Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-AOC | ₹7.8 Cr Quoted ₹8.1 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹9.0 Cr+₹91.8 L (11.4%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹9.0 Cr+₹91.8 L (11.4%) | L2 | Rejected-Finance Not being lowest bidder |
| 3 | L3₹9.1 Cr+₹98.9 L (12.3%)Rejected-Finance | ₹9.1 Cr+₹98.9 L (12.3%) | L3 | Rejected-Finance Not being lowest bidder |
Tender Value
₹7.7 Cr
EMD Value
₹7.1 L
Closing Date
4 Oct 2022, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVN OF CERTAIN OTM ACCN INCLUDING LIVING-IN ACCN AT AF STN DINJAN UNDER GE (AF) MOHANBARI
2022_MES_525207_2
88638/DIN/E8
Open Tender
Civil Works
Lump-sum
730 days
Mohanbari
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE AF MOHANBARI
₹7.1 L
Yes
17 Nov 2022
5 Sept 2022
6 Oct 2022
5 Sept 2022
4 Oct 2022
20 Sept 2022
Amount
NOTE (Applicable for all Parts/ Items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced Schedule is given in tender documents
SCHEDULE 'A' PART- II ( SITE CLEARANCE AND AREA DEVELOPMENTS) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- III (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- V (ROAD, CULVERT AND CONCRETE DRAIN) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VI (COMPOUND WALL AND GATE) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- VIII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- IX (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- X (EXTERNAL ELECTRICFICATION) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- XI (AIR CONDITIONING AND REFRIGERATION) Details of prepriced Schedule is given in tender documents
SCHEDULE 'A' PART- XII (STANDBY POWER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XIII (FIRE ALARM) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XIV (LIGHTENING ARRESTER) Details of prepriced Schedule is given in tender documents.
SCHEDULE 'A' PART- XV (DEMOLITION/DISMANTLING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XVIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK Removing excavated soil to a distance exceeding 50 m but not exceeding 250 m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY S&F concealed MCCB DB, double door, vertical type, TPN, 415 V, 160 Amps, 8 way or 24 modules, IP 43 suitable for MCCB of 160 Amps, 36 KA as incomer and MCB SP/SPN as outgoing complete with suitable busbar, neutral link, earth link complete all as specified and as directed. [Note:- (a) MCCB/ MCBs shall be measured and paid separately. (b) Blank space shall be covered with blank plates and cost of same shall deemed to be included in the unit rate.]
S&F concealed MCCB DB, double door, vertical type, TPN, 415 V, 63/ 100 Amps, 4 way or 12 modules, IP 43 suitable for MCCB of 100/ 63 Amps, 36 KA as incomer and MCB SP/SPN as outgoing complete with suitable busbar, neutral link, earth link complete all as specified and as directed. [Note:- (a) MCCB/ MCBs shall be measured and paid separately. (b) Blank space shall be covered with blank plates and cost of same shall deemed to be included in the unit rate.]
S&F MCB single pole of capacity 6 to 32 amps, C-curve, 10 KA breaking capacity and making connection complete all as specified and directed.
S&F MCB SPN of capacity 6 to 32 amps, C-curve, 10 KA breaking capacity and making connection complete all as specified and directed.
S&F MCCB 415 volts, 3 pole, 160 Amps, 50 Hz, 36 KA with thermal magnetic release type and making connection complete all as specified and directed.
S&F MCCB 415 volts, 3 pole, 100 Amps, 50 Hz, 16 KA with thermal magnetic release type and making connection complete all as specified and directed.
S&F MCCB 415 volts, 3 pole, 63 Amps, 50 Hz, 16 KA with thermal magnetic release type and making connection complete all as specified and directed.
S &F LED light fittings, 1x20 Watt, 220 volts AC, 4 feet, decorative box type with driver including LED tube light 20 watt, prewired & including coneecting up with and including one run of PVC insulated copper conductor wire 1.5 sqmm 3 core PVC insulated, sheathed copper conductor cable from ceiling rose complete in all respect all as specified and directed.
S &F LED light fittings with high output diffuser, 2 feet, 10 Watt, 220 volts AC, decorative type with driver including LED lamp 10 watt, prewired & including coneecting up with and including one run of PVC insulated copper conductor wire 1.5 sqmm 3 core PVC insulated, sheathed copper conductor cable from ceiling rose complete in all respect all as specified and directed.
S&F LED security light fitting 1x30 watt with integral reflector made of alluminium alloy LM6 with LED driver, lamp, surge protector and all accessories pre-wired including connection with and including one run of PVC insulated copper conductor wire 1.5 sqmm 3 core PVC insulated, sheathed copper conductor cable including 40mm bore medium grade GI pipe as bracket, 1.5 m long, bent to shape with MS clamp of size 40 x 5mm complete all as specified and directed.
Supply, hanging & testing of energy saving non-decorative ceiling fan 230 volts, single phase AC, 1200mm sweep, BEE five star rated, Brushless Direct Current (BLDC) without remote type with accessories like holding down rod, hanging clamps, blades, fan hook including writing MES number (as per standard practice) and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.
Supply, hanging & testing of exhaust fan with suitable metalic louvers, metalic body, 300 mm sweep, 230 volts single phase, AC supply, 50 Hz, 900 / 950 RPM, heavy duty, with blades, frame including provision of three core twisted flexible wire copper conductor cable of size 1.5 sqmm from ceiling rose to exhaust fan including connection complete all as specified and directed.
S&F angle holder, ISI marked, fancy type with and including LED lamp 7 watt complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified and directed. [Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c) Excavation/earthwork is deemed to be included in the quoted rate.]
INTERNAL WATER SUPPLY. S&F 15 mm bore brass angle stop cock CP high pressure with capstan head, long shank screwed down complete all as specified and directed.
ROAD, CULVERT AND CONCRETE DRAIN. M & L for 250mm thick GSB (Granular Sub-Base) grade I as per TI:09/2018/Table 400-1 of MORTH Specification/ IRC Specification, spreading in layers not exceeding 150 mm thick each, watering, ramming / rolling by tandem vibrator roller and finishing to longitudinal gradient (1:150) & transverse gradient (1:100) and required camber for achive field compaction at least 98% of MDD (maximum dry density) determined using modified procter density determination method as per IS code, complete all as specified and directed.
Material & Labour for construction of 100 mm thick cement concrete as Dry Lean Concrete Base Course of compressive strength not less than 10 MPa at 7 days for each consecutive group of 5 cubes of individual strength of cube shall not less than 7.5 MPa at 7 days using aggregate not exceeding 26.5 mm, with minimum cement content shall not be less than 150 kg/cum including spreading and compacted by using mechanical paver and vibratory roller to thickness of 150 mm including necessary form work finshing etc complete all as specified and as per TI/ MORTH specification 601, complete all as specified and as directed. NOTE:- (a) No price adjustment shall be applicable if quantity of Cement content used in the work as approved in the Design Mix exceeds 150 Kg. (b) The rate quoted shall be inclusive of use and waste of form work for total thickness.
Material and labour for sand cushioning (10mm thick), with clean river sand spread evenly, levelled to uniform thickness, rammed including watering, laid over DLC, complete all as specified and as directed. (Note: Compacted thickness shall be measured for payment)
Supply and laying 400 Micron thick transparent HDPE Polythene film of GRADE-I conforming to IS-10889 (minimum weight 390 gm/Sqm) over sand cushioning, as anti-friction layer on the base course of road work as per specification with specified overlap between adjacent strip and transverse joint etc, complete all as specified and directed. Note: Side lap shall be 150 mm and end lap shall be 300 mm. The rate quoted shall be deemed to include for the laps.
COMPOUND WALL AND GATE. M & L for preparation of newly plastered surfaces of walls and applying wall care putty (white) of thickness not less than 2mm and sand papering surfaces to achieve smoothness of the surfaces and applying exterior emulsion paint 100% acrylic, white or any tinted (as in camouflage pattern), over a coat of cement based primer, including washing floors, cleaning glasses, joineries, electrical fittings, wiring etc, or drops and splashes complete all as specified and directed.
SEWAGE DISPOSAL Construction of Septic Tank for 50 users complete all as shown on drawings and as specified.
Construction of Septic Tank for 100 users complete all as shown on drawings and as specified.
Construction of Soakage Well for 50 users complete all as shown on drawings and as specified.
Construction of Soakage Well for 100 users complete all as shown on drawings and as specified.
EXTERNAL WATER SUPPLY M&L PP-R Gate valves (brass insert) for 110 mm outer dia pipe complete all as specified and directed.
M&L for construction of brick masonry valve pit chamber of internal dimension 900 x 900 x 900 mm depth with sub class 'B', old size, in CM (1:4) and 10mm thick plastering in CM (1:4), 15mm thick PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate ) as in foundation lean concrete, PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in bedding and copping MS frame with 40x40x5mm angle iron 5mm thick MS sheet cover plate with locking arrangement including 50mm pad lock with double key, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preperation of surface ,three coats of white wash on plastered suface (exposed to view ) including necessary excavation in soft loose ,soil ,returning filling in and removal of surplus soil to a distance not excedding 50 m complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for connecting of water supply pipe line in 100 mm bore existing pipe line including cutting, threading of existing and new pipe line including fittings like tee, nut bolts, gasket for making the joint leak proof complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, install, testing and commissioning of outdoor type transformer step down, copper wounded having primary side for HT Three Phase 11 KV & secondary for 3 phase 433 Volts, 4 wire 50 Hz of capacity 160 KVA as per IS-1180 Part-I, Level-II (as per latest amendment) with and including the following specification:- (i) No load voltage ratio-11KV/ 0.433 KV, (ii) Nos of phase-three. (iii) Type of cooling- ONAN, (iv) Frequency-50 Hz, (v) Vector group-DYN 11, (vi) Two earthing terminals for body earthing and two additional for neutral, (vii) Oil level gauge indicating oil level with minimum and maximum indication, (viii) Lifting lugs rollers and MS terminal Box on both HT and LT side, (ix) Rating and terminal marking plates, (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects (xi) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug, (xii) Thermometer pocket, (xiii) Oil filling hole( 1-1/4" Nominal size thread) with cover (transformer wih conservator), (xiv) Connection-Delta/Star, (xv) Temperature rise in oil-40 deg celcius, (xvi) Temperature rise in windings- 45 deg Celcius, (xvii) Material winding-Copper wound, (xviii) High voltage/low voltage with cable box, (xix) Service-Outoor type, (xx) Neutral- Internally conneted with earthing lead and bush, (xxi) Off load tap changar (+5% to -10% in steps of 2.5% with 7 position), (xxii) First filling of transformer oil upto recommended level.
Serial Item No. 16.30 (Contd....) NOTE :- 1. The contractor/manufacturer shall furnish original certificate (paid voucher and test certificate) of the CRGO manufacturer. 2. The manufacturer /contractor shall furnish the diameter of LV and HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. 3. The contractor shall get the approval of GE for the make of the transformer they plan to procure. 4. Prior to manufacturing the general arrangement drawing design details of the transformer shall be got approved by GE. 5. Transformer shall be dispatch only after inspection clearance by inspecting officer detailed bu Accepting Officer. 6. Necessary foundation with plinth shall be provided as per manufacturer's recommendation, quoted rate shall be deemed to be included accordingly.
M&L for Earthing complete with GI earth plate elecrode of size 600 mm × 600 mm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work pre-cast RCC(1:2:4) type B-1 pit cover 50mm thick, reinforced with 8mm dia TMT bars @100 mm c/c both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:2:4) type B-1 concrete pit and angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect, protected by 40 mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed. [Note : (a) The unit rate includes for protection pipe and earth strip upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c) Excavation/earthwork is deemed to be included in the quoted rate.]
S&F LED street light 70 W, 230 volt, AC, 50 Hz endura pearl plus energy saving, environmental friendly, long life exclusive innovation pressure dia cast aluminium IP 66 bay light with high power LEDs as light source and impact resistance of IKO7 with 10 KV Built-in Surge protection device complete all as specified.
S&F cable junction box IP 66 “halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) minimum size 260 x 210 x 116 mm suitable for 16/25 sqmm, 4 core cable fixed to pole with suitable FI clamp 20X3 mm nuts, bolts and washers incl 01 No miniature circuit breaker (MCBs) single pole, 240 volts, 10 KA, 10 Amps and incl suitable capacity aluminium bus bar (minimum 100 Amps-04 Nos) mounted on insulator complete all as specified and as directed.
S&F PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, three core of copper conductor for connection of street light fittings on pole from junction box including termination clip complete all as specified and directed.
S&F of GI bracket made out of 40 mm GI pipe light grade bend for fabrication to shape as required minimum length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps nuts & bolts complete all as specified and directed
M&L for PCC root indicator of width 45cm, depth 10cm & height 100cm overall embedded to the depth not less than 45cm below ground level including necessary earth work suitable for mounting on root of underground cable complete all as specified and directed.
AIR CONDITIONING AND POWER CONVERTER SUPPLY Supply, installation, commissioning and testing of Voltage stabilizer for primary switching technology,high power efficiency , built in thermal overload protection ,low & high voltage cut-0ff protection ,single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
STANDBY POWER SUPPLY Supplying, installation of silent Diesel Engine Driven generating set 415 volt ,3 phase 4 wire 0.8 PF,engine as per IS 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for Automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation of capacity 160 KVA Comprising and including of following:- (A) DIESEL ENGINE: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete with following:- (a) Radiator with blower fan or heat exchangar with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter complete with first filling of lub oil (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed.
Serial Item No. 16.42 (Contd....) (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class (s) Self starter (t) Electric operated electronic governor. (u) Fuel injection pump.
Serial Item No. 16.42 (Contd....) (v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) Battery as per manufacturer recommendation. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (viii) Safety control (Trip and indication). (ix) High water temperature (x) Low lube oil temperature (xi) Overspeed stop (B) ALTERNATOR - Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 160 KVA ,minimum power factory 0.8, 1500 RPM , insulation class 'H' salient pole, revolving field, single bearing automatic voltage regulator and directly coupled with engine. (C) ENGINE INSTRUMENT PANEL- (i) Digital type controller able to display- alternator voltage, battery voltage, load current, fuel level, lub oil pressure, frequency, RPM and able to stop generator on any fault and to display parameters i.e. low battery,LLOP, under voltage, over voltage, High engine temperature and other protection as per manufacturer recommendations including necessary wiring set of relayss, MCB/Fuse etc complete. (ii) Engine start and stop switch (iii) Emergency Stop Switch (iv) DC power supply suitable for controller.
Serial Item No. 16.42 (Contd....) (F) DIESEL STORAGE TANK: Fuel tank of MS sheet of capacity not less than 12 Hrs continuous operation on full load with fuel level guage, drain plug, locking arrengements, etc including connection to Engine through fuel filter/ manual feed pump as per manufacturer recommendation. (G) ACOUSTIC ENCLOSURE: Sheet metal fabricatedcope type silent enclosure manufactured on CNC machines as per CPCB norms and power coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, laveling certification etc as laid down in GSR No.371(E) dt 17 May 2002 or latest. (H) FOUNDATION: Foundation/ plinth shall be provided as per manufacturers recommendation. (J) MISC: Tool kit operation, maint cat, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturers standard practice.
M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using copper earth strip 20 x 3.15 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipment/ panel/ test point at another end, earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles including excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I and testing on completion complete all as specified and directed. [Note : (a) The unit rate includes for protection pipe and earth strip upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c) Excavation/earthwork is deemed to be included in the quoted rate.]
ARBORICULTURE (SCHEDULE 'A' PART- XVI) Supply & stacking of good earth from out side of MD land (Earth manure is stacks will be reduced by 20% for payment complete all as directed.
Supply & staking of Dump manure screened through sieve of IS designation 16 mm complete all as directed.
Mixing & spreading of earth with Dump Manure in required thickness complete all as directed.
Supply and land scaping/ plantation of Barmudas/American grass/carpet grass, small size and refilling the same with the excavated earth mixed with manure/Sludge/Cow dung in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surlus soil) complete all as specified and directed. (Note: Cost of manure and earth shall be paid seperately.)
Supply and planting of Nahar trees with Height 3 to 4 feet including Digging Holes 1.2 m Dia x 1.2 m deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge/Cow dung / manure after reduction by 8% flooding with water and removal of Surplus soil) complete all as specified and directed. (Note: Cost of manure and earth shall be paid seperately.)
SCHEDULE "A" PART-XVIII (SCHEDULE OF CREDIT) Note :- Amount of Rs 13350.00 indicated in Tender as Schedule of Credit i.e. Schedule 'A' Part-XVIII shall be deducted from the total quoted amount of BOQ_REV_1.
ms singh construction
AKASH CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .