Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC 00 C O PARMOD SINGH BAKTA BARHI CHINTAMAN SITAMARHI BIHAR 843315 | SITAMARHI | BIHAR | 843315 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹17.7 L+₹74,760 (4.40%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹18.2 L+₹1.2 L (7.28%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹21.2 L+₹4.2 L (24.6%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹22.6 L+₹5.6 L (33.2%)Rejected-Finance 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L5 | Rejected-Finance BEING L5 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
7 Sept 2022, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR/MAINT OF DG SET, AMF PANEL, E/M EQPTS ,SECURITY LIGHT CONTROL PANEL, CABLE, HIGH MAST DISTRIBUTN SYSTEM FOR SECURITY LIGHT, GARDEN LIGHT AND REPAIR/MAINT/RENEWAL OF EARTHING, LIGHTNING ARRESTER AND ALLIED WORK AT SITE R AFS UNDER GE AF THANE
2022_MES_544354_1
8216/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹44,000
Yes
16 Dec 2022
9 Aug 2022
8 Sept 2022
9 Aug 2022
7 Sept 2022
26 Aug 2022
9 Aug 2022 - 26 Aug 2022
Amount
Material and labour for earth pit chamber of size 0.6mx0.6mx0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chamber of size 200 mm depth, 300mm length and 300mm width ,complete all as specified and as directed by Engr-in-charge.
Material and labour for Brazzing of copper earth strip 20/25/32 mm with available at site and reconnected properly ,complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable and dislocated Copper/aluminium strip of any size from floor of any size height ,complete all as specified and as directed by Engr-in-charge.
S&F,copper strip of 20 x 3.15 mm as roof conductor and down conductor till test point all as directed. Note-Copper strip to be jointed through brazing only ,complete all as specified and as directed by Engr-in-charge.
S&F,aluminium strip of 25 x 3.15 mm as roof conductor and down conductor till test point all as directed. Note-Galvanised strip to be jointed through brazing only
Taking down unserviceable and dislocated air termination rod of any type from floor of any size ,complete all as specified and as directed by Engr-in-charge.
S&F,single pointed soild copper rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/down conductor ,complete all as specified and as directed by Engr-in-charge.
S&F, single pointed soild Aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor ,complete all as specified and as directed by Engr-in-charge.
S&F Porcealing insulators in replacement for fixing Copper strip on wall / Roof bldg with necessary screws washers and nut bolts etc all Specified . Note - Rates are inclusive of copper screws with washers for fixing copper strip on porciline insulator with minimum size 1 inch and maximum size 1.5 inch with max external dia of screw is 8mm and 2 nos of GI nut for fixing insulator on wall all as per site requirement ,complete all as specified and as directed by Engr-in-charge.
S&F,in repair,Medium grade GI pipe of 20 mm dia for fixing air termination rod, the pipe shall be suitably tapered for fixing the saddle insulator at an interval not exceeding 0.5 meter, the pipe should be laid vertically and should be properly supported, length of each vertically pipe should not exceed 3 RM, the air termination rod, down conductors should be insulated from the pipe all as directed.
S&F,in repair, test terminal block made with gun metal size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head of gun metal screw ,complete all as specified and as directed by Engr-in-charge.
M&L for earthing complete with Copper earth plate electrode 600x 600x 3.15 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber using 1:3:6 type C2 for earthing pit , CI cover with necessary frame , protection pipe of size 15mm dia and watering pipe of 20mm bore medium grade, funnel, mesh etc all as required at site and all as directed. Note: (i) 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii) Earth resistance of earth pit should be less than 2 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (iv) Soil registance test if required shall be the responsbility of contractor without any extra cost. (v) PCC chamber shall be constructed at least 1.5mtr away from the earth electrode and pipe for watering shall be slanting manner.
M & L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel with provision of charcoal and salt 15cm thick all around bottom and top of earth plate as shown in as per electrical plate No 3 of SSR Part-I including PCC 1:3:6 type C2 for earthing pit, GI light grade protection pipe of size 15mm dia ,CI cover and frame necessary earth works and PCC work and water arrangement with GI pipe 20mm dia (medium grade) including excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion .(Note:1.After completion if test results are not satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor quoted rate deemed to be included with testing.3. PCC chamber shall be constructed at least 1.5mtr away from the earth electrod and pipe for watering shall be slanting manner 4. (ii). Earth resistance of earth pit should be less than 2 Ohms)
S&F,in repair, copper strip of 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground Complete all as specified and directed by Engg.in.Charge
S&F ,in repair, Bib taps, for 15 Bore dia of pipe , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed ,complete all as specified and directed.
S&F first aid box complete with all necessary medicine complete all as specified and directed by Engineer-in-Charge.
S&F colour first aid chart of size not less than 50x70 cm,Billangual( English & Hindi) complete laminated and pasted on cardboad with hanging arrangment on wall ,complete all as specified and directed by Engineer-in-Charge.
S&F colour Shock treatment chart of size not less than 50x70 cm,Billangual( English & Hindi) complete laminated and pasted on cardboad with hanging arrangment on wall, complete all as specified and directed by Engineer-in-Charge.
S&F in repair, steel tubings of medium grade including all necessaory fittings i.e. socket, elbow etc.laid on floor or fixed to wall of size 15mm dia all as directed.
S&F in repair, GI steel tubings of medium grade including all necessaory fittings i.e. socket, elbow etc.laid on floor or fixed to wall of size 20mm dia all as directed.
S&F Mild Steel Sheet of size approximate 300x200x1.6mm thick Sheet Egg type, Half round type, Rectangular type and Triangular type with welded 1ʺ (Inch) dia 2ʹ (Feet) long Mild Steel Pipe with duly different Synethic Enameled Paint cutting of Equipment Earthing/ Lighting Arrester Earthing/ Signal Earthing, etc. complete as specified duly painted as specified and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date including taking down unserviceable one, complete all as specified and as directed.
M&L for Cutting existing 15 mm steel tubing for alterations or additions (Each cut measured) complete all as specified and directed.
M&L for Cutting existing 20 mm steel tubing for alterations or additions (Each cut measured) complete all as specified and directed.
M&L for periodical testing and measuring the earth resistance value of the existing earthings / Down conductor / air terminal by means of wheat stone bridge method after disconnecting the earth continuity conductor from the test point , applying secondary voltage across the terminals, maintaining proper record of the measurement in presence of the users rep, MES rep, submitting the test records, pouring saline water in the earth pit to achieve low earth resistance, observing the same complete for Quarterly Building earthings,L2/L3 eqpts/E&M installations/Lightning arresters test ,complete all as specified and as directed by Engr-in-charge. (Note -(i) Item rate include the cleaning dust/dirt from earth pit chamber, common salt and funnel shall be measured and paid for separately under respective items as supply only (ii) Equipments used for measuring shall be arranged by contractor at his own cost nothing shall be paid extra)
Supply only Common Salt commercial type
Supply only Funnel with wire mesh of size suitable for 20 mm dia watering pipe.
Supply and providing Electrician with helper for repair the unserviceale street light/ aviation light including taking down High Mast Light and taking up High Mast machanically/ Post Lamp fittings/ Garden Light, Gate light and reflixing the same in existing postion including testing after repair complete all as directed. Note: (a) Necessary spare, fitting, excavation other related work will be measured in respective items of Sch A as a supply only. (b) Necessary tools, ladder, safty equipment for electrifican and helper will be arrange by the contractor in his own cost
Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 30 watt, complete all as specified and as directed
Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 45/60 watt, complete all as specified and as directed
Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and as directed
Supply only Surge Protection Device of capacity 10KV Single Phase 50Hz, complete all as specified and as directed.
S&F Multi LED Street Light fitting of capacity 30 Watt IP 65, having Die-cast Aluminium Housing, weather proof with Accessories and connecting up with and including PVC insulated Copper Conductor cable 1.5 Sqmm, single core including Taking down unserviceable Street light fitting from the Electric pole, complete all as specified and as directed.
S&F Multi LED Street Light fitting of capacity 45 Watt IP 65, having Die-cast Aluminium Housing, weather proof with Accessories and connecting up with and including PVC insulated Copper Conductor cable 1.5 Sqmm, single core including Taking down unserviceable Street light fitting from the Electric pole, complete all as specified and as directed.
M&L Inegaral Decorative LED 8 Watt Bollard Energy saving, Environmental friendly aesthetically designed with opal acrlylic with IP-65 proctection, providing electric connection with suitable PVC copper flexible conductor, providing PCC 1:3:6 (20mm graded aggregate) work of size 300x300x450mm including necessary formwork and earth work, complete all as specified and as directed .
Supply & fixing in replacement Integral LED aviation light 30 watt comprising of aluminium housing with polycarbonate enclosure with IP-65 protection complete all as specified and as directed by the Engr-in-Charge.
Supply, fixing and testing LED Flood light fitting of 120 Watt in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report .
Supply only LED Bulb 15 for Integral pole mounted decorative LED post top with spherical/GLOBE shaped, 240 V 50Hz complete all as specified and directed.
Supply, fixing and testing Post top lantern of 25/45 Watt in repair/replacement of existing lights including LED lamps, acrylic, canopy totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report including suitable size of GI pipe for post with PCC 1:3:6 complete all as specified and as directed by the Engr- in- Charge.
All as per Item No 38.00 above but Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp base 20 Watt.Make - Havells Cat part No LHFXBON1TN5Q020 , Bajaj BLPTSP 25W NW LED or equivalent.
S&F Lithium based Energy Efficient integrated Solar Street Light 32 Watt in Single FRP Body encases Solar PV Panel 64/66 Wp Monocrystalline, Lithium Battery 11.1/12.8 Volt, 33 AH with in-built BMS, High brightness Watt - LED (160 to 180 Lumen/Watt) Lamp, CRI>70, Color Temperature 6500 K, Micro Controller based Charge Controller cum Friver, Automatic Dimming function with PIR Motion Sensor, Dusk and Down Operation, Working Temperature : (-)10 °C to (+)55 °C, Weight 18-20 Kg with adjustable Mild Steel Clamp suitable for Pole/Wall mounting with protection: Short circuit, Overload, Reverse Polarity and Battery Protections. Maunfacturer should produce Vital Parameters Test Report from NABL or Accredited Lab and should be made in india with CE & ROHS Tested and Certified and connecting up with Copper Conductor Cable of suitable size including Taking down unserviceable Street Light Fittings from Pole, complete all as specified and as directed. MAKE :HAVELLS/BAJAJ/CROMPTON GREAVES/PHILIPS
Relaying Old serviciable XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No.02 here-in-before) 1100 Volt grade, cross sectional area 35 Sqmm to 50 Sqmm, 3½/4 Core after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.(Note : Old serviciable XLPE cable obtained from relevent item of Sch A shall be used against this item).
Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 10 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 16 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 25 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Supply & Laying/Fixing XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 35 Sqmm 3.5 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing ,complete all as specified and as directed by Engr-in-charge .Make: Sintex/Hensel/National
M&L for for applying two coat of Cement based paint on PCC poles of street lights of ant description up to including 9 m overall length including preperation of old painted surface of PCC Poles all as specified and directed. Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
M&L for for applying two coat of Silver paint on GI poles of street lights of ant description up to including 9 m overall length including preperation of old painted surface of G I Poles all as specified and directed. Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) as in Copping of Electric Poles, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling PCC Copping and/or removing damaged PCC Copping, complete all as specified and as directed.
M&L GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 METRE long bent to shape as per specified for fixing Street Light Fitting including applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket, complete all as specified and as directed. MAKE : BST/ JINDAL/ PRAKASH TUBES/ TATA
Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications.
S&F PVC insulated Multi Stranded FRLS-H Copper Conductor Cable 1.5 Sqmm, Single Core for connection of Street Light Fitting including Taking down unserviceable Cable of any description, complete all as specified and as directed.
S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting including Taking down unserviceable Cable of any description, complete all as specified and as directed.
Making Hole under Road/ Hardstanding including cutting, etc. with manual anger or bookie not exc. 100mm dia, complete all as specified and as directed.
S&F in replacement of pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coat of Silver paint over a coat of primer in alternate strip of 30cm each in white and blue colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
S&F in replacement of heavy duty GI pole for Solar street light, 6 meter long erecting truly in vertical position including painting of poles with two coat of Silver paint over a coat complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, struts & mass concrete including necessary form work and fair finishing to exposed surfaces complete all as specified and directed by Engineer-in-charge
M&L Galvanised Steel Tubing Pipe 50 mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L for hardcore of broken stone boulder, gauge not exc. 63 mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 3 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. seggrating Serviceable Cables, Pipes, Bricks, etc. incuding Serviceable Pipes, Bricks, etc. and keep in Safe Custody for re-use including removing Unserviceable Cables to MES Store Yard and depositing/stacking properly, complete all as specified and as directed. NOTE : Necessary Earth Work will be measured and paid under appropriate Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Taking up reinforced precast concrete cable cover any class any type with any size complete all as specified and directed by Engr-in-charge.
Supply and laying un reinforced precast concrete cable cover class LV type-II, flat size 250mmx150mmx 40mm laid in trenches complete all as specified and directed by Engr-in-charge.
Relaying of reinforced precast concrete cable cover class LV type-II, flat size 250mmx150mmx 40mm laid in trenches complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications.
S&F Specification Board (Acrylic) size of 914x610x8mm and fornt size of letter not less than 72mm and words which is pasted on acrylic sheet not exceeding 100 nos with suitable hanging arrangement on wall complete as specified and as directed by Engr-in-Charge.
M&L for Sevicing,repair maintenance including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing deposits and preparetion of surface for painting checking of its all parts for serviceability and reassembling all serviceable parts all as original including replacement of defective parts and minor spares required for functioning of DG set 100 KVA Make : Cromptom Greaves/GE/Cumins/Kirloskar Green complete engine testing on load to the entire satisfaction of Engr-in-Charge. Note :-1. All major defective/unserviceable spare parts/items reqd for replacement shall be measured and paid seperately under appropriate items mentioned in Sch 'A' as supply only. 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Supply only spare parts of DG Set model Make – Cromptom Greaves/GE/Cumins/Kirloskar Green of capacity 100KVA for replacing of unserviceable parts for satisfactory functioning of engine complete all as directed by Engr-in-Charge.for the following:-
Fuel filter element with existing cat part (primary & secondry).Make:Kirloskar/Bosch/Mico
Lube oil filter element with existing cat part. Make:Kirloskar/Bosch/Mico
Radiator hose pipe set with clamp complete.Make:Kirloskar/Bosch/Mico
Water temperature guage with existing cat part. Make:Kirloskar/Bosch/Mico
Oil temperature guage with existing cat part. Make:Kirloskar/Bosch/Mico
Oil pressure gauge with existing cat part. Make:Kirloskar/Bosch/Mico
Fan belt with existing cat partt. Make:Kirloskar/Bosch/Mico
Starting ignition switch with existing cat part. Make:Kirloskar/Bosch/Mico
Push Button with existing cat part. Make:Kirloskar/Bosch/Mico
Packing Kit with existing cat part. Make:Kirloskar/Bosch/Mico
Techometer with cable with existing cat part. Make:Kirloskar/Bosch/Mico
Fuel pipe any type length and specification with existing cat part. Make:Kirloskar/Bosch/Mico
Air filter element of existing specification with existing cat part. Make:Kirloskar/Bosch/Mico
Battery charging meter 12 VDC.Make:Kirloskar/Bosch/Mico
Hose pipe (for make up water connect).Make:Kirloskar/Bosch/Mico
Hose thermostate to radiator.Make:Kirloskar/Bosch/Mico
11.5" dry type air cleaner.Make:Kirloskar/Bosch/Mico
Digital voltmeter 0-500V with existing cat part.
Digital ammeter 0- 100 A with existing cat part .
Digital frequency meter 50HZ with existing cat part.
M&L for Sevicing, repair maintenance including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing deposits and preparetion of surface for painting checking of its all parts for serviceability and reassembling all serviceable parts all as original including replacement of defective parts and minor spares required for functioning of DG set 82.5 KVA Make :Cromptom Greaves/GE/Cumins/Kirloskar Green complete engine testing on load to the entire satisfaction of Engr-in-Charge. Note :- 1.All major defective/unserviceable spare parts/items reqd for replacement shall be measured and paid seperately under appropriate items mentioned in Sch 'A' as supply only. 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Supply only spare parts of DG Set model Make – Cromptom Greaves/GE/Cumins/Kirloskar Green of capacity 82.5 KVA for replacing of unserviceable parts for satisfactory functioning of engine complete all as directed by Engr-in-Charge.For the following:-
Fuel filter element (primary & secondry).Make:Kirloskar/Bosch/Mico
Lube oil filter element.Make:Kirloskar/Bosch/Mico
Radiator hose pipe set with clamp complete.Make:Kirloskar/Bosch/Mico
Water temperature guage.Make:Kirloskar/Bosch/Mico
Oil temperature guageMake:Kirloskar/Bosch/Mico
Oil pressure gauge.Make:Kirloskar/Bosch/Mico
Fan belt set.Make:Kirloskar/Bosch/Mico
Starting ignition switch.Make:Kirloskar/Bosch/Mico
Push Button.Make:Kirloskar/Bosch/Mico
Packing Kit.Make:Kirloskar/Bosch/Mico
Techometer with cable.Make:Kirloskar/Bosch/Mico
Supply and replacement of Air filter element of existing specification.Make:Kirloskar/Bosch/Mico
Hose thermostate to rediator.Make:Kirloskar/Bosch/Mico
11.5" dry type air cleaner Make:Kirloskar/Bosch/Mico
Digital voltmeter 0-500V .Make; HPL or equivalent to ISI as approved By GE
Digital ammeter 0- 100 A. Make; HPL or equivalent to ISI as approved By GE
Digital frequency meter 50HZMake; HPL or equivalent to ISI as approved By GE
M&L for Sevicing,repair maintenance including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing deposits and preparetion of surface for painting checking of its all parts for serviceability and reassembling all serviceable parts all as original including replacement of defective parts and minor spares required for functioning of DG set 15 KVA Make : Cromptom Greaves/GE/Cumins/Kirloskar Green,complete engine testing on load to the entire satisfaction of Engr-in-Charge. Note :- 1.All major defective/unserviceable spare parts/items reqd for replacement shall be measured and paid seperately under appropriate items mentioned in Sch 'A' as supply only. 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Supply only spare parts of DG Set model Make – Cromptom Greaves/GE/Cumins/Kirloskar Green of capacity 15 KVA for replacing of unserviceable parts for satisfactory functioning of engine complete all as directed by Engr-in-Charge. For the following:-
Fuel filter element (primary & secondry).Make:Kirloskar/Bosch/Mico
By pass filter element.Make:Kirloskar/Bosch/Mico
Water temperature guage.Make:Kirloskar/Bosch/Mico
Oil pressure gauge.Make:Kirloskar/Bosch/Mico
Fan belt set.Make:Kirloskar/Bosch/Mico
Fuel pipe any type length and specification.Make:Kirloskar/Bosch/Mico
Air filter element of existing specification.Make:Kirloskar/Bosch/Mico
locking arrangment with keys of existing specification
Engine oil 20W40 Suitable for DG Set Complete all as spd.
Coolent AFC 30% Suitable for DG Set Complete all as spd.
M&L for Repair/overhauling and calibration of fuel injection pump complete with replacement of worn out parts such as bearing plunger, impeller and oil seal etc including re-fixing fuel injector pump all as directed.
Material and labour for repair to radiator opening of inlet outlet hose connection including cleaning of complete radiator and repair if any leakage by soldering welding and refitting testing of 100/62.5/15KVA capacity Diesel engine complete all as specified and directed by Engr-in-Charge
M&L for Repair / calibration of nozzle assembly replacement of worn out parts injector top, springs etc all as specified and directed by Engr-in-Charge.
Repair of self starter including replacemet of burn field coil replacement of armature and carbon boush holder and carbon bush point of any capacity and of DG set complete all as specified and directed by Engg.in.Charge
M&L for Dismantling of alternator parts of DG set 100 KVA 3 phase 4 wire ,AC 415 Volts, such as statrter & rotor cores, excitor & field coils rectrifies assembly, fan etc. including rewinding of starter field, replacement of exciter assembly and automatic voltage regulator, varnising and damage worn out insulation, cleaning all part by blower, servicing rewiring & varnishing etc. grease of reqd grade to bearing reassembling and testing complete all as spd and directed by Engg.in.Charge
Dismantling of alternator parts of DG set 82.5 KVA 3 phase 4 wire ,AC 415 Volts, such as stator & rotor cores, excitor & field coils rectrifies assembly, fan etc. including rewinding of stator field, replacement of exciter assembly and automatic voltage regulator, varnising and damage worn out insulation, cleaning all part by blower, servicing rewiring & varnishing etc. grease of reqd grade to bearing reassembling and testing complete all as spd and directed by Engg.in.Charge.
Dismantling of alternator parts of DG set 15 KVA 3 phase 4 wire ,AC 415 Volts, such as stator & rotor cores, excitor & field coils rectrifies assembly, fan etc. including rewinding of stator field,replacement of exciter assembly and automatic voltage regulator,varnising and damage worn out insulation, cleaning all part by blower, servicing rewiring & varnishing etc. grease of reqd grade to bearing reassembling and testing complete all as specified and directed by Engg-in-Charge.
Taking down and Supply, Fixing, Testing AVR for DG Set 100/82.5/15 KVA, 3 phase 4 wire, AC 415 Volts, 50Hz to sense the voltage in the main generator winding and control the power fed to the exciter stator and the main rotor to maintain the generator output voltage with in the specified limits, compensating for load, speed, tempreture and power factor complete with existing make & specification all as specified and directed by Engg-in-Charge.
Taking down unserviceable change over switch and Supply and fixing on load change over switch 100 amps, 415 volt AC, complete all as directed.
Taking down unserviceable change over switch and Supply and fixing on load change over switch 200 amps, 415 volt AC, complete all as directed.
M & L for dismantling existing unseviceable defective parts of smoke detector, maunual call point and fire alarm system and refixing of serviceable parts all as spd and directed.
S&F in replacement of detectors Complying with and type certified to EN - 45 addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as directed.
S&F in replacement of detectors Complying with and type certified to EN - 45 addressable type heat detector with base with rate of rise cum fixed temperature as per lS:2175 complete all as directed.
S&F in replacement of detectors Complying with and type certified to EN - 45 addressable manual call point resettable type complete all as directed.
S&F Solar LED Street Light Fitting of capacity 50 Watt with Motion Sensor based, Peak Lux Sensor on 37@7M, Eco friendly, User friendly, no UV/Mercury, Pressure Die Cast Aluminium Body, Maintenance Free Lithiumion Batteries of suitable capacity dully intenally fitted, Solar Panel Mono Crystalline Photo Voltaic Module of capacity 75 Watt with all Accessories and connecting up with Copper Conductor Cable of suitable size including Taking down unserviceable Street Light Fittings from Pole, complete all as specified and as directed.
S&F DG Set power bank of capacity 12 Volts, 180 Ah complete with autobat invatower heat sealed low maintenance battery made with low antimony selenium alloy (LASA) in positive and negative elctrodes,Instant cranking,high density with extreme power with and including polyethylene envelope separators with glass mat vibration resistant for longer life complete all as spd and directed by Engg.in.Charge.Make: Exide gen plus/Okaya/Luminous
S&F DG Set power bank of capacity 12 Volts, 88 Ah complete with autobat invatower heat sealed low maintenance battery made with low antimony selenium alloy (LASA) in positive and negative elctrodes,Instant cranking,high density with extreme power with and including polyethylene envelope separators with glass mat vibration resistant for longer life complete all as spd and directed by Engg.in.Charge.Make: Exide gen plus/Okaya/Luminous
AMC FOR DG set 100 KVA, Make: Kirlosker through authorise service agency of OEM. Location: AFS HQ Area.Scope Of Work :- (a) Engine Cooling System :- Checking of radiator ,V belts, enging oil,hoses connections , fan pulley, water pump,vibration of engine, belts tension,water level sensor and necessary rectify the defect if found. (b) Engine Fuel System :-Checking fuel lines connections,piping, clamps, hose, etc.governors ,electronic governing system,priming pump,fuel filter and necessary rectify the defect if found. ( c) Engine Lubricating System Inspection :-Checking oil lines connections and rectify any signs of oil leak, loose connections, corroded piping, defective clamps, deteriorated hose, etc.Checking oil pressure condition and rectify any sign of erratic operation, defective gauges, defective pressure sensors, defective wiring harness, etc.Checking oil level & oil quality condition.Checking oil condition . (d) Engine Air Induction System :-Checking air filter indicator reading and repair/replace defective sensor, air filter,.Checking hoses & connections (e) Engine Exhaust System :-Checking the exhaust manifold condition,exhaust pipe insulation if found any abnormal then rectify according. (f) Engine Electrical System :-Checking batteries condition,electrolyte level, distilled water level. (g) Generator Control Panel System Inspection :- Checking “start / stop / manual switch condition & functionality.Checking “voltmeter”, “Ammeter”, “frequency meter, “Contactors,“wiring termination for proper tightness, indicating lamps, fault/tripping circuits and necessary rectify the defect if found. (h) AMF Panel :- Checking the all connection of contractor, MCCB, cable connection and rectify the defect if found any. NOTE:- DHPP(N) shall be provide by department under Sch B for this item for free for consumption & any major spare parts required for maintanence shall be measured and paid seperately in respectively items of Sch A.
All as per Srl Item No-95.00 above but for 82.5 KVA Make kirloskar Location Technical area Site R
All as per Srl Item No-95.00 above but for 15 KVA Make Kirloskar Location AFNET Site R
Inspection/checking & testing after repair of AMF panel of 15 KAV DG set 440 voltage 50Hz AC,to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,MCB's.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMF panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage. (Notes :-This items includes the cost of cleaning & rewiring of panel. Spare parts required shall be measured and paid for separately under respective items as supply only)
S&F MCCB 415 Volts, 35 KA, 3 Pole 160 Amps,complete all as specified and directed by Engineer-in-Chrage.
S&F MCCB 415 Volts,16 KA, 4 Pole 63 Amps,complete all as specified and directed by Engineer-in-Chrage.
S&F MCCB 415 Volts,35 KA, 4 Pole 100 Amps,complete all as specified and directed by Engineer-in-Chrage.
S&F MCCB 415 Volts,35 KA, 3 Pole 200 Amps,complete all as specified and directed by Engineer-in-Chrage.
S&F MCCB 415 Volts,35 KA, 3 Pole 250 Amps,complete all as specified and directed by Engineer-in-Chrage.
S&F electric contactor suitable for AMF panel of DG Set 100 KVA, 3 phase 4 wire, AC 415 Volts, 50Hz as existing make and capacity ,complete all as specified and directed by Engineer-in-Chrage.
S&F electric contactor suitable for AMF panel of DG Set 82.5 KVA, 3 phase 4 wire, AC 415 Volts, 50Hz as existing make and capacity ,complete all as specified and directed by Engineer-in-Chrage.
S&F Danger notice plate for HT side of the fancing of size 20cmx25cm of 1.6mm thick mild steel viteous enamelled white with letters, figure and conventional skull and bones "DANGER" etc. in signal red colour and fixed with MS clamps made out of 25mmx3mm MS plat iron bolts, nuts complete including two coats of aluminium paint over a coat of red oxide primer ,complete all as specified and directed by Engineer-in-Chrage.
Supply & Fix Black colour rubber mat made EPDM Rubber (Ethylene Propylene Diene Monomer Rubber) suitable for sub station of size 1200mmx900mmx15.5mm for protection to shock,complete all as specified and directed by Engineer-in-Chrage.
SKY HIGH TECH ENTERPRISES
Saviour Security Systems
Biju Construction & Co
EVEREST POWER CONTROL ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .