Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹6.9 L+₹35,899 (5.51%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹7.0 L+₹46,000 (7.06%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹7.0 L+₹51,779 (7.95%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹7.1 L+₹57,599 (8.84%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
28 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
ADDITION/ALTERATION TO BUILDING NO P-04 OF HQ CIF (K) AT SHALATENG GARRISON UNDER AGE (I) CIF (K)
2021_MES_491333_1
CA NO AGE (I) CIF (K) - 62/2021-22
Open Tender
Civil Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
AGE (I) CIF (K)
₹16,000
Yes
1 Jan 2022
30 Nov 2021
30 Dec 2021
30 Nov 2021
28 Dec 2021
14 Dec 2021
60 days
Amount
B/R Works: Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, complete all as specified and directed by the Engineer-in-Charge
Pre- painted prefabricated Mangalore pattern steel sheet 0.50mm thick (Red Colour) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by the Engineer-in-Charge.
Prepainted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof, fixed with self tapping screws, complete all as specified as directed by the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by the Engineer-in-Charge.
Mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including mbeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
Mild steel, plain, black sheet, 1mm thick for eaves board fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed by Engineer-in-Charge.
Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and as directed by the Engineer-in-Charge.
Dismantling timber scantling 40 Sq cm and over in section in any position, framed work, complete all as specified and as directed by the Engineer-in-Charge.
2nd class soft wood (Kail) as in scantling, clean sawn timber, fixed in framed work, complete all as specified and as directed by the Engineer-in-Charge.
Khatamband ceiling fixed on including 8/9 mm ply board fixed to wooden frame including complete polishing upto mirror finish, complete all as specified as directed by the Engineer-in-Charge.
8mm thick laminated wooden wall panelling interlocking type fixed with nails to timber frame work, complete all as specified and as directed by the Engineer-in-Charge. Note : The pattern and colour of panelling shall be approved by AGE (I) and contractor shall not have any claim whatsoever on this account.
Plain fillets. square, rectangular or triangular in section, made of 2nd class soft wood (Kail), wrought, secured with nails or brads, sectional area exceeding 13 sqcm but not exceeding 25 sqcm, complete all as specified and as directed by the Engineer-in-Charge.
10 to 12 mm thick laminated interlocking type wooden flooring suitable adhesive and rubber packing over synthetic moisture resistant form on exsisting PCC floor , complete all as specified as directed by the Engineer-in-Charge.
Demolition of cement concrete un reinforced in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including disposal of unserviceable materials,debris and rubbish to a distance not exceeding 100 metre, complete all as specified and as directed by the Engineer-in-Charge.
Plain cement concrete, 1:2:4, type B-0 using 12.5mm graded crushed stone aggregate, 25mm thick, surface finished fair to receive top layer of flooring, complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and not exceeding 4.00 sqmeach including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost), complete all as specified and as directed by the Engineer-in-Charge.
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and asdirected by Engineer-in-Charge.
Anodised aluminium door shutters, powder coated of any colour aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, anodised aluminum snap beading screws etc. frame will be fixed to wall , complete all as specified and directed by the Engineer-in-Charge.
Anodised aluminium window and ventilator shutters, powder coated of any colour sliding/ hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 nos.) suitable handle (1 no.), complete all as specified and directed by the Engineer-in-Charge.
4 mm thick tinted sheet glass, glazing with in alm frames including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings as required, complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles including removing of rubish, complete all as specified and as directed by the Engineer-in-Charge.
Brick work with sub class `B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6, complete all as specified and directed by the Engineer-in-Charge
Plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in lintels upto 1.50 metres clear span, steps, seismic and other similar bands, coping, bed plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating, and use of form work (straight or curved), complete all as specified and as directed by the Engineer-in-Charge.
Taking down plastering in cement lime or cement mortor on brick or stone work etc. including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed by the Engineer-in-Charge.
Rendering 15mm thick on brick work or concrete surface in cement mortar 1:4, finishing surfaces even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge.
Preparing new plastered or unplastered surfaces of walls for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and as directed by the Engineer-in-Charge.
Preparing old plastered or unplastered surfaces of walls for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and as directed by the Engineer-in-Charge.
Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6, finishing surfaces even and smooth without using extra cement, complete all as specified and directed by the Engineer-in-Charge.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over Chalk whiting, on plastered surfaces, preparatory to distempering ,complete all as specified and as directed by Engineer -in -Charge.
Preparation of old decorated plastered or unplastered surfaces of wall including cleaning by brooming down or with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots etc. and applying two coats of oil bound distemper on wall, complete all as specified and as directed by Engineer -in -Charge.
E/M Works: Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches,ceiling rose ,pendents ,regulators,socket,lamp holders brackets,bulk head fitting, etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and also making good distrubed surfaces of wall,floors etc, complete all as specified and directed by the Engineer-in-Charge.
Point wiring with 1.5 sqmm copper conductor (Multistranded) PVC insulated and unsheatheted FRLS electric cable 1100 volts grade and including PVC casing caping/conduit pipe of suitable size with all fittings accessories and including PVC insulated electric cable 1100 volts, 1.5 sqmm (multi stranded) copper conductor single core (Green colour) cable as continious earth wire connected to common earth dolly including sunk sheet terminal box made out of 1.6 mm thick MS sheet concealed on wall or on surface as per site requirement and making good distrubed surface of wall ,covered with 3 mm thick plastic laminated for mounting of switches, socket, fan regulators etc., complete all as specified and directed by the Engineer-in-Charge for the following:-
One light /fan/bell point controlled by one No, one way 5 Amps switch. complete all as specified and as directed by the Engineer-in-Charge.
One 3/5 pin socket outlet, 5 Amp, independent, controlled by one No. one way switch on independent board, complete all as specified and as directed by the Engineer-in-Charge.
One 3/5 pin socket outlet, 5 Amp controlled by one No, one way switch on same board, complete all as specified and as directed by Engineer-in-Charge.
All as per serial item No 32 here-in-before ,but for one socket out let 15 Amp on the independent board with 2.5 sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts (ISI MARKED) including PVC insulated and unsheathed electric cable 1100 volts, 2.5 sqmm copper stranded conductor as continious earth wire connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure factory made (double door) shutter type for MCB DB SPN, 240 Volts, 8 ways with 200 Amps rated bus bar, neutral link, earth bar, complete all as specified and as directed by the Engineer-in-Charge.
MCB SPN, 35-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
MCB SP, 5 -32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, including taking down old existing, complete all as specified and as directed by the Engineer-in-Charge.
Modular switch 1 way 6 amp 1 module, complete all as specified and as directed by the Engineer-in-Charge.
Modular socket 6 Amp -2/3 pin combined 2 moudle, complete all as specified and as directed by the Engineer-in-Charge.
Modular socket 6/16 Amp -2/3 pin combined 2 moudle, complete all as specified and as directed by the Engineer-in-Charge.
White cover plate with frame,1 module,complete all as specified and as directed by the Engineer-in-Charge.
White cover plate with frame,2 module, complete all as specified and as directed by the Engineer-in-Charge.
White cover plate with frame,3 module, complete all as specified and as directed by the Engineer-in-Charge.
White cover plate with frame,4 module, complete all as specified and as directed by the Engineer-in-Charge.
White cover plate with frame, 6 module, complete all as specified and as directed by the Engineer-in-Charge.
White cover plate with frame, 8 module, complete all as specified and as directed by the Engineer-in-Charge.
Metal flush box 1/2 module, complete all as specified and as directed by the Engineer-in-Charge.
Metal flush box 3 module, complete all as specified and as directed by the Engineer-in-Charge.
Metal flush box 4 module, complete all as specified and as directed by the Engineer-in-Charge.
Metal flush box 6 module, complete all as specified and as directed by the Engineer-in-Charge.
Ceiling rose surface type, 65 mm x 50 mm three terminals/PVC/polycarbonate, isolated body fixed on PVC block,complete all as specified and as directed by the Engineer-in-Charge.
Modular Electronic fan regulator 120 Watt, 2 module, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by the Engineer-in-Charge. Make: Havells Cat part No LHEXBLP7PN1W020 or equivalent in Bajaj/Crompton Greaves /Phillips
Edgepro round slim-fit low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology.An ideal solution where ceiling voids are limited but high lumen output 12 Watt LED and making of electrical connection with and including three core flexible copper conductor cable of suitable size, including taking down existing old unserviceable, complete all as specified and as directed by the Engineer-in-Charge. Make :- Havells Cat No- EDGEPRORDDLR12WLED857S or equivalent in Bajaj/Crompton Greaves/Phillips
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in and including casing caping/PVC conduit ISI marked of suitable size and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed by the Engineer- in-Charge. Note :- 2 +1 run of 6Sqmm cable including casing caping/PVC conduit of suitable size shall be measured as one running metre.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire,4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009), complete all as specified and directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Wall mounted fan 230 V, 1200mm sweep, electric driven single phase 240 Volt, 50 Hz, complete all as specified and directed by Engineer-in-Charge. Make:- Havells/Usha/Bajaj/CG
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc., including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, complete all as specified and as directed by the Engineer-in-Charge.
Note :- An amount of Rs. 19,471.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
JK BUILDERS AND ENGINEERS
M/S SHEIKH FEROOZ AHMAD
SOFI CONSTRUCTIONS
M/S RAFIQ AHMAD SOFI AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .