Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1Itemwise₹110.41Accepted-AOC | L1Itemwise | Accepted-AOC L1 ITEMWISE | |
| 2 | L1Itemwise₹364.29Accepted-AOC | L1Itemwise | Accepted-AOC L1 ITEMWISE | |
| 3 | L1Itemwise₹18,970.30Accepted-AOC | L1Itemwise | Accepted-AOC L1 ITEMWISE | |
| 4 | L1Itemwise₹8.4 LAccepted-AOC | L1Itemwise | Accepted-AOC L1 ITEMWISE |
Tender Value
₹90 L
EMD Value
₹1.8 L
Closing Date
17 Sept 2024, 5:00 pmClosed
SUPERINTENDENT PBM AG HOSPITAL BIKANER
OFFICE OF SUPERINTENDENT PBM AG HOSPITAL BIKANER
SUPPLY OF VARIOUS TYPE OF TEST KITS AND CONSUMABLES FOR BIOCHEMISTRY DEPTT (1 YEAR)
2024_SPMCB_411048_1
ENIB 04 (2024-25)
Open Tender
Consumables (Hospital / Lab)
Item Rate
365 days
OFFICE OF SUPERINTENDENT PBM AG HOSPITAL BIKANER
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
1000SUPERINTENDENT PBM AG HOSPITAL/1500MD RISL
₹1.8 L
25 Feb 2025
5 Aug 2024
18 Sept 2024
5 Aug 2024
17 Sept 2024
5 Aug 2024
Amount
Serum Sugar (Liquid stable, ready to use, Linearity ≥700mg/dl, Kinetic)
Serum Urea-(Liquid, ready to use, Kinetic, Linearity ≥300 mg/dl
Serum Albumin- (Liquid, ready to use, End Point, Linearity ≥ 7g/dl)
Serum Total Cholesterol- (Liquid stable, ready to use, End Point, Linearity ≥1000mg/dl)
Serum Triglyceride- (Liquid, ready to use, End Point, Linearity ≥1000mg/dl)
Serum Calcium- (Liquid Stable Ready to use, End Point, Linearity ≥ 15 mg/dl
Serum Uric Acid- (Liquid, Stable Ready to use, End Point, Linearity ≥ 20mg/dl)
Serum Creatine Phosphakinase (CK-NAC/CPK) (Liquid, Stable, Ready to use, Linearity ≥ 1500 U/L)
Total & Direct Billirubin (Liquid stable, Ready to use, Fixed Time, linearity ≥20 mg/dl)
SGPT- (Kinetic, Linearity ≥ 300 unit/lt., IFCC method, Liquid Stable reagent)
Lipase (Liquid stable, Ready to use, Kinetic, linearity ≥300 U/L)
CSF Microprotein (Liquid stable, Ready to use, Linearity ≥400 mg/dl)
Magnesium (Liquid stable, Ready to use, End Point)
HDL-Cholesterol (Direct clearance method, Linearity ≥180 mg/dl.
Adenosine deaminase- For Fully Auto Analyzer supply with calibrator and quality control
Iron and TIBC
CSF quality control
Multi Calibrator for fully auto analyzer (for Calibration of above Biochemical Parameters. Calibrator should be traceable to Internationally accepted norms. Calibrator will run as per requirement time to time.
Multi Control for fully auto analyzer (Control of high, normal/low will run daily) for above Biochemical Parameters. Should be traceable to Internationally accepted norms.
Serum Total Cholesterol- (Liquid stable, ready to use, End Point, Linearity ≥1000mg/dl)
Serum Triglyceride- (Liquid, ready to use, End Point, Linearity ≥1000mg/dl)
Total & Direct Billirubin (Liquid stable, Ready to use, Linearity ≥10 mg/dl, preferably single reagent (Diazo with Sulphanilic acid)
Serum Albumin- (Liquid, ready to use, End Point, Linearity ≥ 7g/dl)
Serum Total Protein- (Liquid, ready to use, End Point, Linearity ≥ 15g/dl )
Serum Calcium- (Liquid, ready to use, end point Linertiry ≥20mg/dl)
Serum Phosphorus- (Liquid, ready to use, end point Linertiry ≥15mg/dl)
Hitachi Sample Cup, (Polystyrene, highly transparent, non-sticky, 17mm x 38mm or 2mL)
Disposable Test Tube (12 x 75mm with Rim, 5ml capacity, Bottom Round, Autoclavable and Thermal Resistant, highly Transparent
White Paper Laboratory Tissue Roll (for Cleaning of Equipments, Pattern Plane and should be thick and not leave the rashes or fibers on cleaning surfaces)
Sodium hypochlorite solution (5-10% )
Disposable Assay Tip on Rack (tip size 0-200 µl)- Should be Universal, should have minimize liquid retention, highly transparent, made of non-sticky material and also must be graduated marking at various levels at 50, 100, 150 & 200.
Disposable Assay Tip on Rack (tip size 100-1000 µl)- Should be Universal, should have minimize liquid retention, highly transparent, made of non-sticky material and also must be graduated marking at 100, 250, 500, 750 &1000µl.
Marker Pen Fine Tip (Red/Black/Blue, usable on glassware)
Filter Paper(24 inches x24 inches)
Aliquot for quality control and calibrator preparation (1.5 ml)
Sample Transport Box with carry handle, (as per picture but Non-transparent) • To transport 13x75 blood collection tubes for Sturdiness from home collection to lab or hospital . Comes with inbuilt temperature indicator. • Polycarbonate construction and available in three colors for user/owner identification • Silicone water-tight seal and three lid clasps provide secure closure • Lid opens a full 180°, allowing total access to contents and making it easier to clean • Will accommodate 13 and 16 mm tubes in a minimum 72-place OneRack, or similar sized • Use the separators provided to create your own compartment sizes, or use empty to transport larger products and equipment • Autoclavable
Hand Sanitizer (Liquid, concentration of contains according to WHO guidelines)
Hand wash (Liquid)
Blood Sample Collection Tube Size for Adult 7 ml capacity - 1. Additive :- Serum Separating Gel (SSG) and Clot Activator. (Gel present at bottom of tube and should be stable in physio-chemical variation and avoid high temperature decomposition or molecules precipitation). 2. Color Coding of Cap :- Red in colour (Screw cap preferred), Non-vacutable tube 3. Should be sterile, with safety closure and single hand operation for capping and decapping. 4. Should have fill mark to indicate the draw Volume. 5. CE/FDA certified. 6. Toxicity Certificate and Batch wise sterility/pyrogenicity certificate should be provided. 7. The tube should contain a label for noting the patient’s details. 8. Expiry date should be printed on the tube. Shelf life should be minimum 12 months or more from the date of manufacturing.
R.K.Enterprises (BID ID -2928578)
Progene Biotech (BID ID -2909091)
annu surgical and diagnostic store bikaner (BID ID -2904969)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .