Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC Awarded as first lowest bidder (L1) | |
| 2 | L2₹42.1 L+₹3.9 L (10.1%)Rejected-AOC | L2 | Rejected-AOC Being as second lowest bidder | |
| 3 | L3₹42.8 L+₹4.6 L (12.1%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L3 | Rejected-AOC Being as third lowest bidder | |
| 4 | L4₹43.0 L+₹4.8 L (12.5%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L4 | Rejected-AOC Being as forth lowest bidder | |
| 5 | L5₹44.1 L+₹5.8 L (15.3%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L5 | Rejected-AOC Being as fifth lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
30 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR AND MAINT OF CHILLED CENTRAL PACKAGE SPLIT WINDOW TYPE AC AT HEMRL SUTARWADI UNDER GE RD PASHAN
2022_MES_511034_1
GERD/PSN/TOKEN/57 OF 2021-22
Open Tender
Civil Works
Item Rate
240 days
GERD PASHAN PUNE
As per tender documents
9 documents required · 9 mandatory
₹500
GERD PASHAN PUNE
₹80,000
Yes
9 Jun 2022
28 Feb 2022
2 Apr 2022
1 Mar 2022
30 Mar 2022
16 Mar 2022
1 Mar 2022 - 15 Mar 2022
60 days
Amount
Supply and fix in repairs wornout crankcase heater of compressor Complete all as specified and directed of Make : Accel Type -SMC-2to65, SMC-4to65, SMC-6to65, SMC-8to100, AC-470 or as per existing specifications Complete all as specified and directed.
Supply and fix in repairs shaft seal assembly for vaious models of compressors as per existing specifications Complete all as specified and directed of Make : Accel / Kirloskar
Material and labour in repair for descaling of shell and tube type water cooled condenser of capacity 15 TR to 30 TR with MS shell and intergral copper tubes with and including safety valve with and including cleaning agent including nitrogen flushing / descaling compound and through cleaning with and including descaling nylon brush with and including rod and circulating by descaling pump including repalcement of gasket set, nuts and bolts and leak testing after descaling / cleaning of condenser unit Complete all as specified and directed
Material and labour in repair for descaling of shell and tube type water cooled condenser of capacity 31 TR to 75 TR with and including MS shell and intergral copper tubes with and including safety valve with and including cleaning agent including nitrogen flushing / descaling compound and through cleaning with descaling nylon brush with and including rod and circulating by descaling pump including repalcement of gasket set, nuts and bolts and leak testing after descaling / cleaning of condenser unit Complete all as specified and directed
Material and labour in repair for chipping of insuation and opening of end plate for cleaning and washout of foreign material and scale and deposits of chiller unit Direct Expansion, shell and tube type 15 TR to TR-30 TR capacity with and including cleaning agent including nitrogen flushing and through complete cleaning nylon brush including replacement of gasket set, nuts, bolts and EPDM insulation on both ends, faces matching to existing chillar insulation complete all as specified and directed.
All as per item No 5 here in before but for 31 TR to 75 TR capacity.Complete all as specified and directed
Material and labour in repair for disconnecting electrical connections motor located at the top of cooling tower,keep cables at safe custody for reconnection and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting/dismentaling all nuts, bolts and fixtures from the mounting frame and removing whole assembly including motor and base frame from the top of cooling tower with the help of necessary T and P for servicing of cooling tower suitable for 15 TR to 60 TR capacity comprising of following Complete all as specified and directed :- (i) Cleaning /scrapping of inner and outer surface of FRP basin, repair of damaged portion if any incuding FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts joining all parts of Basin complete. (ii) servicing cooling tower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and make the necessary alignment with motor. (iii) Replacement of bearing if any of suitable capacity if any after necessory work including greasing and replacement of nut bolts and preventing leakage if any by means of suitable adhevies etc Complete all as directed and specified. (iv) Taking out PVC fills blocks, cleaning and refixing as per existing location and channel direction. (v) Servicing of spray header and sprinkler assembly complete. (vi) Repair of water strainer complete.
Supply and fix in repair Suitable bearings for Fan Motor of Cooling Tower of Capacity 15 TR to 60 TR Complete all as specified and directed
Supply and fix in repair Suitable bearings for Fan Motor of Cooling Tower of Capacity 75 TR to 150 TR Complete all as specified and directed
Supply and fix in repair Sprinkler Hub top and bottom portion with PVC Pipe and cap complete set for capacity 15TR to 60TR Complete all as specified and directed
Supply and fix in repair Sprinkler Hub top and bottom portion with PVC Pipe and cap complete set for capacity 61TR to 150 TR Complete all as specified and directed
Supply and fix in repair PVC nozzle and sprinkler pipe Complete all as specified and directed
Supply and fix in repair toggle switch one way 5 Amps including control wiring and plugs if any Complete all as specified and directed
Material and labour in repair for disconnecting electrical connections, refrigerent piping, and water piping, servicing, Repair and Over hauling of AHU for Air handling unit of capacity 3000 cfmto12000 Cfm, sectionalized construction of capacity 7.5 TR to 30 TR, removing dust, dirt, foreign material deposited on cooling coil fins with suitable ditergent, Cleaning / de-carbunising of pre and post air filters of shaft and reinstalled in same position with correct alignment after cleaning /repairing, remove the all rust from shaft by matchinery work, polishing matching to existing and rebalancing of shaft including Servicing and testing of blower drum assembly for proper functioning and balancing, testing, commissioning complete for achieving desired performance including replacement of major defective spare parts as ordered under respective items of Schedule “A” here-in-after as "supply only" (item No. 144 to 148, 153 to 168) including supply and fixing minor parts required as directed to achive noise free operation complete all as specified and directed.
Material and labour in repair for disconnecting electrical connections, refrigerent piping, and water piping, servicing, Repair and Over hauling of AHU for Air handling unit of capacity 12000cfm to13000 Cfm, sectionalized construction of capacity 31 TR to 60 TR, removing dust, dirt, foreign material deposited on cooling coil fins with and including suitable ditergent, cleaning of Water Tray, Cleaning/de-carbunising of pre and post air filters and reinstalled in same position with correct alignment after cleaning /repairing, remove the all rust from shaft by machinery work and rebalancing of shaft including Servicing and testing of blower drum assembly for proper functioning and balancing, Testing, commissioning complete for achieving desired performance including replacement only of major defective spare parts as ordered under respective items of Schedule “A” here-in-after as "supply only" (iten No. 144 to 148, 153 to 168) including supply and fixing of minor spare parts complete.
Material and labour in repair for spray water type dehumidification system of air handling unit complete by Pressurized, cleaning of spray water header with nozzle Complete all as specified and directed including replacement of following unservicible parts :- (a) Replacement of unserviceable Spray water nozzle if any. (b) Replacing Flexible PVC pipe Heavy duty of 20 mm dia complete from water tank to dehumidifier pump. (c) Repairing GI pipe medium grade of 20mm dia with fittings. .
Material and labour in repair for disconnecting electrical and water connection of hot water generator of capacity 10 KW TR to 50 KW TR of 15 TR to 60 TR AC plant and sealing ends carefully, dismentling and taking out complete generator, dismentling terminal heater plate, rods, replacement of gasket set for repair and Reassembling, testing and commisssioning the hot water generator after repair including to and fro transportation from site to workshop all as directed including fixing of unserviceable parts as ordered here in after in respective items of Schedule “A” as "supply only" (Item No. 18 to 21) Iincluding supply and fixing minor required items and testing for 08 hours to achieve desired condition and temperature to the entire satisfaction of Engr-in-charge complete all as specified and directed.
Supply only following defective worn out unserviceale spare parts for hot water generator of capacity 10KW TR to 50KW TR of Make as per existing make availale at site complete to be replaced against item 17 here-in-above all as specified and directed :-. (a) Heater Rod 3KW, suitable for 3 PH, 415V AC supply as per sample.Complete all as specified and directed.
(b) Heater Rod 9KW, suitable for 3 PH, 415V AC supply as per sample.Complete all as specified and directed
(c) Terminal heater plate suitalble for a and b Nos of heater rods including control circuit.Complete all as specified and directed
(d) Thermostate and control switch ON/OFF assembly control auto and manual paramerters.Complete all as specified and directed
Material and labour in repairs for condenser/chiller pumps including dismantling of Pump of following capacity and segregating its parts for repairs and maintenance, replacement only of shaft bearing, impeller key, shaft sleeve, impeller and grinding / polishing, bend removing etc complete including painting by two coats of synthetic enamel paint including preparation of surfaces, reassembling of pump after completion of repair work and testing complete all as per direction and satisfaction of Engineer in charge complete all as specified and directed comprsing following - Notes : (i) Supply only (item No. 24 to 37) of bearing and sleeve, impeller will be measured and paid under relevent item of work. (ii) Any other minor items required to be replaced is dimmed to include in quoted rate. (a) from 3 HP upto & including 7.5 HP.
(b) above 7.5 HP to 15 HP
Supply only following spare parts of pumps sets complete all as specified and directed(To be incorporated under respective items for item no 22 & 23 here-in-before) :- (a) Shaft bearing of 3 HP pumpset as per existing specifications Complete all as specified and directed
(b) Shaft sleeve of 3 HP pumpset
(c) Impeller of 3 HP pumpset
(d) Impeller Keys of 3 HP pumpset
(e) Shaft bearing of 7.5 HP pumpset
(f) Shaft sleeve of 7.5 HP pumpset
(g) Impeller of 7.5 HP pumpset
(h) Impeller Keys of 7.5 HP pumpset
(i) Shaft bearing of pumpset above 7.5 HP to 10 HP
(j) Shaft bearing for above 10 HP to 15 HP pumpset
(k) Shaft sleeve of pumpset above 7.5 HP to 10 HP
(l) Shaft sleeve for above 10 HP to 15 HP pumpset
(m) Mechanical Couplings for Pumpset 3 HP to 5 HP pumpset
(n) Mechanical Couplings for Pumpset 7.5 HP to 15 HP pumpset
Material and labour in repair for disconnecting from main supply, dismantling and taking out carefully squirrel cage induction motor 3 Phase, 415V AC from existing foundation for servicing and necessary repair including replacement of unserviceable parts such as ball bearing as ordered here in after in respective items of Schedule “A” as "supply only" (item No. 46 to 47)including supply and fixing minor required items likes nuts, etc, washers, Carry out Misclanious repairs and, reassembling, testing and commisssioning the motor after repairs for the following capacity. Complete all as specified and directed (a) 1 HP to 2 HP
(b) 3 HP to 5 HP
(c) 7.5 HP to 15 HP
(d ) 16 HP to 40HP
Disconnecting the electrical and mechanical connection of burnt electrical motor from the site / location, transporting to and from to work shop, rewinding of electrical motor/ pump motor by dismantling and removing the burnt cut copper winding wire, cleaning the slots of stator with petrol and brushes, winding polyster based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing and heating the coil and remove air bubbles complete stator / roter after rewinding, reassembling all parts including reinstalling connection to original position and testing on full load Complete all as specified and directed for following capacity of motor as per following :- (a) 1 HPto 2 HP
(b) 3 HP to 7.5 HP
(c) 10 HP to 15 HP
(d ) 16 HP to 40 HP
Supply only Ball bearing for squirral cage induction motor of capacity 1 HP to 20 HP Complete all as specified and directed
Supply only Ball bearing for squirral cage induction motor of capacity 25 HP to 75 HP Complete all as specified and directed
Supply and fix in repairs for thermal expansion valve suitable for 50 TR to 90 TR chilled water Central type AC plant system all as per sample, including brazing at both ends Complete all as specified and directed
All as per item No 48 here-in-before but suitable for central A/C plant 15 TR to 45 TR.Complete all as specified and directed
Material and labour in repair for locating and identifing gas and oil leakage and removing the same and Leak repairing by brazing/flaring of tubings of central type AC Plant of capacity 31 TR to 90 TR by leak testing, leak repairing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with and including double stage vaccume pump of atmospheric pressure less than 28 mm to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results complete all as specified and directed.
All as per item No. 50 here-in-before but suitable for UP to 28 TR AC plant complete.Nitrogen gas and refrigerant will be measured and paid separately as "supply only".
Material and labour in repair for checking and testing of interlock panel wiring,detecting the fault/defects including replacement of minor burnt wires, lugs, terminal, etc.,Complete all as specified and directed
Supply and fix in repair for new wet and dry bulb thermometer at A/C plant room Complete all as specified and directed
Supply only R-22 Refrigerant gas in returnable company sealed cylinder of 61kg each with test certificate of cylinder Complete all as specified and directed. Make : Mafron/Feron or Techno commercial equivalent as approved by GE. Note : (i) Hire charges of cylinder shall be deemed to be included in quoated rates. (ii) Refrigerant Gas (R-22) shall be incorporated under respective item of Sch (A) or where ever required.
Supply only Nitrogen Gas at required pressure for leak testing of central A/C plant Complete all as specified and directed
Supply only compressor oil N-68 after flushing out old oil of compressor and testing commissioning Complete all as specified and directed
Supply and fix in repairs for wornout / unservicable "V" belt for power transmission of following size and existing specification / cross section Complete all as specified and directed:- (a) C- 120
Supply and fix in repairs for unservicable pressure diffrential control cutouts of central type AC plants and testing of following Complete all as specified and directed:- (a) Oil pressure cutout MP-55
(b) High pressure cutout MP-1
(c) Low pressure cutout MP-5
Supply and fix in repairs pilot solenoid valve assembly for central type AC plant as per existing complete all as specified and directed.
Supply and fix in repairs water pressure gauge 4" dia with and including tube to match and stop cock for range 0 PSI to 150 PSI as per existing complete all as specified and directed.
Supply and fix in repairs pressure gauge 4" dia suitable for refrigerant R-22 and compressor oil including 1/4" copper pipe end to U shape with and including flair nuts/adopter at both ends,range of gauge -30 PSI to 300 PSI as per existing complete all as specified and directed.
Supply and fix in repairs thermometer to condenser/chiller, inlet or outlet water pipes including addition alteration to pipe line for fixing thermometer Range 0 degree F to100 degree F / degree centigrade as per existing complete all as specified and directed
Supply and fixing in repair water pressure gauge 0 kg / cm2to7 kg / cm2 any type Make Febig or Techno commercial equivant suitable makes as per PS.Complete all as specified and directed.
Supply and fix in repairs pressure relief valve of condenser 3/8" BSP threaded suitable for 300 PSI Complete all as specified and directed.
Supply and fix in repairs HRC fuses (Cylindrical / DIN type / Bolted) conforming to IS 13703 Part - II with high breaking capacity suitable for existing holders Complete all as specified and directed for the following capacities :- (a) 66 Amps to 160 Amps
(b) 200 Amps to 400 Amps
Supply and fix in repairs single phase preventer in electric panel board at central type AC plants Complete all as specified and directed
Supply and fix in repairs 3 pole power contactor , coil voltage 230 volts/415 Volts for following capacity motor. Complete all as specified and directed (a) 12 Amps to 25Amps
(b) 50 Amps to 90 Amps
(c) 150 Amps to 225Amps
Material and labour in repair for servicing the window type /Split type AC 1.5 TR/2.0 TR at site, cleaning evaporator, condensing coil by using carbon tetra chloride, combing the evaporator, condensor fins,greasing all the moveable parts of fan motor, testing the wiring of whole AC, checking all parts, cleaning the air filter and replacing the unserviceable spare parts, including cleaning the tray and refixing the back AC in position by providing proper packing for better effects, testing and commissioning of AC including marking of SM/MES No. Complete all as specified and directed
Material and labour in repair for disconnecting the water cooler of cap 40 liters/ 80 liters / Hr from electric and water connection at site and servicing the water cooler by cleaning condensor by using carbon tetra chloride combing the evaporator condensor fins, cleaning of water storage tanks greasing all the moveable parts of fan motor, testing the wiring and checking all parts and replacing the unserviceable spare parts including cleaning the tray and fixing back water cooler in position, testing and commissioning of water cooler, marking of SM/MES No.Complete all as specified and directed
Material and labour in repair for disconnecting, taking out old unserviceable Rotary sealed unit compressor from water cooler of any make, model and capacity 40 liters/80 liters and refixing new compressor and soldring to unit, testing of pressure including replacement of filter Complete all as specified and directed
Material and labour in repair for recharging of refrigrant gas R-134 and compressor oil for water cooler including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc; testing complete system on full load capacity Complete all as specified and directed
Material and labour in repair for rewinding of condenser fan motor of water cooler with supper enemalled copper wire of appropriate gauge including insuation, refixing and testing at location complete all as specified and as directed.
Material and labour in repair for worn out relay with over load protection for water cooler any capacity.Complete all as specified and directed Make : Sriram
Material and labour in repair for thermostat for water cooler Complete all as specified and directed Make : ANNAPURNA
Material and labour in repair for running capacitor 55+4 mfd, 230 volts Complete all as specified and directed Make : EPCOS
Material and labour in repair for running capacitor 50 mfd, 230 volts Complete all as specified and directed Make : EPCOS
Material and labour in repair for running capacitor 45mfd, 230 volts Complete all as specified and directed Make : EPCOS
Material and labour in repair for running capacitor 36 mfd, 230 volts Complete all as specified and directed Make : EPCOS
All as per sl item No. 91 here-in-before but capacity 10 Mfd Complete all as specified and directed Make : EPCOS
Material and labour in repair for starting capacitor 80 mfdto100 mfd 230 volts Complete all as specified and directed. Make : EPCOS
All as per sl item No.93 here-in-before but 40mfd to 60 Mfd.Complete all as specified and directed Make : EPCOS
Material and labour in repair for disconnecting and taking out old unserviceable sealed unit Rotary compressor from refrigerator of capacity 186 litres to 300 Litres single door / double door and provision of new compressor capacity 186 Litres to 300 Litres and testing to unit and testing complete all as specified and directed by Engr-in-Charge. Make : Techmsah
Material and labour in repair for recharging gas R-134 and compressor oil for refrigerator including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc, testing complete on full load capacity Complete all as specified and directed
Material and labour in repair for relay starting cum over load protection for refrigerator Complete all as specified and directed Make : ANNAPURNA
Material and labour in repair for thermostat switch suitable for 165 Litres / 286 litres / 310 litres refrigerator model S-1051 complete all as specified and directed by Engr-in-Charge. Make : ANNAPURNA / INDFOSS / RANUTROL.
Material and labour in repair for disconnecting, taking out old unserviceable sealed unit compressor from window type air conditioner capacity 1.5 Ton and provision of new compressor of same capacity and pressure testing complete all as specified and directed by Engineer-in-Charge.
Material and labour in repair for recharging refrigerant gas R-22 and compressor oil for window type AC 1.5 ton including flushing, pressure testing vaccumization the complete system and detection of leakage brazing etc; testing complete system on full load capacity Complete all as specified and directed.( Refrigerent Gas will be measured & paid seperately.)
Material and labour in repair for rewinding of condenser fan motor of window type AC with and including super enameled copper wire of same gauge including refixing and testing complete all as specified and directed.
Material and labour in repair for disconnecting and taking out old unserviceable sealed unit compressor from split air conditioner of cap 1.5 TR/2.0 TR and provision of new compressor of same capacity pressure testing complete all as specified and directed by Engineer-in-Charge.
Material and labour in repair for rewinding of condenser fan motor of split type AC any type with and including supper enameled, copper wire of same gauge including refixing and testing complete all as specified and directed by Engr-in Charge.
Material and labour in repair for charging of refrigerant gas R-22 and compressor oil in split type AC 1.5 TR capacity including vaccumising the complete system, detection of leakage, brazing etc, testing on full load Complete all as specified and directed Note:- Nitrogen, R-22 & Compressor oil shall be measured separately
Material and labour in repair for PCB of 1.5 Ton/2 Ton capacity window /split type AC with and including remote control kit ,connecting up and testing on load Complete all as specified and directed
Supply and fix in repair Single pole and neutral enclosure with and including a two pin and earth plug and socket complete with and including one single pole MCB 20 Amps from wall surface and fixing (AC Socket) for Window/Split AC Complete all as specified and directed
Supply and fix in repair, erection, testing and commissioning of 3 Way Mixing Valve 3 Way modulating proportional linear type motorised mixing valve BS 4504 PN 10-PN 40 having manual over ride facility with proportional thermostat and wiring with 1.5 sq mm copper conductor multi core armoured cable, 3 way valve size suitable for 80 mm pipe Complete all as specified and directed.
Supply and fix in repair, erection, testing and commissioning of 3 Way Mixing Valve 3 Way modulating proportional linear type motorised mixing valve BS 4504 PN 10-PN 40 having manual over ride facility with proportional thermostat and wiring with 1.5 sq mm copper conductor multi core armoured cable, 3 way valve size suitable for 65mm. Complete all as specified and directed.
Supply and fix in repair, erection, testing and commissioning of closed cell elastomeric nitrile rubber with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN 12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 kg/cum to 55 kg/cum. The insulation material shall be FM (Factory Mutual) USA approved and dust & fibre free. The Aluminium foil shall be 60 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3. Complete all as specified and directed in particular specifications. 13 mm thick thermal insulation
Supply and fixing in repairs 4 pole MCCB 200 Amps 415 V 25 KA with adjustable thermal and magnetic setting including spreaded links & extended rotary handle complete all as specified and directed.
Supply and fixing in repairs 4 pole MCCB 400Amps 415 V 16 KA with adjustable thermal and fixed magnetic setting including spreaded links & extended rotary handle complete all as specified and directed.
Supply and fixing in repairs 4 pole MCCB 250Amps 415 V 16 KA with adjustable thermal and fixed magnetic setting including spreaded links & extended rotary handle complete all as specified and directed.
Supply and fixing in repairs 4 pole MCCB 125 Amps 415 V 16 KA with adjustable thermal and fixed megnetic setting including spreaded links & extended rotary handle complete all as specified and directed.
Supply and fixing in repairs 4 pole MCCB 100 Amps 415 V 16 KA with adjustable thermal and fixed megnetic setting including spreaded links & extended rotary handle complete all as specified and directed.
Supply and fixing in repairs VAF meter for panel complete all as specified and directed.
Supply and fixing in repairs indication lamp red 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp yellow 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp blue 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp green 230 V complete all as specified and directed.
Supply and fixing in repairs indication lamp orange 230 V complete all as specified and directed.
Supply and fixing in repairs push button red with No/Nc element complete all as specified and directed.
Supply and fixing in repairs push button green with No/Nc element complete all as specified and directed.
Supply and fixing in repairs Add-on-block with 2 No & 2 Nc to match the contractor complete all as specified and directed.
Supply and fixing in repairs single phase preventer for panel complete all as specified and directed.
Supply and fixing in repairs overload relay 10 Amp to 13 Amp complete all as specified and directed.
Supply and fixing in repairs overload relay 6 Amp to 9 Amp complete all as specified and directed.
Supply and fixing in repairs control MCB SP 6 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs overload relay 32 Amp complete all as specified and directed.
Supply and fixing in repairs overload relay 40 Amp complete all as specified and directed.
Supply and fixing in repairs control MCB TP 20 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs control MCB TP 32 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs control MCB TPN 63 AMP 10 KA complete all as specified and directed.
Supply and fixing in repairs 3 way Auto/Manual switch 22.5mm Dia complete all as specified and directed.
Supply and fixing in repairs copper bus bar for panel as required complete all as specified and directed.
Supply and fixing in repairs 2mm thick sheet metal for existing panel of CRCA sheet duly powder coated including cutting, bending, grinding & refixing panel complete all as specified and directed.
Supply and fixing in repairs current transformer of capacity 200/5 1.5 va complete all as specified and directed.
Supply and fixing in repairs current transformer of capacity 100/5 1.5 va complete all as specified and directed.
Supply and fixing in repairs power & control wiring with PVC flexible copper cable single core of appropiate size as required for better funtioning complete with PVC cable duct & lugs complete for DOL & star-delta fedder complete all as specified and directed.
Supply and fixing in repairs, testing and commissioning totally enclosed weatherproof / waterproof electric CT Fan Motor three phase squirrel cage motor, Capacity 3 HP, 960 RPM, 415V, 50HZ with all connected accessories and all fitting suitable for 60 TR cooling complete all as specified and directed. Make Oswal / Sabar / Hindustan / Bharat Bijl
Supply and fixing in repairs CT Fan complete section Fan, Fan Dia1200 mm, connected GI nut bolts and accessories all fitting suitable for 60 TR cooling tower complete all as specified and as directed
Supply and fixing in repairs all accessories corrosion proof inlet louvers, drift, PVC eliminators, PVC water distribution system , GI nut bolt (included float valve)and all fitting complete all as specified and directed for cooling tower of capacity 60 TR complete all as specified and directed.
Supply and fixing in repairs set of FRP Panels & supporting structure made of hot dip galvanised pipes for 60 TR capacity cooling tower complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-2 using 20 mm graded crushed stone aggregate for staging of cooling tower, expansion tank, pipe supports, etc. including necessary form work complete all as specified and directed.
Supply and Fix in reapair AHU Pannel Fabricated AHU Panel of double - skin type Floor mountaed Top side discharge Air Handling Unit capacity 15000 CFM having corrosion resistant extruded aluminum hallow profile with thermal break, 16 gauge galvanized steel channel base frame 43 mm thick double skin pannel with pressure injected CFC & HCFC free PUF having 'K' value of 0.02 W/0C/ m & dinsity 40kg/m3 pre coated, pre - plasticized, galvanized outer and inner skin 0.06mm thick, Air tight casing using gasket and self-adhesive PVC Nylon hinges & handles, view port and marine lamp, limit switch, and SS -304 drain pan including air wisher systems with pipe line , nosel spray systems complete all as specified and directed.
supply and fix in reapair AHU Blower DIDW Fan Blower having outlet velocity not exceeding S. P. (mm wg) 50m/s to 60 m/s energy efficient fans with double inlet, double width forward or backward curved impellers for higg static pressure mounted on aluminum extruded siderail base Frame, as per existing AHU at bldg no 98 AC plant complete all as specified and directed.
Supply and Fix inreapair DX Type Cooling Coil 6 Row deep with anti- corrosion copper fins, as per existing AHU at bldg no 98 AC plant complete all as specified and directed.
supply and fix in reapair 4 pole 5.5 KW/4 pole/3 phase ( IE2) TEFC, squirrel cage induction motor , suitable for 415v +- 10% 50 Hz AC Supply complete all as specified and directed .
supply and Fix in repair HDPE washable 90% down 10 micron pre- filters, filters fixing framework, hinge type access doors, etc as per exsting AHU at bldg no 98 AC plant CFM 15000. complete all as specified and directed.
Supply, installation, testing & commissioning in repairs water cooled scroll type compressor 7 TR semihermatically sealed scroll motor with internal overload protector, compressor mounted on existing base including connecting with existing refrigerant pipe line , integral refrigerant piping and wiring accessories as required complete all as specified and directed including comprising of following :- a) Auto /Manual single phasing protection, b) Compressor restart protection, c ) 10 sec - time delay between system, d) Short circuit protection, e) 5 degree C anti freeze protection, f) Display on micro control indicating compressor on crank case heater on / off, g) Entering/ leving water temperature' h) Scroll chiller unit shall be suitable for 415 + 15% 50 C/S 3 phase AC supply, and Refrigerant used shall be R-22 or suitable for existing system as mentioned in specifications of manufacturer.
Supply, installation, testing & commissioning in repairs water cooled scroll type compressor ZR 19 Make Copeland of semihermatically sealed scroll motor with internal overload protector, compressor mounted on existing base including connecting with existing refrigerant pipe line , integral refrigerant piping and wiring accessories as required complete all as specified and directed including comprising of following :- a) Auto /Manual single phasing protection, b) Compressor restart protection, c ) 10 sec - time delay between system, d) Short circuit protection, e) 5 degree C anti freeze protection, f) Display on micro control indicating compressor on crank case heater on / off, g) Entering/ leving water temperature' h) Scroll chiller unit shall be suitable for 415 + 15% 50 C/S 3 phase AC supply, and Refrigerant used shall be R-22 or suitable for existing system as mentioned in specifications of manufacturer.
Supply only following spare part of cooling tower Make : Kool Drop / MIHIR / ADVANCE / HIMGIRI complete all as specified and directed :- (a) PVC fill in columns of size 60cm x 30cm x 15 cm or next higher size as per existing specification and requirement complete.
(b) PVC fill in columns of size 60cm x 15cm x 15 cm or next higher size as per existing specification and requirement complete.
Supply & Fix in repairs 10 Micron Filter class G3 as per EN 779 for AHU complete all as specified and directed of following size:- a)490mm x 610mm x 45mm
b) 500mm x 630mmx45mm
c ) 510mm x 610mm x 45
d) 500mm x 500mmx45mm
e) 510mm x 630mm x 45
f) 630mm x 630mm x 45mm
g ) 630mm x 510mm x 45mm
h) 590mm x 700mm x 45mm
i) 630mm x 500mm x 45mm
j) 630mm x 400mm x 45mm
k) 470mm x 630mmx 45mm
l) 500mm x 600mm x 45mm
m) 910mm x 720mm x 30mm
n) 600mm x 600mm x 45
o) 470mm x 610mmx 45mm
Supply & Fix in repairs double fitted polymer fabric HDPE fresh air filter(GL-type) washable/cleanable type having efficiency 95% to 99% down to particle size of 5 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over and including two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, including taking down complete all as specified and directed of following sizes :- a) 600mm x 600mm x 355mm
Material and labour in repair for Sub Zero for controlling & indicating humidity / temperature of central Plant along with humidity sensor length as per existing at site complete all as specified and directed.
Supply & Fix in repairs Cooling Pad of following Size for increasing humidity. a) 1900mm x 1300mm x100mm
Supply & Fix in repairs Humidification spray Pump 1 Hp. Monoblock pump set complete all as specified and directed.
Supply and Fix in repair STARTOR Rotor Stator sutiable for 100 HP motor 440V/ 400V Rotor volt 325 rotor amp. complete all as specified and directed.
Supply and fix in reapair for monoblock type condenser pump water Pump sutiable for 3 hp 33 meter Head self priming , single -stage , centrifugal volute type pump having cast iron casing , enclosed type dynamically balanced phosphor-n bronze/ SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearing, base plate mounting channel frame , Accessories and fittings viz. , mechnical seal TEFC squirrel cage induction motor having IE- 3 efficency and conformingn to 12615; 2018 suitable for operation on 3- Phase415v +- 10% 50 Hz ac supply complete all as specified and directed
Supply and fix in reapair for monoblock type condenser pump water Pump sutiable for 7.5 hp 33 meter Head self priming , single -stage , centrifugal volute type pump having cast iron casing , enclosed type dynamically balanced phosphor-n bronze/ SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearing, base plate mounting channel frame , Accessories and fittings viz. , mechnical seal TEFC squirrel cage induction motor having IE- 3 efficency and conformingn to 12615; 2018 suitable for operation on 3- Phase415v +- 10% 50 Hz ac supply complete all as specified and directed
Supply and fix in repair for monoblock type condenser pump water Pump sutiable for 10 hp 40 meter Head self priming , single -stage , centrifugal volute type pump having cast iron casing , enclosed type dynamically balanced phosphor-n bronze/ SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearing, base plate mounting channel frame , Accessories and fittings viz. , mechnical seal TEFC squirrel cage induction motor having IE- 3 efficency and conformingn to 12615; 2018 suitable for operation on 3- Phase415v +- 10% 50 Hz ac supply complete all as specified and directed
GRAND SERVICES
R. K. Industrial Fabricators
shakti engineering and electrical works
Shree Ayyappa Engineering
cooltech engineering services
PAMS ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .