Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹34.2 L+₹1.9 L (5.75%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-Finance Being not Lowest | |
| 3 | L3₹34.2 L+₹1.9 L (5.83%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Being not Lowest | |
| 4 | L4₹37.0 L+₹4.7 L (14.4%)Rejected-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Being not Lowest | |
| 5 | L5₹37.5 L+₹5.2 L (16.1%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-Finance Being not Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
CA NO GE/C-31/2021-22PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2021_MES_460508_1
GE/C-31/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
8 documents required · 8 mandatory
₹500
GE (Central) Delhi Cantt-10
₹98,000
Yes
14 Sept 2021
16 Jul 2021
19 Aug 2021
16 Jul 2021
12 Aug 2021
31 Jul 2021
16 Jul 2021 - 31 Jul 2021
60 days
Amount
S & F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all aspecified and directed by Engineer-in-Charge
S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all aspecified and directed by Engineer-in-Charge
M & L for painting new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth,not otherwise described with two coats of synthetic enamel paint over a coat of red oxide complete all aspecified and directed by Engineer-in-Charge
M& L for non skid coloured rectified ceramic tiles 400x400x7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed for laying floor in CM 1:6 including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engineer in Charge, approved by GE.
S&F in repairs vitreous China coloured European type WC with "P" or "S" trap for 100 mm bore , including connection to drain and to flushing cistern with pipe 32mm dia PVC pipe and fixing bolts complete incl seat cover and PVC low level flushing cistern dual type10 ltrs capacity complete all aspecified and directed by Engineer-in-Charge
Excavation in trenches (soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out complete all aspecified and directed by Engineer-in-Charge
M & L Cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) in foundations, filling and mass concrete as in sub base complete all aspecified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all aspecified and directed by Engineer-in-Charge .
M & L for removing excavated material exc. 250m but not exceeding 500m and depositing where complete all aspecified and directed by Engineer-in-Charge
M & L for brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all aspecified and directed by Engineer-in-Charge
M&L for rendering 15 mm thick cement plaster in CM 1:4 on new surfaces of concrete or brick surfaces of walls or chajjas or pillars finished even and smooth without using extra cement including scaffolding and necessary formwork if required complete all aspecified and directed by Engineer-in-Charge
M & L for preparation of new plastered surface of wall and applying two coat of cement based paint over one coat of primer from the same manufacturer including scaffolding if required complete all aspecified and directed by Engineer-in-Charge
S&F Powder Coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including aluminium alloy Powder coated standard 10mm section window grill as per approved sample and as per IS specifications joining cleat for fixing etc.complete all aspecified and directed by Engineer-in-Charge
M&L anodised aluminium window/door and ventilator shutters, sliding or side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) including 4mm thick glass panes or stainless steel wire mesh complete all aspecified and directed by Engineer-in-Charge Note : The rate quoted by the contractor is inclusive of all fixture/fittings/glass/wire mesh etc.
S&F for 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all aspecified and directed by Engineer-in-Charge
S&F in Soft closing ball bearing telescopic channel of size 22 inch long fixed with screws in cupboards incl all fittings complete all as spd and directed by Engr in charge.Note : Runner/ Channel should be SS 304 grade and load capacity should not be less than 45 kgs
“S&F Modular Cabinet Kitchen accessories of Stainless Steel grade-304,6mm size rod thickness including :- (i) Perforated Cutlery basket, (ii) Grain trolley, (iii) Thali basket, (iv) Cup & saucer basket, (v) Glass basket, (vi) Plate basket, (vii) Premium magic corner (viii) Oil Pull out Tray ( Triple basket layer) of size as per site requirement all spd and directed by Engr in charge
S&F 40mm dia and 75mm long, extrruded fancy type SS handle for kitchen cup boards shutters, cabinets, crocery shelf drawers fixed with nuts, screw and washer of mild steel bright finished, complete all aspecified and directed by Engineer-in-Charge .
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all aspecified and directed by Engineer-in-Charge
Dismantling boarding any description (board/plywood) fixed in any position with screw, complete all aspecified and directed by Engineer-in-Charge
S&F 18/19mm thick Block boards, grade 1 quality, e x t e r i o r grade, commercial type, fixed with screws to timber frame-workfor cabinet boxes, crockery almirahs, books shelves etc with self and shutter full size fitted under/above the kitchen cooking platform and other rooms directed incl Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions provn of fixing arrangement etc,complete all aspecified and directed by Engineer-in-Charge
S&F 75 mm long L Bihari concealed type hydrauilc hinges incl stainless screw complete all as specified.
M&l false ceiling using plain galvanised steel ceiling system consisting 600mm x 600mm lay in tiles of pre coated galvanised steel sheets in 0.5mm thick in white or coloured to be laid of grid system with 15mm wide T-section flanged having rotary stitching on the main runner and 1200mm cross tees. the main runner spaced 1200mm centre flush fitting 1200mm long cross tees to be interlocked between runner at 1600mm centre to foRm 1200mm x 600mm module. Perimeter trim to be wall angle of size 3000 x 19 x 19mm secured to wall @450mm c/c and inclu. suspension system as per manufacturer's instructions, complete all as specified and directed by Engineer in charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all aspecified and directed by Engineer-in-Charge
M & L for reinforced cement concrete nominal mix (1:1.5:3) using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all aspecified and directed by Engineer-in-Charge
Supply and fix TMT bars,6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all aspecified and directed by Engineer-in-Charge
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all aspecified and directed by Engineer-in-Charge
M&L for coloured glazed ceramic tiles 300x600 x 7 to 8mm thick as in vertical surfaces of wall as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 including demolition of existing old tiles complete all aspecified and directed by Engineer-in-Charge
M & L 600 mm x 600 mm for vitrified tiles 10 mm thick (square) polished in floors / dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm screed bed in CM 1:6 including demolition of existing old tiles complete all aspecified and directed by Engineer-in-Charge
M & L for 16-18 mm thick Black Granite stone work (table rubbed and polished) over and including15mm thick Screed bed or bedding layer in CM 1:4, as in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,front and side of slab moulded and polished including dismantling the existing stone slab with screed/ backing and removal of debries out side the MOD Land complete all as specified and as directed by the Engineer-in-Charge.Note- The cost of making hole for Gas pipe in cooking plateform is included in unit cost of item and nothing extra shall be paid on this account
Taking up or down 15 mm dia GI tubing and connections complete all aspecified and directed by Engineer-in-Charge
Taking up or down 20 mm dia GI tubing and connections including cleaning for re-fixing, complete all aspecified and directed by Engineer-in-Charge
S&F15mm dia GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors, pipes should be painted with bituminous paint of approved quality complete all aspecified and directed by Engineer-in-Charge
S&F 20mm dia GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors etccomplete all aspecified and directed by Engineer-in-Charge
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed incl Dismantling of PVC water tanks of exc 500 litres and n.exc 1000 litres capacity of any condition or type incl complete all aspecified and directed by Engineer-in-Charge
S&F sinks made of stainless steel 1mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all aspecified and directed by Engineer-in-Charge
Dismantling of brick tiles or terracing tiles single layer on roof and removing the rubbish outside complex (MOD land),incl removal of vagitation if any complete all aspecified and directed by Engineer-in-Charge
Demolition of mud in roof, any thickness, including mud plastering and mud phuska under brick tiles at any situation and height, complete all aspecified and directed by Engineer-in-Charge
M&L for PCC 1:2:4 (using 20mm aggregate) type B-1 as in levelling course using WPC finished even and smooth without using extra cement (WPC shall be measured and paid seperately) complete all aspecified and directed by Engineer-in-Charge
M&L for APP based polymeric membrane mineral slate finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints complete all aspecified and directed by Engineer-in-Charge
M & L Cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops etc including weathering slightly rounded or chamfered edges, finished even and smooth without using extra cement including form work , complete all aspecified and directed by Engineer-in-Charge
M & L for supreme quality Heat Resistant Terrace Tiles(Swastik) of size 300x300x9.mm thick over and including 15mm thick screed in CM 1:4 complete all aspecified and directed by Engineer-in-Charge
M&L for Surface dressing n exc 15 cm deep and site clearance complete all aspecified and directed by Engineer-in-Charge
M & L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all aspecified and directed by Engineer-in-Charge
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry laid over 15mm thick screed bed in cm 1:6 as in floors with no pigment complete all aspecified and directed by Engineer-in-Charge
M&L for 15mm thick internal rendering in cement omrtar 1:6 on fair face of brick walls/concrete surfaces & finished even and smooth without using extra cement including two coats of oil bound distermber over a coat of primer with 2 to 3 mm thick birla wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L Hardcore of broken stone of gauge n. exc 63 mm deposited, spread and levelled in layers not exc 150 mm thick watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in ssub floor complete all as specified and directed by Engineer-in-Charge.
M7L Kota stone slab 16-18mm thick with uniform texture in floor (size 580mm x 580mm ) with laid over and including 15mm thick screed in CM 1:6 and jointed with grey cement slury mixed with pigment to match the shade of the slab including rubbeing and polishing complete all as specified and directed by Engineer-in-Charge.
S&F fiber glass Rainforced Plastic (FRP) Door Frames of cross section 90x45mm having single rebate of 32x5mm to receive shutter of 30mm thick. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete all aspecified and directed by Engineer-in-Charge
S&F 30mm thick Glass Fibre Rainforced Plastic (FRP) panelled door shutter of requied colour and approved brand and mainfacture, made with fire-retardantgrade unsaturated polyester resin moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden fram and suitable blocks of seasoned wood inside at required places for fixing of fitting, cast monolithically with 5 mm thick FPR laminate for panels conforming to IS: 14856, including providing 3 Nos MS butt hinges 100mm, 2 Nos aluminium tower bolt 200 mm 2 Nos aluminiumbow handle 150mm to each door suhtter and fixing to frmes complete all as specified and directed by engineer-in-Charge
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including PVC conduit not less than 20mm dia , including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/fan point controlled by one way switch
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 52 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M&L switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge .
M&L socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz including louvers, provision of making hole for fixing of fan and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge
Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz including louvers and provision of making of hole for fixing of Exhaust fan and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all aspecified and directed by Engineer-in-Charge
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all aspecified and directed by Engineer-in-Charge
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all aspecified and directed by Engineer-in-Charge
S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure complete all as specified of capacity 25 ltr having heating element 1.5 KW and not less than 5 star rating complete all aspecified and directed by Engineer-in-Charge .
Supply and fix Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls complete all aspecified and directed by Engineer-in-Charge . Note: Three runs of 4 sqmm cable shall be measured as one RM.
Supply and fix Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls complete all aspecified and directed by Engineer-in-Charge Note: Three runs of 6 sqmm cable shall be measured as one RM.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixedcomplete all aspecified and directed by Engineer-in-Charge
M&L sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
S&F tubes, 'medium grade', galvanised, with all fitting; laid in trenches, fixing on wall complete of bore 15mm dia complete all aspecified and directed by Engineer-in-Charge
S&F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of cap 15mm dia complete all aspecified and directed by Engineer-in-Charge
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all aspecified and directed by Engineer-in-Charge
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Note :- Total amount of Sch of credit is Rs. 3570.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
GIAN ENGINEERS
M/S ANIL KUMAR
LAMBA ENTERPRISES
imran construction company
Mahesh Enterprises
JAIPAL and BROS
ergon enterprises
jay maa engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .