| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹40.5 L+₹6.3 L (18.6%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹47.7 L+₹13.6 L (39.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
REPAIRS / MAINTENANCE TO LT DISTRIBUTION NETWORK WITH CONVERSION OF SOME OH LINES INTO UG CABLES AT A PARK, B PARK, OLD PARK AND ARSENAL DEPOT OF CAFVD UNDER AGE E/M-II IN GE (CENTRAL) KHADKI.
2023_MES_605645_1
8855/E8 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CAFVD area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹99,000
Yes
30 Sept 2023
26 Jun 2023
26 Jul 2023
26 Jun 2023
24 Jul 2023
11 Jul 2023
26 Jun 2023 - 4 Jul 2023
Amount
Supply, Laying , jointing and testing 10 Sqmm 2 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and as directed .
Description all as per item No 1 above but 10 Sqmm 4 core
Description all as per item No 1 above but 16 Sqmm 4 core
Description all as per item No 1 above but 25 Sqmm 4 core
Description all as per item No 1 above but 35 Sqmm 3.5 core
Description all as per item No 1 above but 50 Sqmm 3.5 core
Description all as per item No 1 above but 70 Sqmm 3.5 core
Description all as per item No 1 above but 95 Sqmm 3.5 core
Description all as per item No 1 above but 120 Sqmm 3.5 core
Description all as per item No 1 above but 150 Sqmm 3.5 core
Description all as per item No 1 above but 185 Sqmm 3.5 core
Description all as per item No 1 above but 300 Sqmm 3.5 core
Description all as per item No 1 above but 400 Sqmm 3.5 core Note for Item No 1 to 13. (i) During earth work for laying of cable, any damage to the existing services will be made serviceable without any extra cost within 24 hrs. (ii) Credit of Sch for cable has not been considered for complete qty because conversion of ACSR will be done at some places. (iii) Contractor should visit the site before quoting the rate for understanding the scope of work.
Supply and fix 100 mm bore galvanised iron tubing, light grade with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of the following bores :-
Description all as per item No 14 above but 80 mm bore
Description all as per item No 14 above but 50 mm bore
Description all as per item No 14 above but 40 mm bore
Material and labour for cutting through existing bituminous road /PCC/floor/Stone block Tank road along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finishes complete all as specified and directed. NOTE :- Contractor should visit the site before quoting the rate & GI Pipe will be measured and paid seperately in respective item.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches n.exc. 1.5 mtr in wide and exc. 1.5 mtr but n. exc 3.0 m in depth and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/disintegrated rock complete all as specified and directed.
Material and labour for sand/fine dust cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge NOTE :- punning thickness of 18 cm will be measured for payment
Supplying and laying precast, PCC LT cable cover, class LV, type flat , size 250mm x 150mm x 40mm complete for protection of underground cable all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Taking out serviceable/unserviceable electric cable of any size any type from excavated trenches on pole/on wall etc.
Taking out Serviceable/unserviceable PCC LT Cable cover from excavated trenches Note for item No. 26 & 27 :- Serviceable cable and stone patti kept in safe custody for re-use at site and serviceability shall be ascertained by Eng-in Charge.
Relaying the electric cable of any size in the excavated trench on pole/wall etc retreived from item No. 27 after checking and rectifying the fault.
Relaying the PCC LT Cable cover in the excavated trench retreived from Ser item No.4 & 5
Material and labour for two coats of dry distemper including preparation of old wall surfaces complete all as specified and as directed by Engr-in-Charge at site.
Material and labour for two coats of cement base paint, white or tinted on old decorated surfaces of wall complete all as specified and as directed by Engr-in-Charge.
Material and labour for Dismantling of ACSR conductor HT/LT on any type of pole, cradle guard and earthing wire complete all as specified and directed by Engr-in-Charge.
Supply, stringing, streching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified and as directed .
Lopping / proning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 1 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as directed. NOTE :- (a). The trees branches etc will be removed from site and stack as directed and will not be carried away by the contractor as the wood belongs to CEO / DEO. (b). Prooning of all tree branches in per Span (not less than 30 Mtr) in HT/ LT OH Line shall be measured as one Job. (c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
Material and labour in replacement cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding , bending cold or hot, drilling holes for bolts, in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed
Supply and fix pin type porcelain , vitreous white, brown or green insulator including galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia wahsers, bolts etc as working pressure 1100 volts complete all as specified and directed.
Supply and fix shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height in 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and as directed.
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 63 to 100 Amps breaking capacity 16KA complete all as specified and as directed . MAKE :- Legrand or equivalent in Schneider/Havells/ CG/ L&T.
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 125 Amps breaking capacity 16 KA. complete all as specified and as directed. MAKE :- Legrand or equivalent in Schneider/Havells/ CG/ L&T.
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 200 Amps breaking capacity 36 KA complete all as specified and as directed. MAKE :- Legrand or equivalent in Schneider/Havells/ CG/ L&T.
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 250 Amps breaking capacity 36 KA complete all as specified and as directed. MAKE :- Legrand or equivalent in Schneider/Havells/ CG/ L&T.
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 400 Amps breaking capacity 37 KA. MAKE :- Legrand or equivalent in Schneider/Havells/ CG/ L&T.
Material and labour for straight through ( Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm including dismantling the old burnt cable joint termination.
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm including dismantling the old burnt cable joint termination.
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm including dismantling the old burnt cable joint termination.
Material and labour for disconnecting LT XLPE cable of any size from LT Panel or any location as directed for finding fault and Material and labour for defect rectification underground cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. all as directed. NOTE :- (i) The fault locating equipments will be brought to site within the 12 hours of instruction from Engr-in-Charge. (ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and has to be rectified within 12 hours after notification, failing which Rs 500/- per day per complaint will be recovered from the dues to the contractor. (iii) Rates included necessary earth work for opening cable for ready to jointing.
Supply, installation, commissioning and testing of indoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar of 2400 Amps capacity with an extensible bus bar connecting for other panel , pre-wired and, fabricated in any CPRI Approved panel factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 2.00mm thick CRCA mild steel sheet including suitable stainless steel nuts, bolts & washers for incoming/Outgoing feeder etc duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:- Incommer :- ACB 4 pole 1600A, 36kA, Manual draw out type - 01 Nos Outgoing :- (a) MCCB 4 pole 630A, 36kA, thermal & magnetic release - 01 Nos (b) MCCB 3 pole 400A, 36kA, thermal & magnetic release - 04 Nos (c) MCCB 3 pole 250A, 25kA, thermal & magnetic release - 04 Nos (d) MCCB 3 pole 160A, 25kA, thermal & magnetic release - 03 Nos (e) MCCB 3 pole 100A, 16kA, thermal & magnetic release - 04 Nos (f) Digital Multifunction meter & indicator set (RYB) - 01 Set MAKE :- Legrand / ABB/ Schneider / Havells
Description all as per item Ser No 47 above but comprising of following :- Incommer :- ACB 4 pole 1600A, 36kA, Manual draw out type - 01 Nos Outgoing :- (a) MCCB 4 pole 630A, 36kA, thermal & magnetic release - 01 Nos (b) MCCB 3 pole 400A, 36kA, thermal & magnetic release - 04 Nos. (c) MCCB 3 pole 250A, 25kA, thermal & magnetic release - 04 Nos. (d) MCCB 3 pole 160A, 25kA, thermal & magnetic release - 05 Nos (e) Digital Multifunction meter & indicator set (RYB) - 01 Set MAKE :- Legrand / ABB/ Schneider / Havells
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar 400 Amps capacity, pre-wired and CPRI approved manufactring fabricated, duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet including suitable stainless steel nuts, bolts & washers for incoming/Outgoing feeder etc duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:- Incommer :- (a) MCCB 4 pole 250 A, 25kA, thermal & magnetic release - 01 Nos Outgoing :- (a) MCCB 3 pole 100A, 16kA, thermal & magnetic release - 03 Nos (b) MCCB 3 pole 63A, 16kA, thermal & magnetic release - 02 Nos (c) Digital Multifunction meter & indicator set (RYB) - 01 Set MAKE :- Legrand / ABB/ Schneider / Havells
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar 200 Amps capacity, pre-wired and CPRI approved manufactring fabricated, duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 3.00mm thick CRCA mild steel sheet including suitable stainless steel nuts, bolts & washers for incoming/Outgoing feeder etc duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:- Incommer :- (a) MCCB 4 pole 100 A, 25kA, thermal & magnetic release - 01 Nos Outgoing :- (a) MCCB 3 pole 63A, 16kA, thermal & magnetic release - 04 Nos (b) Digital Multifunction meter & indicator set (RYB) - 01 Set MAKE :- Legrand /ABB/ Schneider/Havells
Supply, installation, commissioning and testing of outdoor type Outgoing Bus Bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, of capacity 250 Amps fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 . The panel shall be made out of 3.00mm thick CRCA mild steel sheet , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. Incommer :- (a) MCCB 4 pole 250A, 36kA, thermal & magnetic release - 01 Nos MAKE :- Legrand or ABB/ Schneider/Havells
Supply, installation, commissioning and testing of outdoor type Outgoing Bus Bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, of capacity 100 Amps fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 . The panel shall be made out of 3.00mm thick CRCA mild steel sheet , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. Incommer :- (a) MCCB 4 pole 100A, 16kA, thermal & magnetic release - 01 Nos MAKE :- Legrand or ABB/ Schneider/Havells
Material and labour for earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 88mm dia medium grade and inner pipe 55 mm dia including testing, 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolits and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 kg bags of carbon based earthing compound. The resistance of the compound should be less than 0.1 Oms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between7-9. Connected to the earthing test point, Fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning filling & removal of extra soil , to achieved earth resistance value less than 5 Oms including testing complete all as specified Make U-Protect or equivalent NOTE: IF the desired result not obtained after testing the contractor should do re-eathing without any extra cost.
Material and labour for connecting galvanised iron ( GI ) strip 32 X 6 mm, in replacement to the existing earthing to eqpts complete all as specified.
M/S. Niksun Electro-Infra Private Limited
Mahindra Electric Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .