Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹52.9 L+₹4.1 L (8.35%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | L3₹74.6 L+₹25.8 L (52.8%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L3 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
18 Sept 2021, 6:00 pmClosed
GE Chennai
Fort Saint George, Chennai
SPECIAL REPAIR REPLACEMENT OF LT PANEL FEEDER PILLAR BOX LT UG CABLE TO PGEP AND TA FLOOD PUMP HOUSE AND CERTAIN OTHER SANCTIONED WORKS UNDER GE CHENNAI
2021_MES_469771_1
8546/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Fort Saint George
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Chennai
₹92,000
Yes
20 Nov 2021
21 Aug 2021
25 Sept 2021
21 Aug 2021
18 Sept 2021
4 Sept 2021
Amount
BOQ UPLOADED ON 28 AUG 2021
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for taking out/ laying cables, pipes etc. and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, laying/ spreading in trenches clean dry sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and directed. Note: Punned thickness only will be considered or payment.
Supply and laying burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and directed.
M&L for providing PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3½ core including taking out old cable complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3½ core including taking out old cable complete all as specified and directed.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sqmm 3½ core including taking out old cable and carefully stacking the same for re-use complete all as specified and directed.
Supply and laying GI tube light grade 50mm bore with all fittings laid in trenches/ floor/ along wall for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 80mm bore with all fittings laid in trenches/ floor/ along wall for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 80mm bore with all fittings laid in trenches/ floor/ along wall for cable protection and for drawing earth strip/ earth lead wire etc., complete all as specified and directed.
Supply, fix, connecting and testing MCCB 125 Amp, three pole, 415 volts breaking capacity, 16kA with adjustable thermal & magnetic setting including taking out old unserviceable MCCB complete all as specified and directed.
M&L cable jointing kit for 1100 volts grade cable for straight through heat shrink type joints complete with jointing material and accessories suitable for 95 sqmm 3½ core XLPE armoured aluminium conductor cable complete all as specified and directed.
M&L for horizontal directional drilling (HDD) with trenchless technology using ultra sound technique and necessary machines including pilot drilling, pre-reaming, reaming suitable for 150mm/ 160mm dia HDPE pipe including supply and laying HDPE pipe of pressure not less than 4 kg/ sqcm, grade PN-6 PE-80 conforming to IS-4984 with fittings; complete drilling carried out under road pavement, hardstanding etc. at a level upto 2.0m below existing ground level in any type of soil strata complete all as specified and directed.
M&L air termination, single pointed aluminium rod 12mm dia and 300mm long with suitable nuts, bolts, screws, washers etc. including taking down existing rod complete all as specified and directed.
M&L shackle type insulator of size 75mm height and 90mm dia of porcelain, vitreous, white, brown or green including 31mm x 3mm galvanised mild steel straps with 12mm dia bolt including washers and nuts including taking down existing insulator complete all as specified and directed.
M&L bakelite insulator sheet of size 100mm x 100mm x 12mm thick for fixing air termination including necessary nuts, bolts and washers fixed in replacement complete all as specified and directed.
S&F galvanized steel water tubing 40mm bore medium grade for fixing of air termination single pointed aluminium rod with necessary nuts, bolts and washers fixed in replacement complete all as specified and directed.
S&F GI strip of size 32mm x 6mm complete with necessary nuts, bolts and washers buried in ground fixed in replacement complete all as specified and directed.
S&F aluminium strip of size 25mm x 3.15mm complete with saddles fixing screws etc. for roof conductor and down conductor above ground level fixed in replacement complete all as specified and directed.
M&L test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm; drilled and screwed including 3 Nos. 8mm dia 25mm long hexagon head screw fixed in replacement complete all as specified and directed.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 250 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. (e) Change over 250 Amp, 4 pole -01 No. OUTGOING: (a) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCCB 63 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 125 Amp, 25 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 63 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCB 32 Amp SPN- 02 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 400 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. (e) Change over 250 Amp, 4 pole -01 No. OUTGOING: (a) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCCB 160 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 05 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 400 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 05 No. (b) MCCB 63 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 04 No. (c) MCB 32 Amp SPN- 03 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 250 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 06 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 250 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCCB 63 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 125 Amp, 16 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCCB 63 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 02 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 400 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 100 Amps, 16 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 04 No. (b) MCCB 125 Amps, 16 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 02 No. (c) MCCB 200 Amps, 36 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 02 No. (b) MCCB 250 Amps, 36 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 250 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 63 Amps, 16 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCCB 160 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 250 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. OUTGOING: (a) MCCB 63 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 500 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. (e) Change over 250 Amp, 4 pole front loaded operated-01 No. OUTGOING: (a) MCCB 160 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No. (b) MCCB 200 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No. (c) MCCB 250 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No. (d) MCCB 350 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No. (e) MCCB 400 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
INCOMING: (a) Electrolytic grade high conductivity solid 4 Nos aluminium bus bars, rated 800 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3 (c) Ammeter and voltmeter digital multi meter -01 No. (d) MCCB 250 Amp, 36 KA breaking capacity, 4 pole with thermal magnetic setting- 01 No. (e) Change over 250 Amp, 4 pole front loaded operated- 01 No. OUTGOING: (a) MCCB 63 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No. (b) MCCB 100 Amps, 25 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 03 No.
Supply, install, testing and commissioning of cubical housing cabinet type LT feeder pillar outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA (Cold Rolled Cold Annealed) MS Sheet, Powder coated, CPRI approved having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers including necessary foundation work and also complete wiring as per manufacturer’s instructions fixed in replacement of existing panel and fitted with and including the following:-
(a) Electrolytic grade high conductivity TPN solid copper bus bars, rated 400 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings duly colour coded at required intervals for identification- 01 Set. (b) LED Indicating lamps for main supply indicating ‘R', ‘Y' & ‘B'- 01 Set of 3. (c) MCCB 250 Amps, 50 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 01 No. (Incoming) (d) MCCB 125 Amps, 35 KA breaking capacity, 4 pole with fixed thermal & fixed magnetic setting - 04 No. (Outgoing) (e) MCB 32 Amp TPN ‘B’ curve 16KA breaking capacity- 05 No. (f) MCB 16 Amp TPN ‘B’ curve 10KA breaking capacity- 02 No.
Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6.3mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, earth plate connected to galvanized iron earth strip of size 32mm x 6mm as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR part I (2009) connected to earth test point/ main switch/ DB/ Panel board all as specified or indicated including testing on completion with and including 40mm bore light grade GI protection pipe 7.5 meter long for earth strip including PCC (1:3:6) type C1 pit with 40mm thick precast RCC (1:2:4) type B-1 cover reinforced with 12mm dia MS bars @ 150mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia light grade, common salt, charcoal filling in layers as specified, necessary excavation and earth work in any type of soil etc., complete all as specified and as directed. Note: Quoted rate shall be deemed to include cost of GI strip upto 7.50m from test point. Any variation in length shall be length shall be adjusted vide item No. 20.00 of BOQ.
Supply, fix, connecting and testing MCCB 400 Amp, 4 pole, 36 KA breaking capacity with fixed thermal & fixed magnetic setting all as specified and directed.
EVEREST ENGINEERING WORKS
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .