Loading…
Loading…
Tender ID
Tender Value
₹1.7 L
EMD Value
₹3,380
Closing Date
4 Apr 2026, 11:15 amClosed
YOGESHWAR
HSVP DIV 1 Sec 8 Panchkula
Replacement of Contractor Block LandT BCH Over Load Relay SDz5 Timer at various Pumping Installation in Sec 20 and Replacement of Unserviceable Control Panel at TWell No. KV 8 in Sec 20 Panchkula
2026_HBC_511405_1
20269BB3EBA7 B579 4963 BA36 E5E7A2E04C1A269HSV
Open Tender
Civil Works
Works
30 days
Panchkula
Please refer Tender documents.
2 documents required · 2 mandatory
₹250
Yes
₹3,380
Yes
27 Mar 2026
27 Mar 2026
6 Apr 2026
27 Mar 2026
4 Apr 2026
27 Mar 2026
27 Mar 2026 - 2 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 123.22.1.5:- Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA | |||||
| 220.114.6:- Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 6. 35 HP Motor [Through Rate] | |||||
| 320.114.9:- Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 9. 50 HP Motor [Through Rate] | |||||
| 4NS Item:- Providing & Fixing of Contractor Block MNX 80 L&T Make as Per Satisfaction of Engineer-in-Charge & attesting on load | |||||
| 5App. Item:- Providing & Fixing of Overload Relay MN12 CT Operated 60-100 Amp. L&T make satisfaction of Engineer-in-Charge & attesting on load. | |||||
| 6NS Item:- Providing & Fixing of Copper wire multistand 35 sq mm | |||||
| 7NS Item:- Providing and Fixing of Single phase preventor LandT/Minilac make as per satisfaction of Engineer-in- charge and attesting on load to the entire satisfaction of EIC. | |||||
| 8NS Item:- Providing and Fixing of SPPR type SDz5 Timer 415 volt make LandT complete in all respect to the entire satisfaction of EIC and attesting on load. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_590202.xls
BOQ • 0.25 MB
AD0156651.pdf
Additional Documents • 2.17 MB
OT0156651.pdf
Other Document • 0.09 MB
corrigendum596.pdf
PDF • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .