repair for fan regulator stepped electronic type suitable for AC 240 V complete all as specified and as directed.
Supply and laying or fixing or passing through pipe 1100 Volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sqmm nominal cross section 2 core in service connection complete all as specified and as directed.
M&L in repair for Earthing complete with galvanised steel earth plate electrode 60 X 60cm X 6.3mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protection by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with CI cover wih suitable angle frame and handle, GI light grade 20mm bore pipe for watering, perforated at bottom, 1.75 mtr long placed on top edge of earth plate, charcoal and common salt filling, funnel, wire mesh and earth work in hard / dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtr all as per electric plate No 5 of SSR part-I and connecting to earth test point all as specified including testing on completion.
S&F in repair LED street light fittings 45 Watt powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass with lens complete with suitable bracket, clamps and suitable length twin core wire including taking out old UNSV from pole complete all as specified and as directed. Note:- Rate is inclusive of bracket of suitable size made of GI medium grade pipe 1.2 mtr long bend to shape 120 degree and fixing with 2 No's of suitable sizes clamps, including nuts, washers, bolts complete fittings.
M/S PRAJAPATI ENGINEERS
M/S STAR CONSTRUCTIONS
Bidder Name
M/S PRAJAPATI ENGINEERS
M/S STAR CONSTRUCTIONS
M/S A K CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .