Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹15.7 L+₹3.2 L (25.2%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹17.4 L+₹4.9 L (39.0%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
29 Dec 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT OF E/M NATURE OF WORK INCLUDING REPAIR AND REPLACEMENT OF U/S WIRING AND FITTING AND FIXTURES AT OTM AND MD ACCN OF KHANPUR DUNDAHERA AND MANESAR ARMY CAMP INCLUDING REPAIR/ REPLACEMENT OF GEYSERS AND CONNECTED ITEMS AT VRC 10 JAK
2020_MES_390664_2
GE/DS-49/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹40,000
Yes
4 Feb 2021
8 Dec 2020
31 Dec 2020
8 Dec 2020
29 Dec 2020
15 Dec 2020
9 Dec 2020 - 14 Dec 2020
Amount
Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repair(s) etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repair(s) such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/ internal circuits of existing electrical system of main building/block and making continuous electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed. Notes :- This item is applicable only where no store is required. 1. Two electrician shall be provided by the contractor for attending daily complaints on working days including holidays/ sunday and shall report to MES complaint cell at 8:30 Hrs. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The MES department is not responsible for the payment of electrician as all the items of CA are to be supply and fixed by the contractor. 4. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 5. A recovery of Rs. 500/- per person shall be recovered from the contractor for non deploying of electrician on any day. 6. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 7. Proper record (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produce for verification at the time of payment of each RAR/Bill.
S&F in replacement of switch piano flush type 6 Amps SP one way complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of switch piano flush type 6 Amps SP 2-way complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement bell push, flush type 6 Amps complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of socket outlet 6 Amps flush mounted piano type 5 pin multi purpose complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of switch piano type 16 Amps SP one way complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of socket outlet 2 in 1 (multipurpose) 6 pin 6 and 16 Amps flush mounted type complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of bell Ding dong 230 volts single phase complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of fan regulator electronic, stepped type, Switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of fan condenser 2.5 Mfd complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of fan condenser 3.15 Mfd complete all as specified and as directed by Engineer-in-Charge.
S&F inverter based LED Glass Bulb 09 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/SK light fittings in replacement old unsv CFL fitting any watt complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Comfortable wall light suitable for LED Bulb B-22 Cap complete all as specified and as directed by Engineer-in-Charge. Make:- Cat LHFHCHE1TL1W020 of Havells or its equivlent C&S /CG/Bajaj/Phillips
S&F in replacement of LED 6 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and as directed by Engineer-in-Charge. Make:- Cat LHKL01160099 of Havells or its equivlent make in C&S /CG/Bajaj/Phillips).
S&F LED Batten T-5 fitting 20 watt LED White, indoor decorative aluminum extruded T5 LED battern -integrated type in replacement of old unsv existing 36 Watt tube light fitting, complete all as specified and directed. Make:- Cat Part No LTTB4F20WLED/W of Make : C&S or equivalent Havells/Halonix/Philips/CG
S & F LED Integrated Batten T5 10 watt - 2FT White, indoor decorative aluminum extruded T5 LED battern -integrated type complete with including fliexble wire in replacement of old unsv existing 18 Watt tube light fitting. complete all as specified and directed by Engineer-in-charge.Make:- Cat Part No LTTB2F10LEDP/W of Make : C&S or equivlent Havells/Bajaj/Philips/CG.
S&F Surface mounting round/square shaped LED downlighter with PDC aluminum housing 6 Watt LED lamp in replacement of old unsv existing CFL fitting any type from ceiling of stairs/common areas, complete all as specified and as directed by Engineer-in-Charge. Make : Havells, Cat part No. LTCRSUR6HPLEDRND/W OF C&S or equivalent in Bajaj/Philips/CG/Havells.
S&F LED Building security light fitting 45W on existing bracket in replacement of old unsv existing security light fitting any type complete all as specified and as directed by Engineer-in-Charge. Make:- Cat Part No LTESSI45WLED/LS of C&S or its equivalent Havells/CG/Bajaj/Phillips)
S&F in replacement Circuler Hylam/PVC Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) including screws and cup washer complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour. complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed in green colour complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of submain wiring of two runs of 2.5 Sqmm size for main cable and one run of 2.5 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and directed by Engineer-in-charge. (Note: Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length)
S&F in replacement of for submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and directed by Engineer-in-charge. (Note: Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length)
Taking down of ceiling fan/ exhaust fan/ wall mounted fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete. Note:- Rewinding will be measured and paid under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement of gun metal bush, ball bearing where ever required. Note:- Gun metal bush and bearing will be measured and paid under respective item of this Schedule.
All same as per ser item No. 27 above but here-in-before ceiling fan 1400 mm sweep
All same as per ser item No 27 above but here-in-before exhaust fan 450 mm sweep
All same as per ser item No 27 above but here-in-before exhaust fan 300 mm sweep
All same as per ser item No 27 above but here-in-before wall fan 350/400 mm sweep
S&F in replacement Gun metal bush for fans complete all as specified and directed by Engineer-in-charge.
S&F in replacement Ball bearing of suitable size & model for ceiling/Exhaust fan complete all as specified and directed by Engineer-in-charge.
S&F in replacement clamp with rubber real for hanging ceiling fans of 1200/1400mm sweep as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with one no MCB SP upto 20 Amps as per site requirement of existing type complete all as specified and directed by Engineer-in-charge.
M&L for aluminium lugs of size 6 Sqmm to 16 sqmm for connecting PVC cable complete all as specified and directed by Engineer-in-charge.
M&L for aluminium lugs of size 25 Sqmm to 95 sqmm for connecting PVC cable complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB DB SPN 4 Way double door type,(IP 43 Protection) flush mounting complete all as specified and directed by Engineer-in-charge Make:- Legrand Cat No. 607710 or equivalent of ABB /Crabtree )
S&F in replacement MCB DB SPN 8 Way double door type,(IP 43 Protection) flush mounting complete all as specified and directed by Engineer-in-charge. Make:- Legrand Cat No. 607711 or equivalent of ABB /Crabtree)
S&F in replacement MCCB 3 Pole 415V, Adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 3 pole, 415V, Adjustable type,125 Amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-charge.
S&F Recessed/Surface Mounting 36 Watt 2'x2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for POP ceiling supplied with wedge bracket to fix in existing POP ceiling including cutting/grouting of existing POP ceiling in replacement of existing old unserviceable CFL fitting any type from ceiing of stairs/common areas and making good a disturbed surface/POP ceiling to match with POP and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engineer-in-charge. Make : Halonex Cat Part No (Model) - HLFPR22-02-36-CW-R, 140-270V AC or its equivalent in Bajaj/Philips/C&S/Havells
S&F in replacement for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement for MCB SPN/DP 40 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement for MCB SPN Double Pole 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB TPN/ Isolator 4P 100 Amps 415 volts, 'C' Series 10 KA as per site requirement complete all as specified and directed by Engineer-in-charge.
Taking down carefully the old u/s Aluminium/ Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, call bell etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including concealed PVC conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet (ISI Marked) of required color with screwed and cup washer with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified and directed by Engr-in-Charge Note:- The rate is inclusive cutting /chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash.
One light / fan/bell point controlled by one switch SP, one way, 230 volts.
One 3 pin socket outlet 5/6 Amps on same board.
One socket outlet 5/6 Amps on independent board.
One power socket 15/16 Amp but with cable 4 Sqmm for phase & neutral and for earth 2.5 sqmm on independent board.
S&F in replacement distribution board vertical triple pole and neutral 4 way, double door for fixing MCCB upto 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified and directed by Engineer-in-charge. Make : Legrand Cat part No:- 607790 or its equivalent ABB/Crabtree
S&F in replacement MS fastner bolt 8mm dia and 100mm (Min.) long for fixing geyser/ Exhaust fan/Bldg security light etc with nut and washer complete all as specified and directed by Engineer-in-charge.
Taking down geyser 25/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element 1.5 KW for any make of geyser of 25 litres capacity as per sample complete all as specified and directed. Make Micronking/Theeta/Standard
S&F in replacement heating element 2 KW for any make of geyser of 50 litres capacity as per sample complete all as specified and directed. Make Micronking/Theeta/Standard
S&F in replacement thermostat ( 11 inch Long) for 25/50 ltrs capacity geysers complete all as specified and directed by Engineer-in-charge.
S&F in replacement indicating lamp round / flat type as required for geyser 25/ 50 litres capacity complete all as specified and directed by Engineer-in-charge.
S&F in replacement safety valve ISI marked for geyser 25/50 litres capacity complete all as specified and directed by Engineer-in-charge.
S&F in replacement safety plug for geyser 25/50 litres capacity complete all as specified and directed by Engineer-in-charge.
S&F in replacement PVC connection with brass nipple 15 mm x 450 mm long for geyser 25/50 ltrs capacity complete all as specified and directed by Engineer-in-charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 25 litres cap as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket for any make of geyser of 50 litres cap as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement 25 Ltr inner stainless tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engineer-in-charge.
S&F in replacement 50 Ltr inner stainless steel tank suitable for 50 Ltr storage water heater complete all as specified and directed by Engineer-in-charge.
M&L for welding /brazing the inner shell made out of stainless steel /copper sheet for geyser 25/50 ltrs capacity and make the shell water tight including testing complete all as specified and directed by Engineer-in-charge. Note:-Taking down, de-scaling, replacement of rubber gasket and any minior repair involved will be mesured and paid seperatly.
S&F in replacement Rubber gasket for water heater storage type of any capacity fixed and suitable as per the existing, complete all as specified and directed by Engineer-in-charge.
M&L Top & Bottom cover body suitable for 25 Ltrs storage water storage heater made of MS sheet complete as per site requirement complete all as specified and directed by Engineer-in-charge.
M&L Top & Bottom cover body suitable for 50 Ltrs storage water storage heater made of MS sheet complete as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement submersible water lifting pump,single phase suitable for desert coolers complete all as specified and directed by Engineer-in-charge.
S&F in replacement cooler fan motor 1/7 HP or any HP 230 volt,50Hz cycles A/C supply complete all as specified and directed by Engineer-in-charge.
S&F in replacement capacitor, 4 mfd rating complete all as specified and directed by Engineer-in-charge. Make - Epcos/tibcon/universal
S&F in replacement wood wool pad (set of 3) suitable for 18 inch sweep desert cooler of good quality complete all as specified and directed by Engineer-in-charge.
M&L for refilling of gas in 1.5 Ton AC including necessary arrangement for gas filling.R-22 complete all as specified and directed by Engineer-in-charge.
M&L for refilling of gas in 320 ltr capacity Deep Frzeer including necessary arrangement for gas filling R-134A complete all as specified and directed by Engineer-in-charge.
S&F in replacement compressor for deep freezer of capacity 320 ltr complete all as specified and directed by Engineer -in-charge
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for outer body suitable of 25 Ltrs storage heater made of MS sheet as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement for outer body suitable of 35/50 Ltrs storage heater made of MS Sheet all as per site requirement complete all as specified and directed by Engineer-in-charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
verma enterprises
Ashish Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .