Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 LAccepted-Finance 13 1 BABA DEEP SINGH NAGAR JALANDHAR PUNJAB 144012 | 144012 | ₹1.8 L | 1 | Accepted-Finance L1 |
| 2 | 2₹2.0 LRejected-Finance | ₹2.0 L | 2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | polestarengineers L1 | S S ELECTROENGINEERS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.01 | Supply of 11KV Vacuum bottles for Schneider Breakers of 11KV, Vacuum Circuit Breaker tested as per IEC60056 High-voltage alternating-current circuit-breakers.2. IEC 62271: Electromagnetic compatibility. 3. IS. 9920 High Voltage Switches, 4. IEC 60265-1: High Voltage Switches 5. IEC 60694 High Voltage Switchgear, 6. The ANSI/IEEE standard is C37.09-1999. For dielectric integrity and 7. ANSI N43.3-1993 Power-frequency withstand voltage tests 67The work shall be carried out as per the satisfaction of the Engineer in charge . | 3 | Nos | 1,50,000 ₹1.5 L | 1,07,913 ₹1.1 L |
| 1.02 | Supply of Cycloaliphatic Epoxy Resins Cast Enormous Schneider 11kv, HV Epoxy Insulator of 11KV. with System Voltage: 12KV, Highest system Voltage: 12/28/75KV, Insulation Level: F Class, Short Time Current Rating: 3 second with Internal Threading Inserts terminal it shall be Type tested at NABL accredited Laboratories, Complies with IEC 60137 and IS:2099 (1986), Tested for 100% Leakage proof under pressure, Cast under vacuum, with terminals nut, it shall be as per IS:1897 (2008), with brown colour epoxy insulation free from blisters, burns and other defects as per Indian Standard IS:2099 (1986). The insulator Bushings for alternating voltages above 1000 Volts (ETD 6: Electrical Insulators and Accessories) shall be of 11kv grade for alternating voltage.The work shall be carried out as per the satisfaction of Engineer in charge . | 3 | Nos | 15,000 ₹15,000 | 38,943 ₹38,943 |
| 1.03 | Installation and fixing of 11KV Vacuum Bottles for Schneider Breakers of 11KV, Vacuum Circuit Breaker and 11KV Vacuum bottles and Cycloaliphatic Epoxy Resins Cast Enormous Schneider 11kv, HV Epoxy Insulator of KV, with System Voltage: 12KV in Vacuum Circuit.The work shall be carried out as per the satisfaction of Engineer in charge . | 1 | Job | 5,000 ₹5,000 | 26,500 ₹26,500 |
| 1.04 | Pre-commissioning Test for 11kv. VCB 11Kv/cable before Energisation as per Indian Standard IS 13118 (1991)/IS:3427(1997), Specification for high-voltage alternating current... circuit breakers as per IS/IEC 62271-1 (2007)-High voltage alternating current circuit breakers, IEEE: 37010-IEEE Application Guide for AC high voltage circuit breakers & IEEE 37013-AC high voltage switch gears & generator circuit breaker with Microprocessor High Voltage tester with different voltage 1000V, 2500V, 5000V & 10000 Volts. Testing of cable resistance (IR Value, Open circuit, Continuity Check Test, Phase to Phase, Phase to Earth, Phase to Armoured etc.The work shall be carried out as per the satisfaction of Engineer in charge . | 1 | Job | 10,000 ₹10,000 | 13,500 ₹13,500 |
| 1.05 | Manpower Charges for complete job | 1 | Job | 1,000 ₹1,000 | 10,000 ₹10,000 |
Tender Value
₹2.0 L
EMD Value
₹3,979
Closing Date
13 Mar 2026, 1:00 pmClosed
REGISTRAR, IIT ROPAR
M. VISVESVARAYA BLOCK, REGISTRAR, IIT ROPAR
Tender for SITC of 11 KV Vacuum Bottle, Cycloaliphatic Epoxy Resins HV insulator for 11 KV VCB installed for 5/6.25 MVA Power Transformer 66/11 KV Grid at IIT Ropar
2026_IITRP_901421_1
IITRPR/ENM/T/26/89
Open Tender
Electrical Works
IIT ROPAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹3,979
20 Apr 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
13 Mar 2026
6 Mar 2026
6 Mar 2026 - 13 Mar 2026
Supply of 11KV Vacuum bottles for Schneider Breakers of 11KV, Vacuum Circuit Breaker tested as per IEC60056 High-voltage alternating-current circuit-breakers.2. IEC 62271: Electromagnetic compatibility. 3. IS. 9920 High Voltage Switches, 4. IEC 60265-1: High Voltage Switches 5. IEC 60694 High Voltage Switchgear, 6. The ANSI/IEEE standard is C37.09-1999. For dielectric integrity and 7. ANSI N43.3-1993 Power-frequency withstand voltage tests 67The work shall be carried out as per the satisfaction of the Engineer in charge .
Supply of Cycloaliphatic Epoxy Resins Cast Enormous Schneider 11kv, HV Epoxy Insulator of 11KV. with System Voltage: 12KV, Highest system Voltage: 12/28/75KV, Insulation Level: F Class, Short Time Current Rating: 3 second with Internal Threading Inserts terminal it shall be Type tested at NABL accredited Laboratories, Complies with IEC 60137 and IS:2099 (1986), Tested for 100% Leakage proof under pressure, Cast under vacuum, with terminals nut, it shall be as per IS:1897 (2008), with brown colour epoxy insulation free from blisters, burns and other defects as per Indian Standard IS:2099 (1986). The insulator Bushings for alternating voltages above 1000 Volts (ETD 6: Electrical Insulators and Accessories) shall be of 11kv grade for alternating voltage.The work shall be carried out as per the satisfaction of Engineer in charge .
Installation and fixing of 11KV Vacuum Bottles for Schneider Breakers of 11KV, Vacuum Circuit Breaker and 11KV Vacuum bottles and Cycloaliphatic Epoxy Resins Cast Enormous Schneider 11kv, HV Epoxy Insulator of KV, with System Voltage: 12KV in Vacuum Circuit.The work shall be carried out as per the satisfaction of Engineer in charge .
Pre-commissioning Test for 11kv. VCB 11Kv/cable before Energisation as per Indian Standard IS 13118 (1991)/IS:3427(1997), Specification for high-voltage alternating current... circuit breakers as per IS/IEC 62271-1 (2007)-High voltage alternating current circuit breakers, IEEE: 37010-IEEE Application Guide for AC high voltage circuit breakers & IEEE 37013-AC high voltage switch gears & generator circuit breaker with Microprocessor High Voltage tester with different voltage 1000V, 2500V, 5000V & 10000 Volts. Testing of cable resistance (IR Value, Open circuit, Continuity Check Test, Phase to Phase, Phase to Earth, Phase to Armoured etc.The work shall be carried out as per the satisfaction of Engineer in charge .
Manpower Charges for complete job
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_947468.pdf
techsummary_947468.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tender.pdf
Tender Documents • 0.26 MB
BOQ_947468.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid