Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.5 LAccepted-AOC 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹21.5 L+₹54,615 (2.61%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹22.5 L+₹1.6 L (7.41%)Rejected-Finance | 3 | Rejected-Finance Not being lowest |
Tender Value
₹25.9 L
EMD Value
₹51,900
Closing Date
20 Jan 2023, 6:00 pmClosed
HQ CWE Agra
112 Taj Road Agra Cantt
REPAIR / MAINT OF LT NETWORK, LT PANELS AND LT SWITCH GEAR AND OTHER ALLIED WORKS AT FATEHGARH CANTT
2022_MES_570967_1
86132/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Fateghar
MES contractors enlisted in Class D category b(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹51,900
Yes
13 Mar 2023
23 Dec 2022
27 Jan 2023
23 Dec 2022
20 Jan 2023
6 Jan 2023
23 Dec 2022 - 30 Dec 2022
Amount
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning to U/G cable in layers of 23 cm thick( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned down volume shall be measured.
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
Taking out unserviceable LT U/G cable from trenches of size 6 Sqmm to 120 Sqmm 2/3.5/4 core complete all as specified and as directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 120 Sqmm 3.5 core complete all as specified and directed.
All as per item No - 7 but size 95 Sqmm 3.5 core
All as per item No - 7 but size 70 Sqmm 3.5 core
All as per item No - 7 but size 50 Sqmm 3.5 core
All as per item No - 7 but size 25 Sqmm 4 core
All as per item No - 7 but size 16 Sqmm 4 core
All as per item No - 7 but size 6 Sqmm 2 core
Dismantling of overhead ACSR conduction of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse serviceable ACSR in the work & removing unserviceable conductor from site complete all as specified & as directed.
M & L for straining of Aluminium conductor steel reinforeced (ACSR) on over head LT electric line required sag and binding the conductor with insulator and jumper with aluminium binding wire conforming to IS:398 Part-II complete all as specifie and as directed.
All as per item No.15 above, but refixing and restringing serviceable ACSR (any size) as recovered from item No.14 here-in-before including binding wire, line taps etc complete all as directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as reqd. and removing the same from site complete all as specified & as directed.
S & F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Pt-1 with using stay rod of 16 mm dia complete all as specified & as directed.
Dismantling of insulators of any type & size from position including separating & setting a side serviceable insulators for reuse in the work & removing unserviceable insulator from site complete all as specified & as directed.
S & F pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade complete all as directed.
All as per item No-20, but fixing only old serviceable pin type insulator as obtained from item No.19 here in before.
S & F shackle type porcelain vitreous white, brown or green insulator of size 75 mm height 90 mm dia including MS strips 31x3 mm washers, insulator bolts 12 mm dia & nuts suitable for working pressure 1100 volts grade complete all as specified and directed.
All as per item No- 22 above , but fixing oly old serviceable shackle type insulator as obtained form item No. 24 here-in-before
M & L MS clamp made out of 50x6 mm flat iron bending cold or hot,drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat,one under coat and one finishing aluminium coat of paint complete all as specified and directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
S&F in renewal of 80 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and bolts/washers complete all as specified and directed.
S&F in renewal of 50 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and bolts/washers complete all as specified and directed.
S&F in renewal of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and bolts/washers complete all as specified and directed .
S&F in renewal of 25 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and bolts/washers complete all as specified and directed.
S & F in renewal of gate light 20W LED post top lantern with transparent diffuser etc including cable connections complete all as specified and as directed
S & F in renewal of 9W decorative LED extruded aluminium bollard light with integrated driver etc including cable connections complete all as specified and as directed
M&L for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth strip 25 x 4 mm by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as specified and directed.
M & L for aluminium strip 25 x 3 .15 mm with base insulators and screws etc fixed on wall/ floor for extension of earthing lead complete all as specified and directed.
S&F VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed
S&F MCB distribution board SPN 240 Volt 12 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed
S&F MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed
S&F MCB distribution board SPN 240 Volt 4 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
S&F MCB single pole 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F Isolator DP 63 Amps rating complete all as specified and directed
S&F Isolator DP 40 Amps rating complete all as specified and directed.
S&F MCB TPN 63 Amps rating 415 volts complete all as specified and directed.
S&F Power contactor 4 pole 63 Amps rating with entry terminals complete all as specified and directed.
Dismantling existing unserviceable feeder pillar box including disconnection from different sites complete all as specified and directed
Fabrication, supply, installation, testing and commissioning in renewal of outdoor type feeder pillar box floor mounted made out from 3.15 mm thick MS sheet ( CPRI type tested) with canopy type roof, over all size 0.75 x 0.60 x 0.30 m front operated, two part hinged doors with locking arrangement comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two parts front and rear shutter with heat strinkable PVC sleeving having RYB-B colour code drilling holes for connection of incoming and outgoing cable, complete powder coated painting, testing and installation on PCC/brick foundation, connection of cable with suitable aluminium lugs complete all as specified and directed. ( Note :-MCCB will be measured and paid separately.)
Fabrication, supply, installation, testing and commissioning in renewal of out door type LT Feeder pillar box size 0.90 m x 0.75 m x 0.45 m in depth made out of 3.15mm thick CRCA sheet ( CPRI type tested) and MS structural section of 50 x50 x 6 mm comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter, hinged front and rear panels and locking arrangement, bottom plate provided with the requires numbers of cable entries / opening including cable glands and cable lugs with heat strinkable PVC sleeving having RYB-B colour code , powder coated painting complete embedded in PCC 1:3:6 type C-2 ( using 40 mm graded stone aggregate ) n. exc. 0.45 cum and provision of following accessories complete all as specified and as directed ( Note :-MCCB will be measured and paid separately.)
(a) BUSBAR. Bus bar chamber with electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators 4 strip of suitable length for current rating 400 amps with neutral 200Amp (b) INCOMING MCCB 4 pole, 250 amps, breaking cap 36 KA , 415V, 50 Hz AC with spreader link on both side -01 No (c) OUTGOING (i) MCCB 4 pole, 63 amps, breaking cap 16 KA , 415V, 50 Hz AC with spreader link on both side -04 Nos (ii) MCCB 4 pole , 100 amps, breaking cap 16 KA , 415V, 50 Hz AC with spreader link on both side -02 Nos (iii) Indication LED light (R,Y,B) = 03 Nos (iv) Multifunction meter Accuracy Class 1.0 to measure the following parameters such as V, A, F, PF, kW, kVA ( Make : L&T Cat No : WL440511OOOO ) - 01 No
Fabrication, supply, installation, testing and commissioning of outdoor type LT feeder pillar box with front and rear opening doors with electrolysis Aluminium bus bars of 1 ½ times of the incoming capacity with provision of extension, dust and vermin proof, cubical, cable alloy for all the feeders, panel fabricated out of 3.15 mm thick CRCA sheet duly pre-treated and powder coated, factory fabricated panel and consisting of the following complete all as specified and directed.
S & F in renewal MCCB 630 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed
S & F in renewal MCCB 400 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed
S & F in renewal MCCB 250 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed
S & F in renewal MCCB 200 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed
S & F in renewal MCCB 160 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed
S & F in renewal MCCB 100 Amps , 3 pole, 415 volts , 50 Hz , 16 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed.
S & F in renewal MCCB 63 Amps , 3 pole, 415 volts , 50 Hz , 16 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed
S & F MCCB 200 Amps, 4 pole, 415 volts, 50 Hz 36 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB complete all as specified and directed
M&L straight through joints( epoxy) for LT underground cable including joint kits suitable for aluminium conductor cable 3.5 core 6 sqmm to 120 sqmm complete all as specified and directed
M&L outdoor LT END Termination Heat Shrink Kits for LT underground cable suitable for aluminium conductor cable of size 6 sqmm to 120 Sqmm (3.5/4C) complete all as specified and directed
S&F Busbar chamber in sheet metal enclosure 100 Amp, 8 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed.
S&F Busbar chamber in sheet metal enclosure 200 Amp, 8 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed.
M & L for preparation of old painted steel or iron surfaces of LT FPB of various size by scrapping with steel wire brush /scrapper emery paper etc and applying one coat of synthetic enameled siemens grey/exising colour( painting shall be done by spray machine) including welding the LT FPB door matching with the LT FPB complete all as specified and as directed.
Disconnection and dismantling of existing serviceable under ground cable of size 6 Sqmm to 120 Sqmm 2/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed.
S B ENTERPRISES
M/S SRI JAGDAMBE TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .