Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 LQualified Make: NEC
Model: NEC SL2100 LAITUMKHRAH SHILLONG MEGHALAYA 793003 | EAST KHASI HILLS | MEGHALAYA | 793003 | Make: NEC
Model: NEC SL2100 | ₹1.6 L | L1 | Qualified |
| 2 | Disqualified Make: NEC
Model: NEC Sl2100 245B SECOND FLOOR SANT NAGAR ISKCON ROAD EAST OF KAILASH SOUTH DELHI DELHI 110065 | SOUTH EAST DELHI | DELHI | 110065 | Make: NEC
Model: NEC Sl2100 | - | - | Disqualified |
| 3 | Disqualified Make: NEC
Model: NEC SL 2100 18 39 FF LSC DDA MARKET DAKSHINPURI EXTENSION SOUTH DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | Make: NEC
Model: NEC SL 2100 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
18 Jun 2018, 4:00 pmClosed
pbx Average Turn Over of Last 3 Years 125 Lakh (s) Experience with Gov. Required 12 Year (s) Pbx ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION FEATURES Number of analog Extensions 48 8
12
16
24
32
40
48
64 Number of CO/analog trunks 6 1
2
3
4
6
8
NA System expadable upto (TDM ports) 64 16
64 Provision for digital phone extension true - If YES
number of digital extensions 8 2
NA GENERAL FEATURES Call Pick-Up Feature true - Conference Feature true - CLI - Transferable + Internal(DTMF/FSK) Available - Do Not Disturb(DND) true - Call Forward Feature - in 3 different conditions true - Call Parking Feature true - Call Waiting Feature true - Hold Music true - 1/5 Memory Dialing Feature true - Distinctive Ringing Feature true - Auto Call Back Feature true - Redial Feature true - Auto Attendant true - Emergency Call Feature true - Auto Call Disconnection Feature true - Date/Time Setting true - Boss Secretary Call Feature true - Day/Night Mode true - Auto-Attendant messages Welcome message
Extension message
No answer message - Voice Mail Available - Number of Auto attendant messages 3 - Other features - - GENERIC Dimensions(H×W×D) 120x80x180 - Weight - - Mounting of PBX Both - PROTECTION Protection against over current and over voltage on the output side Yes - POWER SUPPLY/BATTERY Power Requirement 230V
+/-10%
50Hz - Battery Backup Available - If available
battery backup time (Hour) 2 - Inbuilt Battery charger Available - Chemistry of battery SMF - Battery capacity (AH) 12 - OPERATING CONDITIONS Minimum Operating Temperature(Degree C) 5 - Maximum Operating Temperature(Degree C) 50 - Operating Humidity(RH) 90 - 2/5 WARRANTY Warranty 1 1
5 INSTALLING&COMMISSI ONING Installation & Commissioning With With
Without Scope of the installation as per STC of the product YES - MANUAL AND ACCESSORIES The scope of supply include one set of operation and maintenance manual for each equipment YES - TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications NA - If Available
TEC approval Certificate number - - Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to specifications true - Conformity to Dry Heat test at Specified Maximum Operating Temperature for 16 hours as per IS :9000 latest true - Conformity to Cold test at Specified Minimum Operating Temperature for 4 hours as per IS: 9000 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true - Test Report number and date - - Name and Address of the Test lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jeltrudis Lyngkhoi 793021
Ministry of 1 15 3/5 Environment
Forest and Climate Change
Law U Sib
Near MTC Workshop
Shilong-793021 EMD Required No ePBG Required No
213343
GEM/2018/B/30368
pbx
Meghalaya; East Khasi Hills
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| pbx Average Turn Over of Last 3 Years 125 Lakh (s) Experience with Gov. Required 12 Year (s) Pbx ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION FEATURES Number of analog Extensions 48 8 | - | - | - |
| 12 | - | - | - |
| 16 | - | - | - |
| 24 | - | - | - |
| 32 | - | - | - |
| 40 | - | - | - |
| 48 | - | - | - |
| 64 Number of CO/analog trunks 6 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 8 | - | - | - |
| NA System expadable upto (TDM ports) 64 16 | - | - | - |
| 64 Provision for digital phone extension true - If YES | - | - | - |
| number of digital extensions 8 2 | - | - | - |
| NA GENERAL FEATURES Call Pick-Up Feature true - Conference Feature true - CLI - Transferable + Internal(DTMF/FSK) Available - Do Not Disturb(DND) true - Call Forward Feature - in 3 different conditions true - Call Parking Feature true - Call Waiting Feature true - Hold Music true - 1/5 Memory Dialing Feature true - Distinctive Ringing Feature true - Auto Call Back Feature true - Redial Feature true - Auto Attendant true - Emergency Call Feature true - Auto Call Disconnection Feature true - Date/Time Setting true - Boss Secretary Call Feature true - Day/Night Mode true - Auto-Attendant messages Welcome message | - | - | - |
| Extension message | - | - | - |
| No answer message - Voice Mail Available - Number of Auto attendant messages 3 - Other features - - GENERIC Dimensions(H×W×D) 120x80x180 - Weight - - Mounting of PBX Both - PROTECTION Protection against over current and over voltage on the output side Yes - POWER SUPPLY/BATTERY Power Requirement 230V | - | - | - |
| +/-10% | - | - | - |
| 50Hz - Battery Backup Available - If available | - | - | - |
| battery backup time (Hour) 2 - Inbuilt Battery charger Available - Chemistry of battery SMF - Battery capacity (AH) 12 - OPERATING CONDITIONS Minimum Operating Temperature(Degree C) 5 - Maximum Operating Temperature(Degree C) 50 - Operating Humidity(RH) 90 - 2/5 WARRANTY Warranty 1 1 | - | - | - |
| 5 INSTALLING&COMMISSI ONING Installation & Commissioning With With | - | - | - |
| Without Scope of the installation as per STC of the product YES - MANUAL AND ACCESSORIES The scope of supply include one set of operation and maintenance manual for each equipment YES - TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications NA - If Available | - | - | - |
| TEC approval Certificate number - - Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to specifications true - Conformity to Dry Heat test at Specified Maximum Operating Temperature for 16 hours as per IS :9000 latest true - Conformity to Cold test at Specified Minimum Operating Temperature for 4 hours as per IS: 9000 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true - Test Report number and date - - Name and Address of the Test lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jeltrudis Lyngkhoi 793021 | - | - | - |
| Ministry of 1 15 3/5 Environment | - | - | - |
| Forest and Climate Change | - | - | - |
| Law U Sib | - | - | - |
| Near MTC Workshop | - | - | - |
| Shilong-793021 EMD Required No ePBG Required No | - | - | - |
Exempted
18 Jun 2018
15 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_213343.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .