Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC NO 6 G 2 SS ENCLAVE 1ST MAIN 1ST CROSS INDIAN EXPRESS LAYOUT VIRUPAKSHAPURA VIDYARANYAPURA POST BANGALORE 560 097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹34.3 L+₹1.9 L (5.81%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹37.0 L+₹4.6 L (14.2%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹38.3 L
EMD Value
₹76,600
Closing Date
4 Feb 2025, 6:00 pmClosed
COL A K TRIPATHI, CWE
CWE (ARMY) BANGALORE, 101, DICKENSON ROAD, BANGALORE - 560042
SPECIAL REPAIRS TO ROOF TREATMENT AND SUNKEN FLOOR OF TOILET (ONLY 2ND FLOOR) OF BLDG NO P-337 (AV HAJIPIR TRG COY) UNDER GE (NORTH) BANGALORE
2025_MES_691374_1
86360/E8
Open Tender
Civil Works
Item Rate
150 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹76,600
10 Mar 2025
2 Jan 2025
11 Feb 2025
2 Jan 2025
4 Feb 2025
16 Jan 2025
2 Jan 2025 - 9 Jan 2025
Amount
Dismantling water tanks of capacity exceeding 2000 & n exc 3000 litres complete fixed on roof of any height and all as directed.
S&F Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) 2500 Litres capacity in position complete on roof of 10 m height complete all as specified and as directed.
S&F 25mm dia ball valves(Minimum weight 25mm-455gms) high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed.
S&F 25mm dia Nipple suitable for HDPE water tank (Minimum weight 25mm- 65gms) complete all as specified and as directed.
Taking up or down 25mm to 32mm dia steel tubing and connections, including removal complete from trenches /wall etc all as specified and as directed.
Supplying and laying of 32mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S&F in repairs 32mm CPVC ball valve / gate valves, with lever , screwed both ends for iron pipe and fixed complete all as specified and as directed.
Taking down of existing Water Proofing treatment of any type (APP Membrane,Cement or earthen tile,Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirts etc over padding concrete by grinding, Picking, sweeping clean and washing down with water to remove dust & for providing surface for water prooling treatment complete all as directed.(Note : Quoted rate shall be deemed to be inclusive of removing debris outside defence land)
Demolition & removal of cement concrete/padding concrete of any description and in any position not otherwise specifically provided for complete all as directed.(Note : Quoted rate shall be deemed to be inclusive of removing debris outside defence land)
M&L for providing cement concrete (1:2:4) type B-0 using 12.50mm graded crushed stone aggregate as in padding concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for 10 mm thick Screed bed or bedding/plaster in CM (1:3) with WPC, finished plastered surface even and smooth without using extra cement complete all as specified and as directed.(Note :- WPC will be measured and paid separately)
Supply only liquid water proofing compound
M& L for providing Water proofing treatment complete all as specified and directed as under :- (i) Preparation, cleaning RCC roof surface (ii) Applying of compatible primer/bonding bitumen @ 0.40 Litr/Sqm. (iii) Laying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017 , 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black with torch applications of membrane with 75mm side overlap and 100mm end lap as per manufacturer's instructions (iv) Applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm
M&L for providing cement concrete (1:5:10) type E2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete for sunken floor including Demolition of cement concrete exc 15 cm thickness but above ground floors including removal of debris from MD Land complete all as specified and as directed.
Material and labour for water proofing to sunken portions of WCs, bathroom and kitchen etc by applying water based, cold applied, single component, elastomericin-situ seamless monolithic coating ready to use acrylic modified bituminous liquid membrance with the procedure in sequence complete all as specified and as directed with the following stages. SURFACE PREPARATION (i) Removing all loose gravel, dirt, oil, grease and foreign matter by jet of dry air and cleaning the surface mechanically or by grinding to make it smooth before application. (ii) Repairing all cracks by cutting “V” groove and fill with PMC mortar prepared in the ratio of Shalicrete : cement : sand (1:2:5) or equivalent. (iii) Providing 50 mm x 50 mm coving made out of PMC mortar as above. MATERIAL PREPARATION (i) Stir TarFelt ® LM or of equivalent make by a slow speed mixture (approx. 400 rpm) fitted with a suitable mixing paddle to ensure a homogenous mix. (ii) After stirring, wait for the product to settle in order to let entrapped air escape. WATERPROOFING APPLICATION (i) Slightly damp the surface. Avoid standing water / ponding. (ii) Prime the surface with a mixture of TarFelt® LM or of equivalent make and potable water in the ratio of 50:50 and apply @ 400 grm / m2 of the mixture and allow it to touch dry. (iii) Apply first coat of TarFwlt® LM @ 0.70 kg / m2 or of equivalent make by brush / roller / airless spray while the primed surface is tracky, For faster and smoother application, airless spray is preferred. (iv) Spread fiber glass net of 45 gsm with overlap of 50 mm in both directions when the surface is till tackty. (v) Allow 1st coat to dry for 10-12 hrs. (vi) Apply second coat of TarFelt® LM @ 0.70 kg m2 or of equivalent make by brush / roller / airless spray for final DFT of 1000 micron in two coats inclusive of fibre glass of 45 gsm (theoretical coverage depending on surface conditions). (vii) Sprinkle sand @ 200 grm / m2 over the final vertical coating when the surface is still tackty to facilitate plastering. (viii) Ensure final curing time of 36 hrs before allowing / carrying out any further work. (ix) Conduct ponding test after 7 days of curing at ambient temperature.
Taking down chowkat (without taking of shutter from the frame) not exc 1.5 sqm each complete all as directed
S& F Solid PVC door frame (Single rebated) of size 60 mm x 30 mm made out of solid foam with homogenious fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on approved manufacturer drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete all as specified and directed.
M & L for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing given in SSR Part II with wood free EPS complete all as specifide and as directed.
M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specifide and as directed.
S&F Anodised aluminum powder coated (of any shade/colour as approved by GE ) ventilators of Size 500mm x 800 mm) with adjustable 4mm thick figured glass louvers, fixed in qtr portion, without sash bars, aluminum section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, including stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.18mm etc complete all as specified and as directed.
M & L Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings shown by GE and as directed.( Note: Supply only 4 mm thick sheet glass and wire mesh be measured and paid separately).
M & L for Aluminium Deco grill powder coated (minimum 50 micron coating) of No DG-104 not less than 6mm thick, weight not less than 2.507Kg/sqm, riveted to panel of frame using U channel all as specified and as directed.
Supply & Fixing Sheet glass 4mm thick ordinary quality and glazing with oil putty or in wooden /steel /aluminium /rubber beading in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply & fixing stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm and fixed with tinned tack or galvanized wire staple complete all as specified and as directed.
S & F Butt hinges stainless steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed.
S&F Aluminium anodised tower bolt 150mm long of extruded section etc complete all as specified and as directed.
S&F 125 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed.
Supply & laying 20 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified and as directed.
Supply & laying 25 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified and as directed.
S&F in repair Vitreous China wash basin, white, oval type, size 550mm x400mm including 32 mm dia brass waste coupling ,chromium plated fancy type swan neck pillar taps, waste pipe, 600 mm long PVC connection & brackets including cutting for and pinning in ends of brackets or erecting stand with corrugated PVC waste pipe 800mm long complete all as specified and as directed.
S&F in repair Vitreous china wash down water closet pan ( pedestral Pattern) white, (Including flushing cistern and flush pipe ) , including connection to drain & or out going pipe ) and to flushing pipe, anti syphonage pipe, seat and cover for pedestral pan including 10 litr PVC flushing cistern and 450 mm long PVC connection etc complete all as specified and as directed.
S& F Vitreous China squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm white, with integral foot rests including PVC SWR P trap 10 litre PVC flushing cistern,600 mm long PVC connections connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor, fixed in repairs complete all as specified and as directed.
S&F in repairs Vitreous China half stall urinal flat back, size of 630 mm x 390mm x 420mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe ) but including Concussive push button taps of cast copper alloy, screwed for iron pipe, PTMT waste coupling suitable for urinals, (Minimum weight 32mm-45gms urinal spreader and 450 mm long PVC connection and PVC urinal waste pipe complete all as specified and as directed.
S&F in repairs 15mm stop valves/ angle valves cast copper alloy, screwed down, high pressure, fancy type,chromium plated screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs 15mm stop valves cast copper alloy, screwed down, high pressure, fancy type,chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs 15mm bib tap, standard of CP fancy type,chromium plated any colour high pressure screwed for iron pipe complete all as specified and as directed.
S&F in repairs15mm two way bib cock with angle valve combination brass chromium plated, complete all as specified and as directed.
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position including taking down old complete all as specified and as directed.
S&F in repairs 125mm dia brass chromium plated shower rose with swivel joints complete all as specified and as directed.
S & F in repairs Towel rail 600 mm long stainless steel glossy finish complete all as specified and as directed.
S&F in repairs Soap dish of standard size chromium plated brass all as fixed in wall complete all as specified and as directed.
S&F in repairs Toilet paper holder with flat recessed type stainless steel complete all as specified and as directed.
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, urinal partitions and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,including cutting and polishing laid on and including 15 mm thick screed bed in CM (1:4) set and jointed including dismantling of old stone slabs laid bedded and pointed in any mortar complete all as specified and as directed.
M & L for Providing edge moulding to 18-20mm thick granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed.
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
M & L 25mm thick cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregates) as in floor finished even as in levelling concrete complete all as specified and as directed.
Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing rubbish off from premises complete all as directed.
M&L Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including Screed bed or bedding layer of mortar 15 mm thick in CM (1:4) for laying floor finishes complete all as specified and as directed.
M & L Glazed ceramic tiles in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & including 10mm thick in screed CM (1:4) on brick work or concrete surfaces to receive wall tiles complete all as specified and as directed.
S & F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary fittings complete all as specified and as directed.
S & F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors including necessary fittings complete all as specified and as directed.
S & F in repair 110 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary fittings complete all as specified and as directed.
S & F in repair 110 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors including necessary fittings complete all as specified and as directed.
S&F 75mm dia PVC (SWR) Bends with access door of any radius complete all as specified and as directed.
All as per item no 55 above but 110mm dia and -ditto-
S&F 110mm dia PVC (SWR) Bends of any radius complete all as specified and as directed.
S&F 75mm PVC (SWR) branch piece, (single Y) equal or unequal complete all as specified and as directed.
S&F 75mm PVC (SWR) branch piece, (double Y) equal or unequal complete all as specified and as directed.
S&F 110mm PVC (SWR) branch piece, (single Y) equal or unequal complete all as specified and as directed.
S&F 110mm PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and as directed.
S & F PVC (SWR) vent cowl 110mm complete all as specified and as directed.
S & F in repair 75mm dia PVC(SWR) floor trap,plain with grating including jointing with solvent cement complete all as specified and as directed.
M & L for Complete removal of existing treatment on wall surfaces chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent approved brand as specified in CA) over a coat of weather proof primer including filling the minor cracks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
Demolition of brick/stone/boulder /precast concrete articles and precast concrete block built in cement mortar etc complete all as directed.
M&L for Pre-cast cement concrete block masonry(1:3:6) , type C1 (using 20mm graded crushed stone aggregate) as in CM (1:6) with solid blocks,exc 10cm in width and setting in mortar, complete all as specified and as directed.
Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land complete all as specified and as directed.
M&L for Rendering(Internal Surfaces) 15mm thick in CM (1:6) on brick or concrete surfaces , finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surfaces with WPC, finished plastered surface even and smooth without using extra cement (External Surfaces) complete all as specified and as directed.( Note :- WPC will be measured and paid separately)
M&L for Rendering 5 mm thick in CM (1:3) on ceiling surfaces , finished even and smooth with out using extra cement complete all as specified and as directed.
M & L for Preparation of new plastered surfaces and applying three coats of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
M & L for Preparation of newly plastered surfaces of wall/chajjas etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
M & L Preparation of newly plastered surfaces and applying three coat of white wash on walls including in narrow widths/ bands etc complete all specified and as directed.
M & L Preparation of old decorated surfaces and applying one coat of white wash on walls including in narrow widths/ bands etc complete all specified and as directed.
M & L Preparation of old decorated surfaces and applying one coat of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed.
M & L for point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed in walls including MS terminal boxes fabricated with 1.6mm thick M S sheet concealed on walls with laminated sheet top cover 3mm thick fixed with cadmium plated iron screws for housing switches, switch socket outlets, fan regulators etc., including provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :-
One light point controlled by one switch and -ditto-
One fan/exhaust point controlled by one switch/regulator and -ditto-
One 3 pin socket out let 5 A on same board and -ditto-
One 3 pin socket out let 5 A on independent board and -ditto-
M & L Point Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed in walls including MS terminal boxes fabricated with 1.6mm thick M S sheet concealed on walls with laminated sheet top cover 3mm thick fixed with cadmium plated iron screws for housing switches, switch socket outlets, fan regulators etc., including provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for independent socket outlet all as specified and as directed. Note for item No 77 & 78 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for concealed wiring to be included in point wiring
S & F in repair LED batten suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories complete all as specified and as directed. (Make: Bajaj, Cat No.BCLAB 18 WH LED P or equivalent Makes as approved by GE of Makes in Philips/CG/Havells.)
S&Fin repair of switch piano flush type single pole one way 5 Amps complete all as specified and as directed.
S&Fin repair of switch socket combination 5 pin 2 in 1, 5 A Flush type complete all as specified and as directed.
S&F in repair of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal complete all as specified and as directed.
S&F in repair MCB SPN 240 volts 32 Amps "C" series complete all as specified and as directed
S&F in repair MCB single pole 240 volts 6 to 32 Amps "C" series complete all as specified and as directed
Supply and fix in repair Stepped type electronic Fan regulator, 120W flush type complete all as specified and as directed.
S&F in repair MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar complete all as specified and as directed.
S&F in repair ceiling rose, surface bakelite type 65 x 50 mm, three terminals complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, including test point complete all as specified and as directed.
S&F in repair 30W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection complete all as specified and as directed. (Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent make as approved by GE of Makes in Philips/CG/Havells.)
S&F in repair Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm , etc complete all as specified and directed. (Make : Bajaj cat No : 70079, MAXX AIR or equivalent Make in Havells/CGs/ Orient as approved by GE)
Taking up the following bores old UNSV GI pipes from ducts/culverts/road/path etc complete all as directed :-
(a) 50 mm dia
(b) 25 mm dia
S&F of steel water tubing 50 mm bore medium grade, galvanised, with all fittings, laid in trenches ducts/culverts/road/path/wall complete all as specified and directed. (Note: Excavation and earth work shall be measured and paid for separetely).
As per item No. 93 above but for 25 mm dia and -ditto-
S&F in repair Gun metal Gate valve of size 25 mm dia with iron wheel complete all as specified and directed.
S&Fin repair Gun metal Gate valve of size 50 mm dia with iron wheel complete all as specified and directed.
S&F in repair Float valve of size 20 mm dia with PVC body aluminium float rod, nylon float high pressure type complete all as specified and directed.
B5BUILDING SOLUTIONS (BID ID -3226873)
K. VENKATESH NAIDU (BID ID -3230561)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .