Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC | ₹2.7 L | L1 | Accepted-AOC L1 becomes L1 |
| 2 | L2₹2.9 L+₹15,665 (5.71%)Rejected-AOC 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | ₹2.9 L+₹15,665 (5.71%) | L2 | Rejected-AOC L2 becomes L2 |
| 3 | L3₹3.2 L+₹44,115 (16.1%)Rejected-AOC C 36 DUGGAL COLONY KHANPUR DEVLI ROAD DELHI 110062 | SOUTH | DELHI | 110062 | ₹3.2 L+₹44,115 (16.1%) | L3 | Rejected-AOC L3 becomes L3 |
Tender Value
Refer Docs
EMD Value
₹5,680
Closing Date
8 Feb 2021, 6:00 pmClosed
AGM Engg.(E)
O/o AGM (E-E), Safdarjung Airport
Renovation of Radar Store Room at Safdarjung Airport, New Delhi. SH- Electrical Works.
2021_AAI_68207_1
AAI/SAP/Engg.(E)/OA/El RadarSMU/F5/St room/20-21
Open Tender
Electrical Works
Works
90 days
Old Area, Safdarjung Airport
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
₹5,680
Yes
8 Jun 2021
28 Jan 2021
10 Feb 2021
29 Jan 2021
8 Feb 2021
29 Jan 2021
29 Jan 2021 - 4 Feb 2021
Amount
SH I - Wiring, Fittings & Cableing
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply of recess mounted LED of size 600mm x 600mm made of CRCA sheet housing, fixture should have rated system lumen output of minimum 3600 lumen with rated efficacy at system level (not chip level) > = 100 lumens/watt, life of fixture is not less than 50000 hrs @ L-70 lumen maintenance, CCT upto 5700K - 6500K, CRI minimum 80, PF >= 0.95, THD < 10% and an operating voltage range of 140 to 270V, internal surge protection > 2KV, with unified glare rating (UGR) <= 19. The fixture should comply with the other parameters as per IS10322.
Supply of 20W (±10%) T8 4 feet high efficacy low power consumption LED tube light fittings (i/c batten & tube rod) having IP20 rating compatible with retrofit type tube light have rated system lumens output of minimum 2000 lumens with rated efficacy at system level (not chip level) >= 100 lumens/Watt, life of fixture is not less than 50000 hrs @ L-70 lumen maintenance, CCT upto 5700K - 6500K, CRI minimum 80, PF >= 0.95, THD < 10% and an operating voltage range of 140 to 270V, internal surge protection > 2KV, with unified glare rating (UGR) <= 19. The fixture should comply with the other parameters as per IS10322.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
SITC of 400mm sweep 230V, 50 Hz single phase, 1400rpm Wall mounting fan having power consumption less than 60W, MS ribs guard for protection, pull cord control for speed & oscillation On-Off and making the electrical connections with all the accessories as required.
Supply of following sizes of 1.1kv grade multicore Aluminium conductor XLPE insulated PVC sheathed armoured cable (as per IS : 7098:1988 with upto date amendments) complete as requried as per specifications.
3.5 core, 25 Sqmm, Aluminium cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 25 sq. mm (28 mm)
SH-II:- SITC of AC
Supply of 1.5 TR Inverter type, 5 star BEE rating, Hi- wall, Split air-conditioner with rotary compressor operating on refrigerant R-32A/ R-410A. The body of indoor unit shall be made of ABS/HIPS/GS, condensing unit should be of 100% copper coil & having all safety, air filters, evaporator, condenser, cordless remote, electronic operation control & all accessories supplied with the unit by OEM etc as per manufacturer standards suitable for operation on 230 volts , 50 Hz, Single phase, AC supply, complete as required at site.
Installation, testing, commissioning of hi-wall A/C units etc. and making of necessary hole on concrete/brick wall and making good the damages i/c providing suitable size PVC pipe for drawing the gas/drain pipe and wire etc through the concrete/brick wall as required.
Supply and fitting of Appropriate size and thickness of MS Stand / L-Chair for fixing outdoor unit or Condensing Units along with necessary anchor fastner/bolt & nuts etc on concrete/brick wall or floor etc. as required.
Supply & fixing of extra copper refrigerant piping of standard gauge for installation of above units as required at site.
Supply & fixing of hard PVC drain piping of proper dia for installation of above units as required at site beyond company provided standard length.
Supply, Installing, Testing and Commissioning of Voltage Stabilizer suitable for 2 TR split AC units on wall including providing connections etc. as required. ( Model-V Guard VGB 500 or equivalent).
NATIONAL SAFETY ENGINEERS
ANU ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .