| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹43.6 L+₹24.4 L (127.8%)Rejected-Finance SKALZANGLING AIR PORT ROAD LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹46.3 L+₹27.2 L (142.1%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹47.6 L+₹28.5 L (149.0%)Rejected-Finance BRAJANATHCHAK TOWNSHIP HALDIA HALDIA HALDIA | MEDINIPUR EAST | WEST BENGAL | 721605 | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹48.5 L+₹29.3 L (153.4%)Rejected-Finance DHA BEMA | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Apr 2024, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR PREVENTIVE MAINT AND SERVICING OF DG SETS AND OTHER ACCESSORIES AT SECTOR C UNDER AOR OF AGE EM I OF GE 865 EWS
2024_MES_646783_1
865/EWS(NIT-21)/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹90,000
Yes
19 Jun 2024
16 Mar 2024
13 Apr 2024
16 Mar 2024
6 Apr 2024
30 Mar 2024
Amount
Periodical Maintenance such as replacement of Engine Oil, Oil filter, Air filter and diesel filter, cleaning of air filters, replacement of water hose, cleaning of filter housing etc of Diesel engine generating sets including replacement of rusted and defective nuts, bolts, and washers etc as required at site of following capacity,one in a quarterly duration all as directed. A (CHECK) Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comparising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engg - In - Charge . (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and correcting the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tenson properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (CHECK) (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE (i) Cost of Spares required will be paid and measured separately (ii) Servicing/routine check up carried out through authorised service centre of manufacturer (III) Make of spare recommendation by auth service centre of manufacturer (ii)Periodical maintenance/ servicing of DG Set shall to be carried out at every 250 hrs to maintain the serviceability of DG Set.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
M&L for changing / Toping up of best quality of engine oil 20W40 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed . Make:-Castrol/ Veedol/Valvoline
S&F in replacement of Oil filter element as per existing for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge. Make- Kirloskar/Mico/TVS
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
S&F actuator fuel controller for 1010 KVA DG set complete all as specified and directed by Engr - in-Charge.
S&F in replacement of Air cleaner element (inner and outer) suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
Replacement of Fuel filter elements(primary & secondary) for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
M & L for changing /toping up of high quality of engine oil 15W40 type for turbo charged exclusively formulated multigrade suitable for all weather condition for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed.Make:-Castrol/Mak lubricants/ Valvoline
S&F in replacement of 'V' belt for water pump suitable for following capacity DG Sets make Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
S&F in replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets make: Kirloskar/Cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
S&F for Repair and replacement of Dynamo Assy for following capacity DG Set Make Kirloskar/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
S&F replacement of auotmatic voltage regulator(AVR) 24 volt suitable for following capacity of DG Set :- Make Kirloskar/ cummins/Greaves
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
S&F in replacement of self starter for following capacity DG Set Make Kirloskar/ cummins/Greavescomplete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
S&F in replacement of water pump assembly for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
S&F in replacement of Turbo charger assy.for following capacity DG sets make : Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
S&F in replacement of Fan Hub assembely for following capacity DG set make cummins/Kirloskar/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
M&L for disconnecting the U/S DC alternator of following capacity DG Set, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engineer-in-charge.
1010 KVA DG Sets
500 KVA DG set
280 KVA DG set
M&L for taking out burnt winding of exciter of following capacity of DG sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load complete all as specified and directed by Engineer-in-charge.
1010 KVA DG Sets
500 KVA DG set
380 KVA DG set
280 KVA DG Set
For Srl ITem No 16 and 17 here-in-above: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
S&F in replacement of lub oil pump suitable for following Capacity DG Sets,make :Kirloskar/Cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
S&F in replacement of thermostate valve suitable for following Capacity DG Sets make Kirloskar/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
S&F in replacement of Oil seal front and rearsuitable side for following Capacity DG Sets make Kirloskar/ cummins/Greaves complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Sets
500 KVA DG Sets
280 KVA DG Set
S&F in Replacement Battery 12 Volt 180 AH (Maint free heavy duty with initial charging.Make- Exide/Amaron/Luminous all as specified and directed by Engr-in-Charge.
M &L for Removing the fuel injection pump (FIP) & injectors from following capacity of DG sets and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
M & L for dismantling the defective radiator assembly and taking it to contractor workshop for cleaning of radiator , finding the leakages by pressure method and providing leak proof treatment to defective radiator assemble by welding/brazing/glazing suitable material for cohesiveness for following capacity DG sets cleaning radiator by using K oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and Re-assembling after painting of the same complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
M&L for replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as directed
M&L for replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as directed
S&F in replacement of broken door hinges/handles of acoustic enclosure of 1010 KVA DG Set complete with manufacturer recommended handles/hinges using nut bolts etc as per site requirement of any type and make of DG set all as directed at site.
S&F in replacement of broken door hinges/handles of acoustic enclosure of 380 KVA DG Set complete with manufacturer recommended handles/hinges using nut bolts etc as per site requirement of any type and make of DG set all as directed at site.
Materials and labour for scraping removing and cleaning old rusty paint from body of DG set of following capacity any make by cleaning agents & painting the DG set complete with Polyurethane (PU) paint as specified and directed at site by Engr-in Charge.
1010 KVA DG Set
500 KVA DG Sets
380 KVA DG Set
280 KVA DG Set
Taking down old rusted unserviceable silencer single/double with exhaust pipe and M&L for new silencer with Exhaust pipe complete bends, coupling etc suitable for following capacity of DG set including fixing arrangements and painting with silver paint and insulating with suitable size and length of asbestos rope complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
500 KVA DG Sets
380 KVA DG Set
280 KVA DG Set
Calibration of PT pumps, replacement of PT pump kit, gasket set, washers, nuts, plungers, delivery valves, oil pump, O ring and set the oil pressure with testing suitable for 500 KVA DG set complete all as directed by Engr-in-Charge.
Supply, fixing and testing of PCB of digital controller panel of 1010 KVA Cummins DG set having cat part No PCC3300 as per sample complete all as specified and directed by Engr-in-Charge.
Supply, fixing and testing of PCB card controller of type Auxillary 105 suitable for PCC3300 of digital controller panel of 1010 KVA Cummins DG set as per sample complete all as specified and directed by Engr-in-Charge.
Labour, service and calibration charges of PCB card PCC3300 type with DG set digital panel controller card complete and testing on completion showing the working condition of all finger tip control features of the 1010 KVA Cummins DG Set all as specified and directed by Engr-in-Charge.
M&L for testing and replacement of control relays and connected control wirings using suitable size AC/DC cables of sizes for 1010 KVA DG set digital control monitoring panel done by OEM recommended technician/wireman and testing complete all as specified and directed by Egr-in-Charge.
M&L for wiring harness having cat part No : AO34X423 for suitable size wires to be used for 1010 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 100 AMP, TPN complete all as specified and directed by Engr-in-Charge.
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 200 AMP, TPN complete all as specified and directed by Engr-in-Charge.
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 400 AMP, TPN complete all as specified and directed by Engr-in-Charge.
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 630 AMP, TPN complete all as specified and directed by Engr-in-Charge.
Supply and fixing Offload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415V AC, 50 Hz, of capacity 800 AMP, TPN complete all as specified and directed by Engr-in-Charge.
Dismantling disconnecting the defected fuel valve of 1010 KVA DG Sets supply and fixing the same complete all as specified and directed by Engr-in-charge.
Supply and fixing of Air pipe (Turbo to Radiator) for any capacity of DG Set complete all as specified and directed by Engr-in-charge.
Supply and fixing of bty charging alternator (12 volt) with 2 wire system for any capacity of DG Set complete all as specified and directed by Engr-in-charge.
Supply and fixing of Digital RPM meter with Hour meter for any capacity of DG Set complete all as specified and directed by Engr-in-charge.
Supply and fixing Air cleaner assembly kit for 1010 KVA DG set complete all as specified and directed by Engr-in-charge.
S&F Stainless steel, Grey colour anti-vibration support pads for isolating the DG Set engine and alternator from the mounting frame having weighing capacity upto 400 Kgs each for suitable capacity of DG set complete all as specified and directed by Engr-in-Charge.
Supply and Replacement of battry terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
Repair /servicing self Starter by S&F including taking out following parts (A) Field Coil (B) Armature Winding (c) Bush (d) Solenoid Switch/(Gear) for following capacity of DG Sets
1010 KVA DG Set
500 KVA DG Set
380 KVA DG Set
280 KVA DG Set
250 KVA DG Set
180 KVA DG Set
100 KVA DG Set
62.5 KVA DG set
35 KVA DG Set
20 KVA DG Set
S&F battery cable assy with copper conductor multistranded RED and BLACK colour 2mtr long 21sqmm for connection to self starter unit to Battery unit complete all as specified and directed by Engr-in-Charge.
Supply & toping up of best quality anti freezing, Inhabitor Corrosion (Coolant ) liquid for DG set at various capacity and locations complete all as specified and directed. Make-Castrol/Veedol/Valvoline
Dismantling of block assembly engine of 280 KVA DG Set of Make Greaves and taken it to civil Workshop and back make the DG set in serviciable condition and fixed it into its original positon and testing the DG set on load upto the entire satisfaction of Engr-in-Charge. Note 1. Defective parts shall be measured and paid under respective items of Sch . 2.Transpotation charges deemed in quoted rates . 3.Old and U/S parts shall be the contractors property and recovered as credit Sch attached.)
Repair to cylinder head assy. by cutting, grinding and polishing of valve , seats and fixing of valve, valve gouide and pressure testing of cylinder head.
Labour for Injector nozzle calibration and replacement of burnt out parts complete.
Replacement of Radiator assembly
Supply and fixing in replacement the following spare and parts for complete serviceabilty of 280 KVA DG set.
Piston assembly
Cylinder liner
Piston ring set
Valve seat
Valve Guide
Set of hose
Set of hose clamps
Set of fuel pipe
Main bearing set
Valve steam seal
Packing kit
Main seal set, pulley seal, timing seal set
Head gasket
Note: Make of spare parts to be replaced under this work and mentioned in relevant items in this BOQ here-in-before shall be of approved make and as per the manufacturer's recommendation of DG sets and other equipments.
PADMA ENTERPRISES
M/S STANZIN NOBROO
M/S MA CONSTRUCTION Co
M/S TASHI PHUNCHOK GOVT CONTRACTOR
BETONG BUILDERS
THINLES OTZER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .